Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 14(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38727353

RESUMO

Polymer nanocomposite films based on poly(vinyl pyrrolidone) incorporated with different amounts of copper oxide (CuO) nanoparticles were prepared by the solution casting technique. The PVP/CuO nanocomposites were analyzed by X-ray diffractometry (XRD), scanning electron microscopy, UV-Visible absorption spectroscopy and dielectric spectroscopy. The XRD analysis showed that the monoclinic structure of cupric oxide was maintained in the PVP host matrix. The key optical parameters, such as optical energy gap Eg, Urbach energy EU, absorption coefficient and refractive index, were estimated based on the UV-Vis data. The optical characteristics of the nanocomposite films revealed that their transmittance and absorption were influenced by the addition of CuO nanoparticles in the PVP matrix. Incorporation of CuO nanoparticles into the PVP matrix led to a significant decrease in band gap energy and an increase in the refractive index. The dielectric and electrical behaviors of the PVP/CuO nanocomposites were analyzed over a frequency range between 10 Hz and 1 MHz. The effect of CuO loading on the dielectric parameters (dielectric constant and dielectric loss) of the metal oxide nanocomposites was also discussed.

2.
Open Forum Infect Dis ; 11(2): ofae039, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38328496

RESUMO

Background: The impact of vaccination prior to infection on postacute sequelae of coronavirus disease 2019 (COVID-19, PASC), also known as long COVID, remains unclear. Here we assess the protective effect of vaccination on long COVID in a community-based setting. Methods: The Immunity Associated with SARS-CoV-2 (IASO) study is an ongoing prospective cohort of working adults that began in October 2020. Participants are actively followed for severe acute respiratory syndrome coronavirus 2 infection. We compared the prevalence of symptoms and symptom severity in vaccinated compared to unvaccinated cases. Our primary definition of long COVID was the presence of symptoms at 90 days postinfection; 30 days postinfection was also examined. Results: Overall, by 90 days postinfection, 13% of cases had long COVID, with 27% of unvaccinated cases and 8% of vaccinated cases reporting long COVID (relative risk [RR], 0.31 [95% confidence interval {CI}, .22-.42]). Vaccination was also associated with significantly lower average severity scores at all timepoints (eg, relative severity at 90 days postinfection: -2.70 [95% CI, -1.68 to -3.73]). In the pre-Omicron era, 28% of unvaccinated cases and 18% of vaccinated cases reported long COVID (P = .07), and vaccinated cases reported less severe symptoms including less difficulty breathing (P = .01; 90-day RR, 0.07). Conclusions: Vaccinated cases had lower prevalence of long COVID and reduced symptom severity.

3.
Cell Host Microbe ; 32(3): 315-321.e3, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38377995

RESUMO

COVID-19 vaccines have recently been updated to specifically encode or contain the spike protein of the SARS-CoV-2 XBB.1.5 subvariant, but their immunogenicity in humans has yet to be fully evaluated and reported, particularly against emergent viruses that are rapidly expanding. We now report that administration of an updated monovalent mRNA vaccine booster (XBB.1.5 MV) to previously uninfected individuals boosted serum virus-neutralizing antibodies significantly against not only XBB.1.5 (27.0-fold increase) and EG.5.1 (27.6-fold increase) but also key emerging viruses such as HV.1, HK.3, JD.1.1, and JN.1 (13.3- to 27.4-fold increase). Individuals previously infected by an Omicron subvariant had the highest overall serum neutralizing titers (ID50 1,504-22,978) against all viral variants tested. While immunological imprinting was still evident with the updated vaccines, it was not nearly as severe as observed with the previously authorized bivalent BA.5 vaccine. Our findings strongly support the official recommendation to widely apply the updated COVID-19 vaccines.


Assuntos
Anticorpos Neutralizantes , Vacinas de mRNA , Humanos , Vacinas contra COVID-19 , Anticorpos Antivirais
4.
Lab Med ; 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38253465

RESUMO

We present 3 cases of discordant results from screening hemoglobin A1c (HbA1c) measured by ion-exchange high-performance liquid chromatography (HPLC) all due to various forms of interference and flagged by the instrument as "suspected hemoglobin E (HbE)." The first case was due to a rare hemoglobin variant, later confirmed to be hemoglobin Hoshida, the second due to "true" heterozygous HbE, and the third a result of analytical artifact causing splitting of the HbA1c peak without an underlying variant hemoglobin. We examine the similarities in these cases along with the laboratory work-up to classify each cause of interference to demonstrate the wide array of potential causes for the suspected HbE flag and why it warrants proper work-up. Because there is no standardized method of reporting out hemoglobin variant interference in HbA1c measurement, we discuss our laboratory's process of investigating discordant HbA1c measurements and reporting results in cases with variant interference as 1 possible model to follow, along with discussing the associated laboratory, ethical, and clinical considerations. We also examine the structure of hemoglobin Hoshida, HbE, and conduct a brief literature review of previous reports.

6.
Int J Mol Sci ; 24(11)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37298517

RESUMO

In recent years, organic pollutants have become a global problem due to their negative impact on human health and the environment. Photocatalysis is one of the most promising methods for the removal of organic pollutants from wastewater, and oxide semiconductor materials have proven to be among the best in this regard. This paper presents the evolution of the development of metal oxide nanostructures (MONs) as photocatalysts for ciprofloxacin degradation. It begins with an overview of the role of these materials in photocatalysis; then, it discusses methods of obtaining them. Then, a detailed review of the most important oxide semiconductors (ZnO, TiO2, CuO, etc.) and alternatives for improving their photocatalytic performance is provided. Finally, a study of the degradation of ciprofloxacin in the presence of oxide semiconductor materials and the main factors affecting photocatalytic degradation is carried out. It is well known that antibiotics (in this case, ciprofloxacin) are toxic and non-biodegradable, which can pose a threat to the environment and human health. Antibiotic residues have several negative impacts, including antibiotic resistance and disruption of photosynthetic processes.


Assuntos
Poluentes Ambientais , Nanoestruturas , Óxido de Zinco , Humanos , Ciprofloxacina/química , Óxido de Zinco/química , Nanoestruturas/química , Antibacterianos/farmacologia , Antibacterianos/química , Óxidos , Catálise
7.
Front Immunol ; 14: 1055429, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845123

RESUMO

Importance: The degree of immune protection against severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) variants provided by infection versus vaccination with wild-type virus remains unresolved, which could influence future vaccine strategies. The gold-standard for assessing immune protection is viral neutralization; however, few studies involve a large-scale analysis of viral neutralization against the Omicron variant by sera from individuals infected with wild-type virus. Objectives: 1) To define the degree to which infection versus vaccination with wild-type SARS-CoV-2 induced neutralizing antibodies against Delta and Omicron variants.2) To determine whether clinically available data, such as infection/vaccination timing or antibody status, can predict variant neutralization. Methods: We examined a longitudinal cohort of 653 subjects with sera collected three times at 3-to-6-month intervals from April 2020 to June 2021. Individuals were categorized according to SARS-CoV-2 infection and vaccination status. Spike and nucleocapsid antibodies were detected via ADVIA Centaur® (Siemens) and Elecsys® (Roche) assays, respectively. The Healgen Scientific® lateral flow assay was used to detect IgG and IgM spike antibody responses. Pseudoviral neutralization assays were performed on all samples using human ACE2 receptor-expressing HEK-293T cells infected with SARS-CoV-2 spike protein pseudotyped lentiviral particles for wild-type (WT), B.1.617.2 (Delta), and B.1.1.529 (Omicron) variants. Results: Vaccination after infection led to the highest neutralization titers at all timepoints for all variants. Neutralization was also more durable in the setting of prior infection versus vaccination alone. Spike antibody clinical testing effectively predicted neutralization for wild-type and Delta. However, nucleocapsid antibody presence was the best independent predictor of Omicron neutralization. Neutralization of Omicron was lower than neutralization of either wild-type or Delta virus across all groups and timepoints, with significant activity only present in patients that were first infected and later immunized. Conclusions: Participants having both infection and vaccination with wild-type virus had the highest neutralizing antibody levels against all variants and had persistence of activity. Neutralization of WT and Delta virus correlated with spike antibody levels against wild-type and Delta variants, but Omicron neutralization was better correlated with evidence of prior infection. These data help explain why 'breakthrough' Omicron infections occurred in previously vaccinated individuals and suggest better protection is observed in those with both vaccination and previous infection. This study also supports the concept of future SARS-CoV-2 Omicron-specific vaccine boosters.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/prevenção & controle , Técnicas e Procedimentos Diagnósticos , Anticorpos Neutralizantes , Infecções Irruptivas , Vacinas contra COVID-19 , Imunoglobulina M , Teste para COVID-19
9.
Pediatr Nephrol ; 37(3): 677-681, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34757479

RESUMO

BACKGROUND: Serum creatinine concentration is a primary component of Bedside Schwartz equation for estimated glomerular filtration rate (eGFR) in children. To standardize creatinine measurement, most manufacturers have adopted calibration procedures traceable to isotope dilution mass spectrometry (IDMS) using National Institute of Standards and Technology reference material. However, reference material representing much lower creatinine concentrations seen in children is not available and it is unclear how well commercial assays perform at pediatric levels. METHODS: One thousand nine hundred seventy-one specimens from consecutive children <19 years, with creatinine ≤0.8 mg/dL by Abbott Jaffe method were included. Creatinine measurements were compared between Abbott-Jaffe and Abbott-enzymatic methods. Furthermore, we evaluated performance of six commercial creatinine assays at concentrations seen in pediatric patients utilizing IDMS traceable serum samples. RESULTS: Median difference (enzymatic-Jaffe) for prepubertal females was -0.18 mg/dL (2.5%tile, 97.5%tile: -0.30, -0.06), -0.12 mg/dL (-0.25, -0.00) for pubertal females, -0.17  mg/dL (-0.30, -0.04) for prepubertal males, -0.11 mg/dL (-0.24, 0.01) for pubertal males. Bias appeared proportional for each subgroup and decreased as creatinine concentrations increased. Using IDMS traceable samples, the greatest inter-assay variability was seen with the lowest creatinine levels (target 0.273 mg/dL), where 67% (4/6) of methods failed to reach minimal bias specification of 8% (range -7.5 to 86%). For samples with higher creatinine targets (0.440-0.634 mg/dL), two methods failed to meet minimal bias specification, whereas four showed bias <8%. CONCLUSION: Many commonly used creatinine assays remain inaccurate for pediatric populations after over a decade of nationwide efforts to standardize measurements. When creatinine-based eGFR is used for chronic kidney disease (CKD) staging in children, large inter-assay variability can lead to disease misclassification, inappropriate diagnostic and therapeutic interventions. A higher resolution version of the Graphical abstract is available as Supplementary information.


Assuntos
Insuficiência Renal Crônica , Calibragem , Criança , Creatinina , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Espectrometria de Massas/métodos , Insuficiência Renal Crônica/diagnóstico
10.
Microbiol Spectr ; 9(2): e0008721, 2021 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-34468184

RESUMO

Uncertainty exists whether mild COVID-19 confers immunity to reinfection. Questions also remain regarding the persistence of antibodies against SARS-CoV-2 after mild infection. We prospectively followed at-risk individuals with and without SARS-CoV-2 for reinfection and monitored the spike and nucleocapsid antibodies. This prospective cohort study was conducted over two visits, 3 to 6 months apart, between May 2020 and February 2021. Adults with and without COVID-19, verified by FDA EUA-approved SARS-CoV-2 RT-PCR assays, were screened for spike and nucleocapsid antibody responses using FDA EUA-approved immunoassays and for pseudoviral neutralization activity. The subjects were monitored for symptoms, exposure to COVID-19, COVID-19 testing, seroconversion, reinfection, and vaccination. A total of 653 subjects enrolled; 129 (20%) had a history of COVID-19 verified by RT-PCR at enrollment. Most had mild disease, with only three requiring hospitalization. No initially seropositive subjects experienced a subsequent COVID-19 infection during the follow-up versus 15 infections among initially seronegative subjects (infection rates of 0.00 versus 2.05 per 10,000 days at risk [P = 0.0485]). In all, 90% of SARS-CoV-2-positive subjects produced spike and nucleocapsid responses, and all but one of these had persistent antibody levels at follow-up. Pseudoviral neutralization activity was widespread among participants, did not decrease over time, and correlated with clinical antibody assays. Reinfection with SARS-CoV-2 was not observed among individuals with mild clinical COVID-19, while infections continued in a group without known prior infection. Spike and nucleocapsid COVID-19 antibodies were associated with almost all infections and persisted at stable levels for the study duration. IMPORTANCE This article demonstrates that people who have mild COVID-19 illnesses and produce antibodies are protected from reinfection for up to 6 months afterward. The antibodies that people produce in this situation are stable for up to 6 months as well. Clinical antibody assays correlate well with evidence of antibody-related viral neutralization activity.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/prevenção & controle , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Reinfecção/prevenção & controle , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto , COVID-19/imunologia , Teste para COVID-19 , Feminino , Humanos , Imunoensaio , Masculino , Fosfoproteínas/imunologia , Estudos Prospectivos , Reinfecção/imunologia , SARS-CoV-2/imunologia
12.
Proc Natl Acad Sci U S A ; 118(27)2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-34140350

RESUMO

The spike (S) protein of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) plays a key role in viral infectivity. It is also the major antigen stimulating the host's protective immune response, specifically, the production of neutralizing antibodies. Recently, a new variant of SARS-CoV-2 possessing multiple mutations in the S protein, designated P.1, emerged in Brazil. Here, we characterized a P.1 variant isolated in Japan by using Syrian hamsters, a well-established small animal model for the study of SARS-CoV-2 disease (COVID-19). In hamsters, the variant showed replicative abilities and pathogenicity similar to those of early and contemporary strains (i.e., SARS-CoV-2 bearing aspartic acid [D] or glycine [G] at position 614 of the S protein). Sera and/or plasma from convalescent patients and BNT162b2 messenger RNA vaccinees showed comparable neutralization titers across the P.1 variant, S-614D, and S-614G strains. In contrast, the S-614D and S-614G strains were less well recognized than the P.1 variant by serum from a P.1-infected patient. Prior infection with S-614D or S-614G strains efficiently prevented the replication of the P.1 variant in the lower respiratory tract of hamsters upon reinfection. In addition, passive transfer of neutralizing antibodies to hamsters infected with the P.1 variant or the S-614G strain led to reduced virus replication in the lower respiratory tract. However, the effect was less pronounced against the P.1 variant than the S-614G strain. These findings suggest that the P.1 variant may be somewhat antigenically different from the early and contemporary strains of SARS-CoV-2.


Assuntos
COVID-19/virologia , SARS-CoV-2/fisiologia , SARS-CoV-2/patogenicidade , Replicação Viral , Animais , Anticorpos Neutralizantes , COVID-19/diagnóstico por imagem , COVID-19/patologia , Cricetinae , Humanos , Imunogenicidade da Vacina , Pulmão/patologia , Mesocricetus , Camundongos , Glicoproteína da Espícula de Coronavírus/genética , Microtomografia por Raio-X
13.
PLoS One ; 16(3): e0248729, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33725025

RESUMO

BACKGROUND: As COVID-19 vaccines become available, screening individuals for prior COVID-19 infection and vaccine response in point-of-care (POC) settings has renewed interest. We prospectively screened at-risk individuals for SARS-CoV-2 spike and nucleocapsid protein antibodies in a POC setting to determine if it was a feasible method to identify antibody from prior infection. METHODS: Three EUA-approved lateral flow antibody assays were performed on POC finger-stick blood and compared with serum and a CLIA nucleocapsid antibody immunoassay. Variables including antibody class, time since PCR, and the assay antigen used were evaluated. RESULTS: 512 subjects enrolled, of which 104 had a COVID-19 history and positive PCR. Only three PCR-positive subjects required hospitalization, with one requiring mechanical ventilation. The POC results correlated well with the immunoassay (93-97% sensitivity) and using serum did not improve the sensitivity or specificity. CONCLUSIONS: Finger-stick, POC COVID-19 antibody testing was highly effective in identifying antibody resulting from prior infections in mildly symptomatic subjects. Using high-complexity serum immunoassays did not improve the screening outcome. Almost all individuals with COVID-19 infection produced detectable antibodies to the virus. POC antibody testing is useful as a screen for prior COVID-19 infection, and should be useful in assessing vaccine response.


Assuntos
COVID-19/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Adulto , Idoso , Anticorpos Antivirais/sangue , COVID-19/virologia , Teste Sorológico para COVID-19 , Feminino , Humanos , Imunoensaio , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , Nucleocapsídeo/imunologia , Kit de Reagentes para Diagnóstico , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Adulto Jovem
14.
Am J Clin Pathol ; 155(2): 267-279, 2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33033840

RESUMO

OBJECTIVES: Serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has experienced a changing landscape of available assays coupled with uncertainty surrounding performance characteristics. Studies are needed to directly compare multiple commercially available assays. METHODS: Residual serum samples were identified based on SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR) testing, clinical test results, and collection dates. Serum samples were analyzed using assays from four different manufacturers: DiaSorin anti-SARS-CoV-2 S1/S2 IgG, EUROIMMUN anti-SARS-CoV-2 IgG ELISA, Roche Elecsys anti-SARS-CoV-2, and Siemens SARS-CoV-2 Total antibody assays. RESULTS: Samples from SARS-CoV-2 RT-PCR-positive patients became increasingly positive as time from symptom onset increased. For patients with latest sample 14 or more days after symptom onset, sensitivities reached 93.1% to 96.6%, 98.3%, and 96.6% for EUROIMMUN, Roche, and Siemens assays, respectively, which were superior to the DiaSorin assay at 87.7%. The specificity of Roche and Siemens assays was 100% and superior to DiaSorin and EUROIMMUN assays, which ranged from 96.1% to 97.0% and 86.3% to 96.4%, respectively. CONCLUSIONS: Laboratories should be aware of the advantages and limitations of serology testing options for SARS-CoV-2. The specificity and sensitivity achieved by the Roche and Siemens assays would be acceptable for testing in lower-prevalence regions and have the potential of orthogonal testing advantages if used in combination.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Ensaios de Triagem em Larga Escala/métodos , SARS-CoV-2/imunologia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Sensibilidade e Especificidade
16.
Clin Chim Acta ; 509: 126-134, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32533987

RESUMO

The homocystinurias, caused by defects of remethylation and cystathionine-beta-synthase (CBS) deficiency, are characterized by elevated homocysteine and abnormal methionine levels. Various treatments, including injectable hydroxycobalamin and oral betaine, aim to reduce homocysteine toxicity and normalize methionine, but only limited biochemical data has been reported assessing biochemical response to treatment. We analyzed laboratory results in 812 plasma samples from 56 patients with remethylation disorders and 67 patients with CBS deficiency. Total plasma homocysteine (tHcys) decreased with therapy, but rarely normalized regardless of treatment, with highest levels seen in CBS (116 ±â€¯79 µmol/L) and MTHFR (102 ±â€¯56 µmol/L) deficiencies. In CBS deficiency, tHcys correlated positively with methionine (rs = 0.51, p < 0.0001) and inversely with cystine (rs = -0.57, p < 0.0001) consistent with a metabolic block downstream of homocysteine. In patients with remethylation disorders, methionine was mostly normal on therapy, and inversely correlated with tHcys (rs = -0.57, p < 0.0001) demonstrating effectiveness of hydroxycobalamin and/or betaine in stimulating tHcys remethylation. Betaine also significantly increased sarcosine from its pre-treatment level on average 19-fold in remethylation disorders and 3-fold in CBS deficiency, with sarcosine > 5 µmol/L being 97% sensitive and 95% specific for betaine therapy. These results show that existing therapies improve sulfur amino acid metabolism without completely normalizing it and that sarcosine can determine compliance to betaine supplementation.


Assuntos
Homocisteína , Homocistinúria , Betaína , Cistationina beta-Sintase , Seguimentos , Homocisteína/metabolismo , Homocistinúria/tratamento farmacológico , Humanos , Laboratórios , Metionina , Metilação
17.
J Biol Chem ; 295(28): 9630-9640, 2020 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-32457044

RESUMO

In humans, cobalamin or vitamin B12 is delivered to two target enzymes via a complex intracellular trafficking pathway comprising transporters and chaperones. CblC (or MMACHC) is a processing chaperone that catalyzes an early step in this trafficking pathway. CblC removes the upper axial ligand of cobalamin derivatives, forming an intermediate in the pathway that is subsequently converted to the active cofactor derivatives. Mutations in the cblC gene lead to methylmalonic aciduria and homocystinuria. Here, we report that nitrosylcobalamin (NOCbl), which was developed as an antiproliferative reagent, and is purported to cause cell death by virtue of releasing nitric oxide, is highly unstable in air and is rapidly oxidized to nitrocobalamin (NO2Cbl). We demonstrate that CblC catalyzes the GSH-dependent denitration of NO2Cbl forming 5-coordinate cob(II)alamin, which had one of two fates. It could be oxidized to aquo-cob(III)alamin or enter a futile thiol oxidase cycle forming GSH disulfide. Arg-161 in the active site of CblC suppressed the NO2Cbl-dependent thiol oxidase activity, whereas the disease-associated R161G variant stabilized cob(II)alamin and promoted futile cycling. We also report that CblC exhibits nitrite reductase activity, converting cob(I)alamin and nitrite to NOCbl. Finally, the denitration activity of CblC supported cell proliferation in the presence of NO2Cbl, which can serve as a cobalamin source. The newly described nitrite reductase and denitration activities of CblC extend its catalytic versatility, adding to its known decyanation and dealkylation activities. In summary, upon exposure to air, NOCbl is rapidly converted to NO2Cbl, which is a substrate for the B12 trafficking enzyme CblC.


Assuntos
Nitrito Redutases , Oxirredutases , Vitamina B 12/análogos & derivados , Transporte Biológico Ativo , Catálise , Células HT29 , Humanos , Nitrito Redutases/química , Nitrito Redutases/metabolismo , Oxirredutases/química , Oxirredutases/metabolismo , Ligação Proteica , Vitamina B 12/química , Vitamina B 12/metabolismo
18.
J Anal Toxicol ; 43(4): 284-290, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476143

RESUMO

Heavy metals testing remains an ongoing challenge for diagnosing acute or chronic exposure to heavy metals. In this study, we determined the positivity rates of single element and panel testing for toxic elements, and evaluated the potential utility of an expanded detection protocol for screening of toxic element exposures. The retrospective analysis included data from urine (n = 19,343) and blood (n = 196,019) specimens tested using inductively coupled plasma-mass spectrometry (ICP-MS) for arsenic, cadmium, lead and mercury (blood), and arsenic, cadmium, copper, lead, mercury and zinc (urine). Lead industrial monitoring in blood and cadmium exposure in blood and urine were included to represent directed single element ordering. The percent of positive results, defined as results greater than the upper limit of the reference interval was determined. For blood, the highest positivity was observed for lead occupational exposure monitoring (26.2%) whereas for urine, the highest positivity was observed for zinc testing (28.1%). Remarkably, reanalysis using an expanded panel, of 120 blood and 174 urine specimens originally negative identified 42% (50 of 120) of the blood specimens with at least one elevated result and 48% (83 of 174) of the urine specimens with at least one elevated result. Our results indicate that a broad elemental screening panel may help ensure easier identification of elemental exposure and may eliminate the need for additional follow-up sample collections.


Assuntos
Monitoramento Ambiental/métodos , Metais Pesados/sangue , Metais Pesados/urina , Exposição Ocupacional/análise , Doenças Assintomáticas , Intoxicação por Metais Pesados/diagnóstico , Humanos , Técnicas de Diluição do Indicador , Chumbo/sangue , Espectrometria de Massas , Estudos Prospectivos , Estudos Retrospectivos , Zinco/urina
19.
Angew Chem Int Ed Engl ; 56(26): 7387-7392, 2017 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-28544088

RESUMO

B12 antivitamins are important and robust tools for investigating the biological roles of vitamin B12 . Here, the potential antivitamin B12 2,4-difluorophenylethynylcobalamin (F2PhEtyCbl) was prepared, and its 3D structure was studied in solution and in the crystal. Chemically inert F2PhEtyCbl resisted thermolysis of its Co-C bond at 100 °C, was stable in bright daylight, and also remained intact upon prolonged storage in aqueous solution at room temperature. It binds to the human B12 -processing enzyme CblC with high affinity (KD =130 nm) in the presence of the cosubstrate glutathione (GSH). F2PhEtyCbl withstood tailoring by CblC, and it also stabilized the ternary complex with GSH. The crystal structure of this inactivated assembly provides first insight into the binding interactions between an antivitamin B12 and CblC, as well as into the organization of GSH and a base-off cobalamin in the active site of this enzyme.


Assuntos
Glutationa/química , Vitamina B 12/antagonistas & inibidores , Domínio Catalítico , Cristalografia por Raios X , Flúor/química , Humanos , Hidrólise , Cinética , Modelos Moleculares , Estrutura Molecular , Análise Espectral/métodos , Especificidade por Substrato , Temperatura , Vitamina B 12/química , Vitamina B 12/farmacologia
20.
J Biol Chem ; 291(15): 8004-13, 2016 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-26867575

RESUMO

Cystathionine ß-synthase (CBS) is a pyridoxal phosphate-dependent enzyme that catalyzes the condensation of homocysteine with serine or with cysteine to form cystathionine and either water or hydrogen sulfide, respectively. Human CBS possesses a noncatalytic heme cofactor with cysteine and histidine as ligands, which in its oxidized state is relatively unreactive. Ferric CBS (Fe(III)-CBS) can be reduced by strong chemical and biochemical reductants to Fe(II)-CBS, which can bind carbon monoxide (CO) or nitric oxide (NO(•)), leading to inactive enzyme. Alternatively, Fe(II)-CBS can be reoxidized by O2to Fe(III)-CBS, forming superoxide radical anion (O2 (̇̄)). In this study, we describe the kinetics of nitrite (NO2 (-)) reduction by Fe(II)-CBS to form Fe(II)NO(•)-CBS. The second order rate constant for the reaction of Fe(II)-CBS with nitrite was obtained at low dithionite concentrations. Reoxidation of Fe(II)NO(•)-CBS by O2showed complex kinetic behavior and led to peroxynitrite (ONOO(-)) formation, which was detected using the fluorescent probe, coumarin boronic acid. Thus, in addition to being a potential source of superoxide radical, CBS constitutes a previously unrecognized source of NO(•)and peroxynitrite.


Assuntos
Cistationina beta-Sintase/metabolismo , Heme/metabolismo , Nitritos/metabolismo , Ácido Peroxinitroso/metabolismo , Monóxido de Carbono/metabolismo , Cistationina beta-Sintase/química , Heme/química , Humanos , Cinética , Óxido Nítrico/metabolismo , Oxirredução , Oxigênio/metabolismo , Superóxidos/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA