Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Indian J Nucl Med ; 38(4): 328-333, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38390539

RESUMO

Context: The impaired ability of thyroid cancer (TC) cells to uptake and concentrate iodine represents a major therapeutic challenge in malignant TC management. This has been reported probably due to reduced or loss of expression of pendrin in thyroid tumors. Aims: In view of this, we evaluated the pendrin expression in the chemically induced (using N-bis[2-hydroxypropyl] nitrosamine [DHPN]) TC model in Wistar rats. Methods: Uptake in the thyroid gland was evaluated by positron emission tomography with computed tomography (PET-CT) and scintigraphy imaging. Further histopathology (HP) and immunohistochemistry (IHC) were performed for confirming malignancy. Results: The altered uptake in the thyroid gland was observed by PET-CT and scintigraphy imaging. Significant pathological changes in the thyroid were observed using 2-deoxy-2-(fluorine-18) fluoro-D-glucose PET-CT, technetium-99m pertechnetate imaging, and reduced iodine-131 uptake (n = 4) in DHPN-induced animals compared to control indicative of thyroid cell proliferation. In treated groups, tissue HP revealed hyperplastic follicular to papillary cell proliferation with variable mitotic activity. The malignant nature of the tissue and variable uptake of the tracer were further reconfirmed by IHC. IHC revealed reduced pendrin expression in malignant thyroid tissue. Conclusions: Hence, nuclear imaging techniques can be of aid in the early identification and evaluation of cellular changes during the early development of tumor models in laboratory animals. In conclusion, our study reveals that pendrin expression plays a vital role in thyroid uptake, and its reduction was observed in TC in a chemically induced TC model.

2.
Indian J Clin Biochem ; 37(4): 473-479, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36262779

RESUMO

Four anti-thyroglobulin autoantibodies (TgAb) assays were evaluated for their reference interval, method agreement, concordance etc. Prevalence of TgAb and anti-thyroid peroxidase was studied in differentiated thyroid cancer (DTC) and control. Reference intervals for TgAb assays varied from method to method due to varied assay designs. For TgAb correlation coefficients ranged from 0.74 to 0.99 whereas concordance ranged from 81 to 96.1%. Prevalence of thyroid antibodies mainly TgAb was increased in DTC primarily in females. Use of sensitive immunoassays is recommended for thyroid autoantibody measurement. Diagnosis and follow-up are difficult in DTC with coexisting thyroid autoimmunity. Hence, careful monitoring with regular surveillance is suggested.

3.
J Immunol Methods ; 492: 112990, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33561431

RESUMO

Single- domain antibodies (SdAbs) have been deployed in various biomedical applications in the recent past. However, there are no reports of their use in the immunoradiometric assays (IRMA) for thyroglobulin (Tg). Tg is the precursor molecule for the biosynthesis of thyroid hormones: thyroxine and triiodothyronine, which are essential for the regulation of normal metabolism in all vertebrates. Patients with differentiated thyroid cancer (DTC) require periodic monitoring of their serum thyroglobulin levels, as it serves as a prognostic marker for DTC. Here, we report a methodology to produce SdAbs against human-Tg, by a hybrid immunization/directed-evolution approach by displaying the SdAb gene-repertoire derived from a hyperimmune camel in the T7 phage display system. We have demonstrated the immunoreactivity of anti-Tg-SdAb (KT75) in immunoassays for thyroglobulin and measured its affinity by surface plasmon resonance (KD ~ 18 picomolar). Additionally, we have shown the quantitative-binding property of SdAb for the first time in IRMA for thyroglobulin. The serum Tg values obtained from SdAb-Tg-IRMA and in-house assay using murine anti-Tg-monoclonal antibody as tracer significantly correlated, r = 0.81, p < 0.05. Our results highlight the scope of using the T7 phage display system as an alternative for the conventional M13-phage to construct single-domain antibody display libraries.


Assuntos
Ensaio Imunorradiométrico/métodos , Anticorpos de Domínio Único/imunologia , Tireoglobulina/análise , Neoplasias da Glândula Tireoide/diagnóstico , Animais , Bacteriófago T7 , Camelus , Humanos , Masculino , Biblioteca de Peptídeos , Anticorpos de Domínio Único/isolamento & purificação , Tireoglobulina/imunologia , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/sangue , Neoplasias da Glândula Tireoide/patologia
4.
Indian J Clin Biochem ; 34(4): 465-471, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31686734

RESUMO

Thyroglobulin (Tg) is a proven tumor marker in the follow-up and post-operative management of patients with differentiated thyroid cancer (DTC). All assays for serum thyroglobulin (s-Tg) are based on immunoassays, however, the assay technique has a bearing on the variations seen in the estimations. We studied this using four in-house developed radioimmunoassays (RIA) and immunoradiometric assays (IRMA). Limit of detection, working range, recovery, dilution test, precision profiles and method comparison were evaluated. All four methods were used for the estimation of s-Tg in DTC patients and also compared for their performance using commercially available Tg IRMA kits from DiaSorin and Izotop. The s-Tg values measured by six different immunoassays showed very significant inter-method correlation (0.84-0.99, p < 0.001). However, among the in-house developed assays; the coated tube IRMA showed a better sensitivity and precision at the lower concentration range and hence, is preferable for the routine measurement of s-Tg in patients negative for Tg autoantibodies (TgAb). Although the second generation IRMAs offer practical benefits of having higher sensitivity, shorter turn-around time and convenience of automation, they, unfortunately, also have higher tendency for interference from both TgAb and heterophilic antibodies, if present in the sample. On the contrary, RIA is less prone to such interference and, hence, can be used in patients with TgAb. In order to effectively use this test, it is important that nuclear medicine physicians and endocrinologists understand these intrinsic technical limitations encountered during s-Tg measurement.

5.
Indian J Clin Biochem ; 32(2): 193-199, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28428694

RESUMO

Serum thyroglobulin (Tg) and thyroid stimulating hormone (TSH) measurements have evolved as important analytes for monitoring the prognosis of patients with differentiated thyroid cancer, post-thyroidectomy. Individual analyte immunoassay is the current practice in clinical pathology, but the simultaneous assay for all relevant analytes for a given disease, can reduce assay costs, improve patient compliance and give the clinician more information for an unequivocal diagnosis. Microarray immunoassay (MI) can achieve this goal and, hence, we have developed and validated a immuno-radiometric MI for quantitation of serum TSH and Tg by using highly micro-porous polycarbonate (PC) track-etched membranes (TEM) to immobilize the monoclonal anti-TSH and polyclonal anti-Tg antibodies in ~1 mm diameter spots. Non-competitive immunoassays were performed using mixture of 125I labeled monoclonal anti-TSH and anti-Tg antibodies. Phosphorimager was used to quantify the bound radioactivity. TSH and Tg were detected with detection limit of 0.07 µIU/ml and 0.13 ng/ml respectively, which is lower than the clinically required cut-off level. The assay showed: acceptable intra-assay precision within 20 % and recovery in the range of 76-111.2 %. MI compared well with the established immunoradiometric assay (IRMA) with r = 0.98, p < 0.01 (n = 41). No cross-reactivity was seen between the immobilized antibodies. Although two hormones are addressed in this report, MI using PC TEM and isotopic/non-isotopic tracers has the potential for highly automated multiplexed analysis.

6.
Indian J Clin Biochem ; 32(1): 39-44, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28149011

RESUMO

Thyroglobulin autoantibodies (TgAb) are estimated to detect potential interferences in thyroglobulin (Tg) immunoassays and also for the diagnosis of autoimmune thyroid disease. A user friendly and robust in-house solid-phase radioassay was standardized and parameters like sensitivity, reproducibility and stability were assessed. Further, it was validated and evaluated for the detection of autoantibodies in differentiated thyroid cancer (DTC) patients. Totally 301 samples received in our laboratory for routine serum Tg estimation were studied. The samples were analyzed for TgAb by the solid-phase radioassay developed in-house and compared with commercial anti-hTg IRMA kit (Immunotech, France). The control group comprised of 37 euthyroid males from our Centre. The intra- and inter-assay CVs for the two quality control samples (Control A = 104 ± 12.6 IU/mL and Control B = 1029 ± 114 IU/mL) were found less than or equal to 6.05 and 13.85 % respectively. Solid-phase radioassay showed a good agreement on comparison with Immunotech IRMA (r = 0.99). Using the proposed cut-off thresholds (in-house solid-phase radioassay 52 IU/mL and Immunotech IRMA 30 IU/mL), 5.4 % of the control subjects were positive for TgAb by both the methods. Prevalence of TgAb in DTC patients was 17.3 and 16.6 % using the Immunotech kit and in-house solid-phase radioassay respectively. The in-house solid-phase radioassay has the requisite sensitivity for the evaluation of TgAb comparable to commercial kit and also suitable for routine use as it is rapid, user friendly and economical.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA