Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Braz. dent. j ; 33(3): 47-54, July-Sept. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1384034

RESUMO

Abstract The aim of this study was to investigate the physicochemical and biological properties of an experimental tricalcium silicate-based repair cement containing diclofenac sodium (CERD). For the physicochemical test, MTA, Biodentine and CERD were mixed and cement disc were prepared to evaluate the setting time and radiopacity. Root-end cavity were performed in acrylic teeth and filled with cements to analyze the solubility up to 7 days. Polyethylene tubes containing cements were prepared and calcium ions and pH were measured at 3h, 24h, 72h and 15 days. For the biological test, SAOS-2 were cultivated, exposed to cements extracts and cell proliferation were investigated by MTT assay at 6h, 24h and 48h. Polyethylene tubes containing cements were implanted into Wistar rats. After 7 and 30 days, the tubes were removed and processed for histological analyses. Parametric and nonparametric data were performed. No difference was identified in relation to setting time, radiopacity and solubility. Biodentine released more calcium ion than MTA and CERD; however, no difference between MTA and CERD were detected. Alkaline pH was observed for all cements and Biodentine exhibited highest pH. All cements promoted a raise on cell proliferation at 24h and 48h, except CERD at 48h. Biodentine stimulated cell metabolism in relation to MTA and CERD while CERD was more cytotoxic than MTA at 48h. Besides, no difference on both inflammatory response and mineralization ability for all cement were found. CERD demonstrated similar proprieties to others endodontic cements available.


Resumo O objetivo deste estudo foi investigar as propriedades físico-químicas e biológicas de um cimento reparador experimental à base de silicato de tricálcio contendo diclofenaco de sódio (CERD). Para o teste físico-químico, MTA, Biodentine e CERD foram manipulados e discos de cimentos foram preparados para avaliar o tempo de presa e a radiopacidade. Retrocavidades foram feitas em dentes de acrílico e preenchidas com cimentos para análise de solubilidade por 7 dias. Tubos de polietileno contendo cimentos foram preparados e os íons cálcio e o pH foram mensurados às 3h, 24h, 72h e 15 dias. Para o teste biológico, SAOS-2 foram cultivadas, expostas aos extratos de cimentos e a proliferação celular foi investigada pelo ensaio de MTT às 6h, 24h e 48h. Tubos de polietileno contendo cimentos foram implantados em ratos Wistar. Após 7 e 30 dias, os tubos foram removidos e processados para análises histológicas. Dados paramétricos e não paramétricos foram realizados. Nenhuma diferença foi identificada em relação ao tempo de presa, radiopacidade e solubilidade. Biodentine liberou mais íons de cálcio do que MTA e CERD; no entanto, nenhuma diferença entre MTA e CERD foi detectada. O pH alcalino foi observado para todos os cimentos e o Biodentine exibiu o pH mais alto. Todos os cimentos promoveram aumento na proliferação celular às 24h e 48h, exceto o CERD às 48h. Biodentine estimulou o metabolismo celular em relação ao MTA e CERD, enquanto CERD foi mais citotóxico do que MTA em 48h. Além disso, nenhuma diferença foi encontrada na resposta inflamatória e na capacidade de mineralização para todos os cimentos. CERD demonstrou propriedades semelhantes a outros cimentos endodônticos disponíveis.

2.
Braz Dent J ; 33(3): 47-54, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35766716

RESUMO

The aim of this study was to investigate the physicochemical and biological properties of an experimental tricalcium silicate-based repair cement containing diclofenac sodium (CERD). For the physicochemical test, MTA, Biodentine and CERD were mixed and cement disc were prepared to evaluate the setting time and radiopacity. Root-end cavity were performed in acrylic teeth and filled with cements to analyze the solubility up to 7 days. Polyethylene tubes containing cements were prepared and calcium ions and pH were measured at 3h, 24h, 72h and 15 days. For the biological test, SAOS-2 were cultivated, exposed to cements extracts and cell proliferation were investigated by MTT assay at 6h, 24h and 48h. Polyethylene tubes containing cements were implanted into Wistar rats. After 7 and 30 days, the tubes were removed and processed for histological analyses. Parametric and nonparametric data were performed. No difference was identified in relation to setting time, radiopacity and solubility. Biodentine released more calcium ion than MTA and CERD; however, no difference between MTA and CERD were detected. Alkaline pH was observed for all cements and Biodentine exhibited highest pH. All cements promoted a raise on cell proliferation at 24h and 48h, except CERD at 48h. Biodentine stimulated cell metabolism in relation to MTA and CERD while CERD was more cytotoxic than MTA at 48h. Besides, no difference on both inflammatory response and mineralization ability for all cement were found. CERD demonstrated similar proprieties to others endodontic cements available.


Assuntos
Compostos de Alumínio , Materiais Restauradores do Canal Radicular , Animais , Ratos , Compostos de Alumínio/química , Anti-Inflamatórios , Anti-Inflamatórios não Esteroides , Cálcio , Compostos de Cálcio/química , Compostos de Cálcio/farmacologia , Cimentos Dentários/química , Cimentos Dentários/farmacologia , Combinação de Medicamentos , Cimentos de Ionômeros de Vidro , Teste de Materiais , Óxidos/química , Polietilenos , Ratos Wistar , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Silicatos/farmacologia
3.
J. res. dent ; 10(2): 16-20, apr.-jun2022.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1395878

RESUMO

Internal inflammatory root resorption (IIRR) can occur as a serious complication of dental trauma which leads to progressive loss of the root structure. An early diagnosis could influence the therapeutic approach, but endodontic treatment becomes a challenge with a doubtful prognosis. The present report described an unusual clinical presentation of an IIRR with perforation resulting from a trauma four years previous. A 15-year-old female patient was presented to our service with pain in the maxillary incisor region. Intraoral radiography revealed a large radioloucent area compatible with IIRR, communicating with the periodontium in the middle third on the distal root face of the right central incisor. The root canal of the right central incisor was chemo-mechanically prepared. The calcium hydroxide (CH) intracanal medication was used and renewed periodically four times. The root canal was filled only in the cervical region to the level of resorption by the inverted gutta-percha cone technique. Clinically and radiographically, all follow-up examinations revealed an asymptomatic tooth, evidencing periapical tissue repair and new bone formation. The tooth remained asymptomatic 3 years afterwards. The present case report supports the idea of executing satisfactory intracanal decontamination by chemo-mechanical preparation, thus creating a favourable environment for tissue repair.


Assuntos
Humanos , Feminino , Tratamento do Canal Radicular , Necrose da Polpa Dentária , Reabsorção da Raiz , Hidróxido de Cálcio
4.
J Clin Exp Dent ; 14(2): e168-e176, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35173900

RESUMO

BACKGROUND: Provisional materials must have enough strength to withstand masticatory loads without suffering deformation or fracture, and their surfaces must have good finishing and polishing characteristics to reduce biofilm accumulation. Thus, the purpose of this study was to investigate the best polishing protocol for different bis-acryl composite resins in comparison with a conventional resin composite and a self-curing acrylic resin aiming to obtain a smooth restoration surface and resistance to wear. MATERIAL AND METHODS: One hundred and four samples (15 mm length x 5 mm width x 4 mm depth) were prepared and divided into four groups according to the material tested: Protemp 4 and Structur 3 bis-acryl composite resins, Dencor self-curing acrylic resin, Filtek Z350XT conventional composite resin. The polishing procedures were performed with Sof-Lex Pop-On discs or Sof-Lex spirals and abrasion procedures were performed on a brushing machine. The surface roughness was analyzed at three periods (initial, post-polishing and post-brushing) and the wear was evaluated after simulated brushing. The results were submitted to ANOVA followed by the Tukey (α = 0.05). RESULTS: Filtek Z350XT groups showed the lowest values of initial surface roughness followed by Structur 3, Protemp 4 and Dencor groups. After polishing and simulated brushing, Filtek Z350XT groups also presented the lowest roughness values, followed by bis-acryl groups (Structur 3 and Protemp 4) and Dencor groups demonstrated the highest surface roughness. Sof-Lex Pop-On discs system exhibited lower roughness values for all groups. CONCLUSIONS: Sof-Lex Pop-On discs system promoted the best polishing for all groups. Overall, Filtek Z350XT groups presented lower results for both roughness and wear for all periods evaluated, followed by Protemp 4 and Structur 3, meanwhile Dencor groups presented the highest roughness and wear values for all periods. Key words:Acrylic resin, bis-acryl, brushing, composite resin, polishing, roughness, wear.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA