1.
Biomed Opt Express ; 14(12): 6233-6249, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38420319

RESUMO

Research on the spatial distribution of sensitivity of time-domain near infrared diffuse reflectance measurement is reported in this paper. The main objective of the investigation is to validate theoretically calculated sensitivity profiles for a measurement geometry with two detectors and two sources in which sensitivity profiles of statistical moments of distributions of time of flight of photons (DTOFs) are spatially restricted to a region underneath the detectors. For this dual subtraction method, smaller sensitivities to changes appearing in the superficial layer of the medium were observed compared to the single distance and single subtraction methods. Experimental validation of this approach is based on evaluation of changes in the statistical moments of DTOFs measured on a liquid phantom with local absorption perturbations. The spatial distributions of sensitivities, depth-related sensitivity and depth selectivities were obtained from the dual subtraction method and compared with those from single distance and single subtraction approaches. Also, the contrast to noise ratio (CNR) was calculated for the dual subtraction technique and combined with depth selectivity in order to assess the overall performance (product of CNR and depth selectivity) of the method. Spatial sensitivity profiles from phantom experiments are in a good agreement with the results of theoretical studies and feature more locally restricted sensitivity volume with the point of maximal sensitivity located deeper. The highest value of overall performance was obtained experimentally for the second statistical moment in the dual subtraction method (∼10.8) surpassing that of the single distance method (∼8.7). This confirms the advantage of dual subtraction measurement geometries in the suppression of optical signals originated in the superficial layer of the medium.

2.
J Biomed Opt ; 27(7)2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35701869

RESUMO

SIGNIFICANCE: Multi-laboratory initiatives are essential in performance assessment and standardization-crucial for bringing biophotonics to mature clinical use-to establish protocols and develop reference tissue phantoms that all will allow universal instrument comparison. AIM: The largest multi-laboratory comparison of performance assessment in near-infrared diffuse optics is presented, involving 28 instruments and 12 institutions on a total of eight experiments based on three consolidated protocols (BIP, MEDPHOT, and NEUROPT) as implemented on three kits of tissue phantoms. A total of 20 synthetic indicators were extracted from the dataset, some of them defined here anew. APPROACH: The exercise stems from the Innovative Training Network BitMap funded by the European Commission and expanded to include other European laboratories. A large variety of diffuse optics instruments were considered, based on different approaches (time domain/frequency domain/continuous wave), at various stages of maturity and designed for different applications (e.g., oximetry, spectroscopy, and imaging). RESULTS: This study highlights a substantial difference in hardware performances (e.g., nine decades in responsivity, four decades in dark count rate, and one decade in temporal resolution). Agreement in the estimates of homogeneous optical properties was within 12% of the median value for half of the systems, with a temporal stability of <5 % over 1 h, and day-to-day reproducibility of <3 % . Other tests encompassed linearity, crosstalk, uncertainty, and detection of optical inhomogeneities. CONCLUSIONS: This extensive multi-laboratory exercise provides a detailed assessment of near-infrared Diffuse optical instruments and can be used for reference grading. The dataset-available soon in an open data repository-can be evaluated in multiple ways, for instance, to compare different analysis tools or study the impact of hardware implementations.


Assuntos
Laboratórios , Óptica e Fotônica , Imagens de Fantasmas , Reprodutibilidade dos Testes , Análise Espectral
3.
Biomed Opt Express ; 13(11): 5753-5774, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36733725

RESUMO

Interferometric near-infrared spectroscopy (iNIRS) is an optical method that noninvasively measures the optical and dynamic properties of the human brain in vivo. However, the original iNIRS technique uses single-mode fibers for light collection, which reduces the detected light throughput. The reduced light throughput is compensated by the relatively long measurement or integration times (∼1 sec), which preclude monitoring of rapid blood flow changes that could be linked to neural activation. Here, we propose parallel interferometric near-infrared spectroscopy (πNIRS) to overcome this limitation. In πNIRS we use multi-mode fibers for light collection and a high-speed, two-dimensional camera for light detection. Each camera pixel acts effectively as a single iNIRS channel. So, the processed signals from each pixel are spatially averaged to reduce the overall integration time. Moreover, interferometric detection provides us with the unique capability of accessing complex information (amplitude and phase) about the light remitted from the sample, which with more than 8000 parallel channels, enabled us to sense the cerebral blood flow with only a 10 msec integration time (∼100x faster than conventional iNIRS). In this report, we have described the theoretical foundations and possible ways to implement πNIRS. Then, we developed a prototype continuous wave (CW) πNIRS system and validated it in liquid phantoms. We used our CW πNIRS to monitor the pulsatile blood flow in a human forearm in vivo. Finally, we demonstrated that CW πNIRS could monitor activation of the prefrontal cortex by recording the change in blood flow in the forehead of the subject while he was reading an unknown text.

4.
Biomed Opt Express ; 12(10): 6629-6650, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34745761

RESUMO

We present and validate a multi-wavelength time-domain near-infrared spectroscopy (TD-NIRS) system that avoids switching wavelengths and instead exploits the full capability of a supercontinuum light source by emitting and acquiring signals for the whole chosen range of wavelengths. The system was designed for muscle and brain oxygenation monitoring in a clinical environment. A pulsed supercontinuum laser emits broadband light and each of two detection modules acquires the distributions of times of flight of photons (DTOFs) for 16 spectral channels (used width 12.5 nm / channel), providing a total of 32 DTOFs at up to 3 Hz. Two emitting fibers and two detection fiber bundles allow simultaneous measurements at two positions on the tissue or at two source-detector separations. Three established protocols (BIP, MEDPHOT, and nEUROPt) were used to quantitatively assess the system's performance, including linearity, coupling, accuracy, and depth sensitivity. Measurements were performed on 32 homogeneous phantoms and two inhomogeneous phantoms (solid and liquid). Furthermore, measurements on two blood-lipid phantoms with a varied amount of blood and Intralipid provide the strongest validation for accurate tissue oximetry. The retrieved hemoglobin concentrations and oxygen saturation match well with the reference values that were obtained using a commercially available NIRS system (OxiplexTS) and a blood gas analyzer (ABL90 FLEX), except a discrepancy occurs for the lowest amount of Intralipid. In-vivo measurements on the forearm of three healthy volunteers during arterial (250 mmHg) and venous (60 mmHg) cuff occlusions provide an example of tissue monitoring during the expected hemodynamic changes that follow previously well-described physiologies. All results, including quantitative parameters, can be compared to other systems that report similar tests. Overall, the presented TD-NIRS system has an exemplary performance evaluated with state-of-the-art performance assessment methods.

5.
Biomed Opt Express ; 11(2): 1043-1060, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32133236

RESUMO

A methodology for the assessment of the cerebral hemodynamic reaction to normotensive hypovolemia, reduction in cerebral perfusion and orthostatic stress leading to ischemic hypoxia and reduced muscular tension is presented. Most frequently, the pilots of highly maneuverable aircraft are exposed to these phenomena. Studies were carried out using the system consisting of a chamber that generates low pressure around the lower part of the body - LBNP (lower body negative pressure) placed on the tilt table. An in-house developed 6-channel NIRS system operating at 735 and 850 nm was used in order to assess the oxygenation of the cerebral cortex, based on measurements of diffusely reflected light in reflectance geometry. The measurements were carried out on a group of 12 active pilots and cadets of the Polish Air Force Academy and 12 healthy volunteers. The dynamics of changes in cerebral oxygenation was evaluated as a response to LBNP stimuli with a simultaneous rapid change of the tilt table angle. Parameters based on calculated changes of total hemoglobin concentration were proposed allowing to evaluate differences in reactions observed in control subjects and pilots/cadets. The results of orthogonal partial least squares-discriminant analysis based on these parameters show that the subjects can be classified into their groups with 100% accuracy.

6.
Biomed Opt Express ; 10(9): 4621-4635, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31565513

RESUMO

Time-resolved near-infrared spectroscopy (TR-NIRS) measurements can be used to recover changes in concentrations of tissue constituents ( Δ C ) by applying the moments method and the Beer-Lambert law. In this work we carried out the error propagation analysis allowing to calculate the standard deviations of uncertainty in estimation of the Δ C . Here, we show the process of choosing wavelengths for the evaluation of hemodynamic (oxy-, deoxyhemoglobin) and metabolic (cytochrome-c-oxidase (CCO)) responses within the brain tissue as measured with an in-house developed TR-NIRS multi-wavelength system, which measures at 16 consecutive wavelengths separated by 12.5 nm and placed between 650 and 950 nm. Data generated with Monte Carlo simulations on three-layered model (scalp, skull, brain) for wavelengths range from 650 to 950 nm were used to carry out the error propagation analysis for varying choices of wavelengths. For a detector with a spectrally uniform responsivity, the minimal standard deviation of the estimated changes in CCO within the brain layer, σ Δ C CCO brain = 0.40 µM, was observed for the 16 consecutive wavelengths from 725 to 912.5 nm. For realistic a detector model, i.e. the spectral responsivity characteristic is considered, the minimum, σ Δ C CCO brain = 0.47 µM, was observed at the 16 consecutive wavelengths from 688 to 875 nm. We introduce the method of applying the error propagation analysis to data as measured with spectral TR-NIRS systems to calculate uncertainty of recovery of tissue constituents concentrations.

7.
Biomed Opt Express ; 10(5): 2657-2669, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31149386

RESUMO

Time-resolved near infrared spectroscopy is considered to be a gold standard technique when measuring absolute values of tissue optical properties, as it provides separable and independent information about both tissue absorption and scattering. However, time-resolved instruments require an accurate characterization by measuring the instrument response function in order to decouple the contribution of the instrument itself from the measurement. In this work, a new approach to the methodology of analysing time-resolved data is presented where the influence of instrument response function is eliminated from the data and a self-calibrating analysis is proposed. The proposed methodology requires an instrument to provide at least two wavelengths and allows spectral parameters recovery (optical properties or constituents concentrations and reduced scatter amplitude and power). Phantom and in-vivo data from two different time-resolved systems are used to validate the accuracy of the proposed self-calibrating approach, demonstrating that parameters recovery compared to the conventional curve fitting approach is within 10% and benefits from introducing a spectral constraint to the reconstruction problem. It is shown that a multi-wavelength time-resolved data can be used for parameters recovery directly without prior calibration (instrument response function measurement).

8.
Biomed Opt Express ; 10(2): 761-771, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30800513

RESUMO

In this paper, we propose the application of time-domain near-infrared spectroscopy to the assessment of oscillations in cerebral hemodynamics. These oscillations were observed in the statistical moments of the distributions of time of flight of photons (DTOFs) measured on the head. We analyzed the zeroth and second centralized moments of DTOFs (total number of photons and variance) to obtain their spectra to provide parameters for the frequency components of microcirculation, which differ between the extracerebral and intracerebral layers of the head. Analysis of these moments revealed statistically significant differences between a control group of healthy subjects and a group of patients with severe neurovascular disorders, which is a promising result for the assessment of cerebral microcirculation and cerebral autoregulation mechanisms.

9.
J Chem Phys ; 149(10): 104301, 2018 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-30218999

RESUMO

UV-induced transformations were studied for monomers of 6-azacytosine isolated in low-temperature Ar matrices. In contrast to cytosine, where the amino-hydroxy (AH) tautomer is the lowest-energy form, the amino-oxo (AO) and imino-oxo (IO) isomers of 6-azacytosine were found to be the most stable and most populated. Due to the high relative energy of the AH tautomer of 6-azacytosine, this form is not populated in low-temperature matrices after their formation and prior to any irradiation. Excitation of 6-azacytosine monomers with UV light from the 328-300 nm range led to structural transformations of AO and IO forms. The initially most populated AO tautomer was observed either to convert, in a phototautomeric reaction, into the AH product or to undergo photodecarbonylation to yield 4-amino-1,2,3-(2H)-triazole. The relative efficiencies of the two processes depend on the wavelength and on the pulsed or continuous-wave character of the UV light used for excitation. For the IO tautomer of 6-azacytosine, the excitation with UV 328-300 nm light induced the photoconversion of the initially more populated anti IO1 isomer into the syn IO2 form. This transformation was found to be partially photoreversible.

10.
Biomed Opt Express ; 9(7): 2974-2993, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29984079

RESUMO

An optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for the clinical assessment of brain perfusion at the bedside. We report on multiwavelength time-resolved diffuse reflectance spectroscopy measurements carried out on the head of a healthy adult during the intravenous administration of a bolus of ICG. Intracerebral and extracerebral changes in absorption were estimated from an analysis of changes in statistical moments (total number of photons, mean time of flight and variance) of the distributions of times of flight (DTOF) of photons recorded simultaneously at 16 wavelengths from the range of 650-850 nm using sensitivity factors estimated by diffusion approximation based on a layered model of the studied medium. We validated the proposed method in a series of phantom experiments and in-vivo measurements. The results obtained show that changes in the concentration of the ICG can be assessed as a function of time of the experiment and depth in the tissue. Thus, the separation of changes in ICG concentration appearing in intra- and extracerebral tissues can be estimated from optical data acquired at a single source-detector pair of fibers/fiber bundles positioned on the surface of the head.

11.
Sci Rep ; 8(1): 7332, 2018 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-29743483

RESUMO

We aimed to determine whether optical methods based on bolus tracking of an optical contrast agent are useful for the confirmation of cerebral circulation cessation in patients being evaluated for brain death. Different stages of cerebral perfusion disturbance were compared in three groups of subjects: controls, patients with posttraumatic cerebral edema, and patients with brain death. We used a time-resolved near-infrared spectroscopy setup and indocyanine green (ICG) as an intravascular flow tracer. Orthogonal partial least squares-discriminant analysis (OPLS-DA) was carried out to build statistical models allowing for group separation. Thirty of 37 subjects (81.1%) were classified correctly (8 of 9 control subjects, 88.9%; 13 of 15 patients with edema, 86.7%; and 9 of 13 patients with brain death, 69.2%; p < 0.0001). Depending on the combination of variables used in the OPLS-DA model, sensitivity, specificity, and accuracy were 66.7-92.9%, 81.8-92.9%, and 77.3-89.3%, respectively. The method was feasible and promising in the demanding intensive care unit environment. However, its accuracy did not reach the level required for brain death confirmation. The potential usefulness of the method may be improved by increasing the depth of light penetration, confirming its accuracy against other methods evaluating cerebral flow cessation, and developing absolute parameters for cerebral perfusion.


Assuntos
Morte Encefálica/diagnóstico por imagem , Morte Encefálica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo , Edema Encefálico/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Meios de Contraste/farmacologia , Análise Discriminante , Estudos de Viabilidade , Feminino , Humanos , Verde de Indocianina , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Perfusão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos
12.
J Cereb Blood Flow Metab ; 36(11): 1825-1843, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27604312

RESUMO

We present an overview of the wide range of potential applications of optical methods for monitoring traumatic brain injury. The MEDLINE database was electronically searched with the following search terms: "traumatic brain injury," "head injury," or "head trauma," and "optical methods," "NIRS," "near-infrared spectroscopy," "cerebral oxygenation," or "cerebral oximetry." Original reports concerning human subjects published from January 1980 to June 2015 in English were analyzed. Fifty-four studies met our inclusion criteria. Optical methods have been tested for detection of intracranial lesions, monitoring brain oxygenation, assessment of brain perfusion, and evaluation of cerebral autoregulation or intracellular metabolic processes in the brain. Some studies have also examined the applicability of optical methods during the recovery phase of traumatic brain injury . The limitations of currently available optical methods and promising directions of future development are described in this review. Considering the outstanding technical challenges, the limited number of patients studied, and the mixed results and opinions gathered from other reviews on this subject, we believe that optical methods must remain primarily research tools for the present. More studies are needed to gain confidence in the use of these techniques for neuromonitoring of traumatic brain injury patients.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Hemorragia Intracraniana Traumática/diagnóstico por imagem , Neuroimagem/métodos , Imagem Óptica/métodos , Lesões Encefálicas Traumáticas/metabolismo , Lesões Encefálicas Traumáticas/patologia , Lesões Encefálicas Traumáticas/fisiopatologia , Humanos , Hemorragia Intracraniana Traumática/metabolismo , Hemorragia Intracraniana Traumática/patologia , Oximetria/métodos , Consumo de Oxigênio/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos
13.
J Biomed Opt ; 20(10): 106013, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26509415

RESUMO

The aim of the study was to determine optimal measurement conditions for assessment of brain perfusion with the use of optical contrast agent and time-resolved diffuse reflectometry in the near-infrared wavelength range. The source-detector separation at which the distribution of time of flights (DTOF) of photons provided useful information on the inflow of the contrast agent to the intracerebral brain tissue compartments was determined. Series of Monte Carlo simulations was performed in which the inflow and washout of the dye in extra- and intracerebral tissue compartments was modeled and the DTOFs were obtained at different source-detector separations. Furthermore, tests on diffuse phantoms were carried out using a time-resolved setup allowing the measurement of DTOFs at 16 source-detector separations. Finally, the setup was applied in experiments carried out on the heads of adult volunteers during intravenous injection of indocyanine green. Analysis of statistical moments of the measured DTOFs showed that the source-detector separation of 6 cm is recommended for monitoring of inflow of optical contrast to the intracerebral brain tissue compartments with the use of continuous wave reflectometry, whereas the separation of 4 cm is enough when the higher-order moments of DTOFs are available.


Assuntos
Meios de Contraste/farmacocinética , Aumento da Imagem/métodos , Imagem de Perfusão/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Encéfalo , Circulação Cerebrovascular , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Biomed Opt Express ; 5(3): 800-16, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24688815

RESUMO

The aim of this study was to examine neurotoxicity indocyanine green (ICG). We assessed viability of primary cerebellar granule cell culture (CGC) exposed to ICG to test two mechanisms that could be the first triggers causing neuronal toxicity: imbalance in calcium homeostasis and the degree of oligomerization of ICG molecules. We have observed this imbalance in CGC after exposure to 75-125µΜ ICG and dose and application sequence dependent protective effect of Gadovist on surviving neurons in vitro when used with ICG. Spectroscopic studies suggest the major cause of toxicity of the ICG is connected with oligomers formation. ICG at concentration of 25 µM (which is about 4 times higher than the highest concentration of ICG in the brain applied in in-vivo human studies) is not neurotoxic in the cell culture.

15.
Phys Med Biol ; 59(6): 1407-24, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24584056

RESUMO

It was recently reported that the time-resolved measurement of diffuse reflectance and/or fluorescence during injection of an optical contrast agent may constitute a basis for a technique to assess cerebral perfusion. In this paper, we present results of Monte Carlo simulations of the propagation of excitation photons and tracking of fluorescence photons in a two-layered tissue model mimicking intra- and extracerebral tissue compartments. Spatial 3D distributions of the probability that the photons were converted from excitation to emission wavelength in a defined voxel of the medium (generation probability) during their travel between source and detector were obtained for different optical properties in intra- and extracerebral tissue compartments. It was noted that the spatial distribution of the generation probability depends on the distribution of the fluorophore in the medium and is influenced by the absorption of the medium and of the fluorophore at excitation and emission wavelengths. Simulations were also carried out for realistic time courses of the dye concentration in both layers. The results of the study show that the knowledge of the absorption properties of the medium at excitation and emission wavelengths is essential for the interpretation of the time-resolved fluorescence signals measured on the surface of the head.


Assuntos
Biomimética , Fluorescência , Método de Monte Carlo , Absorção , Encéfalo/citologia , Encéfalo/metabolismo , Verde de Indocianina/metabolismo , Fótons , Probabilidade , Espectroscopia de Luz Próxima ao Infravermelho , Fatores de Tempo
16.
Artigo em Inglês | MEDLINE | ID: mdl-24110368

RESUMO

We report on a fluorescence-based optical method for assessment of blood-brain barrier in humans. The technique is based on monitoring of fluorescence light excited in the dye circulating in the brain. Measurements were carried out in healthy volunteers and in patients with disruption of the blood-brain barrier with the use of time-resolved method during inflow and washout of indocyanine green after its intravenous injection. We show large differences in the fluorescence signals - in healthy subjects a fast washout of the dye can be observed whereas in patients the washout is significantly prolonged. We conclude that the monitoring of the fluorescence signals during injection of exogenous optical contrast agent can be used for the assessment of the condition of blood-brain barrier at the bedside. The technique may be of benefit for diagnosis of the patients suffering from damage of the blood-brain barrier and in monitoring of therapies used in such patients.


Assuntos
Barreira Hematoencefálica , Corantes Fluorescentes/administração & dosagem , Microscopia de Fluorescência/instrumentação , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/efeitos dos fármacos , Encefalopatias/fisiopatologia , Meios de Contraste , Eletrodos , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Voluntários Saudáveis , Humanos , Verde de Indocianina , Injeções Intravenosas , Microscopia de Fluorescência/métodos , Fibras Ópticas , Posicionamento do Paciente , Coloração e Rotulagem
17.
Biomed Opt Express ; 4(2): 206-18, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23413183

RESUMO

Variance of time-of-flight distributions have been shown to be more sensitive to cerebral blood flow (CBF) during dynamic-contrast enhanced monitoring of neurotrauma patients than attenuation. What is unknown is the degree to which variance is affected by changes in extracerebral blood flow. Furthermore, the importance of acquiring the arterial input function (AIF) on quantitative analysis of the data is not yet clear. This animal study confirms that variance is both sensitive and specific to changes occurring in the brain when measurements are acquired on the surface of the scalp. Furthermore, when the variance data along with the measured AIF is analyzed using a nonparametric deconvolution method, the recovered change in CBF is in good agreement with CT perfusion values.

18.
J Biomed Opt ; 17(8): 087001, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23224200

RESUMO

Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is presented and advantages of measurements at multiple wavelengths are discussed. Measurements were carried out: 1. on a physical homogeneous phantom to study the concentration dependence of the fluorescence signal, 2. on the phantom to simulate the dynamic inflow of ICG at different depths, and 3. in vivo on surface of the human head. Pattern of inflow and washout of ICG in the head of healthy volunteers after intravenous injection of the dye was observed for the first time with time-resolved instrumentation at multiple emission wavelengths. The multiwavelength detection of fluorescence signal confirms that at longer emission wavelengths, probability of reabsorption of the fluorescence light by the dye itself is reduced. Considering different light penetration depths at different wavelengths, and the pronounced reabsorption at longer wavelengths, the time-resolved multiwavelength technique may be useful in signal decomposition, leading to evaluation of extra- and intracerebral components of the measured signals.


Assuntos
Encéfalo/citologia , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Verde de Indocianina/farmacocinética , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Imagem de Perfusão/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste/farmacocinética , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Phys Med Biol ; 57(20): 6725-42, 2012 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-23032301

RESUMO

It was reported that time-resolved reflectance measurements carried out during inflow and washout of an optical contrast agent may provide information on the blood supply to the brain cortex of human adults. It was also shown that a measurement of fluorescence excited in the dye circulating in the brain is feasible. Unfortunately, patterns of time-resolved fluorescence signals observed during in vivo measurements are difficult to interpret. The aim of this study was to analyze the influence of several factors on the fluorescence signals measured during in vivo experiments. A laboratory instrument for recording the distributions of arrival of fluorescence photons was constructed and optimized for measurements on humans. Monte Carlo simulations and laboratory measurements on liquid phantoms as well as in vivo measurements on healthy volunteers were carried out. An influence of source-detector separation, position of the source-detector pair on the head, as well as a dose of the injected indocyanine green (ICG) on the fluorescence signals were studied in detail. It was shown that even for a small dose of ICG (0.025 mg kg(-1)) the time-resolved signals can be successfully detected on the surface of the head. Strong influence of the studied factors on the fluorescence signals was observed. It was also noted that the changes in moments of distributions of arrival times of fluorescence photons depend on the anatomical structure of the tissues located between the source and the detector.


Assuntos
Encéfalo/metabolismo , Meios de Contraste/metabolismo , Fluorescência , Verde de Indocianina/metabolismo , Transporte Biológico , Humanos , Injeções , Método de Monte Carlo , Imagens de Fantasmas , Fatores de Tempo
20.
Anaesthesiol Intensive Ther ; 44(4): 226-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23348492

RESUMO

Despite the fact that several modes of ventilation are being used, it is not always possible to maintain adequate parameters of gas exchange. In order to provide proper ventilation, it is necessary to assess the lung function. The aim of this article is presentation of different methods of assesment of lung aerations including its advantages, disadvantages and possibilities for implementation in clinical practice. Computed tomography provides information regarding morphology and aeration of lung tissue, but has several limitations: necessity of patients transportation, it cannot be performed in a continuous manner, a quantitative assessment of picture seems to be rather complicated. Ultrasonography is widely used in intensive care and is a noninvasive and bedside method. It gives the opportunity to assess an investigated organ in real time. Its clinical utility in patients with ARDS was proved by Lichtenstein et al. Another technology which has been implemented for the purpose of lungs visualization is electrobioimpedancy (EIT). This new method consists of continuous monitoring of chest electrobioimpedancy changes due to its air content. Unlike to techniques mentioned above, lung images generated with EIT do not provide any information about morphology of affected tissue. The method which indirectly describes the sum of lung interactions is the assessment of quasi-static P/V curve. This method provides information allowing to draw conclusions regarding the usefulness of recruitment maneuvers, but does not provide information regarding the nature of morphologic changes and their location. In the search for the ideal method of lung aeration assessment, it is necessary to define its characteristics, such as noninvasiveness, availability and visualization of tissue morphologic changes in real time.


Assuntos
Pulmão/fisiologia , Respiração Artificial , Impedância Elétrica , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA