Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 93: 137-141, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36906132

RESUMO

BACKGROUND: Recent studies have demonstrated increased postoperative patency with the use of routine completion angiography for bypass using venous conduit. Compared to vein conduits, however, prosthetic conduits are less plagued by technical issues such as unlysed valves or arteriovenous fistulae. The effect of routine completion angiography on bypass patency in prosthetic bypasses has yet to be compared to the more traditional selective use of completion imaging. METHODS: A retrospective review of all infrainguinal bypass procedures using prosthetic conduit completed at a single hospital system from 2001 to 2018 was performed. Demographics, comorbidities, intraoperative reintervention rates, and 30-day rates of graft thrombosis were analyzed. Statistical analysis included t-tests, chi-square tests, and cox regression. RESULTS: Four hundred and ninety-eight bypasses that were performed in 426 patients met inclusion criteria. Fifty-six (11.2%) bypasses were classified into the routine completion angiogram group compared to 442 (88.8%) into the no completion angiogram group. Patients who underwent routine completion angiograms had a rate of intraoperative reintervention of 21.4%. When comparing bypasses that underwent routine completion angiography versus no completion angiography, there were no significant differences in rates of reintervention (3.5% vs. 4.5%, P = 0.74) or graft occlusion (3.5% vs. 4.7%, P = 0.69) at 30-days postoperatively. CONCLUSIONS: Almost one-quarter of lower extremity bypasses using prosthetic conduit that undergo routine completion angiography undergo postangiogram bypass revision; however, this is not associated with an increased graft patency at 30 days postoperatively.


Assuntos
Implante de Prótese Vascular , Oclusão de Enxerto Vascular , Humanos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Grau de Desobstrução Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Fatores de Risco , Angiografia , Estudos Retrospectivos
2.
Eur J Orthop Surg Traumatol ; 31(7): 1485-1492, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33649991

RESUMO

BACKGROUND: The purpose of this study was to determine the angular tolerance of the S1 and S2 segments to accommodate a transiliosacral screw across both sacroiliac joints. HYPOTHESIS: We hypothesized that the angular tolerance for transiliosacral screw placement would be more constrained than the angular tolerance for iliosacral fixation in pelves where a safe osseous corridor was measured. MATERIALS AND METHODS: The cortical boundaries of the S1 and S2 sacral segments in 433 pelvic CTs were digitally mapped. A straight-line path was placed within each osseous corridor and extended across both SI joints past the outer iliac cortices. The diameter of the path was increased until it breached the cortex, geometrically determining maximum diameter (Dmax). Angular tolerance for screw placement was calculated with trigonometric analysis of the Dmax value of the corridor, and the average distance from the termination of the osseous corridor to the site of percutaneous insertion. Gender, age, and BMI were evaluated as independent predictors using binomial logistic regression. RESULTS: The transiliosacral angular tolerance for the S1 and S2 osseous corridors was 1.53 ± 0.57 degrees and 1.02 ± 0.33 degrees, respectively. 68.9% of S1 corridors and 81.1% of S2 corridors had a safe zone (corridor diameter ≥ 10 mm) for transiliosacral placement, 48.3% of the pelves had a safe zone for both corridors, while 5.1% had no safe zones. Females had a less frequent Dmax ≥ 10 mm at S1, 52% vs 67% (p = 0.001), and at S2, 64% vs 86% (p < 0.001). DISCUSSION: In conclusion, the angular tolerance of 1.53 and 1.03 degrees for the S1 and S2 segments, respectively, creating a narrow interval for safe passage of the trans-iliac and trans-sacral, with approximately 31.1% of patients not having a viable corridor for screw passage. A correlation exist between S1 and S2 corridors with Dmax ≥ 10 mm and the resulting increase in angular tolerance for safe passage of a transilioscral screw. LEVEL OF EVIDENCE IV: Level Retrospective Cohort.


Assuntos
Parafusos Ósseos , Sacro , Feminino , Fixação Interna de Fraturas , Humanos , Ílio/cirurgia , Pelve , Estudos Retrospectivos , Sacro/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA