Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081287

RESUMO

We report on the x-ray background rate measured with transition-edge sensors (TES) micro-calorimeters under frequency-domain multiplexing (FDM) readout as a possible technology for future experiments aiming at a direct detection of axion-like particles. Future axion helioscopes will make use of large magnets to convert axions into photons in the keV range and x-ray detectors to observe them. To achieve this, a detector array with high spectral performance and extremely low background is necessary. TES are single-photon, non-dispersive, high-resolution micro-calorimeters and represent a possible candidate for this application. We have been developing x-ray TES micro-calorimeters and an FDM readout technology in the framework of the space-borne x-ray astronomical observatories. We show that the current generation of our detectors is already a promising technology for a possible axion search experiment, having measured an x-ray background rate of 2.2(2) × 10-4 cm-2 s-1 keV-1 with a cryogenic demonstrator not optimized for this specific application. We then make a prospect to further improve the background rate down to the required value (<10-7 cm-2 s-1 keV-1) for an axion-search experiment, identifying no fundamental limits to reach such a level.

2.
Rev Sci Instrum ; 93(12): 124901, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586892

RESUMO

We demonstrate multiplexed readout of 43 transition edge sensor (TES) bolometers operating at 90 mK using a frequency division multiplexing (FDM) readout chain with bias frequencies ranging from 1 to 3.5 MHz and a typical frequency spacing of 32 kHz. We improve the previously reported performance of our FDM system by two important steps. First, we replace the coplanar wires with microstrip wires, which minimize the cross talk from mutual inductance. From the measured electrical cross talk (ECT) map, the ECT of all pixels is carrier leakage dominated. Only five pixels show an ECT level higher than 1%. Second, we reduce the thermal response speed of the TES detectors by a factor of 20 by increasing the heat capacity of the TES, which allows us to bias all TES detectors below 50% in transition without oscillations. We compare the current-voltage curves and noise spectra of the TESs measured in single-pixel mode and multiplexing mode. We also compare the noise equivalent power (NEP) and the saturation power of the bolometers in both modes, where 38 pixels show less than 10% difference in NEP and 5% difference in saturation power when measured in the two different modes. The measured noise spectrum is in good agreement with the simulated noise based on measured parameters from an impedance measurement, confirming that our TES is dominated by phonon noise.

3.
Zhonghua Liu Xing Bing Xue Za Zhi ; 43(9): 1408-1414, 2022 Sep 10.
Artigo em Chinês | MEDLINE | ID: mdl-36117347

RESUMO

Objective: To examine the prevalence and trend of tobacco and e-cigarettes uses and identify the influencing factors for smoking behavior in junior middle school students in Shanghai, and provide data support and scientific basis for the development of tobacco control intervention strategy in adolescents. Methods: Multi-stage stratified random sampling method was used to select junior middle school students in 8 districts and 10 districts in Shanghai in 2013 and in 2019 respectively. Information about tobacco and e-cigarettes uses in the students were collected by using self-administrated questionnaire. The prevalence of tobacco and e-cigarettes uses were calculated, the difference between two years was compared with χ2 test. The influencing factors were identified by multivariate logistic regression analysis. Results: In 2019, the current smoking rate was 0.6% in junior middle school students in Shanghai, and the smoking attempt rate was 2.9%, both were lower than the levels in 2013 (0.7% and 6.9%). The current use rate of e-cigarettes was 0.6% in 2019,with no significant change compared with 2013 (0.6%). The proportion of the students who had heard of e-cigarettes in 2019 (78.4%) was higher than that in 2013 (47.2%). In 2019, the second-hand smoke (SHS) exposure rate at home, in both indoor and outdoor public places and on public transportations was 72.5%, which was slightly lower than the level in 2013 (73.0%), the differences were all significant (P<0.05). In 2019, the students seeing close friend smoking (OR=27.381, 95%CI: 12.037-62.287), seeing someone smoking in school (OR=2.477, 95%CI: 1.155-5.312), believing that SHS may not be harmful (OR=8.471, 95%CI: 1.464-49.005) had higher possibility of smoking. Being aged ≥15 years (compared with being aged ≤12 years, OR=8.688, 95%CI: 1.922-39.266), exposure to SHS in outdoor public place (OR=8.608, 95%CI: 1.048-70.692), close friend smoking (OR=8.115, 95%CI: 1.754-37.545) were positively associated with e-cigarettes use, and believing that smoking results in uncomfortable social contact [compared with believing that smoking results in comfortable social contact (OR=0.105,95%CI: 0.018-0.615)] were negatively associated with e-cigarettes use, the difference was significant (P<0.05). Conclusion: The prevalence of tobacco and e-cigarette uses in junior middle school students in Shanghai remained at a low level in recent years. The SHS exposure rate in junior middle school students is high. Smoking behavior of junior middle school students is closely related to personal attitude and awareness of tobacco, exposure to SHS, peer smoking and the situation of tobacco control in schools. Prevention and intervention should be carried out from multi-dimensions to effectively protect teenagers from tobacco hazards.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Poluição por Fumaça de Tabaco , Adolescente , China/epidemiologia , Humanos , Prevalência , Estudantes , Nicotiana
4.
Rev Sci Instrum ; 92(3): 033103, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820098

RESUMO

In the frequency-domain multiplexing (FDM) scheme, transition-edge sensors (TESs) are individually coupled to superconducting LC filters and AC biased at MHz frequencies through a common readout line. To make efficient use of the available readout bandwidth and to minimize the effect of non-linearities, the LC resonators are usually designed to be on a regular grid. The lithographic processes, however, pose a limit on the accuracy of the effective filter resonance frequencies. Off-resonance bias carriers could be used to suppress the impact of intermodulation distortions, which, nonetheless, would significantly affect the effective bias circuit and the detector spectral performance. In this paper, we present a frequency shift algorithm (FSA) to allow off-resonance readout of TESs, while preserving the on-resonance bias circuit and spectral performance, demonstrating its application to the FDM readout of an x-ray TES microcalorimeter array. We discuss the benefits in terms of mitigation of the impact of intermodulation distortions at the cost of increased bias voltage and the scalability of the algorithm to multi-pixel FDM readout. We show that with FSA, in the multi-pixel and frequencies shifted on-grid, the line noises due to intermodulation distortion are placed away from the sensitive region in the TES response and the x-ray performance is consistent with the single-pixel, on-resonance level.

5.
Rev Sci Instrum ; 92(2): 023101, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648117

RESUMO

Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of x-ray space observatories. These arrays are required to achieve an energy resolution ΔE < 3 eV full width at half maximum (FWHM) in the soft x-ray energy range. We are currently developing x-ray microcalorimeter arrays for use in the future laboratory and space-based x-ray astrophysics experiments and ground-based spectrometers. In this contribution, we report on the development and the characterization of a uniform 32 × 32 pixel array with 140 × 30 µm2 Ti/Au TESs with the Au x-ray absorber. We report on extensive measurements on 60 pixels in order to show the uniformity of our large TES array. The averaged critical temperature is Tc = 89.5 ± 0.5 mK, and the variation across the array (∼1 cm) is less than 1.5 mK. We found a large region of detector's bias points between 20% and 40% of the normal-state resistance where the energy resolution is constantly lower than 3 eV. In particular, results show a summed x-ray spectral resolution ΔEFWHM = 2.50 ± 0.04 eV at a photon energy of 5.9 keV, measured in a single-pixel mode using a frequency domain multiplexing readout system developed at SRON/VTT at bias frequencies ranging from 1 MHz to 5 MHz. Moreover, we compare the logarithmic resistance sensitivity with respect to temperature and current (α and ß, respectively) and their correlation with the detector's noise parameter M, showing a homogeneous behavior for all the measured pixels in the array.

6.
Rev Sci Instrum ; 92(1): 014710, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514257

RESUMO

We have characterized and mapped the electrical cross talk (ECT) of a frequency division multiplexing (FDM) system with a transition edge sensor (TES) bolometer array, which is intended for space applications. By adding a small modulation at 120 Hz to the AC bias voltage of one bolometer and measuring the cross talk response in the current noise spectra of the others simultaneously, we have for the first time mapped the ECT level of 61 pixels with a nominal frequency spacing of 32 kHz in a 61 × 61 matrix and a carrier frequency ranging from 1 MHz to 4 MHz. We find that about 94% of the pixels show an ECT level of less than 0.4%. Only the adjacent pixels reach this level, and the ECT for the rest of the pixels is less than 0.1%. We also observe higher ECT levels, up to 10%, between some of the pixels, which have bundled long, parallel coplanar wires connecting TES bolometers to inductor-capacitor filters. In this case, the high mutual inductances dominate. To mitigate this source of ECT, the coplanar wires should be replaced by microstrip wires in the array. Our study suggests that an FDM system can have a relatively low ECT level, e.g., around 0.4% if the frequency spacing is 30 kHz. Our results successfully demonstrate a low electrical cross talk for a space FDM technology.

7.
Zhonghua Wei Chang Wai Ke Za Zhi ; 23(11): 1043-1050, 2020 Nov 25.
Artigo em Chinês | MEDLINE | ID: mdl-33212552

RESUMO

Objective: Surgical site infection (SSI) is the most common infectious complication after emergency abdominal surgery (EAS). To a large extent, most SSI can be prevented, but there are few relevant studies in China. This study mainly investigated the current situation of SSI occurrence after EAS in China, and further explored risk factors for SSI occurrence. Methods: Multi-center cross-sectional study was conducted. Clinical data of patients undergoing EAS in 33 hospitals across China between May 1, 2019 and June 7, 2019 were prospectively collected, including perioperative data and microbial culture results from infected incisions. The primary outcome was the incidence of SSI after EAS, while the secondary outcomes were postoperative hospital stay, ICU occupancy rate, length of ICU stay, hospitalization cost, and mortality within postoperative 30 days. Univariate and multivariate logistic regression models were used to analyze the risk factors of SSI after EAS. Results: A total of 660 EAS patients aged (47.9±18.3) years were enrolled in this study, including 56.5% of males (373/660). Forty-nine (7.4%) patients developed postoperative SSI. The main pathogen of SSI was Escherichia coli [culture positive rate was 32.7% (16/49)]. As compared to patients without SSI, those with SSI were more likely to be older (median 56 years vs. 46 years, U=19 973.5, P<0.001), male [71.4% (35/49) vs. 56.1% (343/611), χ(2)=4.334, P=0.037] and diabetes [14.3% (7/49) vs. 5.1% (31/611), χ(2)=5.498, P=0.015]; with-lower preoperative hemoglobin (median: 122.0 g/L vs. 143.5 g/L, U=11 471.5, P=0.006) and albumin (median: 35.5 g/L vs. 40.8 g/L, U=9452.0, P<0.001), with higher blood glucose (median: 6.9 mmol/L vs. 6.0 mmol/L, U=17 754.5, P<0.001); with intestinal obstruction [32.7% (16/49) vs. 9.2% (56/611), χ(2)=25.749, P<0.001], with ASA score 3-4 [42.9% (21/49) vs. 13.9% (85/611), χ(2)=25.563, P<0.001] and with high surgical risk [49.0% (24/49) vs. 7.0% (43/611), χ(2)=105.301, P<0.001]. The main operative procedure resulting in SSI was laparotomy [81.6%(40/49) vs. 35.7%(218/611), χ(2)=40.232, P<0.001]. Patients with SSI experienced significantly longer operation time (median: 150 minutes vs. 75 minutes, U=25 183.5, P<0.001). In terms of clinical outcome, higher ICU occupancy rate [51.0% (25/49) vs. 19.5% (119/611), χ(2)=26.461, P<0.001], more hospitalization costs (median: 44 000 yuan vs. 15 000 yuan, U=24 660.0, P<0.001), longer postoperative hospital stay (median: 10 days vs. 5 days, U=23 100.0, P<0.001) and longer ICU occupancy time (median: 0 days vs. 0 days, U=19 541.5, P<0.001) were found in the SSI group. Multivariate logistic regression analysis showed that the elderly (OR=3.253, 95% CI: 1.178-8.985, P=0.023), colorectal surgery (OR=9.156, 95% CI: 3.655-22.937, P<0.001) and longer operation time (OR=15.912, 95% CI:6.858-36.916, P<0.001) were independent risk factors of SSI, while the laparoscopic surgery (OR=0.288, 95% CI: 0.119-0.694, P=0.006) was an independent protective factor for SSI. Conclusions: For patients undergoing EAS, attention should be paid to middle-aged and elderly patients and those of colorectal surgery. Laparoscopic surgery should be adopted when feasible and the operation time should be minimized, so as to reduce the incidence of SSI and to reduce the burden on patients and medical institutions.


Assuntos
Abdome , Laparotomia/efeitos adversos , Infecção da Ferida Cirúrgica , Abdome/cirurgia , Adulto , Idoso , China/epidemiologia , Estudos Transversais , Emergências , Feminino , Humanos , Laparotomia/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Infecção da Ferida Cirúrgica/epidemiologia
8.
Rev Sci Instrum ; 90(5): 055107, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31153243

RESUMO

Dilution and adiabatic demagnetization refrigerators based on pulse tube cryocoolers are nowadays used in many low temperature physics experiments, such as atomic force and scanning tunneling microscopy, quantum computing, radiation detectors, and many others. A pulse tube refrigerator greatly simplifies the laboratory activities being a cryogen-free system. The major disadvantage of a pulse tube cooler is the high level of mechanical vibrations at the warm and cold interfaces that could substantially affect the performance of very sensitive cryogenic instruments. In this paper, we describe the performance of a very simple mechanical attenuation system used to eliminate the pulse-tube-induced low frequency noise of the superconducting transition-edge sensors under development for the instruments of the next generation of infra-red and X-ray space observatories.

9.
Opt Express ; 25(24): 29587-29596, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-29220996

RESUMO

We present an 8-beam local oscillator (LO) for the astronomically significant [OI] line at 4.7 THz. The beams are generated using a quantum cascade laser (QCL) in combination with a Fourier phase grating. The grating is fully characterized using a third order distributed feedback (DFB) QCL with a single mode emission at 4.7 THz as the input. The measured diffraction efficiency of 74.3% is in an excellent agreement with the calculated result of 75.4% using a 3D simulation. We show that the power distribution among the diffracted beams is uniform enough for pumping an array receiver. To validate the grating bandwidth, we apply a far-infrared (FIR) gas laser emission at 5.3 THz as the input and find a very similar performance in terms of efficiency, power distribution, and spatial configuration of the diffracted beams. Both results represent the highest operating frequencies of THz phase gratings reported in the literature. By injecting one of the eight diffracted 4.7 THz beams into a superconducting hot electron bolometer (HEB) mixer, we find that the coupled power, taking the optical loss into account, is in consistency with the QCL power value.

10.
Opt Express ; 25(22): 27172-27181, 2017 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-29092196

RESUMO

In recent continuous-variable (CV) multipartite entanglement researches, the number of fully inseparable light modes has been increased dramatically by the introduction of a multiplexing scheme in either the time domain or the frequency domain. In this paper, we propose a scheme that a large-scale (≥ 20) CV dual-rail cluster entangled state is established based on a spatial mode comb in a self-imaging optical parametric oscillator, which is pumped by two spatial Laguerre-Gaussian modes with different polarization and identical frequency. A sufficient condition of full inseparability for a CV dual-rail cluster entangled state is used to evaluate the degree of quantum entanglement. It is shown that entanglement exists over a wide range of analyzing frequency and pump parameter. We have found a new scheme that uses the optical parametric cavity to generate a large-scale entanglement based on optical spatial mode comb. The presented system will be hopefully as a practical entangled source for quantum information.

11.
Opt Express ; 25(6): 6581-6588, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-28381005

RESUMO

We compare the results of simulated and measured power efficiency and far-field beam pattern, for two reflective Fourier phase gratings, designed to generate 2 × 2 and 2 × 4 beams respectively from a single-beam, coherent source at 1.4 THz. The designed surface structures were manufactured on aluminum plates by a computer numerical control (CNC) micro-milling machine. Despite small differences between the designed and fabricated gratings, we measured power efficiencies of both gratings to be around 70%, which is in a good agreement with the simulated values. We also find a good agreement between the simulated and measured diffracted beam size and spatial distribution. We demonstrate the application of both gratings as multiple beam local oscillators to simultaneously pump (or operate) a 4-pixel array of superconducting heterodyne mixers.

12.
Zhonghua Zhong Liu Za Zhi ; 39(1): 18-23, 2017 Jan 23.
Artigo em Chinês | MEDLINE | ID: mdl-28104028

RESUMO

Objective: To investigate the effect of hypoxia inducible factor 2α (HIF-2α) on regulating CUB domain-containing protein 1 (CDCP1) and its role in hepatocellular carcinoma metastasis. Methods: HIF-2α-knocked down and HIF-2α-stably overexpressing cells (MHCC97H) were prepared by small interfering RNA (siRNA) and lentivirus transfection, respectively. The expression of CDCP1 protein and mRNA in the above cells was detected by western blot and real-time PCR. The effect of HIF-2α on cell invasion ability was determined by Transwell assay. Furthermore, immunohistochemical staining was performed to detect the expression of CDCP1 in human HCC tissue samples. Results: Both HIF-2α and CDCP1 were induced under hypoxic conditions. The activation of CDCP1 under hypoxic conditions was dependent on the expression of HIF-2α.When HIF-2α was overexpressed, the mRNA level of CDCP1 was greatly upregulated (5.92±0.28, P<0.05). When HIF-2α was knocked down by siRNA for 48 h and 72 h, the expression of CDCP1 was significantly downregulated (48 h: 0.25±0.04; 72 h: 0.18±0.02, all P<0.05). Moreover, analysis of human HCC samples showed that CDCP1 expression was correlated with tumor-free survival (P<0.05). Conclusions: The results of this study indicate that the expression of CDCP1 is regulated by HIF-2α and is correlated with the progression of HCC. Inhibition of HIF-2α/CDCP1 may play certain inhibitory role in the metastasis of HCC.


Assuntos
Antígenos CD/metabolismo , Fatores de Transcrição Hélice-Alça-Hélice Básicos/metabolismo , Carcinoma Hepatocelular/secundário , Moléculas de Adesão Celular/metabolismo , Neoplasias Hepáticas/patologia , Proteínas de Neoplasias/metabolismo , Animais , Antígenos CD/genética , Antígenos de Neoplasias , Fatores de Transcrição Hélice-Alça-Hélice Básicos/genética , Carcinoma Hepatocelular/metabolismo , Moléculas de Adesão Celular/genética , Movimento Celular , Regulação para Baixo , Técnicas de Inativação de Genes , Humanos , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Neoplasias Hepáticas/metabolismo , Camundongos Nus , Invasividade Neoplásica , Proteínas de Neoplasias/genética , RNA Mensageiro/metabolismo , RNA Interferente Pequeno , Reação em Cadeia da Polimerase em Tempo Real , Transfecção/métodos , Hipóxia Tumoral , Regulação para Cima
13.
Opt Express ; 23(16): 21323-33, 2015 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-26367980

RESUMO

Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.

14.
Opt Express ; 20(13): 14380-91, 2012 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-22714499

RESUMO

We demonstrate for the first time that the Hartmann wavefront sensor (HWS) principle can be applied for characterizing the wavefronts of terahertz (THz) electromagnetic radiation. The THz Hartmann wavefront sensor consists of a metallic plate with an array of holes and a two-dimensional scanable pyro-electric detector. The THz radiation with different wavefronts was generated by a far-infrared gas laser operated at 2.5 THz in combination with a number of objects that result in known wavefronts. To measure the wavefront, a beam passing through an array of holes generates intensity spots, for which the positions of the individual spot centroids are measured and compared with reference positions. The reconstructed wavefronts are in good agreement with the model expectations.


Assuntos
Espectroscopia Terahertz/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
15.
Opt Lett ; 34(19): 2958-60, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19794781

RESUMO

We demonstrate the phase locking of a 2.7 THz metal-metal waveguide quantum cascade laser (QCL) to an external microwave signal. The reference is the 15th harmonic, generated by a semiconductor superlattice nonlinear device, of a signal at 182 GHz, which itself is generated by a multiplier chain (x12) from a microwave synthesizer at approximately 15 GHz. Both laser and reference radiations are coupled into a bolometer mixer, resulting in a beat signal, which is fed into a phase-lock loop. The spectral analysis of the beat signal confirms that the QCL is phase locked. This result opens the possibility to extend heterodyne interferometers into the far-infrared range.

16.
Phys Rev Lett ; 100(25): 257002, 2008 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-18643694

RESUMO

The quasiparticle relaxation time in superconducting films has been measured as a function of temperature using the response of the complex conductivity to photon flux. For tantalum and aluminum, chosen for their difference in electron-phonon coupling strength, we find that at high temperatures the relaxation time increases with decreasing temperature, as expected for electron-phonon interaction. At low temperatures we find in both superconducting materials a saturation of the relaxation time, suggesting the presence of a second relaxation channel not due to electron-phonon interaction.

17.
Opt Lett ; 33(4): 312-4, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18278094

RESUMO

We characterize a heterodyne receiver based on a surface-plasmon waveguide quantum cascade laser (QCL) emitting at 2.84 THz as a local oscillator, and an NbN hot electron bolometer as a mixer. We find that the envelope of the far-field pattern of the QCL is diffraction-limited and superimposed onto interference fringes, which are similar to those found in narrow double-metal waveguide QCLs. Compared to the latter, a more directional beam allows for better coupling of the radiation power to the mixer. We obtain a receiver noise temperature of 1050 K when the mixer is at 2 K, which, to our knowledge, is the highest sensitivity reported at frequencies beyond 2.5 THz.

18.
Insect Mol Biol ; 16(6): 691-701, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18092998

RESUMO

Spinosad is a relatively new insecticide that exerts its toxic action via nicotinic acetylcholine receptors (nAChRs). Spinosad resistance in house flies appears to be due to an altered target site. To evaluate the molecular basis of spinosad resistance, two nAChR subunit genes, Mdalpha5 and Mdbeta3 were cloned and characterized from an insecticide-susceptible (aabys) and spinosad resistant (rspin) strain of the house fly, Musca domestica. The Mdalpha5 and Mdbeta3 cDNAs encode proteins of 781 and 432 amino acid residues, respectively. Phylogenetic analysis with insect nAChR subunits suggested that Mdalpha5 and Mdbeta3 are most closely related to Dalpha5 and Dbeta3 of Drosophila melanogaster, respectively. Mdbeta3 is intronless, which is unique among all previously described nAChR genes. A-to-I RNA editing was found at 13 sites in Mdalpha5, eleven of which resulted in amino acid substitutions. No evidence for A-to-I RNA editing was found in Mdbeta3. Mdalpha5 expression, quantified by real time PCR, was 340- and 23-fold higher in the head and thorax than in the abdomen. Mdbeta3 expression was more uniform, being only 2.4-fold higher in the head and 1.4-fold lower in the thorax, compared to the abdomen. There was no difference in the expression of Mdalpha5 and Mdbeta3 between the aabys and rspin strains. Although Mdalpha5 and Mdbeta3 both map to the same chromosome as spinosad resistance, there were no unique features of either gene in rspin, relative to the aabys strain. This suggests neither Mdalpha5 nor Mdbeta3 is responsible for spinosad resistance in house flies.


Assuntos
Moscas Domésticas/efeitos dos fármacos , Moscas Domésticas/metabolismo , Macrolídeos/farmacologia , Receptores Nicotínicos/metabolismo , Sequência de Aminoácidos , Animais , Sequência de Bases , Clonagem Molecular , Primers do DNA/genética , DNA Complementar/genética , Combinação de Medicamentos , Evolução Molecular , Expressão Gênica , Genes de Insetos , Ligação Genética , Moscas Domésticas/genética , Resistência a Inseticidas/genética , Dados de Sequência Molecular , Filogenia , Subunidades Proteicas , Edição de RNA , Receptores Nicotínicos/química , Receptores Nicotínicos/genética
19.
Insect Mol Biol ; 16(3): 325-34, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17439546

RESUMO

Recent studies showed that deletion of a nicotinic acetylcholine receptor (nAChR) subunit gene, Dalpha6 in Drosophila melanogaster results in a strain that is resistant to spinosad, indicating that Dalpha6 is important for the toxic action of this insecticide. To determine if spinosad resistance in house flies was due to a mutation(s) of Mdalpha6 (the orthologue of Dalpha6 from house flies), cDNAs were cloned and characterized from an insecticide-susceptible and a spinosad-resistant strain of the house fly, Musca domestica. The cDNAs contain a 1470-bp open reading frame encoding 490 amino acid residues, 415-bp 5' untranslated region (UTR) and a polymorphic 3'-UTR of approximately 371 bp. The predicted mature protein possesses 468 amino acid residues, has the typical features of a nAChR alpha subunit and is 97% identical to Dalpha6. Quantitative real-time PCR analysis revealed that Mdalpha6 was expressed in the head and the thorax at 1300- and 26-fold higher levels, respectively, than in the abdomen. There was no difference in the expression level of Mdalpha6 between spinosad-resistant and susceptible strains. Ten isoforms arising from alternative splicing were characterized, with isoform II being most common. A-to-I RNA editing was examined and found at 12 sites: editing at 11 of these sites resulted in an amino acid substitution. Mdalpha6 is linked to autosome 1 (spinosad resistance was previously shown to be linked to autosome 1). Single nucleotide polymorphisms, alternative splicing, mRNA levels and A-to-I RNA editing were compared between head and thorax and between insecticide-susceptible and spinosad-resistant strains. These comparisons indicate that Mdalpha6 is not responsible for spinosad resistance in house flies.


Assuntos
Variação Genética , Moscas Domésticas/genética , Subunidades Proteicas/genética , Processamento Pós-Transcricional do RNA/genética , Receptores Nicotínicos/genética , Processamento Alternativo/genética , Sequência de Aminoácidos , Animais , Sequência de Bases , Primers do DNA/genética , DNA Complementar/genética , Combinação de Medicamentos , Resistência a Inseticidas/genética , Macrolídeos/toxicidade , Dados de Sequência Molecular , Polimorfismo de Nucleotídeo Único , Isoformas de Proteínas/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Análise de Sequência de DNA
20.
J Viral Hepat ; 13(9): 618-24, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16907849

RESUMO

Host genetic factors and environment factors including hepatitis B virus (HBV) genotypes are widely studied for the different outcomes of HBV infection. Recent studies suggest that tumour necrosis factor-alpha (TNF-alpha) plays a pivotal role in the viral clearance and host immune response to HBV, and the capacity for TNF-alpha production in individuals is influenced by a major genetic component. In this study, we aimed to explore whether the single-nucleotide polymorphisms (SNPs) of TNF-alpha promoter are associated with the outcomes of HBV infection in the Chinese Han population. One hundred and forty-three spontaneously recovered HBV subjects and 196 chronic hepatitis B patients were recruited in this case-control study in the Beijing area of China. Polymerase chain reaction-restriction fragment-length polymorphism (PCR-RFLP) and sequence-specific primer-PCR (SSP-PCR) were used to detect the SNPs of five sites in the TNF-alpha promoter (-238G/A, -308G/A, -857C/T, -863C/A, -1031T/C). The frequency distributions of genotypes and haplotypes in two groups were analysed by EPI and EH programs. The presence of the -238GG genotype was significantly correlated with persistence of HBV infection (OR = 4.08, P = 0.02), and -857TT genotype appeared in relation to the spontaneous clearance of HBV (OR = 0.47, P = 0.03). Frequency of haplotype GGCCT (-238/-308/-857/-863/-1031) in the chronic HB group was significantly lower than that in spontaneously recovered group (P = 0.03), and frequencies of haplotypes GGCAT and GGTAT in the chronic HB group were significantly higher than those in the spontaneously recovered group (P = 0.0001, P = 0.0004). In conclusion, TNF-alpha promoter polymorphisms are independently associated with different outcomes of HBV infection.


Assuntos
Hepatite B Crônica/genética , Hepatite B/genética , Polimorfismo de Nucleotídeo Único , Regiões Promotoras Genéticas , Fator de Necrose Tumoral alfa/genética , Adulto , Povo Asiático/genética , Estudos de Casos e Controles , DNA Viral/genética , Progressão da Doença , Feminino , Frequência do Gene , Genótipo , Hepatite B/imunologia , Hepatite B Crônica/imunologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA