Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Acute Cardiovasc Care ; 11(11): 834-840, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36179255

RESUMO

AIMS: After rule-out of non-ST elevation myocardial infarction (NSTEMI) with the European Society of Cardiology (ESC) 0/1 h-algorithms, it is unclear which patients require further anatomical or functional cardiac testing. To test the safety and efficacy of the no-objective-testing (NOT)-rules after NSTEMI rule-out by the ESC 0/1 h-algorithms. METHODS AND RESULTS: International, prospective, diagnostic multicentre study enrolling adult patients presenting with chest pain to the emergency department. Central adjudication of final diagnosis by two independent cardiologists using information including cardiac imaging. Primary endpoints were the safety and efficacy of the NOT-rules for the rule-out of major adverse cardiovascular events (MACE). Secondary endpoints included 365-day and 2-year MACE. Among 4804 and 4569 patients with available 0/1 h high-sensitivity cardiac troponin (hs-cTn)T-Elecsys or hs-cTnI-Architect concentrations, 2783 (58%) and 2252 (49%) were eligible for application of the NOT-rules after rule-out of NSTEMI by the ESC hs-cTnT/I-0/1h-algorithm. The first rule identified 26% of patients with a sensitivity of 100% (95%CI 98.3-100%) and a negative predictive value (NPV) of 100% (95% CI, n.c.). The second and third rules both identified 31% of patients with a sensitivity of 99.5% (95% CI 97.4-99.9%) and a NPV of 99.9% (95% CI 99.2-99.9%). Similar findings emerged for hs-cTnI. High safety was confirmed for rule-out of 365-day and 2-year MACE and proven to be superior to the HEART Score. CONCLUSION: All three NOT-rules performed very well for rule-out of MACE. The third NOT-rule best balanced feasibility, safety, and efficacy by identifying nearly one out of three patients as low-risk and may not require further cardiac testing. https://clinicaltrials.gov/ct2/show/NCT00470587.


Assuntos
Cardiologia , Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Adulto , Humanos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Estudos Prospectivos , Infarto do Miocárdio/diagnóstico , Troponina I , Algoritmos , Biomarcadores , Troponina T
3.
Circulation ; 144(10): 773-787, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34376064

RESUMO

BACKGROUND: The non-ST-segment-elevation myocardial infarction (NSTEMI) guidelines of the European Society of Cardiology (ESC) recommend a 3h cardiac troponin determination in patients triaged to the observe-zone of the ESC 0/1h-algorithm; however, no specific cutoff for further triage is endorsed. Recently, a specific cutoff for 0/3h high-sensitivity cardiac troponin T (hs-cTnT) change (7 ng/L) was proposed, warranting external validation. METHODS: Patients presenting with acute chest discomfort to the emergency department were prospectively enrolled into an international multicenter diagnostic study. Final diagnoses were centrally adjudicated by 2 independent cardiologists applying the fourth universal definition of myocardial infarction, on the basis of complete cardiac workup, cardiac imaging, and serial hs-cTnT. Hs-cTnT concentrations were measured at presentation, after 1 hour, and after 3 hours. The objective was to externally validate the proposed cutoff, and if necessary, derive and internally as well as externally validate novel 0/3h-criteria for the observe-zone of the ESC 0/1h-hs-cTnT-algorithm in an independent multicenter cohort. RESULTS: Among 2076 eligible patients, application of the ESC 0/1h-hs-cTnT-algorithm triaged 1512 patients (72.8%) to either rule out or rule in NSTEMI, leaving 564 patients (27.2%) in the observe-zone (adjudicated NSTEMI prevalence, 120/564 patients, 21.3%). The suggested 0/3h-hs-cTnT-change of <7 ng/L triaged 517 patients (91.7%) toward rule-out, resulting in a sensitivity of 33.3% (95% CI, 25.5-42.2), missing 80 patients with NSTEMI, and ≥7 ng/L triaged 47 patients toward rule-in (8.3%), resulting in a specificity of 98.4% (95% CI, 96.8-99.2). Novel derived 0/3h-criteria for the observe-zone patients ruled out NSTEMI with a 3h hs-cTnT concentration <15 ng/L and a 0/3h-hs-cTnT absolute change <4 ng/L, triaging 138 patients (25%) toward rule-out, resulting in a sensitivity of 99.2% (95% CI, 96.0-99.9), missing 1 patient with NSTEMI. A 0/3h-hs-cTnT absolute change ≥6 ng/L triaged 63 patients (11.2%) toward rule-in, resulting in a specificity of 98% (95% CI, 96.2-98.9) Thereby, the novel 0/3h-criteria reduced the number of patients in the observe zone by 36%s and the number of type 1 myocardial infarction by 50%. Findings were confirmed in both internal and external validation. CONCLUSIONS: A combination of a 3h-hs-cTnT concentration (<15 ng/L) and a 0/3h absolute change (<4 ng/L) is necessary to safely rule out NSTEMI in patients remaining in the observe-zone of the ESC 0/1h-hs-cTnT-algorithm. Registration: URL: https://clinicaltrials.gov; Unique identifier: NCT00470587.


Assuntos
Algoritmos , Sistema Cardiovascular/fisiopatologia , Infarto do Miocárdio/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Técnicas de Imagem Cardíaca/métodos , Cardiologia/métodos , Coleta de Dados , Testes Diagnósticos de Rotina/efeitos adversos , Coração/fisiopatologia , Humanos , Infarto do Miocárdio/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA