Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ultrasonics ; 88: 148-156, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29654961

RESUMO

In this paper, the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous cementitious materials is addressed. To accurately determine the attenuation over a wide frequency range, it is necessary to have suitable excitation techniques. We have analysed two kinds of ultrasound techniques: contact ultrasound and airborne non-contact ultrasound. The mathematical formulation for frequency-dependent attenuation has been established and it has been revealed that each technique may achieve similar results but requires specific different calibration processes. In particular, the airborne non-contact technique suffers high attenuation due to energy losses at the air-material interfaces. Thus, its bandwidth is limited to low frequencies but it does not require physical contact between transducer and specimen. In contrast, the classical contact technique can manage higher frequencies but the measurement depends on the pressure between the transducer and the specimen. Cement specimens have been tested with both techniques and frequency attenuation dependence has been estimated. Similar results were achieved at overlapping bandwidth and it has been demonstrated that the airborne non-contact ultrasound technique could be a viable alternative to the classical contact technique.

2.
Ultrasonics ; 65: 345-52, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26432190

RESUMO

In this paper the study of frequency-dependent ultrasonic attenuation in strongly heterogeneous materials is addressed. To determine the attenuation accurately over a wide frequency range, it is necessary to have suitable excitation techniques. Three kinds of transmitted signals have been analysed, grouped according to their bandwidth: narrowband and broadband signals. The mathematical formulation has revealed the relation between the distribution of energy in their spectra and their immunity to noise. Sinusoidal and burst signals have higher signal-to-noise ratios (SNRs) but need many measurements to cover their frequency range. However, linear swept-frequency signals (chirp) improve the effective bandwidth covering a wide frequency range with a single measurement and equivalent accuracy, at the expense of a lower SNR. In the case of highly attenuating materials, it is proposed to use different configurations of chirp signals, enabling injecting more energy, and therefore, improving the sensitivity of the technique without a high time cost. Thus, if the attenuation of the material and the sensitivity of the measuring equipment allows the use of broadband signals, the combination of this kind of signal and suitable signal processing results in an optimal estimate of frequency-dependent attenuation with a minimum measurement time.

3.
Ultrasonics ; 60: 88-95, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25771299

RESUMO

New applications of non-destructive techniques (NDT) with ultrasonic tests (attenuation and velocity by means of ultrasonic frequency sweeps) have been developed for the characterization of fibre-reinforced cementitious composites. According to new lines of research on glass-fibre reinforced cement (GRC) matrix modification, two similar GRC composites with high percentages of fly ash and different water/binder ratios will be studied. Conventional techniques have been used to confirm their low Ca(OH)(2) content (thermogravimetry), fibre integrity (Scanning Electron Microscopy), low porosity (Mercury Intrusion Porosimetry) and good mechanical properties (compression and four points bending test). Ultrasound frequency sweeps allowed the estimation of the attenuation and pulse velocity as functions of frequency. This ultrasonic characterization was correlated successfully with conventional techniques.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA