Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Retin Cases Brief Rep ; 16(3): 360-361, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32039943

RESUMO

BACKGROUND/PURPOSE: To report a case of torpedo maculopathy with two distinct zones of the retinal pigment epithelium visualized on optical coherence tomography. METHODS: Observational case report. RESULTS: A 6-year-old female presented for a routine examination. Visual acuity was 20/20 bilaterally. Dilated fundus examination was normal in the right eye. Dilated fundus examination of the left eye showed a wedge-shaped area of hypopigmentation in the temporal macula. Optical coherence tomography macula of the left eye showed outer retinal cavitation with segmentation of the foveal retinal pigment epithelium into a superficial fluffy zone and a deeper hyperreflective zone. CONCLUSION: This case helps contribute to the growing body of the torpedo maculopathy literature that may reveal different stages of the same disease evolving over time.


Assuntos
Degeneração Macular , Doenças Retinianas , Criança , Feminino , Angiofluoresceinografia/métodos , Humanos , Doenças Retinianas/diagnóstico , Epitélio Pigmentado da Retina , Tomografia de Coerência Óptica/métodos
2.
Orbit ; 40(2): 155-158, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32283962

RESUMO

A 45-year-old man presented with a progressively enlarging left lower lateral eyelid lesion. The initial biopsy was inconclusive; however, a repeat biopsy 5 years later revealed infiltrative morpheaform basal cell carcinoma with sclerosis. Two years later, the patient presented with ophthalmoplegia of the left eye. Computed tomography illustrated a heterogeneous enhancing soft tissue mass in the inferolateral orbit with erosion into the globe. Despite treatment with vismodegib for 1 year, the lesion progressed to involve the entire left lower eyelid and corneal-scleral junction with adjacent maxillary sinus invasion. The patient tested positive for human immunodeficiency virus and underwent a left orbital exenteration followed by adjuvant radiotherapy. The patient remained stable with no evidence of recurrent disease or distant metastasis 2 years after exenteration. This rare case highlights a neglected basal cell carcinoma in those immunocompromised with histopathological correlation of the aggressive disease on to the globe.


Assuntos
Carcinoma Basocelular , Neoplasias Cutâneas , Anilidas/uso terapêutico , Carcinoma Basocelular/tratamento farmacológico , Humanos , Hospedeiro Imunocomprometido , Masculino , Pessoa de Meia-Idade , Piridinas
3.
J Vitreoretin Dis ; 5(4): 333-336, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37007594

RESUMO

Purpose: This work aims to compare spatial relationships between the crystalline lens and vitrectomy instruments of different gauges. Methods: Eight phakic eyes recovered from deceased donors were used after fixation. Valved trocars (27-gauge, 25-gauge, and 23-gauge) were sequentially placed in the superotemporal quadrant 4 mm posterior to the limbus in each eye. Intraocular relationships of vitrectomy and curved endolaser probes were measured for each gauge. Results: There were no significant differences in maneuverability between instruments of different gauges. The mean distance from instrument to lens at the geometric center of the globe was 5.5 mm. Vitrectomy probes of all gauges could access the peripheral retina on both sides of the sclerotomy in the 3 to 4 o'clock position adjacent to the sclerotomy without touching the lens. The instruments could be advanced without lens touch to contact the retina within at least 2 mm of the ora serrata 180° away from the insertion site. Conclusions: Vitrectomy and curved endolaser probes achieved similar maneuverability relative to the lens regardless of gauge. This study confirms that small-gauge vitrectomy instruments have a considerable range of safe access to the peripheral retina in phakic eyes from a single sclerotomy.

4.
Case Rep Ophthalmol Med ; 2020: 6323646, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32670653

RESUMO

Silicone-based compounds are commonly used in many medical applications, such as coatings for needles and syringes. Foreign body granulomas are a well-recognized complication of silicone exposure; however, they may be challenging to identify without a clear history. A 61-year-old female patient without prior history of periocular injections, filler, or surgery presented to our oculoplastic clinic with multiple periocular lesions. The patient subsequently underwent excisional biopsy of two prominent lesions, which were identified as granulomas on pathology. Further questioning revealed the cause to be facial acupuncture performed decades prior, and a subsequent targeted exam identified additional lesions at other needling sites. A third lesion was subsequently excised, and there was no recurrence at the last follow-up 3 months postsurgery. Acupuncture is an increasingly common but underrecognized source of silicone exposure and can present up to several decades after exposure as a chronic granulomatous response in a characteristic multifocal pattern.

5.
Neural Regen Res ; 13(1): 43-52, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29451203

RESUMO

The canonical Wnt/ß-catenin pathway is a highly conserved signaling cascade that plays critical roles during embryogenesis. Wnt ligands regulate axonal extension, growth cone guidance and synaptogenesis throughout the developing central nervous system (CNS). Recently, studies in mammalian and fish model systems have demonstrated that Wnt/ß-catenin signaling also promotes axonal regeneration in the adult optic nerve and spinal cord after injury, raising the possibility that Wnt could be developed as a therapeutic strategy. In this review, we summarize experimental evidence that reveals novel roles for Wnt signaling in the injured CNS, and discuss possible mechanisms by which Wnt ligands could overcome molecular barriers inhibiting axonal growth to promote regeneration. A central challenge in the neuroscience field is developing therapeutic strategies that induce robust axonal regeneration. Although adult axons have the capacity to respond to axonal guidance molecules after injury, there are several major obstacles for axonal growth, including extensive neuronal death, glial scars at the injury site, and lack of axonal guidance signals. Research in rodents demonstrated that activation of Wnt/ß-catenin signaling in retinal neurons and radial glia induced neuronal survival and axonal growth, but that activation within reactive glia at the injury site promoted proliferation and glial scar formation. Studies in zebrafish spinal cord injury models confirm an axonal regenerative role for Wnt/ß-catenin signaling and identified the cell types responsible. Additionally, in vitro and in vivo studies demonstrated that Wnt induces axonal and neurite growth through transcription-dependent effects of its central mediator ß-catenin, potentially by inducing regeneration-promoting genes. Canonical Wnt signaling may also function through transcription-independent interactions of ß-catenin with cytoskeletal elements, which could stabilize growing axons and control growth cone movement. Therefore, these studies suggest that Wnt-induced pathways responsible for regulating axonal growth during embryogenesis could be repurposed to promote axonal growth after injury.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA