Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 19(13): 1867-73, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15945022

RESUMO

The size-exclusion chromatography (SEC) of acetone-soluble, pyridine-soluble and pyridine-insoluble fractions of a coal tar pitch indicates a bimodal distribution in each fraction. The proportion of high-mass material excluded from the SEC column porosity increases with solvent polarity. The polymer calibration of SEC shows the mass range of the small molecules to be from approximately 100 u to approximately 6000 u, with the mass range of the large excluded molecules above 200 000 u and up to several million u. In contrast, matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) shows a similar low-mass range of ion abundances (< m/z 6000), but with a smaller range of high-mass ion abundances, from approximately m/z 10 000 to 100 000. The large molecules may have three-dimensional structures to allow molecules of relatively low mass to behave as if they are of large size in SEC. Laser desorption mass spectrometry of the acetone- and pyridine-soluble fractions produced molecular ions of polycyclic aromatics that can be related to the known compositions from gas chromatography (GC) mass spectrometry. The experimental conditions used to generate the bimodal distribution by MALDI-MS involve reducing the ion signal intensities to avoid overload of the detector and enable detection of the high-mass ions, by reducing the high-mass detector voltage (i.e. sensitivity) and increasing the laser power.

2.
Rapid Commun Mass Spectrom ; 18(3): 331-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14755620

RESUMO

Oligomeric carbon and siloxane series have been observed by matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS), during the analysis of the dichloromethane (DCM)-soluble fractions of condensable material recovered from fuel-rich flames. Laser desorption (LD) spectra showed a pattern of oligomeric dimethyl-siloxane structures with a spacing of 74 u. The siloxane series appears to have originated as contamination of samples by silicone oil used to lubricate connections of polymer tubing. This was confirmed by extracting silicone tubing and silicone grease with DCM followed by MALDI-MS analysis. A series of peaks with a mass spacing of 24 u was also observed, superimposed on the continuum of unresolved organic ions. This oligomeric series appears to correspond to polycyclic aromatics separated by (mainly) ethylene bridges. Thus LD-MS appears to have revealed a series of soot precursors, intermediate between polycyclic aromatics and particulate soot, which was not detected by MALDI-MS. More detailed work is necessary to define these species with precision.


Assuntos
Compostos Inorgânicos de Carbono/análise , Carbono/química , Siloxanas/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Incineração , Lasers , Compostos Policíclicos/análise , Polímeros/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA