Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Comput Methods Programs Biomed ; 254: 108254, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38905989

RESUMO

BACKGROUND AND OBJECTIVES: Episodes of Freezing of Gait (FoG) are among the most debilitating motor symptoms of Parkinson's Disease (PD), leading to falls and significantly impacting patients' quality of life. Accurate assessment of FoG by neurologists provides crucial insights into patients' conditions and disease symptoms. This proposed strategy involves utilizing a Weighted Fuzzy Logic Controller, Kalman Filter, and Kaiser-Meyer-Olkin test to detect the gait parameters while walking, resting, and standing phases. Parameters such as neuromodulation format, intensity, duration, frequency, and velocity are computed to pre-empt freezing episodes, thus aiding their prevention. METHOD: The AiCarePWP is a wearable electronics device designed to identify instances when a patient is on the brink of experiencing a freezing episode and subsequently deliver a brief electrical impulse to the patient's shank muscles to stimulate movement. The AiCarePWP wearable device aims to identify impending freezing episodes in PD patients and deliver brief electrical impulses to stimulate movement. The study validates this innovative approach using plantar insoles with a 3D accelerometer and electrical stimulator, analysing data from the inertial measuring unit and plantar-pressure foot data to detect and predict FoG. RESULTS: Using a Convolutional Neural Network-based model, the study evaluated 47 gait features for their ability to differentiate resting, standing, and walking conditions. Variable selection was based on sensitivity, specificity, and overall accuracy, followed by Principal Component Analysis and Varimax rotation to extract and interpret factors. Factors with eigenvalues exceeding 1.0 were retained, and 37 features were retained. CONCLUSION: This study validates CNN's effectiveness in detecting FoG during various activities. It introduces a novel cueing method using electrical stimulation, which improves gait function and reduces FoG incidence in PD patients. Trustworthy wearable devices, based on Artificial Intelligence of Things (AIoT) and Artificial Intelligence of Medical Things (AIoMT), have been developed to support such interventions.

2.
Front Neurol ; 14: 1272992, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38145118

RESUMO

Background: Stroke is one of the most common neurological conditions that often leads to upper limb motor impairments, significantly affecting individuals' quality of life. Rehabilitation strategies are crucial in facilitating post-stroke recovery and improving functional independence. Functional Electrical Stimulation (FES) systems have emerged as promising upper limb rehabilitation tools, offering innovative neuromuscular reeducation approaches. Objective: The main objective of this paper is to provide a comprehensive systematic review of the start-of-the-art functional electrical stimulation (FES) systems for upper limb neurorehabilitation in post-stroke therapy. More specifically, this paper aims to review different types of FES systems, their feasibility testing, or randomized control trials (RCT) studies. Methods: The FES systems classification is based on the involvement of patient feedback within the FES control, which mainly includes "Open-Loop FES Systems" (manually controlled) and "Closed-Loop FES Systems" (brain-computer interface-BCI and electromyography-EMG controlled). Thus, valuable insights are presented into the technological advantages and effectiveness of Manual FES, EEG-FES, and EMG-FES systems. Results and discussion: The review analyzed 25 studies and found that the use of FES-based rehabilitation systems resulted in favorable outcomes for the stroke recovery of upper limb functional movements, as measured by the FMA (Fugl-Meyer Assessment) (Manually controlled FES: mean difference = 5.6, 95% CI (3.77, 7.5), P < 0.001; BCI-controlled FES: mean difference = 5.37, 95% CI (4.2, 6.6), P < 0.001; EMG-controlled FES: mean difference = 14.14, 95% CI (11.72, 16.6), P < 0.001) and ARAT (Action Research Arm Test) (EMG-controlled FES: mean difference = 11.9, 95% CI (8.8, 14.9), P < 0.001) scores. Furthermore, the shortcomings, clinical considerations, comparison to non-FES systems, design improvements, and possible future implications are also discussed for improving stroke rehabilitation systems and advancing post-stroke recovery. Thus, summarizing the existing literature, this review paper can help researchers identify areas for further investigation. This can lead to formulating research questions and developing new studies aimed at improving FES systems and their outcomes in upper limb rehabilitation.

3.
Neural Comput Appl ; 35(20): 14591-14609, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35250181

RESUMO

A SARS-CoV-2 virus-specific reverse transcriptase-polymerase chain reaction (RT-PCR) test is usually used to diagnose COVID-19. However, this test requires up to 2 days for completion. Moreover, to avoid false-negative outcomes, serial testing may be essential. The availability of RT-PCR test kits is currently limited, highlighting the need for alternative approaches for the precise and rapid diagnosis of COVID-19. Patients suspected to be infected with SARS-CoV-2 can be assessed using chest CT scan images. However, CT images alone cannot be used for ruling out SARS-CoV-2 infection because individual patients may exhibit normal radiological results in the primary phases of the disease. A machine learning (ML)-based recognition and segmentation system was developed to spontaneously discover and compute infection areas in CT scans of COVID-19 patients. The computable assessment exhibited suitable performance for automatic infection region allocation. The ML models developed were suitable for the direct detection of COVID-19 (+). ML was confirmed to be a complementary diagnostic technique for diagnosing COVID-19(+) by forefront medical specialists. The complete manual delineation of COVID-19 often requires up to 225.5 min; however, the proposed RILML method decreases the delineation time to 7 min after four iterations of model updating.

4.
Sensors (Basel) ; 22(5)2022 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35270929

RESUMO

The object recognition concept is being widely used a result of increasing CCTV surveillance and the need for automatic object or activity detection from images or video. Increases in the use of various sensor networks have also raised the need of lightweight process frameworks. Much research has been carried out in this area, but the research scope is colossal as it deals with open-ended problems such as being able to achieve high accuracy in little time using lightweight process frameworks. Convolution Neural Networks and their variants are widely used in various computer vision activities, but most of the architectures of CNN are application-specific. There is always a need for generic architectures with better performance. This paper introduces the Dimension-Based Generic Convolution Block (DBGC), which can be used with any CNN to make the architecture generic and provide a dimension-wise selection of various height, width, and depth kernels. This single unit which uses the separable convolution concept provides multiple combinations using various dimension-based kernels. This single unit can be used for height-based, width-based, or depth-based dimensions; the same unit can even be used for height and width, width and depth, and depth and height dimensions. It can also be used for combinations involving all three dimensions of height, width, and depth. The main novelty of DBGC lies in the dimension selector block included in the proposed architecture. Proposed unoptimized kernel dimensions reduce FLOPs by around one third and also reduce the accuracy by around one half; semi-optimized kernel dimensions yield almost the same or higher accuracy with half the FLOPs of the original architecture, while optimized kernel dimensions provide 5 to 6% higher accuracy with around a 10 M reduction in FLOPs.


Assuntos
Computadores , Redes Neurais de Computação
5.
IEEE J Biomed Health Inform ; 26(5): 1937-1948, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34260362

RESUMO

Healthcare big data (HBD) allows medical stakeholders to analyze, access, retrieve personal and electronic health records (EHR) of patients. Mostly, the records are stored on healthcare cloud and application (HCA) servers, and thus, are subjected to end-user latency, extensive computations, single-point failures, and security and privacy risks. A joint solution is required to address the issues of responsive analytics, coupled with high data ingestion in HBD and secure EHR access. Motivated from the research gaps, the paper proposes a scheme, that integrates blockchain (BC)-based confidentiality-privacy (CP) preserving scheme, CP-BDHCA, that operates in two phases. In the first phase, elliptic curve cryptographic (ECC)-based digital signature framework, HCA-ECC is proposed to establish a session key for secure communication among different healthcare entities. Then, in the second phase, a two-step authentication framework is proposed that integrates Rivest-Shamir-Adleman (RSA) and advanced encryption standard (AES), named as HCA-RSAE that safeguards the ecosystem against possible attack vectors. CP-BDAHCA is compared against existing HCA cloud applications in terms of parameters like response time, average delay, transaction and signing costs, signing and verifying of mined blocks, and resistance to DoS and DDoS attacks. We consider 10 BC nodes and create a real-world customized dataset to be used with SEER dataset. The dataset has 30,000 patient profiles, with 1000 clinical accounts. Based on the combined dataset the proposed scheme outperforms traditional schemes like AI4SAFE, TEE, Secret, and IIoTEED, with a lower response time. For example, the scheme has a very less response time of 300 ms in DDoS. The average signing cost of mined BC transactions is 3,34 seconds, and for 205 transactions, has a signing delay of 1405 ms, with improved accuracy of ≈ 12% than conventional state-of-the-art approaches.


Assuntos
Blockchain , Big Data , Segurança Computacional , Confidencialidade , Atenção à Saúde , Ecossistema , Registros Eletrônicos de Saúde , Humanos , Privacidade
6.
Sustain Cities Soc ; 69: 102798, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36568858

RESUMO

Human movement is a significant factor in extensive spatial-transmission models of contagious viruses. The proposed COUNTERACT system recognizes infectious sites by retrieving location data from a mobile phone device linked with a particular infected subject. The proposed approach is computing an incubation phase for the subject's infection, backpropagation through the subjects' location data to investigate a location where the subject has been during the incubation period. Classifying to each such site as a contagious site, informing exposed suspects who have been to the contagious location, and seeking near real-time or real-time feedback from suspects to affirm, discard, or improve the recognition of the infectious site. This technique is based on the contraption to gather confirmed infected subject and possibly carrier suspect area location, correlating location for the incubation days. Security and privacy are a specific thing in the present research, and the system is used only through authentication and authorization. The proposed approach is for healthcare officials primarily. It is different from other existing systems where all the subjects have to install the application. The cell phone associated with the global positioning system (GPS) location data is collected from the COVID-19 subjects.

7.
Sensors (Basel) ; 20(24)2020 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-33353248

RESUMO

Human Action Recognition (HAR) is the classification of an action performed by a human. The goal of this study was to recognize human actions in action video sequences. We present a novel feature descriptor for HAR that involves multiple features and combining them using fusion technique. The major focus of the feature descriptor is to exploits the action dissimilarities. The key contribution of the proposed approach is to built robust features descriptor that can work for underlying video sequences and various classification models. To achieve the objective of the proposed work, HAR has been performed in the following manner. First, moving object detection and segmentation are performed from the background. The features are calculated using the histogram of oriented gradient (HOG) from a segmented moving object. To reduce the feature descriptor size, we take an averaging of the HOG features across non-overlapping video frames. For the frequency domain information we have calculated regional features from the Fourier hog. Moreover, we have also included the velocity and displacement of moving object. Finally, we use fusion technique to combine these features in the proposed work. After a feature descriptor is prepared, it is provided to the classifier. Here, we have used well-known classifiers such as artificial neural networks (ANNs), support vector machine (SVM), multiple kernel learning (MKL), Meta-cognitive Neural Network (McNN), and the late fusion methods. The main objective of the proposed approach is to prepare a robust feature descriptor and to show the diversity of our feature descriptor. Though we are using five different classifiers, our feature descriptor performs relatively well across the various classifiers. The proposed approach is performed and compared with the state-of-the-art methods for action recognition on two publicly available benchmark datasets (KTH and Weizmann) and for cross-validation on the UCF11 dataset, HMDB51 dataset, and UCF101 dataset. Results of the control experiments, such as a change in the SVM classifier and the effects of the second hidden layer in ANN, are also reported. The results demonstrate that the proposed method performs reasonably compared with the majority of existing state-of-the-art methods, including the convolutional neural network-based feature extractors.


Assuntos
Redes Neurais de Computação , Reconhecimento Automatizado de Padrão , Atividades Humanas , Humanos , Máquina de Vetores de Suporte
8.
Sensors (Basel) ; 20(20)2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33053886

RESUMO

Oral mucosal lesions (OML) and oral potentially malignant disorders (OPMDs) have been identified as having the potential to transform into oral squamous cell carcinoma (OSCC). This research focuses on the human-in-the-loop-system named Healthcare Professionals in the Loop (HPIL) to support diagnosis through an advanced machine learning procedure. HPIL is a novel system approach based on the textural pattern of OML and OPMDs (anomalous regions) to differentiate them from standard regions of the oral cavity by using autofluorescence imaging. An innovative method based on pre-processing, e.g., the Deriche-Canny edge detector and circular Hough transform (CHT); a post-processing textural analysis approach using the gray-level co-occurrence matrix (GLCM); and a feature selection algorithm (linear discriminant analysis (LDA)), followed by k-nearest neighbor (KNN) to classify OPMDs and the standard region, is proposed in this paper. The accuracy, sensitivity, and specificity in differentiating between standard and anomalous regions of the oral cavity are 83%, 85%, and 84%, respectively. The performance evaluation was plotted through the receiver operating characteristics of periodontist diagnosis with the HPIL system and without the system. This method of classifying OML and OPMD areas may help the dental specialist to identify anomalous regions for performing their biopsies more efficiently to predict the histological diagnosis of epithelial dysplasia.


Assuntos
Carcinoma de Células Escamosas , Neoplasias Bucais , Imagem Óptica , Carcinoma de Células Escamosas/diagnóstico por imagem , Atenção à Saúde , Humanos , Neoplasias Bucais/diagnóstico por imagem , Padrões de Referência
9.
Sensors (Basel) ; 20(18)2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32972037

RESUMO

Air pollution has been a looming issue of the 21st century that has also significantly impacted the surrounding environment and societal health. Recently, previous studies have conducted extensive research on air pollution and air quality monitoring. Despite this, the fields of air pollution and air quality monitoring remain plagued with unsolved problems. In this study, the Pollution Weather Prediction System (PWP) is proposed to perform air pollution prediction for outdoor sites for various pollution parameters. In the presented research work, we introduced a PWP system configured with pollution-sensing units, such as SDS021, MQ07-CO, NO2-B43F, and Aeroqual Ozone (O3). These sensing units were utilized to collect and measure various pollutant levels, such as PM2.5, PM10, CO, NO2, and O3, for 90 days at Symbiosis International University, Pune, Maharashtra, India. The data collection was carried out between the duration of December 2019 to February 2020 during the winter. The investigation results validate the success of the presented PWP system. In the conducted experiments, linear regression and artificial neural network (ANN)-based AQI (air quality index) predictions were performed. Furthermore, the presented study also found that the customized linear regression methodology outperformed other machine-learning methods, such as linear, ridge, Lasso, Bayes, Huber, Lars, Lasso-lars, stochastic gradient descent (SGD), and ElasticNet regression methodologies, and the customized ANN regression methodology used in the conducted experiments. The overall AQI values of the air pollutants were calculated based on the summation of the AQI values of all the presented air pollutants. In the end, the web and mobile interfaces were developed to display air pollution prediction values of a variety of air pollutants.


Assuntos
Poluição do Ar , Monitoramento Ambiental , Tempo (Meteorologia) , Poluição do Ar/análise , Teorema de Bayes , Humanos , Índia , Material Particulado/análise
10.
Sensors (Basel) ; 19(4)2019 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-30781852

RESUMO

BACKGROUND: Ambiguities and anomalies in the Activity of Daily Living (ADL) patterns indicate deviations from Wellness. The monitoring of lifestyles could facilitate remote physicians or caregivers to give insight into symptoms of the disease and provide health improvement advice to residents; Objective: This research work aims to apply lifestyle monitoring in an ambient assisted living (AAL) system by diagnosing conduct and distinguishing variation from the norm with the slightest conceivable fake alert. In pursuing this aim, the main objective is to fill the knowledge gap of two contextual observations (i.e., day and time) in the frequent behavior modeling for an individual in AAL. Each sensing category has its advantages and restrictions. Only a single type of sensing unit may not manage composite states in practice and lose the activity of daily living. To boost the efficiency of the system, we offer an exceptional sensor data fusion technique through different sensing modalities; Methods: As behaviors may also change according to other contextual observations, including seasonal, weather (or temperature), and social interaction, we propose the design of a novel activity learning model by adding behavioral observations, which we name as the Wellness indices analysis model; Results: The ground-truth data are collected from four elderly houses, including daily activities, with a sample size of three hundred days plus sensor activation. The investigation results validate the success of our method. The new feature set from sensor data fusion enhances the system accuracy to (98.17% ± 0.95) from (80.81% ± 0.68). The performance evaluation parameters of the proposed model for ADL recognition are recorded for the 14 selected activities. These parameters are Sensitivity (0.9852), Specificity (0.9988), Accuracy (0.9974), F1 score (0.9851), False Negative Rate (0.0130).


Assuntos
Atividades Cotidianas , Moradias Assistidas/tendências , Técnicas Biossensoriais/métodos , Idoso , Cuidadores , Humanos
11.
IEEE J Transl Eng Health Med ; 6: 1900312, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30042903

RESUMO

Heart sounds deliver vital physiological and pathological evidence about health. Wireless cardiac auscultation offers continuous cardiac monitoring of an individual without 24*7 manual healthcare care services. In this paper, a novel wireless sensing system to monitor and analyze cardiac condition is proposed, which sends the information to the caregiver as well as a medical practitioner with an application of the Internet of Things (IoT). An integrated system for heart sound acquisition, storage, and asynchronous analysis has been developed, from scratch to information uploading through IoT and signal analysis. Cardiac auscultation sensing unit has been designed to monitor cardiovascular health of an individual. Bluetooth protocol is used to offer power efficiency and moderate data transmission rate. The Hilbert-Huang transform is used to eliminate interference signals and to help to extract the heart sound signal features. Subsequence segmentation algorithm based on double-threshold has been developed to extract physiological parameters. Preprocessing, segmentation, and clustering technique were performed for significant health information interpretation. The cardiac auscultation monitoring system may provide a way for heart disease self-management.

13.
Sensors (Basel) ; 17(1)2016 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-28042831

RESUMO

Wireless sensor networks (WSNs) provide noteworthy benefits over traditional approaches for several applications, including smart homes, healthcare, environmental monitoring, and homeland security. WSNs are integrated with the Internet Protocol (IP) to develop the Internet of Things (IoT) for connecting everyday life objects to the internet. Hence, major challenges of WSNs include: (i) how to efficiently utilize small size and low-power nodes to implement security during data transmission among several sensor nodes; (ii) how to resolve security issues associated with the harsh and complex environmental conditions during data transmission over a long coverage range. In this study, a secure IoT-based smart home automation system was developed. To facilitate energy-efficient data encryption, a method namely Triangle Based Security Algorithm (TBSA) based on efficient key generation mechanism was proposed. The proposed TBSA in integration of the low power Wi-Fi were included in WSNs with the Internet to develop a novel IoT-based smart home which could provide secure data transmission among several associated sensor nodes in the network over a long converge range. The developed IoT based system has outstanding performance by fulfilling all the necessary security requirements. The experimental results showed that the proposed TBSA algorithm consumed less energy in comparison with some existing methods.

14.
Sensors (Basel) ; 15(5): 10350-79, 2015 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-25946630

RESUMO

Our research approach is to design and develop reliable, efficient, flexible, economical, real-time and realistic wellness sensor networks for smart home systems. The heterogeneous sensor and actuator nodes based on wireless networking technologies are deployed into the home environment. These nodes generate real-time data related to the object usage and movement inside the home, to forecast the wellness of an individual. Here, wellness stands for how efficiently someone stays fit in the home environment and performs his or her daily routine in order to live a long and healthy life. We initiate the research with the development of the smart home approach and implement it in different home conditions (different houses) to monitor the activity of an inhabitant for wellness detection. Additionally, our research extends the smart home system to smart buildings and models the design issues related to the smart building environment; these design issues are linked with system performance and reliability. This research paper also discusses and illustrates the possible mitigation to handle the ISM band interference and attenuation losses without compromising optimum system performance.


Assuntos
Habitação , Algoritmos , Humanos , Monitorização Fisiológica , Telemetria , Tecnologia sem Fio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA