Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Integr Mater Manuf Innov ; 12(1): 52-69, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36873293

RESUMO

In this paper, a part-scale simulation study on the effects of bi-directional scanning patterns (BDSP) on residual stress and distortion formation in additively manufactured Nitinol (NiTi) parts is presented. The additive manufacturing technique of focus is powder bed fusion using a laser beam (PBF-LB), and simulation was performed using Ansys Additive Print software. The numerical approach adopted in the simulation was based on the isotropic inherent strain model, due to prohibitive material property requirements and computational limitations of full-fledged part-scale 3D thermomechanical finite element approaches. In this work, reconstructed 2D and 3D thermograms (heat maps) from in situ melt pool thermal radiation data, the predicted residual stresses, and distortions from the simulation study were correlated for PBF-LB processed NiTi samples using selected BDSPs. The distortion and residual stress distribution were found to vary greatly between BDSPs with no laser scan vector rotations per new layer, whereas negligible variations were observed for BDSPs with laser scan vector rotations per new layer. The striking similarities between the reconstructed thermograms of the first few layers and the simulated stress contours of the first lumped layer provide a practical understanding of the temperature gradient mechanism of residual stress formation in PBF-LB processed NiTi. This study provides a qualitative, yet practical insight towards understanding the trends of formation and evolution of residual stress and distortion, due to scanning patterns.

2.
Materials (Basel) ; 15(9)2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35591324

RESUMO

Every year, the EU emits 13.4 Mt of CO2 solely from plastic production, with 99% of all plastics being produced from fossil fuel sources, while those that are produced from renewable sources use food products as feedstocks. In 2019, 29 Mt of plastic waste was collected in Europe. It is estimated that 32% was recycled, 43% was incinerated and 25% was sent to landfill. It has been estimated that life-sciences (biology, medicine, etc.) alone create plastic waste of approximately 5.5 Mt/yr, the majority being disposed of by incineration. The vast majority of this plastic waste is made from fossil fuel sources, though there is a growing interest in the possible use of bioplastics as a viable alternative for single-use lab consumables, such as petri dishes, pipette tips, etc. However, to-date only limited bioplastic replacement examples exist. In this review, common polymers used for labware are discussed, along with examining the possibility of replacing these materials with bioplastics, specifically polylactic acid (PLA). The material properties of PLA are described, along with possible functional improvements dure to additives. Finally, the standards and benchmarks needed for assessing bioplastics produced for labware components are reviewed.

3.
Microsyst Nanoeng ; 2: 16008, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-31057817

RESUMO

For the first time, we harness the unique phase-selectivity of chip-integrated graphene oxide (GO) membranes to significantly enhance flow control on centrifugal microfluidic platforms. In this paper, we present novel processes for the assembly of these GO membranes into polymeric microfluidic systems and demonstrate that multilayer GO membranes allow the passage of water while blocking pressurized air and organic solutions.

4.
Sensors (Basel) ; 13(9): 11336-49, 2013 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-24064595

RESUMO

This paper demonstrates the full centrifugal microfluidic integration and automation of all liquid handling steps of a 7-step fluorescence-linked immunosorbent assay (FLISA) for quantifying nitrate and nitrite levels in whole blood within about 15 min. The assay protocol encompasses the extraction of metered plasma, the controlled release of sample and reagents (enzymes, co-factors and fluorescent labels), and incubation and detection steps. Flow control is implemented by a rotationally actuated dissolvable film (DF) valving scheme. In the valves, the burst pressure is primarily determined by the radial position, geometry and volume of the valve chamber and its inlet channel and can thus be individually tuned over an extraordinarily wide range of equivalent spin rates between 1,000 RPM and 5,500 RPM. Furthermore, the vapour barrier properties of the DF valves are investigated in this paper in order to further show the potential for commercially relevant on-board storage of liquid reagents during shelf-life of bioanalytical, ready-to-use discs.


Assuntos
Bioensaio/instrumentação , Técnicas Biossensoriais/instrumentação , Centrifugação/instrumentação , Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Nitratos/sangue , Nitritos/sangue , Absorção , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Membranas Artificiais , Pressão , Reprodutibilidade dos Testes , Robótica/instrumentação , Sensibilidade e Especificidade
5.
Lab Chip ; 12(23): 5069-78, 2012 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-23070147

RESUMO

This work describes the first use of a wireless paired emitter detector diode device (PEDD) as an optical sensor for water quality monitoring in a lab-on-a-disc device. The microfluidic platform, based on an ionogel sensing area combined with a low-cost optical sensor, is applied for quantitative pH and qualitative turbidity monitoring of water samples at point-of-need. The autonomous capabilities of the PEDD system, combined with the portability and wireless communication of the full device, provide the flexibility needed for on-site water testing. Water samples from local fresh and brackish sources were successfully analysed using the device, showing very good correlation with standard bench-top systems.

6.
Lab Chip ; 12(16): 2894-902, 2012 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-22692574

RESUMO

In this article we introduce a novel technology that utilizes specialized water dissolvable thin films for valving in centrifugal microfluidic systems. In previous work (William Meathrel and Cathy Moritz, IVD Technologies, 2007), dissolvable films (DFs) have been assembled in laminar flow devices to form efficient sacrificial valves where DFs simply open by direct contact with liquid. Here, we build on the original DF valving scheme to leverage sophisticated, merely rotationally actuated vapour barriers and flow control for enabling comprehensive assay integration with low-complexity instrumentation on "lab-on-a-disc" platforms. The advanced sacrificial valving function is achieved by creating an inverted gas-liquid stack upstream of the DF during priming of the system. At low rotational speeds, a pocket of trapped air prevents a surface-tension stabilized liquid plug from wetting the DF membrane. However, high-speed rotation disrupts the metastable gas/liquid interface to wet the DF and thus opens the valve. By judicious choice of the radial position and geometry of the valve, the burst frequency can be tuned over a wide range of rotational speeds nearly 10 times greater than those attained by common capillary burst valves based on hydrophobic constrictions. The broad range of reproducible burst frequencies of the DF valves bears the potential for full integration and automation of comprehensive, multi-step biochemical assay protocols. In this report we demonstrate DF valving, discuss the biocompatibility of using the films, and show a potential sequential valving system including the on-demand release of on-board stored liquid reagents, fast centrifugal sedimentation and vigorous mixing; thus providing a viable basis for use in lab-on-a-disc platforms for point-of-care diagnostics and other life science applications.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Centrifugação , Desenho de Equipamento , Gases/química , Interações Hidrofóbicas e Hidrofílicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA