Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
Chin Clin Oncol ; 13(4): 55, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39238343

RESUMO

BACKGROUND AND OBJECTIVE: The landscape of surgical training is undergoing transformative changes, especially in the realm of robot-assisted procedures like radical prostatectomy (RARP). This narrative review explores the evolving methodologies and innovations in RARP training, emphasizing the shift from traditional training approaches, such as the Halsted method, to more scientific methods like proficiency-based progression (PBP). The rationale for the review stems from the increased adoption of robot-assisted surgery and the resulting increase in associated adverse events reported in the United States. The Patient Safety in Robotic Surgery (SAFROS) project initiated by the European Commission of the World Health Organization emphasized the importance of structured training programs for robotic surgeons. However, the review points out the limited availability of standardized curricula for RARP training, leading to non-homogeneous training worldwide. METHODS: PubMed was searched primarily for the following topics: training AND robotic AND prostatectomy; robotic training AND prostatectomy AND learning; simulator AND robotic AND prostatectomy. Literature was selected based on historical significance and landmark studies as well as publications published after 2000. References from select studies were additionally included. KEY CONTENT AND FINDINGS: The advent of robotic surgery, especially in RARP, demands unique skills necessitating specialized training. The review delves into the diverse stages of robotic surgery training, starting with e-learning and progressing through virtual reality simulators, dry and wet laboratories, culminating in modular console training. Each training stage plays a critical role, addressing the challenges posed by new technologies and tools. CONCLUSIONS: The ever-evolving landscape of surgical training underscores the critical need for globally standardized, effective, and accessible programs. PBP emerges as a promising methodology, and technological advancements open new possibilities for telementoring via platforms like 5G. This review emphasizes the imperative to equip surgeons with the requisite skills for intricate procedures like RARP, addressing current challenges while anticipating the future developments in this dynamic field.


Assuntos
Prostatectomia , Procedimentos Cirúrgicos Robóticos , Humanos , Prostatectomia/métodos , Prostatectomia/educação , Procedimentos Cirúrgicos Robóticos/educação , Procedimentos Cirúrgicos Robóticos/métodos , Masculino
2.
J Robot Surg ; 18(1): 342, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39298048

RESUMO

Robotic surgery has expanded internationally at pace. There are multiple local robotic training pathways but there is inconsistency in standardisation of core common components for curricula internationally. A framework is required to define key objectives that can be implemented across robotic training ecosystems. This Delphi consensus aimed to provide recommendations for core considerations in robotic training design across diverse training environments internationally. A literature search was performed and an international steering committee (AG, KL, JW, HM, TC) proposed key components for contemporary robotic training design and a modified Delphi approach was used to gather stakeholder opinion. The outcomes were then discussed at a face-to-face international expert consensus at the IMRA educational session at the Society of Robotic Surgery (SRS) meeting and final voting was conducted on outstanding items. Stakeholders included robotic surgeons, proctors, trainees and robotic surgical training providers. There was consensus achieved in 139 statements organised into 15 themes. There was 100% agreement that standardised themes in robotic curricula may improve patient safety. Key take-home messages include-training curricula should be multiplatform, non-technical skills are an important component of a robotic curriculum as well as console and bedside skills, clinically relevant performance metrics should be used for assessment where available, the reliance on cadaveric and live animal models should be reduced as high-fidelity synthetic models emerge, and stepwise component training is useful for advanced procedural training. These consensus recommendations are intended to guide design of fit for purpose contemporary robotic surgical curricula. Integration of these components into robotic training pathways internationally is recommended.


Assuntos
Consenso , Currículo , Técnica Delphi , Procedimentos Cirúrgicos Robóticos , Procedimentos Cirúrgicos Robóticos/educação , Procedimentos Cirúrgicos Robóticos/normas , Humanos , Competência Clínica/normas , Internacionalidade
3.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39257213

RESUMO

AIMS: In cardiac device implantation, having both surgical skills and ability to manipulate catheter/lead/wire is crucial. Few cardiologists, however, receive formal surgical training prior to implanting. Skills are mostly acquired directly on-the-job and surgical technique varies across institutions; suboptimal approaches may increase complications. We investigated how novel proficiency-based progression (PBP) simulation training impacts the surgical quality of implantations, compared to traditional simulation (SIM) training. METHODS AND RESULTS: In this international prospective study, novice implanters were randomized (blinded) 1:1 to participate in a simulation-based procedure training curriculum, with proficiency demonstration requirements for advancing (PBP approach) or without (SIM). Ultimately, trainees performed the surgical tasks of an implant on a porcine tissue that was video-recorded and then scored by two independent assessors (blinded to group), using previously validated performance metrics. Primary outcomes were the number of procedural Steps Completed, Critical Errors, Errors (non-critical), and All Errors Combined. Thirty novice implanters from 10 countries participated. Baseline experiences were similar between groups. Compared to SIM-trained, the PBP-trained group completed on average 11% more procedural Steps (P < 0.001) and made 61.2% fewer Critical Errors (P < 0.001), 57.1% fewer Errors (P = 0.140), and 60.7% fewer All Errors Combined (P = 0.001); 11/15 (73%) PBP trainees demonstrated the predefined target performance level vs. 3/15 SIM trainees (20%) in the video-recorded performance. CONCLUSION: Proficiency-based progression training produces superior objectively assessed novice operators' surgical performance in device implantation compared with traditional (simulation) training. Systematic PBP incorporation into formal academic surgical skills training is recommended before in vivo device practice. Future studies will quantify PBP training's effect on surgery-related device complications.


Assuntos
Competência Clínica , Treinamento por Simulação , Humanos , Estudos Prospectivos , Feminino , Masculino , Suínos , Currículo , Animais , Análise e Desempenho de Tarefas , Implantação de Prótese/educação , Gravação em Vídeo , Educação de Pós-Graduação em Medicina/métodos , Curva de Aprendizado , Erros Médicos/prevenção & controle , Adulto , Desfibriladores Implantáveis , Cardiologistas/educação , Modelos Animais
4.
BJU Int ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830818

RESUMO

OBJECTIVE: To develop performance metrics that objectively define a reference approach to a transurethral resection of bladder tumours (TURBT) procedure, seek consensus on the performance metrics from a group of international experts. METHODS: The characterisation of a reference approach to a TURBT procedure was performed by identifying phases and explicitly defined procedure events (i.e., steps, errors, and critical errors). An international panel of experienced urologists (i.e., Delphi panel) was then assembled to scrutinise the metrics using a modified Delphi process. Based on the panel's feedback, the proposed metrics could be edited, supplemented, or deleted. A voting process was conducted to establish the consensus level on the metrics. Consensus was defined as the panel majority (i.e., >80%) agreeing that the metric definitions were accurate and acceptable. The number of metric units before and after the Delphi meeting were presented. RESULTS: A core metrics group (i.e., characterisation group) deconstructed the TURBT procedure. The reference case was identified as an elective TURBT on a male patient, diagnosed after full diagnostic evaluation with three or fewer bladder tumours of ≤3 cm. The characterisation group identified six procedure phases, 60 procedure steps, 43 errors, and 40 critical errors. The metrics were presented to the Delphi panel which included 15 experts from six countries. After the Delphi, six procedure phases, 63 procedure steps, 47 errors, and 41 critical errors were identified. The Delphi panel achieved a 100% consensus. CONCLUSION: Performance metrics to characterise a reference approach to TURBT were developed and an international panel of experts reached 100% consensus on them. This consensus supports their face and content validity. The metrics can now be used for a proficiency-based progression training curriculum for TURBT.

5.
Eur Urol ; 86(2): 130-145, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38644144

RESUMO

BACKGROUND AND OBJECTIVE: Different training programs have been developed to improve trainee outcomes in urology. However, evidence on the optimal training methodology is sparse. Our aim was to provide a comprehensive description of the training programs available for urological robotic surgery and endourology, assess their validity, and highlight the fundamental elements of future training pathways. METHODS: We systematically reviewed the literature using PubMed/Medline, Embase, and Web of Science databases. The validity of each training model was assessed. The methodological quality of studies on metrics and curricula was graded using the MERSQI scale. The level of evidence (LoE) and level of recommendation for surgical curricula were awarded using the educational Oxford Centre for Evidence-Based Medicine classification. KEY FINDINGS AND LIMITATIONS: A total of 75 studies were identified. Many simulators have been developed to aid trainees in mastering skills required for both robotic and endourology procedures, but only four demonstrated predictive validity. For assessment of trainee proficiency, we identified 18 in robotics training and six in endourology training; however, the majority are Likert-type scales. Although proficiency-based progression (PBP) curricula demonstrated superior outcomes to traditional training in preclinical settings, only four of six (67%) in robotics and three of nine (33%) in endourology are PBP-based. Among these, the Fundamentals of Robotic Surgery and the SIMULATE curricula have the highest LoE (level 1b). The lack of a quantitative synthesis is the main limitation of our study. CONCLUSIONS AND CLINICAL IMPLICATIONS: Training curricula that integrate simulators and PBP methodology have been introduced to standardize trainee outcomes in robotics and endourology. However, evidence regarding their educational impact remains restricted to preclinical studies. Efforts should be made to expand these training programs to different surgical procedures and assess their clinical impact.


Assuntos
Procedimentos Cirúrgicos Robóticos , Procedimentos Cirúrgicos Urológicos , Urologia , Procedimentos Cirúrgicos Robóticos/educação , Procedimentos Cirúrgicos Robóticos/normas , Humanos , Urologia/educação , Urologia/normas , Procedimentos Cirúrgicos Urológicos/educação , Procedimentos Cirúrgicos Urológicos/normas , Currículo , Competência Clínica , Educação de Pós-Graduação em Medicina/normas , Educação de Pós-Graduação em Medicina/métodos
6.
J Robot Surg ; 18(1): 153, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563887

RESUMO

Robot-assisted partial nephrectomy (RAPN) is a complex and index procedure that urologists need to learn how to perform safely. No validated performance metrics specifically developed for a RAPN training model (TM) exist. A Core Metrics Group specifically adapted human RAPN metrics to be used in a newly developed RAPN TM, explicitly defining phases, steps, errors, and critical errors. A modified Delphi meeting concurred on the face and content validation of the new metrics. One hundred percent consensus was achieved by the Delphi panel on 8 Phases, 32 Steps, 136 Errors and 64 Critical Errors. Two trained assessors evaluated recorded video performances of novice and expert RAPN surgeons executing an emulated RAPN in the newly developed TM. There were no differences in procedure Steps completed by the two groups. Experienced RAPN surgeons made 34% fewer Total Errors than the Novice group. Performance score for both groups was divided at the median score using Total Error scores, into HiError and LoError subgroups. The LowErrs Expert RAPN surgeons group made 118% fewer Total Errors than the Novice HiErrs group. Furthermore, the LowErrs Expert RAPN surgeons made 77% fewer Total Errors than the HiErrs Expert RAPN surgeons. These results established construct and discriminative validity of the metrics. The authors described a novel RAPN TM and its associated performance metrics with evidence supporting their face, content, construct, and discriminative validation. This report and evidence support the implementation of a simulation-based proficiency-based progression (PBP) training program for RAPN.


Assuntos
Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Aprendizagem , Benchmarking , Transfusão de Sangue , Nefrectomia
7.
Minerva Urol Nephrol ; 76(1): 110-115, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38426425

RESUMO

Standardized training programs for open (OKT) and robot-assisted kidney transplantation (RAKT) remain unmet clinical needs. To fill this gap, we designed a modified Delphi Consensus aiming to propose the first structured surgical curricula for both OKT and RAKT, involving a multispecialty international panel of experts. Two web-based surveys were built drafting two separate series of statements (for OKT and RAKT, respectively). The two surveys were delivered to a panel of 63 experts (for OKT) and 21 experts (for RAKT), selected considering their experience, academic profile and involvement in international associations. Consensus was defined as ≥75% agreement between the responders. Overall, 25/63 (40%) and 14/21 (67%) participated in the first round of the Delphi Consensus for the development of the structured curriculum for OKT and RAKT, respectively. During the second round, the experts reached consensus on all statements, as well as on the domains composing the structure of the training pathway: 1) eligibility criteria for trainees and host centres; 2) theoretical training; 3) simulation; 4) real case observation; and 5) modular training in the operating theatre. To the best of our knowledge, this is the first proposal of a dedicated curriculum for OKT and RAKT grounded on insights from international experts of different specialties. Our proposed curriculum provides the foundation to standardize the education and training in KT across Europe and beyond.


Assuntos
Transplante de Rim , Robótica , Currículo , Escolaridade , Consenso
9.
Diagnostics (Basel) ; 13(21)2023 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-37958283

RESUMO

(1) Background: Surgical phases form the basic building blocks for surgical skill assessment, feedback, and teaching. The phase duration itself and its correlation with clinical parameters at diagnosis have not yet been investigated. Novel commercial platforms provide phase indications but have not been assessed for accuracy yet. (2) Methods: We assessed 100 robot-assisted partial nephrectomy videos for phase durations based on previously defined proficiency metrics. We developed an annotation framework and subsequently compared our annotations to an existing commercial solution (Touch Surgery, Medtronic™). We subsequently explored clinical correlations between phase durations and parameters derived from diagnosis and treatment. (3) Results: An objective and uniform phase assessment requires precise definitions derived from an iterative revision process. A comparison to a commercial solution shows large differences in definitions across phases. BMI and the duration of renal tumor identification are positively correlated, as are tumor complexity and both tumor excision and renorrhaphy duration. (4) Conclusions: The surgical phase duration can be correlated with certain clinical outcomes. Further research should investigate whether the retrieved correlations are also clinically meaningful. This requires an increase in dataset sizes and facilitation through intelligent computer vision algorithms. Commercial platforms can facilitate this dataset expansion and help unlock the full potential, provided that the phase annotation details are disclosed.

10.
Diagnostics (Basel) ; 13(19)2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37835812

RESUMO

The prevalence of renal cell carcinoma (RCC) is increasing due to advanced imaging techniques. Surgical resection is the standard treatment, involving complex radical and partial nephrectomy procedures that demand extensive training and planning. Furthermore, artificial intelligence (AI) can potentially aid the training process in the field of kidney cancer. This review explores how artificial intelligence (AI) can create a framework for kidney cancer surgery to address training difficulties. Following PRISMA 2020 criteria, an exhaustive search of PubMed and SCOPUS databases was conducted without any filters or restrictions. Inclusion criteria encompassed original English articles focusing on AI's role in kidney cancer surgical training. On the other hand, all non-original articles and articles published in any language other than English were excluded. Two independent reviewers assessed the articles, with a third party settling any disagreement. Study specifics, AI tools, methodologies, endpoints, and outcomes were extracted by the same authors. The Oxford Center for Evidence-Based Medicine's evidence levels were employed to assess the studies. Out of 468 identified records, 14 eligible studies were selected. Potential AI applications in kidney cancer surgical training include analyzing surgical workflow, annotating instruments, identifying tissues, and 3D reconstruction. AI is capable of appraising surgical skills, including the identification of procedural steps and instrument tracking. While AI and augmented reality (AR) enhance training, challenges persist in real-time tracking and registration. The utilization of AI-driven 3D reconstruction proves beneficial for intraoperative guidance and preoperative preparation. Artificial intelligence (AI) shows potential for advancing surgical training by providing unbiased evaluations, personalized feedback, and enhanced learning processes. Yet challenges such as consistent metric measurement, ethical concerns, and data privacy must be addressed. The integration of AI into kidney cancer surgical training offers solutions to training difficulties and a boost to surgical education. However, to fully harness its potential, additional studies are imperative.

11.
Ann Surg Open ; 4(3): e307, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37746611

RESUMO

Objective: To compare binary metrics and Global Evaluative Assessment of Robotic Skills (GEARS) evaluations of training outcome assessments for reliability, sensitivity, and specificity. Background: GEARS-Likert-scale skills assessment are a widely accepted tool for robotic surgical training outcome evaluations. Proficiency-based progression (PBP) training is another methodology but uses binary performance metrics for evaluations. Methods: In a prospective, randomized, and blinded study, we compared conventional with PBP training for a robotic suturing, knot-tying anastomosis task. Thirty-six surgical residents from 16 Belgium residency programs were randomized. In the skills laboratory, the PBP group trained until they demonstrated a quantitatively defined proficiency benchmark. The conventional group were yoked to the same training time but without the proficiency requirement. The final trial was video recorded and assessed with binary metrics and GEARS by robotic surgeons blinded to individual, group, and residency program. Sensitivity and specificity of the two assessment methods were evaluated with area under the curve (AUC) and receiver operating characteristics (ROC) curves. Results: The PBP group made 42% fewer objectively assessed performance errors than the conventional group (P < 0.001) and scored 15% better on the GEARS assessment (P = 0.033). The mean interrater reliability for binary metrics and GEARS was 0.87 and 0.38, respectively. Binary total error metrics AUC was 97% and for GEARS 85%. With a sensitivity threshold of 0.8, false positives rates were 3% and 25% for, respectively, the binary and GEARS assessments. Conclusions: Binary metrics for scoring a robotic VUA task demonstrated better psychometric properties than the GEARS assessment.

12.
JAMA Netw Open ; 6(8): e2322750, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37651144

RESUMO

Importance: In cardiac device implant training, there is no common system to objectively assess trainees' ability to perform tasks at predetermined performance levels before in vivo practice; therefore, patients are potentially exposed to risks related to operators' early learning curve. Objective: To assess the effect on implant performance quality of novel metrics-based simulation training to proficiency (proficiency-based progression [PBP]) vs traditional simulation-based training (SBT). Design, Setting, and Participants: In this prospective randomized trial, conducted between March 8, 2022 and November 24, 2022, novice implanters were randomized (blinded) 1:1 to participate in an SBT curriculum (procedural knowledge e-learning and in-person simulation training) at an international skills training center, with proficiency demonstration requirements at each training stage for advancing (PBP approach) or without the requirements. Ultimately, trainees performed a cardiac resynchronization therapy (CRT) implant using virtual reality simulation. The procedure was video-recorded and subsequently scored using previously validated metrics by 2 independent assessors blinded to group. Physicians who had already implanted more than 20 pacemakers or defibrillators and fewer than 200 CRT systems as the first operator were eligible. Thirty-two implanters from 10 countries voluntarily enrolled in the training program and were randomized; 30 (15 per group) started and completed training. Data analysis was performed from November 27 to December 22, 2022. Intervention: Training with PBP vs SBT. Main Outcome and Measures: The primary outcome comprised 4 objectively assessed performance metrics derived from the video-recordings: number of procedural steps completed, errors, critical errors, and all errors combined. Results: Baseline experience of the 30 participants (19 [63%] male; mean [SD] number of years in implant practice, 2.0 [1.8]; median [IQR] number of implanted pacemakers or defibrillators, 47.5 [30.0-115.0]; median [IQR] number of implanted CRT systems, 3.0 [1.25-10.0]) was similar between study groups. Compared with the SBT group, the PBP group completed 27% more procedural steps (median [IQR], 31 [30-32] vs 24 [22-27]; P < .001) and made 73% fewer errors (median [IQR], 2 [1-3] vs 7 [5-8]; P < .001), 84% fewer critical errors (median [IQR], 1 [0-1] vs 3 [3-5]; P < .001), and 77% fewer all errors combined (errors plus critical errors) (median [IQR], 3 [1-3] vs 11 [8-12]; P < .001); 14 of the 15 PBP trainees (93%) demonstrated the predefined target performance level vs 0 of the 15 SBT trainees. Conclusions and Relevance: In this randomized trial, the PBP approach to novice implanter training generated superior objectively assessed performance vs SBT. If implemented broadly and systematically, PBP training may ensure safe and effective performance standards before trainees proceed to (supervised) in vivo practice. Future studies are needed to verify implications on procedure-related patient complications. Trial Registration: ClinicalTrials.gov Identifier: NCT05952908.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Humanos , Masculino , Feminino , Benchmarking , Estudos Prospectivos , Currículo
13.
J Dent ; 135: 104584, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37295548

RESUMO

OBJECTIVE: The objective of this study was to develop and operationally define procedural performance metrics for the Class II posterior composite resin restoration procedure and to obtain face and content validity through a consensus meeting. METHODS: A Metrics Group consisting of 4 experienced Consultants in Restorative Dentistry, an experienced member of staff from the Restorative Dentistry department in CUDSH and a senior behavioural scientist and education/training expert deconstructed the performance of the Class II posterior composite resin restoration and defined performance metrics. At a modified Delphi meeting, 20 experts in the field of Restorative Dentistry from 11 different Dental Institutions critiqued these metrics and their operational definitions before reaching consensus. RESULTS: Initially performance metrics consisting of 15 Phases, 45 steps, 42 errors and 34 critical errors were identified that characterize the performance of the Class II posterior resin composite procedure. During the Delphi panel these were modified and consensus was reached on 15 Phases (with a change to the initial sequence) with 46 Steps (1 added, 13 modified), 37 Errors (2 added, 1 deleted, 6 reclassified as Critical Error), and 43 Critical Errors (9 added). Consensus on the resulting metrics was obtained and face and content validity verified. CONCLUSIONS: It is possible to develop and objectively define performance metrics that comprehensively characterize a Class II posterior composite resin restoration. It is also possible to achieve consensus on the metrics from a Delphi panel of experts and to confirm the face and content validity of those procedure metrics.


Assuntos
Resinas Compostas , Cárie Dentária , Humanos , Benchmarking , Restauração Dentária Permanente , Assistência Odontológica
15.
Eur J Anaesthesiol ; 40(6): 391-398, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36974452

RESUMO

BACKGROUND: Ultrasound-guided, internal jugular venous (IJV) cannulation is a core technical skill for anaesthesiologists and intensivists. OBJECTIVES: At a modified Delphi panel meeting, to define and reach consensus on a set of objective ultrasound-guided IJV cannulation performance metrics on behalf of the College of Anaesthesiologists of Ireland (CAI). To use these metrics to objectively score video recordings of novice and experienced anaesthesiologists. DESIGN: An observational study. SETTING: CAI, March to June 2016 and four CAI training hospitals, November 2016 to July 2019. PARTICIPANTS: Metric development group: two CAI national directors of postgraduate training (specialist anaesthesiolgists), a behavioural scientist, a specialist intensivist and a senior CAI trainee. Scoring by two blinded assessors of video recordings of novice ( n  = 11) and experienced anaesthesiologists ( n  = 15) ultrasound-guided IJV cannulations. MAIN OUTCOME MEASURES: A set of agreed CAI objective performance metrics, that is, steps, errors, and critical errors characterising ultrasound-guided IJV cannulation. The difference in performance scores between novice and experienced anaesthesiologists as determined by skill level defined as being below or above the median total error score (errors plus critical errors): that is, low error (LoErr) and high error (HiErr), respectively. RESULTS: The study identified 47 steps, 18 errors and 13 critical errors through six phases.Variability was observed in the range of total error scores for both novice (1 to 3) and experienced (0 to 4.5) anaesthesiologists. This resulted in two further statistically different subgroups (LoErr and HiErr) for both novice ( P  = 0.011) and experienced practitioners ( P  < 0.000). The LoErr-experienced group performed the best in relation to steps, errors and total errors. Critical errors were only observed in the experienced group. CONCLUSION: A set of valid, reliable objective performance metrics has been developed for ultrasound-guided IJV cannulation. Considerable skill variability underlines the need to develop a CAI simulation-training programme using these metrics.


Assuntos
Cateterismo Venoso Central , Veias Jugulares , Humanos , Veias Jugulares/diagnóstico por imagem , Benchmarking , Irlanda , Estudos Prospectivos , Cateterismo Venoso Central/métodos , Ultrassonografia de Intervenção/métodos
16.
J Robot Surg ; 17(4): 1401-1409, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36689078

RESUMO

RAPN training usually takes place in-vivo and methods vary across countries/institutions. No common system exists to objectively assess trainee capacity to perform RAPN at predetermined performance levels prior to in-vivo practice. The identification of objective performance metrics for RAPN training is a crucial starting point to improve training and surgical outcomes. The authors sought to examine the reliability, construct and discriminative validity of objective intraoperative performance metrics which best characterize the optimal and suboptimal performance of a reference approach for training novice RAPN surgeons. Seven Novice and 9 Experienced RAPN surgeons video recorded one or two independently performed RAPN procedures in the human. The videos were anonymized and two experienced urology surgeons were trained to reliably score RAPN performance, using previously developed metrics. The assessors were blinded to the performing surgeon, hospital and surgeon group. They independently scored surgeon RAPN performance. Novice and Experienced group performance scores were compared for procedure steps completed and errors made. Each group was divided at the median for Total Errors score, and subgroup scores (i.e., Novice HiErrs and LoErrs, Experienced HiErrs and LoErrs) were compared. The mean inter-rater reliability (IRR) for scoring was 0.95 (range 0.84-1). Compared with Novices, Experienced RAPN surgeons made 69% fewer procedural Total Errors. This difference was accentuated when the LoErr Expert RAPN surgeon's performance was compared with the HiErrs Novice RAPN surgeon's performance with an observed 170% fewer Total Errors. GEARS showed poor reliability (Mean IRR = 0.44; range 0.0-0.8), for scoring RAPN surgical performance. The RAPN procedure metrics reliably distinguish Novice and Experienced surgeon performances. They further differentiated performance levels within a group with similar experiences. Reliable and valid metrics will underpin quality-assured novice RAPN surgical training.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Reprodutibilidade dos Testes , Competência Clínica , Nefrectomia/educação
17.
Eur Urol Focus ; 9(2): 388-395, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36229343

RESUMO

BACKGROUND: Robot-assisted partial nephrectomy (RAPN) training usually takes place in vivo, and methods vary across countries/institutions. No common system exists to objectively assess trainee ability to perform RAPN at predetermined performance levels prior to in vivo practice. The identification of objective performance metrics for RAPN training is a crucial starting point to improve training and surgical outcomes. OBJECTIVE: We sought to identify objective performance metrics that best characterize a reference approach to RAPN, and obtain face and content validity from procedure experts through a modified Delphi meeting. DESIGN, SETTING, AND PARTICIPANTS: During a series of online meetings, a core metrics team of three RAPN experts and a senior behavioral scientist performed a detailed task deconstruction of a transperitoneal left-sided RAPN procedure. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Based on published guidelines, manufacturers' instructions, and unedited videos of RAPN, the team identified performance metrics that constitute an optimal approach for training purposes. The metrics were then subjected to an in-person modified international Delphi panel meeting with 19 expert surgeons. RESULTS AND LIMITATIONS: Eleven procedure phases, with 64 procedure steps, 43 errors, and 39 critical errors, were identified. After the modified Delphi process, the international expert panel added 13 metrics (two steps), six were deleted, and three were modified; 100% panel consensus on the resulting metrics was obtained. Limitations are that the metrics are applicable only to left-sided RAPN cases and some might have been excluded. CONCLUSIONS: Performance metrics that accurately characterize RAPN procedure were developed by a core group of experts. The metrics were then presented to and endorsed by an international panel of very experienced peers. Reliable and valid metrics underpin effective, quality-assured, structured surgical training for RAPN. PATIENT SUMMARY: We organize a meeting among robot-assisted partial nephrectomy (RAPN) experts to identify and reach consensus on objective performance metrics for RAPN training. The metrics are a crucial starting point to improve and quality assure surgical training and patients' clinical outcomes.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Consenso , Procedimentos Cirúrgicos Robóticos/métodos , Nefrectomia/métodos
20.
Front Neurol ; 13: 742263, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36237633

RESUMO

Ischemic stroke is one of the leading causes of death and long-term disability in the West. Mechanical revascularization techniques are considered the standard of care for large vessel occlusive stroke. Traditional apprenticeship models involve doctors training their skills on patients. Simulation platforms have long been recognized as an alternative to this. There has however been very little robust assessment of the training outcomes achieved on some of these platforms. At best, these simulations increase understanding of the procedural process and may help improve some technical skills; at worst they may instill bad habits and poor technique. The prerequisite of any simulation process must be to teach what to do, with which devices, in the correct sequence as well as what not to do. It should provide valid metric-based feedback to the trainee that is objective, transparent, and fair for formative and summative performance feedback. It should deliver a training program that measures the performance progress of trainees against expert benchmarks-benchmarks that represent an evidence-based peer-reviewed standard. In this paper, we present a perspective for PBP training for thrombectomy based on our experience with the process of procedure characterization, metric validation, and early experience of using this approach for proficiency training. Patient outcomes are not only determined by optimal performance in the Angio Suite but also by an efficient patient procedure pathway. There will be value in utilizing the PBP training standard not only for the procedure itself but also for the constituent elements of the stroke pathway to further improve treatment outcomes for ischemic stroke patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA