RESUMO
Popliteal artery entrapment syndrome (PAES) is still underdiagnosed yet it may significantly interfere with lifestyle, especially among young sportspeople, with symptoms like intermittent claudication. Although case reports and small case series are sometimes published, studies with larger populations are quite rare. This study summarizes our experience with PAES on 61 limbs (35 patients) over a period of 11 years, describing the demographics, the disease, and the diagnostic and therapeutic methods used with PAES patients. In a population of 327 consecutive explored symptomatic sportspersons, PAES was confirmed in 35 patients on 61 pathologic limbs. The median time with the symptoms before diagnosis was 34 months (range, 3-180 months). The mean age of patients was 30.5 years (range, 17-52 years) with 83% of males. The proportion of patients diagnosed with bilateral PAES was 74%. The main sports practiced were running (15 patients, 43%), soccer (nine patients, 26%), rugby (two patients), and athletics (two patients). Among 21 patients, intra-compartmental pressure measurements (ICP) found 18 (86%) to have an associated chronic exertional compartment syndrome (CECS). Among the patients followed up after PAES surgery, 80% were able to resume sport at a level comparable to that before the onset of pain. PAES could be sought earlier in young sportspeople who experience unexplained leg pain during exercise to diagnose the disease and avoid complications in a timely manner. Compartmental pressures should systematically be measured in the search for an associated CECS.
Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/cirurgia , Artéria Poplítea/patologia , Adolescente , Adulto , Atletas , Constrição Patológica/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/cirurgia , Adulto JovemRESUMO
In order to better understand the risk factors and behaviour of a general sports population, a questionnaire was handed to 603 consecutive sportsmen of various disciplines during a specific sports medicine consultation and a half-marathon. Among the discovered risk factors, smoking was the most common (19.3% for the entire study population), predominantly in the youngest group (26%). A resting ECG had been performed very frequently within the previous year in those over 40 years (86.5%), but less often in the younger sportsmen (44.8%). An exercise test had also very often been performed in those aged over 40 years (69.2 vs 10.6%). Behaviour associated with cardiovascular risk was common. Undertaking physical activity while febrile (58%) and smoking just before or after exertion (13.1%) were widespread behaviours. This population appeared casual in its approach to possibly suspicious cardiac symptoms of exercise, particularly the females and paradoxically the subjects doing the most sport. Lastly, only a minority of sportsmen knew the telephone number for the emergency medical service (45%) or claimed to be competent at first aid (32%). This survey underlines a practice relatively in accordance with the recommendations for detecting cardiovascular pathology, but shows a failure of preventive education.
Assuntos
Doenças Cardiovasculares/prevenção & controle , Comportamentos Relacionados com a Saúde , Esportes/fisiologia , Adulto , Distribuição por Idade , Feminino , Febre/fisiopatologia , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Assunção de Riscos , Distribuição por Sexo , Fumar/epidemiologia , Inquéritos e QuestionáriosRESUMO
The relation between left ventricular electromechanical delay and the acute hemodynamic effect of right ventricular pacing was studied in heart failure patients with and without complete left bundle branch block. Whereas right ventricular pacing provided a shorter electromechanical delay that correlated with an improvement in left ventricular function in patients with left bundle branch block, the converse was observed in patients without left bundle branch block.
Assuntos
Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/fisiopatologia , Função Ventricular Esquerda , Bloqueio de Ramo/complicações , Estudos Cross-Over , Feminino , Insuficiência Cardíaca/complicações , Hemodinâmica , Humanos , Masculino , Ventriculografia com RadionuclídeosRESUMO
We evaluated the effect of atrial overdrive on the incidence of atrial arrhythmias (AA) in 22 patients (67 +/- 9 years, 7 women, 15 men) with Chorus 6234 DDD pacemakers. Atrial overdrive was defined as a programmed paced rate 10 ppm faster than the mean ventricular rate stored for the last 24-hour period in the pacemaker memory. The protocol consisted of three phases of 1 month each. Phase I: observation after discontinuation of antiarrhythmic therapy. Phase II: arrhythmia analysis using the pacemaker memory after programming the lower rate to 55 ppm. The fallback function and histogram data were used to document the number and maximal duration of AA episodes as well as the total AA time in a month. Phase III: atrial overdrive. The mean ventricular heart rate was 65 +/- 4 beats/min before atrial overdrive versus 75 +/- 5 with atrial overdrive (P = 0.02). At the end of phase II, all patients presented with AA episodes (mean number per patient: 42 +/- 78 in one month). In phase III (with atrial overdrive), 14 (64.6%) patients had no recorded AA (group A). In the other eight patients with persistent AA episodes in phase III (group B), there was a significant reduction in the number of AA episodes (90 +/- 106 in phase II vs 38 +/- 87 in phase III; P = 0.01), their total duration (166 +/- 115 in phase II vs 92 +/- 134 hours in phase III; P = 0.03) and their maximal duration (121 +/- 103 in phase II vs 85 +/- 89 min; P = 0.04). Our short-term data suggest that atrial overdrive prevents or reduces AA episodes and demonstrate the feasibility and need of long-term studies to determine whether this benefit is sustained.
Assuntos
Marca-Passo Artificial , Taquicardia Supraventricular/prevenção & controle , Idoso , Eletrocardiografia/instrumentação , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Assistência de Longa Duração , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador/instrumentação , Software , Taquicardia Supraventricular/fisiopatologiaRESUMO
To optimize programming of rate adaptive pacemakers (RAPs), we explored a new mathematical method to assess the performance of RAPs during daily-life tests, using customized Windows-based software. By stepwise discriminant analysis and linear regression, this method allows calculation of the acceleration and deceleration capacity of pacemakers and their general behavior during effort and recovery phases. Twenty-three patients (10 females and 13 males; 68 +/- 8 years) with chronic atrial fibrillation and a slow ventricular response were evaluated. They randomly received an accelerometer-controlled VVIR Dash Intermedics pacemaker (10 patients) or a vibration piezoelectric-controlled VVIR Sensolog III Siemens pacemaker (13 patients). All patients underwent the same test protocol: 6 minutes walking, 1.5 minutes climbing stairs, 1.5 minutes descending stairs, and 0.5 minutes sit-ups. By definition, the pacemaker responsiveness slope was programmed so that the heart rate response of paced patients during the walking test corresponded best to that of healthy controls. The slope was left unchanged for the other tests. We considered four scores: an acceleration score (EA score), an effort rate score (ER score), a deceleration score (RD score), and a recovery rate score (RR score). Scores ranged from -10 (hypochronotropic behavior of the pacemaker) to +10 (hyperchronotropic behavior), based on daily-life tests of 15 healthy controls (7 females and 8 males, 65 +/- 9 years). A score of 0 represented exact concordance with healthy controls. During stair descent, the Sensolog III produced excessive acceleration (EA score = +2.9 +/- 1.1) compared to: (1) stair climbing (EA score = -4.0 +/- 1.9; P = 0.01, with the same pacemakers); and (2) the Dash (+1.8 +/- 1.9; P = 0.04) and healthy controls (P = 0.02). The sit-up tests revealed a hypochronotropic response of both pacemakers compared to healthy controls, with a larger difference for the Sensolog III (EA score = -2.0 +/- 5.8; P = 0.04; RD score = -6.8 +/- 3.8' P = 0.02). We conclude that activity-driven pacemakers can accommodate brief activities, except for isovolumetric exercise such as sit-ups. During daily activities, accelerometer-driven pacemakers seem to provide a heart rate resoibse closer to that of healthy controls. Our new mathematical analysis is a simple and reproducible method for evaluating and quantifying the efficacy of any sensor-driven pacemaker.
Assuntos
Fibrilação Atrial/terapia , Ritmo Circadiano/fisiologia , Marca-Passo Artificial/normas , Adaptação Fisiológica , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Doença Crônica , Impedância Elétrica , Eletrocardiografia , Exercício Físico/fisiologia , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Masculino , Matemática , Pessoa de Meia-Idade , Análise de RegressãoRESUMO
BACKGROUND: Atrial fibrillation is usually thought to be due to multiple circulating reentrant wavelets. From previous studies, a focal mechanism is considered to be very unlikely. In this report, focal atrial fibrillation is defined on an ECG pattern of atrial fibrillation and later demonstrated to be due to a focal source. METHODS AND RESULTS: Nine patients (five men and four women, age, 38 +/- 7 years) with paroxysmal focal atrial fibrillation are reported here. All were free of structural heart disease and had frequent episodes of atrial fibrillation despite the use of a mean of 4 +/- 2 antiarrhythmic drugs. Atrial fibrillation was associated with runs of irregular atrial tachycardia or monomorphic extrasystoles. The electrophysiological study demonstrated that all the atrial arrhythmias were due to the same focus firing irregularly and exhibiting a consistent and centrifugal pattern of activation. Three foci were found to be located in the right atrium, two near the sinus node and one in the ostium of the coronary sinus. Six others were located in the left atrium at the ostium of the right pulmonary veins (n = 5) and at the ostium of the left superior pulmonary vein (n = 1). All atrial arrhythmias were successfully treated by use of a mean of 4 +/- 4 radiofrequency pulses. CONCLUSIONS: In some patients, the surface ECG pattern of atrial fibrillation is due to a focal rapidly firing source of activity that can be eliminated by discrete radiofrequency energy applications.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Adulto , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , ReoperaçãoRESUMO
INTRODUCTION: Atrial fibrillation (AF), the most common arrhythmia, is due to multiple simultaneous wavelets of reentry in the atria. The only available curative treatment is surgical, using atriotomies to compartmentalize the atria. Therefore, we investigated a staged anatomical approach using radiofrequency catheter ablation lines to prevent paroxysmal AF. METHODS AND RESULTS: Forty-five patients with frequent symptomatic drug-refractory episodes of paroxysmal AF were studied. Progressively complex linear lesions were created by sequential applications of radiofrequency current in the right atrium and then in the left atrium if required. The outcome of the procedure was considered a success when the episodes of AF were either eliminated or recurred at a rate of no more than one episode (lasting < 6 hours) in 3 months. Patients who had no more than one episode per month were considered "improved." Right atrial ablation organized local electrical activity and led to stable sinus rhythm during the procedure in 18 (40%) of the 45 patients. However, sustained AF remained inducible in 40 of 45 patients, and the lesions failed to produce evidence of a significant linear conduction block/delay in all but four patients. There were no significant complications except for two transient sinus node dysfunctions. The procedure duration and fluoroscopic time were 248 +/- 79 and 53 +/- 22 min, respectively. Additional sessions were required in 19 patients to treat sustained right atrial flutter or arrhythmias linked to ectopic right or left atrial foci. During a mean follow-up of 11 +/- 4 months, right atrial ablation was successful in 15 (33%) patients, 6 without medication and 9 with a previously ineffective drug. Nine (20%) additional patients were improved. Ten patients with an unsuccessful outcome then underwent linear ablation in the left atrium. The procedure duration and fluoroscopy time were 292 +/- 94 and 66 +/- 24 min. A hemopericardium occurred in one patient. Two patients required reablation to treat ectopic atrial foci. Left atrial ablation terminated AF during the procedure in 8 patients, and sustained AF could not be induced in 5. Subsequent success was achieved in 6 (60%) patients, including 4 without medication, and 1 additional patient was improved. CONCLUSIONS: Successful radiofrequency catheter ablation of drug-refractory daily paroxysmal AF is feasible using linear atrial lesions complemented by focal ablation targeted at arrhythmogenic foci. Ablation only in the right atrium is a safe technique providing limited success, whereas linear lesions in the left atrium significantly increase the incidence of stable restoration of sinus rhythm, the inability to induce sustained AF, and the final success rate. The described technique is promising but must be considered preliminary because significant improvements are required to optimize lesion characteristics and shorten total procedure duration.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Taquicardia Paroxística/cirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Paroxística/diagnóstico por imagem , Taquicardia Paroxística/fisiopatologia , Resultado do TratamentoRESUMO
INTRODUCTION: The purpose of this study was to evaluate the efficacy and safety of radiofrequency (RF) catheter ablation of common atrial flutter and to determine the optimum target sites in a large series of patients. Three different approaches were used to target the ablation site. The first used a combined anatomic and electrophysiologic approach, whereas the second and the third approaches relied primarily on anatomic guidelines to target the critical area in the atrial flutter reentrant circuit located in the low right atrium. BACKGROUND: Recent studies report the efficacy of RF current application in the low right atrial region to interrupt and prevent recurrences of common atrial flutter using either anatomic or electrophysiologic targets. However, larger groups of patients are required to confirm the efficacy of this technique and to specify the target sites. METHODS AND RESULTS: Two hundred consecutive patients with drug-resistant common atrial flutter were studied. In the first 50 patients, target sites were localized using both anatomic landmarks and electrophysiologic parameters. The anatomic landmarks were area 1 between the tricuspid valve and inferior vena cava orifice; area 2 between the tricuspid valve and coronary sinus ostium; and area 3 between the inferior vena and coronary sinus. The electrophysiologic criterion was to ablate when there was an atrial electrogram occurring during the plateau phase (preceding F wave). The first targeted area was that giving the more stable catheter position. In the following 30 patients, we assessed the effect of RF energy application in a single line to area 1 in the first 10 patients, area 2 in the next 10, and area 3 in the last 10 patients. In the last 120 patients, RF energy was applied only in area 1 using repeated applications. RF energy of 12 to 30 W, or that achieving a temperature of 70 degrees C, was applied for 60 to 90 seconds at each site. The endpoint of the ablation procedure was interruption and noninducibility of common atrial flutter in the first 110 patients and additional isthmal block in 48 of the last 90 patients. Overall, atrial flutter was interrupted and rendered noninducible after a single session in 191 (95%) patients and could not be interrupted in 9 (4.5%) patients. The mean number of RF applications was 12 +/- 8. After a mean follow-up of 24 +/- 9 months, recurrences occurred in 31 (15.5%) patients, 26 of whom underwent a successful second or third session without further recurrences of atrial flutter. Atrial fibrillation not documented before the ablation was detected in 11 patients. On a retrospective analysis of the final successful site in the first group of 50 patients, the location was in area 1 in 39% of patients; area 2 in 36% of patients, and area 3 in 25% of patients. Atrial electrograms recorded at these sites showed a single spike pattern in 46% of patients, and double spike pattern (28%) or fractioned electrogram in 26% patients. When lines of RF lesions were placed at several sites, they produced a success rate of 70%, 40%, and 10% at areas 1, 2, and 3 respectively. In the last series of 120 patients, the procedure was successful in 119 patients: 92% of whom were successfully treated only by a linear lesion between the tricuspid annulus isthmus and the inferior vena cava, and the other 8% by additional applications near the coronary sinus ostium. No complications were observed. CONCLUSIONS: RF catheter ablation of atrial flutter can be done with a high success rate and is safe. The highest success rate is achieved with RF energy applied in the isthmus between the inferior vena cava orifice and the tricuspid valve. However, 15.5% of patients need multiple sessions to achieve success because of recurrence of flutter. Further follow-up is needed to evaluate the long-term effects of this procedure.
Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Atrial arrhythmias (AA) are commonly encountered in DDD paced patients. Newer dual chamber pacemakers (PM) possess mode switching functions that convert pacing to an asynchronous mode when AAs are detected. The lack of a reliable mode switch leading to rapid, irregular ventricular responses may result from AA undersensing. To avoid this the DDDR PM Chorum 7234 Ela Medical AA diagnosis is based on a statistical approach: the PM constantly compares arrhythmic and sinus cycles and, based on "strong" and "weak" criteria, provides for rapid or slower mode switch. The aim of the study was to evaluate the efficiency and reliability of these two criteria. Thirty-one patients with a Chorum 7234 implanted for AV block (11), sinus dysfunction (10), both (5), or hypertrophic obstructive cardiomyopathy (5) were evaluated at 24 hours and 1 month using the internal memory (IM) of the PM, surface 24-hour Holter recordings, and exercise testing. Interrogation of the IM on the first day of study showed that 8 patients had mode switching episodes, based only on the strong criterion confirmed by the surface Holter recording. At 1 month, the IM revealed mode switching episodes in 12 patients, 6 of whom had used the weak criterion. No inappropriate mode switching episodes was recorded during exercise testing at the 1-month follow-up. These results confirm the reliability and efficiency of this algorithm as well as the requirement for a specific algorithm to compensate for transient loss of sensing during AA.
Assuntos
Arritmias Cardíacas/prevenção & controle , Função Atrial , Estimulação Cardíaca Artificial/métodos , Função Ventricular , Algoritmos , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/estatística & dados numéricos , Cardiomiopatia Hipertrófica/fisiopatologia , Eletrocardiografia Ambulatorial , Desenho de Equipamento , Teste de Esforço , Feminino , Seguimentos , Bloqueio Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Reprodutibilidade dos Testes , Síndrome do Nó Sinusal/fisiopatologia , Nó Sinoatrial/fisiologiaRESUMO
Radiofrequency (RF) catheter ablation is the curative treatment of choice for atrioventricular (AV) nodal reentrant tachycardia (AVNRT). Analogous to the development of surgical techniques, catheter ablation has evolved from AV nodal ablation to selective "fast" and "slow" pathway ablation. "Slow" ablation is now the method of choice because of the lower incidence of associated AV block. Though slow pathway ablation can be achieved with equal success using either the anatomic or the electrogram-guided approach, fewer applications of RF energy are required for the potential-guided technique.
Assuntos
Ablação por Cateter/métodos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Humanos , Resultado do TratamentoRESUMO
Ablation of the atrioventricular junction consists in creating a therapeutic AV block to facilitate the treatment of symptoms caused by atrial arrhythmias refractory to drug therapy. The technical performance of ablation has been improved by restricting the indication to atrial fibrillation, by using radiofrequency currents, by choosing a nodal rather than His bundle ablation site, and by improving the function of cardiac pacemakers (rate adapting, back-up). The functional results are excellent but the outcome is punctuated by rare cases of sudden death, the cause of which is not fully understood (dependance, ventricular arrhythmias, ...). To avoid permanent pacing, it has been suggested that atrioventricular conduction should be modulated rather than completely interrupted. Modulation of the fast pathway has been shown to be ineffective; that of the more complex, slow pathway, seems to be more promising. Although this obviates the need for a pacemaker, it does not suppress irregularity of the ventricular rhythm, the main cause of symptoms in paroxysmal atrial fibrillation and of the haemodynamic changes associated with permanent atrial fibrillation.
Assuntos
Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Taquicardia Supraventricular/cirurgia , Análise Atuarial , Adulto , Idoso , Nó Atrioventricular/fisiopatologia , Ablação por Cateter/efeitos adversos , Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Marca-Passo Artificial , Taquicardia Supraventricular/fisiopatologia , Resultado do TratamentoRESUMO
Atrioventricular nodal reentrant tachycardias which, for a long time, could only be treated medically, may now benefit from catheter ablation. The rapid retrograde pathway was an effective initial target but carried a risk of complete atrioventricular block of about 10%. Nowadays, most operators deliver the radiofrequency energy (endocavitary cautery) to the slow nodal pathway. Different techniques of guidance (anatomical, electrophysiological, rapid potential, slow potential) are associated with high success rates: 90 to 100%. However, experimental studies suggest that the slow potentials arise from transitional cells within the tachycardia circuit (the anatomical substrate of the slow pathway). There is still a risk of complete atrioventricular block (1 to 5%) which should be clearly explained to patients referred for ablation of this constantly benign arrhythmia.
Assuntos
Ablação por Cateter/métodos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fascículo Atrioventricular/patologia , Fascículo Atrioventricular/cirurgia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Seguimentos , Septos Cardíacos/fisiopatologia , Humanos , Recidiva , Bloqueio Sinoatrial/etiologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Resultado do TratamentoRESUMO
Endocavitary catheter ablation by radiofrequency energy applied on the slow pathway is an effective method of treatment of nodal reentrant tachycardias. The aim of this report was to determine the criteria predictive of success during radiofrequency ablation of the slow pathway guided by the presence of slow potentials. Thirty-five patients (21 women, 14 men, mean age 44 +/- 14 years) with frequent attacks of junctional tachycardia were studied. After confirmation of the diagnosis by electrophysiological investigation, radiofrequency energy was delivered at a site characterised by the presence of slow potentials between the atrial (A) and ventricular (V) potentials. The criteria investigated at each site were: before application: A/V ratio; amplitude of A and V: maximum A/minimum A ratio; amplitude and duration of the A potential; during ablation: radiological stability of the catheter position and occurrence of a junctional rhythm. All 35 patients had successful procedures with no inducible tachycardia at the end of the procedure. The slow pathway was destroyed in 20 cases (57%) with no complication of atrioventricular block. The duration of the A potential was longer in the successful cases (56 +/- 16 vs 48 +/- 14 ms; p = 0.04). The appearance of junctional rhythm and catheter stability during the procedure were predictive of success (79% vs 48%; p = 0.02; 74% vs 43%; p = 0.01). The authors concluded that an ablation site with a long duration A potential and a slow potential is a good target. In addition, ablation should be started when the catheter is radiologically stable and should not be interrupted in the absence of a junctional rhythm.
Assuntos
Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Adulto , Nó Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Bloqueio Cardíaco/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Ectópica de Junção/etiologia , Resultado do TratamentoRESUMO
Survival after His bundle ablation for supraventricular arrhythmias was analysed over 10 years (May 1982 to December 1992) in 312 consecutive patients (5 were lost to follow-up): 54 died (17.3%), 13 of sudden death (24%). The survival rates were 94.5% at 1 year (n = 256), 80.1% at 5 years (n = 88), 72.8% at 8 years (n = 20) and 51% at 10 years (n = 4); patients without apparent heart disease had a better prognosis. This series serves as a reference for other techniques of His bundle ablation.
Assuntos
Fascículo Atrioventricular/cirurgia , Ablação por Cateter/métodos , Taquicardia Supraventricular/cirurgia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Cardioversão Elétrica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Taxa de Sobrevida , Taquicardia Supraventricular/tratamento farmacológico , Taquicardia Supraventricular/mortalidade , Resultado do TratamentoRESUMO
OBJECTIVES: The purpose of this study was to evaluate the efficacy and safety of radiofrequency catheter ablation of common atrial flutter and to determine the optimal target sites in a large series of patients. BACKGROUND: Recent studies report the efficacy of radiofrequency current application in the low right atrial region to interrupt and prevent recurrences of common atrial flutter. However, larger groups of patients are required to confirm the efficacy of this technique and to specify the target sites. METHODS: Two different approaches were used to target the ablation site in 80 consecutive patients. In the first 50 patients, target sites were localized using both anatomic landmarks and electrophysiologic variables. Three anatomic landmarks were used: area 1 = between the tricuspid valve and inferior vena cava orifice; area 2 = between the tricuspid valve and coronary sinus ostium; area 3 = between the inferior vena cava and coronary sinus. The electrophysiologic criterion was to ablate when there was a stable atrial electrogram during the plateau phase. In the next 30 patients we assessed the effect of application of radiofrequency energy in a single line in area 1, 2 or 3 in groups of 10 patients. RESULTS: Overall atrial flutter was interrupted and rendered noninducible after a single session in 72 patients (90%) and could not be interrupted in 8 (10%). The mean (+/- SD) number of radiofrequency applications was 12 +/- 8. After a mean (+/- SD) follow-up of 20 +/- 8 months, recurrences occurred in 14 patients (17%). The location of the final successful site in the first group of 50 patients was in area 1 in 39%, area 2 in 36% and area 3 in 25%. In the next 30 patients, when lines of radiofrequency lesions were placed at several sites, they produced success rates of 70%, 40% and 10% at areas 1, 2 and 3, respectively. CONCLUSIONS: Radiofrequency catheter ablation of atrial flutter can be performed with a high success rate and is safe. The highest success rate is achieved with radiofrequency energy applied in the isthmus between the inferior vena cava orifice and tricuspid valve.
Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Análise Atuarial , Idoso , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Virilha , Hematoma/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , RecidivaRESUMO
BACKGROUND: Accessory pathways (APs) with anterograde decremental conduction properties referred to as Mahaim fibers have recently been recognized as originating from the right lateral atrium. Little information is available about their distal insertion. The purpose of this study was to determine the different kinds of APs involved and the characteristics of their distal insertion site. METHODS AND RESULTS: Twenty-one patients (mean age, 28 +/- 13 years) with reciprocating tachycardia or atrial fibrillation were studied. Right-sided atrial and/or ventricular endocardial mapping during tachycardia identified different types of APs. (1) Seventeen patients had long APs originating from the right lateral atrium and coursing several centimeters to the right ventricle. In 10 patients, the AP terminated in or close to the right bundle-branch system (atriofascicular AP) and in 7, the AP terminated in the anterior right ventricle (atrioventricular AP). Patients with atriofascicular APs had narrower QRS complexes (133 +/- 10 versus 165 +/- 26 milliseconds, P = .02) and narrower initial r wave in leads V2 through V4 during maximal preexcitation than patients with atrioventricular APs. In addition, they had earlier His-bundle and right bundle-branch retrograde activation, ie, shorter V-His (16 +/- 5 versus 37 +/- 9 milliseconds, P < .01) and V-right bundle intervals (3 +/- 5 versus 25 +/- 6 milliseconds, P < .01). In 6 patients, minimal preexcitation not readily apparent was present in sinus rhythm despite the appearance of a narrow QRS complex. A wide distal insertion site of 0.5 to 2 cm in diameter consistent with arborization of the AP was found in 10 patients. The distal application of radiofrequency current produced a change in the preexcitation pattern in 4 patients and ablated the AP in 2 patients. In the other patients, radiofrequency current was applied more proximally and successfully ablated the AP bundle (n = 9) or AP proximal insertion (n = 6). No recurrence was observed during a follow-up period of 12 +/- 10 months. (2) Four patients had short paratricuspid atrioventricular APs; in one, the decremental conduction property was acquired as demonstrated by two electrophysiological studies performed 7 years apart. Radiofrequency ablation was successfully accomplished in all 4 patients at the tricuspid annulus. CONCLUSIONS: Different types of APs account for tachycardias previously called Mahaim fibers. Long and short atrioventricular APs are observed in 81% and 19%, respectively. Long APs often have a distal arborization and may have either a fascicular or ventricular insertion. Radiofrequency current is more efficient when applied to the AP bundle or AP proximal insertion rather than to the distal insertion in patients with long APs.
Assuntos
Fibrilação Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Pré-Excitação Tipo Mahaim/fisiopatologia , Taquicardia Paroxística/fisiopatologia , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Bloqueio de Ramo/fisiopatologia , Estimulação Cardíaca Artificial , Ablação por Cateter , Eletrocardiografia , Feminino , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pré-Excitação Tipo Mahaim/diagnóstico , Pré-Excitação Tipo Mahaim/cirurgia , Taquicardia Paroxística/diagnóstico , Taquicardia Paroxística/cirurgiaRESUMO
The object of this study was to assess the efficacy and risks of radiofrequency ablation of common atrial flutter and to determine the optimal site of ablation in a large population of patients. Three different methods were used to determine the site of ablation: the first was anatomical and electrophysiological whilst the two others were based essentially on anatomical landmarks for localising the critical zone of the reentry circuit. Recent studies report that radiofrequency ablation is effective in interrupting and preventing recurrences of common atrial flutter both by using anatomical and electrophysiological methods. Nevertheless, a larger series of patients was necessary to establish the efficacy and to determine the optimal site of ablation. A series of 110 consecutive patients with common atrial flutter resistant to antiarrhythmic drugs was studied. The site of ablation of the first 50 patients was determined using both anatomical landmarks and electrophysiological parameters. The anatomical zones were: zone 1, between the septal leaflet of the tricuspid valve and the orifice of the inferior vena cava; zone 2, between the septal leaflet of the tricuspid valve and the ostium of the coronary sinus, and zone 3: between the orifice of the inferior vena cava and the ostium of the coronary sinus. The electrophysiological criterion was an endocavitary auriculogramme occurring during the plateau phase preceding the F wave of the flutter.(ABSTRACT TRUNCATED AT 250 WORDS)
Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Estudos de Avaliação como Assunto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do TratamentoRESUMO
INTRODUCTION: Catheter ablation of a case of incessant atrial fibrillation was attempted using linear right atrial lesions created by sequential applications of radiofrequency energy. METHODS AND RESULTS: A 46-year-old patient had incessant episodes of atrial fibrillation. He had previously undergone successful radiofrequency catheter ablation of a common atrial flutter. Antiarrhythmic drugs including amiodarone and various drug combinations were ineffective. A 7-French specially designed 14-polar catheter with interelectrode distance of 3 mm was used to create linear lesions in the right atrium. Each electrode was 4 mm in length and able to transmit radiofrequency energy. Three linear lesions, two longitudinal and one transverse that connected the two longitudinal lesions, were created using 30 radiofrequency applications of 10 to 40 W. The final application interrupted an atrial fibrillation that had been persistent for 55 minutes. No sustained atrial fibrillation was inducible despite repeated pacing maneuvers. There was no complication. In short-term follow-up of 3 months, the patient has been free of arrhythmias without antiarrhythmic medication. CONCLUSION: Successful catheter ablation of human atrial fibrillation is feasible using linear atrial lesions created by radiofrequency energy delivery. Further studies are mandatory to ascertain the efficacy and safety of this procedure, as well as to assess different catheter techniques.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
The introduction of ablative methods has revolutionised therapeutic strategy in cardiac arrhythmias. Accessory pathways are the most commonly targeted arrhythmogenic substrate. Several parameter may be used to determine the optimal site of ablation: accessory pathway potential, atrioventricular interval, atrial or ventricular pole of the pathway, morphology of the unipolar wave. The localisation of the accessory pathway sometimes requires specific techniques. The success rate reported in the literature is generally over 90%. However, the number of applications of radiofrequency current varies according to the authors from an average of three to eight. A combination of "timing related" criteria and direction of activation and the use of infraliminal stimuli minimise the number of radiofrequency applications. The incidence of complications in multicenter registers is 5% and the relapse rate is 8%. The long-term effects of catheter ablation are unknown, especially when used in childhood. A certain reserve should be maintained in the indications of ablation. Only high-risk, life-threatening arrhythmias, or those resistant to pharmacological intervention, are formal indications. Other (so-called "convenience") indications depend on the express wish of patients clearly informed of the advantages and risks of this method.
Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Humanos , RecidivaRESUMO
A retrospective study of 192 patients centered on the outcome of supraventricular arrhythmias after catheter ablation of the atrioventricular junction provided some useful information concerning the choice of pacing mode in these patients. With the exception of atrioventricular bloc after ablation of the rapid nodal pathway where simple DDD pacing is adequate, rate adaptive pacing would seem to be essential. The VVIR mode should be the mode of choice in atrial flutter, permanent atrial fibrillation, poorly controlled atrial fibrillation and paroxysmal atrial fibrillation of elderly subjects (over 70 years) and/or of male sex, and/or complicating advanced cardiac disease (valvular, ischaemic or primary). The DDDR mode (with an algorithm to prevent endless loop tachycardia) is the mode of choice in sinus node dysfunction and/or in young patients (under 60), and/or females and/or in idiopathic arrhythmias and/or when retrograde VA conduction persists. When the pacemaker is replaced, the indication should be reviewed with respect to the outcome of the arrhythmia, which underlines the value of accurate implanted Holter systems.