Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(24)2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37949060

RESUMO

Objective.Gradient-based optimization using algorithmic derivatives can be a useful technique to improve engineering designs with respect to a computer-implemented objective function. Likewise, uncertainty quantification through computer simulations can be carried out by means of derivatives of the computer simulation. However, the effectiveness of these techniques depends on how 'well-linearizable' the software is. In this study, we assess how promising derivative information of a typical proton computed tomography (pCT) scan computer simulation is for the aforementioned applications.Approach.This study is mainly based on numerical experiments, in which we repeatedly evaluate three representative computational steps with perturbed input values. We support our observations with a review of the algorithmic steps and arithmetic operations performed by the software, using debugging techniques.Main results.The model-based iterative reconstruction (MBIR) subprocedure (at the end of the software pipeline) and the Monte Carlo (MC) simulation (at the beginning) were piecewise differentiable. However, the observed high density and magnitude of jumps was likely to preclude most meaningful uses of the derivatives. Jumps in the MBIR function arose from the discrete computation of the set of voxels intersected by a proton path, and could be reduced in magnitude by a 'fuzzy voxels' approach. The investigated jumps in the MC function arose from local changes in the control flow that affected the amount of consumed random numbers. The tracking algorithm solves an inherently non-differentiable problem.Significance.Besides the technical challenges of merely applying AD to existing software projects, the MC and MBIR codes must be adapted to compute smoother functions. For the MBIR code, we presented one possible approach for this while for the MC code, this will be subject to further research. For the tracking subprocedure, further research on surrogate models is necessary.


Assuntos
Prótons , Tomografia Computadorizada por Raios X , Simulação por Computador , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Software , Algoritmos , Método de Monte Carlo
2.
Phys Med Biol ; 68(19)2023 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-37652034

RESUMO

Objective.Proton therapy is highly sensitive to range uncertainties due to the nature of the dose deposition of charged particles. To ensure treatment quality, range verification methods can be used to verify that the individual spots in a pencil beam scanning treatment fraction match the treatment plan. This study introduces a novel metric for proton therapy quality control based on uncertainties in range verification of individual spots.Approach.We employ uncertainty-aware deep neural networks to predict the Bragg peak depth in an anthropomorphic phantom based on secondary charged particle detection in a silicon pixel telescope designed for proton computed tomography. The subsequently predicted Bragg peak positions, along with their uncertainties, are compared to the treatment plan, rejecting spots which are predicted to be outside the 95% confidence interval. The such-produced spot rejection rate presents a metric for the quality of the treatment fraction.Main results.The introduced spot rejection rate metric is shown to be well-defined for range predictors with well-calibrated uncertainties. Using this method, treatment errors in the form of lateral shifts can be detected down to 1 mm after around 1400 treated spots with spot intensities of 1 × 107protons. The range verification model used in this metric predicts the Bragg peak depth to a mean absolute error of 1.107 ± 0.015 mm.Significance.Uncertainty-aware machine learning has potential applications in proton therapy quality control. This work presents the foundation for future developments in this area.


Assuntos
Terapia com Prótons , Incerteza , Prótons , Aprendizado de Máquina , Redes Neurais de Computação
3.
IEEE Trans Pattern Anal Mach Intell ; 45(12): 15820-15833, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37581965

RESUMO

We propose a novel technique for reconstructing charged particles in digital tracking calorimeters using reinforcement learning aiming to benefit from the rapid progress and success of neural network architectures without the dependency on simulated or manually-labeled data. Here we optimize by trial-and-error a behavior policy acting as an approximation to the full combinatorial optimization problem, maximizing the physical plausibility of sampled trajectories. In modern processing pipelines used in high energy physics and related applications, tracking plays an essential role allowing to identify and follow charged particle trajectories traversing particle detectors. Due to the high multiplicity of charged particles and their physical interactions, randomly deflecting the particles, the reconstruction is a challenging undertaking, requiring fast, accurate and robust algorithms. Our approach works on graph-structured data, capturing track hypotheses through edge connections between particles in the detector layers. We demonstrate in a comprehensive study on simulated data for a particle detector used for proton computed tomography, the high potential as well as the competitiveness of our approach compared to a heuristic search algorithm and a model trained on ground truth. Finally, we point out limitations of our approach, guiding towards a robust foundation for further development of reinforcement learning based tracking.

4.
Acta Oncol ; 60(11): 1413-1418, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34259117

RESUMO

BACKGROUND: Proton computed tomography (pCT) and radiography (pRad) are proposed modalities for improved treatment plan accuracy and in situ treatment validation in proton therapy. The pCT system of the Bergen pCT collaboration is able to handle very high particle intensities by means of track reconstruction. However, incorrectly reconstructed and secondary tracks degrade the image quality. We have investigated whether a convolutional neural network (CNN)-based filter is able to improve the image quality. MATERIAL AND METHODS: The CNN was trained by simulation and reconstruction of tens of millions of proton and helium tracks. The CNN filter was then compared to simple energy loss threshold methods using the Area Under the Receiver Operating Characteristics curve (AUROC), and by comparing the image quality and Water Equivalent Path Length (WEPL) error of proton and helium radiographs filtered with the same methods. RESULTS: The CNN method led to a considerable improvement of the AUROC, from 74.3% to 97.5% with protons and from 94.2% to 99.5% with helium. The CNN filtering reduced the WEPL error in the helium radiograph from 1.03 mm to 0.93 mm while no improvement was seen in the CNN filtered pRads. CONCLUSION: The CNN improved the filtering of proton and helium tracks. Only in the helium radiograph did this lead to improved image quality.


Assuntos
Telescópios , Humanos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Redes Neurais de Computação , Imagens de Fantasmas , Radiografia
5.
Opt Express ; 22(11): 12971-81, 2014 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-24921494

RESUMO

Numerical optimization of photonic devices is often limited by a large design space the finite-differences gradient method requires as many electric field computations as there are design parameters. Adjoint-based optimization can deliver the same gradients with only two electric field computations. Here, we derive the relevant adjoint formalism and illustrate its application for a waveguide slab, and for the design of optical sub-wavelength gratings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA