Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Invest Ophthalmol Vis Sci ; 65(1): 24, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38193759

RESUMO

Purpose: Dominant optic atrophy (DOA) is an inherited condition caused by autosomal dominant mutations involving the OPA-1 gene. The aim of this study was to assess the relationship between macular ganglion cell and inner plexiform layer (GC-IPL) thickness obtained from structural optical coherence tomography (OCT) and visual outcomes in DOA patients. Methods: The study recruited 33 patients with confirmed OPA-1 heterozygous mutation and DOA. OCT scans were conducted to measure the GC-IPL thickness. The average and sectorial Early Treatment Diabetic Retinopathy Study (ETDRS) charts (six-sector macular analysis to enhance the topographical analysis) centered on the fovea were considered. Several regression analyses were carried out to investigate the associations between OCT metrics and final best-corrected visual acuity (BCVA) as the dependent variable. Results: The mean BCVA was 0.43 ± 0.37 logMAR, and the average macular GC-IPL thickness was 43.65 ± 12.56 µm. All of the GC-IPL sectors were significantly reduced and correlated with BCVA. The univariate linear regression and the multivariate stepwise regression modeling showed that the strongest association with final BCVA was observed with the internal superior GC-IPL thickness. Dividing patients based on BCVA, we found a specific pattern. Specifically, in patients with BCVA ≤ 0.3 logMAR, the external superior and inferior sectors together with the internal superior were more significant; whereas, for BCVA > 0.3 logMAR, the external superior sector and internal superior sector were more significant. Conclusions: The study identified OCT biomarkers associated with visual outcomes in DOA patients. Moreover, we assessed a specific OCT biomarker for DOA progression, ranging from patients in the early stages of disease with more preserved GC-IPL sectorial thickness to advanced stages with severe thinning.


Assuntos
Atrofia Óptica Autossômica Dominante , Humanos , Atrofia Óptica Autossômica Dominante/diagnóstico , Atrofia Óptica Autossômica Dominante/genética , Neurônios , Fóvea Central , Retina , Biomarcadores
2.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 261-265, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37584789

RESUMO

PURPOSE: Peripapillary hyperreflective ovoid mass-like structures (PHOMS) represent an optical coherence tomography (OCT) finding that has been characterized in different forms of pseudopapilledema. The aim of this study was to investigate the prevalence of PHOMS in patients affected by acute LHON using structural OCT, and to provide a detailed description of these findings. METHODS: Patients with a clinical and molecularly confirmed diagnosis of acute LHON (visual loss having occurred less than 6 months) were enrolled from the neuro-ophthalmology clinic at San Raffaele Scientific Institute. Patients had a complete ophthalmologic evaluation, including imaging with structural OCT. RESULTS: Our analysis included 16 patients (21 eyes-8 males and 8 females) with acute LHON. Structural OCT exhibited PHOMS in 12 eyes from 9 patients with a prevalence rate of 57.1%. In a subsequent topographical assessment in the peripapillary area, the most common location of PHOMS was the temporal region (12 out of 12 eyes), while the nasal region was affected in 2 eyes (16.7%). Considering the 12 eyes with PHOMS, mean ± SD temporal peripapillary RNFL thickness was 87.5 ± 28.4 microns. The temporal peripapillary RNFL thickness was significantly lower in eyes without PHOMS (63.7 ± 32.2 microns; P = 0.40). At the 12-month follow-up visit, PHOMS disappeared in 10 out of 12 eyes. CONCLUSIONS: Acute LHON eyes have PHOMS which are mainly confined to the temporal peripapillary sector. PHOMS may represent swelled retinal fibers that have herniated or are in stasis.


Assuntos
Atrofia Óptica Hereditária de Leber , Doenças do Nervo Óptico , Masculino , Feminino , Humanos , Atrofia Óptica Hereditária de Leber/diagnóstico , Retina , Tomografia de Coerência Óptica/métodos
3.
Am J Ophthalmol ; 260: 102-114, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38092314

RESUMO

PURPOSE: This study aimed to explore the concept of total keratometry (TK) by analyzing extensive international datasets representing diverse ethnic backgrounds. The primary objective was to quantify the disparities between traditional keratometry (K) and TK values in normal eyes and assess their impact on intraocular lens (IOL) power calculations using various formulas. DESIGN: Retrospective multicenter intra-instrument reliability analysis. METHODS: The study involved the analysis of biometry data collected from ten international centers across Europe, the United States, and Asia. Corneal power was expressed as equivalent power and astigmatic vector components for both K and TK values. The study assessed the influence of these differences on IOL power calculations using different formulas. The results were analyzed and plotted using Bland-Altman and double angle plots. RESULTS: The study encompassed a total of 116,982 measurements from 57,862 right eyes and 59,120 left eyes. The analysis revealed a high level of agreement between K and TK values, with 93.98% of eyes exhibiting an absolute difference of 0.25 D or less. Astigmatism vector differences exceeding 0.25 D and 0.50 D were observed in 39.43% and 1.08% of eyes, respectively. CONCLUSIONS: This large-scale study underscores the similarity between mean K and TK values in healthy eyes, with rare clinical implications for IOL power calculation. Noteworthy differences were observed in astigmatism values between K and TK. Future investigations should delve into the practicality of TK values for astigmatism correction and their implications for surgical outcomes.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Tomografia de Coerência Óptica/métodos , Astigmatismo/diagnóstico , Reprodutibilidade dos Testes , Córnea , Biometria/métodos , Estudos Retrospectivos , Refração Ocular
4.
Eur J Ophthalmol ; : 11206721231176312, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37218171

RESUMO

Refractive surgery is one of the most common elective surgeries performed worldwide. The incidence of dry eye disease (DED) after corneal refractive surgery varies among different studies. Pre-existing untreated DED has been identified as a risk factor for postsurgical dry eye symptoms. On the basis of both evidence and clinical experience, some recommendations for ocular surface and DED management pre- and post-refractive surgery are described. In aqueous deficiency Dry Eye Disease, preservative-free lubricating drops should be preferred, in addition to ointment and gel forms. Topical anti-inflammatory agents (Cyclosporine 0.1%, hydrocortisone phosphate, fluorometholone) should be used for 3-6 months in cases of ocular surface damage. The therapy of evaporative DED includes lifestyle modifications, lid hygiene (either performed by the patient or offered as professional lid hygiene by the physician), use of lubricating eye drops with lipid components, topical and/or systemic antibiotic treatment with anti-inflammatory properties and Intense Pulsed Light (IPL-) Treatment for meibomian gland dysfunction.

5.
J Cataract Refract Surg ; 49(1): 5-10, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36026703

RESUMO

PURPOSE: To evaluate the repeatability of the measurements provided by a new optical biometer (EyeStar 900) based on swept-source optical coherence tomography (SS-OCT) and their agreement with the measurements given by 2 validated biometers based on the same technology, the IOLMaster 700 and Argos. SETTING: IRCCS G.B. Bietti Foundation, Rome, Italy. DESIGN: Prospective evaluation of diagnostic test. METHODS: In a series of unoperated eyes, 3 consecutive scans were acquired with the EyeStar 900, and 1 with the IOLMaster 700 and the Argos. The following biometry parameters were analyzed: axial length (AL), keratometry (K), corneal astigmatism, central corneal thickness, corneal diameter (CD), anterior chamber depth (ACD), lens thickness (LT), and lens tilting. Repeatability was assessed using test-retest variability, the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC); agreement was based on the 95% limits of agreement. RESULTS: 56 eyes of 56 patients were analyzed. High repeatability was achieved for all measured parameters, as the CoV was <1% in most cases and ICC was >0.95 for all parameters. Good to high agreement was found among the measurements of the 3 optical biometers, although some statistically significant differences were detected between the EyeStar 900 and Argos (mean K, ACD, LT, and CD were higher with the Argos). The Argos measured a shorter AL in eyes >25 mm. CONCLUSIONS: The new generation SS-OCT EyeStar 900 optical biometer produces highly repeatable measurements that are in good agreement with those provided by 2 previously validated instruments.


Assuntos
Comprimento Axial do Olho , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Comprimento Axial do Olho/anatomia & histologia , Reprodutibilidade dos Testes , Interferometria , Estudos Prospectivos , Córnea/anatomia & histologia , Biometria/métodos , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia
6.
J Refract Surg ; 38(3): 158-166, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35275002

RESUMO

PURPOSE: To compare the objective and subjective outcomes between the extended depth of focus (EDOF) Mini Well intraocular lens (IOL) and the aspheric monofocal Mini-4-Ready IOL (both SIFI S.p.A.) in patients with high myopia. METHODS: In this prospective comparative study, 40 patients with high myopia (axial length ≥ 26 mm) were enrolled: 20 patients were bilaterally implanted with the EDOF Mini Well IOL (EDOF group) and 20 patients were bilaterally implanted with the Mini-4-Ready IOL (monofocal group). Three-month follow-up data included corrected and uncorrected distance visual acuity at 4 m and 80, 67, and 40 cm, defocus curves, subjective and objective contrast sensitivity, objective optical quality (calculated with Optical Quality Analysis System; Visiometrics SL), halometry, and reading performance. Subjective visual quality was evaluated with National Eye Institute Refractive Error Quality of Life Instrument 42 scores. RESULTS: All visual acuities were significantly better in the EDOF group (P ⩽ .04) except monocular and binocular uncorrected and corrected distance visual acuities for distance (P ≥ .50). Defocus curves for myopic and hyperopic values were better in the EDOF group (P ⩽ .05), apart from +0.50 to -0.50 D (P ≥ .16). Contrast sensitivity curves was worse in the EDOF group in the mesopic-with-glare condition (P ⩽ .04). No differences were found in halometric values (P ≥ .15) and OQAS outcomes (P ≥ .47). National Eye Institute Refractive Error Quality of Life Instrument 42 subscale scores were better for expectation, near vision, activity limitations, and dependence on correction in the EDOF group (P ⩽ .04). CONCLUSIONS: Intermediate and near visual acuities were better in the EDOF group than in the monofocal group, with a comparable visual quality index between groups. [J Refract Surg. 2022;38(3):158-166.].


Assuntos
Miopia , Facoemulsificação , Percepção de Profundidade , Humanos , Miopia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida
7.
Int Ophthalmol ; 41(5): 1949-1957, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33625651

RESUMO

PURPOSE: To review recent progress, challenges, and future perspectives of stromal keratophakia for the treatment of advanced keratoconus. METHODS: We systematically reviewed the literature in the PubMed database, last update June 30, 2020. No language restriction was applied. The authors checked the reference lists of the retrieved articles to identify any additional study of interest. RESULTS: Several techniques have been proposed for the treatment of keratoconus in order to avoid or delay keratoplasty. This was primarily due to the lack of accessibility to donor corneas in many countries. The ease and predictability of the more advanced femtosecond lasers used to correct ametropias by stromal lenticule extraction lead to hypothesize that generated refractive lenticules could be implanted into corneal stromal layers to restore volume and alter the refractive properties of the cornea in patients with corneal ectasias. At the same time, new techniques for preservation, customization, and cellular therapy of the corneal stromal have been developed, directing to the valorization of otherwise discarded byproducts such as donor corneas unsuitable for either lamellar of penetrating keratoplasty. CONCLUSIONS: Femtosecond laser-assisted stromal keratophakia could be a suitable therapeutic option for the treatment of corneal ectasias, especially in patients with advanced keratoconus, providing biomechanical support recovering the pachimetry to nearly normal value at the same time. The accuracy and predictability of the refractive outcome are yet a critical issue and the patient eligible for the procedure still has to be characterized.


Assuntos
Cirurgia da Córnea a Laser , Transplante de Córnea , Ceratocone , Substância Própria/cirurgia , Topografia da Córnea , Humanos , Ceratocone/cirurgia , Lasers
8.
BMJ Open Ophthalmol ; 5(1): e000497, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33083552

RESUMO

OBJECTIVE: To evaluate objective and subjective outcomes after bilateral implantation of two different multifocal intraocular lenses, which correct pseudophakic presbyopia in an adequate and homogeneous population court. METHODS AND ANALYSIS: Fifty patients were evaluated at 3 months after bilateral implantation, at the Eye Clinic of University of Verona and at the Carones Ophthalmology Center Milano, as follows: Tecnis Symfony (25 patients), Alcon PanOptix (25 patients). Main outcomes were uncorrected and best-corrected distance visual acuity (UDVA and BCVA) at 4 m, 60 cm (best distance corrected intermediate visual acuity (BDCIVA) and uncorrected intermediate visual acuity), 40 cm (best distance corrected near visual acuity (BDCNVA) and uncorrected near visual acuity (UNVA)), objective refractive outcome, defocus curve, contrast sensitivity (Modulation Transfer Function (MTF) cut-off), optical quality (Strehl ratio), aberrometry (root mean square RMS 4 mm), subjective quality of life (National Eye Institute Refractive Error Quality of Life score (NEI-RQL-42 score) test). RESULTS: Symfony and PanOptix showed BCVA and UDVA comparable results. Symfony presented significant better outcomes at BDCIVA (p=0.001), while PanOptix showed better performances at BDCNVA and UNVA (p=0.01). Symfony achieved better results in RMS 4 mm (p=0.024) and in MTF cut-off (p=0.041). In the questionnaire NEI-RQL-42, PanOptix presented better scores in 'near vision' and 'spectacles independence', whereas Symfony in 'symptoms' and 'clarity of vision'. CONCLUSION: Both intraocular lenses are valid options to avoid pseudophakic presbyopia, even though they present different features which make them unique. Symfony allows patients to achieve a better objective and subjective quality of vision and contrast sensitivity; PanOptix provides better outcomes in near vision and spectacles independence requirements.

9.
J Refract Surg ; 36(4): 214-222, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32267951

RESUMO

PURPOSE: To evaluate and compare the objective and subjective outcomes between bilateral implantation of the extended depth of focus (EDOF) Mini Well intraocular lens (IOL) and the aspheric monofocal Mini-4-Ready IOL (both SIFI S.p.A., Catania, Italy). METHODS: This prospective comparative study included 25 patients (50 eyes) bilaterally implanted with an EDOF Mini Well IOL (EDOF group) and 25 patients (50 eyes) bilaterally implanted with a Mini-4-Ready IOL (monofocal group). Three-month follow-up data included corrected and uncorrected distance visual acuity at 4 m and 80, 67, and 40 cm. Defocus curves, subjective and objective contrast sensitivity, and objective optical quality (modulation transfer function cutoff and Strehl ratio calculated with Optical Quality Analysis System [OQAS]; Visiometrics SL, Terrassa, Spain), halometry, and reading performance were measured. Subjective visual quality was evaluated based on National Eye Institute Refractive Error Quality of Life Instrument 42 (NEI RQL-42) scores. RESULTS: Postoperative uncorrected and corrected monocular and binocular intermediate and near visual acuity was significantly better in the EDOF group (P < .001). No differences were observed for distance visual acuity (P ⩾ .312). Defocus curve outcomes for myopic values were better in the EDOF group (P < .001). No significant differences were found in hyperopic (obtained in steps of +0.50 diopters [D] from emmetropia to 1.50 D) values (P ⩾ .095), contrast sensitivity curves (P ⩾ .087), or OQAS outcomes (P ⩾ .138). Halometric values were significantly better in the monofocal group (P < .05). There was a correlation between mean keratometry values and intermediate/near visual acuity. Significantly better NEI RQL-42 subscale scores for near vision, far vision, activity limitations, glare, dependence on correction, and suboptimal correction were noted in the EDOF group (P < .05). CONCLUSIONS: Intermediate and near visual acuity was better after EDOF IOL than after aspheric monofocal IOL implantation while maintaining similar levels of visual quality, except for halo perception. [J Refract Surg. 2020;36(4):214-222.].


Assuntos
Percepção de Profundidade/fisiologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Pseudofacia/cirurgia , Refração Ocular/fisiologia , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA