1.
Injury ; 53(10): 3543-3552, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35810043

RESUMO

Treatment of comminuted intraarticular calcaneal fractures remains controversial and challenging. The aim of this study was to investigate the biomechanical performance of three different methods for fixation of such fractures. Comminuted calcaneal fractures, including Sanders III AB fracture of the posterior facet and Kinner II B fracture of the calcaneocuboid joint (CCJ) articular calcaneal surface, were created in 18 human cadaveric lower legs by osteotomizing. The ankle joint, medial soft tissues and midtarsal bones along with their ligaments were preserved. The specimens were randomized to three groups for fixation with either (1) 2.7 mm variable-angle locking lateral calcaneal plate (Group 1), (2) 2.7 mm variable-angle locking anterolateral calcaneal plate in combination with one 4.5 mm and one 6.5 mm cannulated screws (Group 2), or (3) interlocking calcaneal nail with 3.5 mm screws in combination with three separate 4.0 mm cannulated screws (Group 3). All specimens were biomechanically tested to failure under axial loading in midstance foot position. Each test commenced with a quasi-static compression ramp from 50 to 200 N, followed by progressively increasing cyclic loading at 2 Hz. Starting from 200 N, the peak load of each cycle increased at a rate of 0.2 N/cycle. Interfragmentary movements were captured by motion tracking. In addition, mediolateral X-rays were taken every 250 cycles with a triggered C-arm. Böhler angle after 5000 cycles (1200 N peak load) increased significantly more in Group 1 compared to both other groups (P ≤ 0.020). Varus deformation of 10° between the calcaneal tuberosity and the lateral calcaneal fragments was reached at significantly lower number of cycles in Group 1 compared the other groups (P ≤ 0.017). Both cycles to 10° plantar gapping between the anterior process and the calcaneal tuberosity fragments, and 2 mm displacement at the CCJ articular calcaneal surface revealed no significant differences among the groups (P ≥ 0.773). From a biomechanical perspective, treatment of comminuted intraarticular calcaneal fractures using anterolateral variable-angle locking plate with additional longitudinal screws or interlocked nail in combination with separate transversal screws provides superior stability as opposed to lateral variable-angle locked plating only.


Assuntos
Traumatismos do Tornozelo , Calcâneo , Fixação Intramedular de Fraturas , Fraturas Ósseas , Fraturas Cominutivas , Fraturas Intra-Articulares , Traumatismos do Joelho , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Calcâneo/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Humanos , Fraturas Intra-Articulares/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia
2.
Arch Orthop Trauma Surg ; 142(4): 579-590, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33174612

RESUMO

INTRODUCTION: Non-unions remain a clinical problem and are characterised by the failure to heal after a defined period of time. Current preclinical non-union models apply a wide variety of techniques to diminish intrinsic healing potential deviating from the clinical situation. The aim of this study was to develop and characterise a non-union model in rats using internal plate fixation without the need for additional healing insults, whereby bone healing can be longitudinally assessed using microCT. It was hypothesized that healing/non-unions can be accurately predicted at early time points by microCT. MATERIALS AND METHODS: Female, skeletally mature Fischer F344 rats received a 2 mm or 1 mm femoral osteotomy, stabilized with either a 2 mm thick plate or a 1.25 mm thick plate. Healing was monitored by microCT over 14 weeks and histological analysis at euthanasia. The mechanical environment was characterised using finite element (FE) modelling and biomechanical testing. RESULTS: The majority of animals receiving the 2 mm thick plate displayed poor healing responses in both the 2 mm and 1 mm defect size groups. Bone and cartilage formation were markedly improved using the 1.25 mm thick plate. MicroCT could accurately predict bone forming capacity at early time points (3-4 weeks). CONCLUSIONS: The 2 mm thick plating system confers poor healing responses in female Fischer F344 rats, comparable to atrophic non-unions. By reducing plate thickness to increase interfragmentary strain within the defect site healing is improved, leading to borderline healing situations or increased abundance of cartilage tissue present in the defect site with ultimate failure to bridge the defect (hypertrophic non-union). Furthermore, microCT can reliably identify delayed/non-healing animals within 4 weeks, thereby allowing their selective targeting for the testing of novel, clinically relevant treatment strategies in different clinical situations aimed at restoring impaired bone healing.


Assuntos
Placas Ósseas , Consolidação da Fratura , Animais , Feminino , Fixação Interna de Fraturas/métodos , Consolidação da Fratura/fisiologia , Ratos , Ratos Endogâmicos F344 , Microtomografia por Raio-X
3.
BMC Musculoskelet Disord ; 22(1): 371, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33879133

RESUMO

BACKGROUND: With regard to biomechanical testing of orthopaedic implants, there is no consensus on whether artificial creation of standardized bone fractures or their simulation by means of osteotomies result in more realistic outcomes. Therefore, the aim of this study was to artificially create and analyze in an appropriate setting the biomechanical behavior of standardized stable pertrochanteric fractures versus their simulation via osteotomizing. METHODS: Eight pairs of fresh-frozen human cadaveric femora aged 72.7 ± 14.9 years (range 48-89 years) were assigned in paired fashion to two study groups. In Group 1, stable pertrochanteric fractures AO/OTA 31-A1 were artificially created via constant force application on the anterior cortex of the femur through a blunt guillotine blade. The same fracture type was simulated in Group 2 by means of osteotomies. All femora were implanted with a dynamic hip screw and biomechanically tested in 20° adduction under progressively increasing physiologic cyclic axial loading at 2 Hz, starting at 500 N and increasing at a rate of 0.1 N/cycle. Femoral head fragment movements with respect to the shaft were monitored by means of optical motion tracking. RESULTS: Cycles/failure load at 15° varus deformation, 10 mm leg shortening and 15° femoral head rotation around neck axis were 11324 ± 848/1632.4 ± 584.8 N, 11052 ± 1573/1605.2 ± 657.3 N and 11849 ± 1120/1684.9 ± 612.0 N in Group 1, and 10971 ± 2019/1597.1 ± 701.9 N, 10681 ± 1868/1568.1 ± 686.8 N and 10017 ± 4081/1501.7 ± 908.1 N in Group 2, respectively, with no significant differences between the two groups, p ≥ 0.233. CONCLUSION: From a biomechanical perspective, by resulting in more consistent outcomes under dynamic loading, standardized artificial stable pertrochanteric femur fracture creation may be more suitable for orthopaedic implant testing compared to osteotomizing the bone.


Assuntos
Ortopedia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fixação Interna de Fraturas , Humanos , Pessoa de Meia-Idade , Osteotomia
4.
Unfallchirurg ; 117(10): 946-56, 2014 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-25274391

RESUMO

BACKGROUND: Since 2004 the German diagnosis-related groups (DRG) system has been applied nationwide in all German somatic hospitals. The G-DRG system is updated annually in order to increase the quality of case allocation. What developments have occurred since 2004 from the perspective of orthopedics and trauma surgery? This article takes stock of the developments between 2004 and 2014. METHODS: Analysis of relevant diagnoses, medical procedures and G-DRGs in the versions 2004 and 2014 based on the publications of the German DRG Institute (InEK) and the German Institute of Medical Documentation and Information (DIMDI). RESULTS: The number of G-DRGs in the whole system increased by 45.1 % between 2004 and 2014. The number of G-DRGs in the major diagnostic category (MDC) 08 that contains the majority of orthopedic and trauma surgery categories increased in the same period by 61.6 %. The reduction of variance of inlier costs in the MDC 08 category, a statistical measure of the performance of the G-DRG system, was below the corresponding value of the total system in 2004 as well in 2014. However, the reduction of variance of inlier costs in MDC 08 (+ 30.0 %) rose more from 2004 to 2014 than the corresponding value of the overall system (+ 21.5 %). CONCLUSION: Many modifications of the classification systems of diagnoses (ICD-10-GM) and medical procedures (OPS) and the structures of the G-DRG system could significantly improve the quality of case allocation from the perspective of orthopedics and trauma surgery between 2004 and 2014. Th assignment of cases could be differentiated so that complex cases with more utilization of resources were allocated to higher rated G-DRGs and vice versa. However, further improvements of the G-DRG system are necessary. Only correct and complete documentation and coding can provide a high quality of calculation of costs as a basis for a correct case allocation in future G-DRG systems.


Assuntos
Administração de Caso/economia , Grupos Diagnósticos Relacionados/economia , Grupos Diagnósticos Relacionados/estatística & dados numéricos , Procedimentos Ortopédicos/economia , Procedimentos Ortopédicos/estatística & dados numéricos , Ferimentos e Lesões/epidemiologia , Ferimentos e Lesões/cirurgia , Administração de Caso/estatística & dados numéricos , Grupos Diagnósticos Relacionados/tendências , Alemanha/epidemiologia , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Procedimentos Ortopédicos/tendências , Prevalência
5.
Bone Joint J ; 95-B(10): 1406-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24078541

RESUMO

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (sd 0.08) vs augmented 0.13 mm (sd 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (sd 0.02) vs augmented 0.15 mm (sd 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017).


Assuntos
Cimentos Ósseos , Placas Ósseas , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas por Osteoporose/cirurgia , Fraturas do Fêmur/fisiopatologia , Fixação Interna de Fraturas/instrumentação , Humanos , Teste de Materiais/métodos , Modelos Anatômicos , Fraturas por Osteoporose/fisiopatologia , Distribuição Aleatória , Estresse Mecânico