Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Talanta ; 152: 251-8, 2016 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-26992518

RESUMO

Polybrominated diphenylethers (PBDE), used as flame retardants, are named as priority substances in the Directive 2000/60/EC of the European parliament and of the council establishing a framework for Community action in the field of water policy. An annual average environmental quality standard (EQS) for inland surface waters of 0.0005 µg/L (0.0002 µg/L for other surface waters) for PBDE congeners involved in the technical penta-PBDE mixtures containing PBDE with five bromine atoms has been established. The directives focus especially on the congeners PBDE 28, 47, 99, 100, 153 and 154 contained in the penta-PBDE mixture. Up to now, no reference measurement procedures have been established reaching the limits of quantification (LOQs) and the associated uncertainties as defined in the directives with results traceable to the SI. Within a recent European project on metrology, different approaches for the traceable quantification of PBDE, based on liquid/liquid or solid phase extraction followed by the detection with gas chromatography coupled to either inductively coupled plasma mass spectrometry or triple quadrupole mass spectrometry, were investigated and the related LOQs and expanded uncertainties of the results were compared. A complete uncertainty budget for each method was estimated according to the Guide to the Expression of Uncertainty in Measurement (GUM). All presented analytical procedures can serve as reference measurement procedures regarding the LOQs and their associated expanded uncertainties for monitoring the six priority PBDEs named above. LOQs as low as 0.026 ng/kg with an associated expanded uncertainty of 0.002 ng/kg could be achieved.


Assuntos
Monitoramento Ambiental/legislação & jurisprudência , Retardadores de Chama/isolamento & purificação , Água Doce/química , Éteres Difenil Halogenados/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , Monitoramento Ambiental/métodos , Humanos , Limite de Detecção , Extração Líquido-Líquido/métodos , Extração em Fase Sólida/métodos , Espectrofotometria Atômica
2.
Anal Bioanal Chem ; 407(11): 3055-67, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25486919

RESUMO

One of the unresolved issues of the European Water Framework Directive is the unavailability of realistic water reference materials for the organic priority pollutants at low nanogram-per-liter concentrations. In the present study, three different types of ready-to-use water test materials were developed for polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) at nanogram-per-liter levels. The first type simulated the dissolved phase in the water and comprised of a solution of humic acids (HA) at 5 mg L(-1) dissolved organic carbon (DOC) and a spike of the target compounds. The second type of water sample incorporated the particulate phase in water. To this end, model suspended particulate matter (SPM) with a realistic particle size was produced by jet milling soil and sediments containing known amounts of PAHs, PBDEs and TBT and added as slurry to mineral water. The most complex test materials mimicked "whole water" consequently containing both phases, the model SPM and the HA solution with the target analytes strongly bound to the SPM. In this paper, the development of concepts, processing of the starting materials, characterisation of the HA and model SPMs as well as results for homogeneity and stability testing of the ready-to-use test materials are described in detail.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA