Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38801398

RESUMO

AIMS: As transcatheter mitral valve (MV) interventions are expanding and more device types and sizes become available, a tool supporting operators in preprocedural planning and the clinical decision-making process is highly desirable. We sought to develop a finite element (FE) computational simulation model to predict results of transcatheter edge-to-edge (TEER) interventions. METHODS AND RESULTS: We prospectively enrolled patients with secondary mitral regurgitation (MR) referred for a clinically indicated TEER. Three-dimensional (3D) transesophageal echocardiograms performed at the beginning of the procedure were used to perform the simulation. On the 3D dynamic model of the MV that was first obtained, we simulated the clip implantation using the same clip(s) type, size, number, and implantation location that was used during the intervention. The 3D model of the MV obtained after simulation of the clip implantation was compared to the clinical results obtained at the end of the intervention. We analyzed the degree and location of residual MR and the shape and area of the diastolic mitral valve area. We performed computational simulation on 5 patients. Overall, the simulated models predicted well the degree and location of the residual regurgitant orifice(s) but tended to underestimate the diastolic mitral orifice area. CONCLUSIONS: In this proof-of-concept study, we present preliminary results on our algorithm simulating clip implantation in 5 patients with functional MR. We show promising results regarding the feasibility and accuracy in terms of predicting residual MR and the need to improve the estimation of the diastolic mitral valve area.

2.
Arch Cardiovasc Dis ; 115(10): 505-513, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36123284

RESUMO

BACKGROUND: Randomized trials comparing the first-generation absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA) with a drug-eluting stent showed a moderate but significant increase in the rate of 3-year major adverse cardiac events and scaffold thrombosis, followed by a decrease in adverse events after 3 years. AIM: The objective of this study was to assess the 5-year outcomes of patients treated with at least one absorb BVS and included in the FRANCE ABSORB registry. METHODS: All patients treated in France with an absorb BVS were prospectively included in a large nationwide multicentre registry. The primary efficacy outcome was the occurrence of 5-year major adverse cardiac events. Secondary efficacy outcomes were the rates of 5-year target vessel revascularization and definite/probable scaffold thrombosis. RESULTS: Between September 2014 and April 2016, 2,070 patients were included in 86 centres (mean age 55±11 years; 80% men; 49% with acute coronary syndrome). The rates of 1-, 3- and 5-year major adverse cardiac events were 3.9%, 9.4% and 12.1%, respectively (including cardiac death in 2.5% and target vessel revascularization in 10.4%). By multivariable analysis, diabetes, oral anticoagulation, the use of multiple Absorb BVSs and the use of a 2.5mm diameter absorb BVS were associated with 5-year major adverse cardiac events. The rates of 1-, 3- and 5-year definite/probable scaffold thrombosis were 1.5%, 3.1% and 3.6%, respectively. By multivariable analysis, older age, diabetes, anticoagulation at discharge and the use of a 2.5mm diameter absorb BVS were associated with 5-year scaffold thrombosis. CONCLUSIONS: Absorb BVS implantation was associated with low rates of 1-year major adverse cardiac events, which increased significantly at 3-year follow-up. There was a clear decrease in the rates of scaffold thrombosis and major adverse cardiac events after 3 years.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Implantes Absorvíveis , Everolimo , Resultado do Tratamento , Desenho de Prótese , Fatores de Tempo , Sistema de Registros , Anticoagulantes , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
4.
J Vasc Surg Cases Innov Tech ; 7(4): 750-754, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34786530

RESUMO

Three-dimensionally (3D) printed models have been increasingly used in medicine. Few reports have focused on prototype experiments, especially in aortic surgery. Although endovascular repairs are routinely performed for thoracoabdominal aortic aneurysms and lesions involving the aortic arch, endovascular treatment of the ascending aorta is still at an early stage of development. Using a 3D model, based on patient computed tomography scans and manufactured by Biomodex (Paris, France), we performed a patient-specific rehearsal of an endovascular Bentall repair to treat an ascending aorta aneurysm involving the aortic root. We achieved a patient-specific proof of concept of a new technique using an in vitro 3D model.

5.
JACC Cardiovasc Interv ; 14(15): 1704-1713, 2021 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-34274294

RESUMO

OBJECTIVES: Using French transcatheter aortic valve replacement (TAVR) registries linked with the nationwide administrative databases, the study compared the rates of long-term mortality, bleeding, and ischemic events after TAVR in patients requiring oral anticoagulation with direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs). BACKGROUND: The choice of optimal drug for anticoagulation after TAVR remains debated. METHODS: Data from the France-TAVI and FRANCE-2 registries were linked to the French national health single-payer claims database, from 2010 to 2017. Propensity score matching was used to reduce treatment-selection bias. Two primary endpoints were death from any cause (efficacy) and major bleeding (safety). RESULTS: A total of 24,581 patients who underwent TAVR were included and 8,962 (36.4%) were treated with OAC. Among anticoagulated patients, 2,180 (24.3%) were on DOACs. After propensity matching, at 3 years, mortality (hazard ratio [HR]: 1.37; 95% confidence interval [CI]: 1.12-1.67; P < 0.005) and major bleeding including hemorrhagic stroke (HR: 1.64; 95% CI: 1.17-2.29; P < 0.005) were lower in patients on DOACs compared with those on VKAs. The rates of ischemic stroke (HR: 1.32; 95% CI: 0.81-2.15; P = 0.27) and acute coronary syndrome (HR: 1.17; 95% CI: 0.68-1.99; P = 0.57) did not differ among groups. CONCLUSIONS: In these large multicenter French TAVR registries with an exhaustive clinical follow-up, the long-term mortality and major bleeding were lower with DOACs than VKAs at discharge. The present study supports preferential use of DOACs rather than VKAs in patients requiring oral anticoagulation therapy after TAVR.


Assuntos
Fibrilação Atrial , Substituição da Valva Aórtica Transcateter , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Vitamina K
6.
EuroIntervention ; 16(10): 842-849, 2020 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-32310129

RESUMO

AIMS: No randomised study comparing the outcomes of transcarotid (TC) and transaxillary (TAx) TAVR has been conducted to date. The purpose of this study was to understand which approach should be the preferred alternative by comparing their outcomes using a propensity-matched comparison in a French multicentre registry. METHODS AND RESULTS: From 2010 to 2018, a French multicentre prospective registry included 502 patients, with 374 undergoing TC-TAVR and 128 TAx-TAVR for symptomatic aortic stenosis. Patients treated through TAx access were matched 1:2 with patients treated through the TC route by using a propensity score (20 clinical, anatomical and procedural variables) and by date of the procedure. The first outcome was mortality at one-month follow-up. The second outcome was one-month stroke/transient ischaemic attack (TIA). In propensity-matched analyses, the incidence of the primary outcome was similar in the TAx and TC groups (TAx 5.5% vs TC 4.5%, OR 1.23, 95% CI: 0.40-3.70). The secondary outcome was similar in TAx (3.2%) and TC (6.8%, OR 0.52, 95% CI: 0.14-1.84). Minor bleeding (2.7% vs 9.3%, OR 0.26, 95% CI: 0.07-0.92) and main access haematoma (3.6% vs 10.3%, OR 0.034, 95% CI: 0.09-0.92) were significantly more frequent with the TC access. One-month clinical efficacy and safety and one-year mortality did not differ according to the different routes. CONCLUSIONS: One-month mortality, one-month stroke/TIA and one-year mortality are similar with TAx-TAVR and TC-TAVR. However, TC-TAVR is accompanied by more minor bleeding and main access haematoma compared with the transaxillary route.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Circulation ; 141(4): 243-259, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31736356

RESUMO

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Assuntos
Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Taxa de Sobrevida
8.
BMJ ; 365: l1945, 2019 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-31189617

RESUMO

OBJECTIVE: To determine whether coronary computed tomography angiography (CTA) should be performed in patients with any clinical probability of coronary artery disease (CAD), and whether the diagnostic performance differs between subgroups of patients. DESIGN: Prospectively designed meta-analysis of individual patient data from prospective diagnostic accuracy studies. DATA SOURCES: Medline, Embase, and Web of Science for published studies. Unpublished studies were identified via direct contact with participating investigators. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Prospective diagnostic accuracy studies that compared coronary CTA with coronary angiography as the reference standard, using at least a 50% diameter reduction as a cutoff value for obstructive CAD. All patients needed to have a clinical indication for coronary angiography due to suspected CAD, and both tests had to be performed in all patients. Results had to be provided using 2×2 or 3×2 cross tabulations for the comparison of CTA with coronary angiography. Primary outcomes were the positive and negative predictive values of CTA as a function of clinical pretest probability of obstructive CAD, analysed by a generalised linear mixed model; calculations were performed including and excluding non-diagnostic CTA results. The no-treat/treat threshold model was used to determine the range of appropriate pretest probabilities for CTA. The threshold model was based on obtained post-test probabilities of less than 15% in case of negative CTA and above 50% in case of positive CTA. Sex, angina pectoris type, age, and number of computed tomography detector rows were used as clinical variables to analyse the diagnostic performance in relevant subgroups. RESULTS: Individual patient data from 5332 patients from 65 prospective diagnostic accuracy studies were retrieved. For a pretest probability range of 7-67%, the treat threshold of more than 50% and the no-treat threshold of less than 15% post-test probability were obtained using CTA. At a pretest probability of 7%, the positive predictive value of CTA was 50.9% (95% confidence interval 43.3% to 57.7%) and the negative predictive value of CTA was 97.8% (96.4% to 98.7%); corresponding values at a pretest probability of 67% were 82.7% (78.3% to 86.2%) and 85.0% (80.2% to 88.9%), respectively. The overall sensitivity of CTA was 95.2% (92.6% to 96.9%) and the specificity was 79.2% (74.9% to 82.9%). CTA using more than 64 detector rows was associated with a higher empirical sensitivity than CTA using up to 64 rows (93.4% v 86.5%, P=0.002) and specificity (84.4% v 72.6%, P<0.001). The area under the receiver-operating-characteristic curve for CTA was 0.897 (0.889 to 0.906), and the diagnostic performance of CTA was slightly lower in women than in with men (area under the curve 0.874 (0.858 to 0.890) v 0.907 (0.897 to 0.916), P<0.001). The diagnostic performance of CTA was slightly lower in patients older than 75 (0.864 (0.834 to 0.894), P=0.018 v all other age groups) and was not significantly influenced by angina pectoris type (typical angina 0.895 (0.873 to 0.917), atypical angina 0.898 (0.884 to 0.913), non-anginal chest pain 0.884 (0.870 to 0.899), other chest discomfort 0.915 (0.897 to 0.934)). CONCLUSIONS: In a no-treat/treat threshold model, the diagnosis of obstructive CAD using coronary CTA in patients with stable chest pain was most accurate when the clinical pretest probability was between 7% and 67%. Performance of CTA was not influenced by the angina pectoris type and was slightly higher in men and lower in older patients. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42012002780.


Assuntos
Angina Pectoris/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Angina Pectoris/etiologia , Doença da Artéria Coronariana/complicações , Estudos de Viabilidade , Humanos , Valor Preditivo dos Testes , Probabilidade
9.
JACC Cardiovasc Interv ; 12(5): 413-419, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30772290

RESUMO

OBJECTIVES: This study sought to describe the procedural and clinical outcomes of patients undergoing transcarotid (TC) transcatheter aortic valve replacement (TAVR) with the Edwards Sapien 3 device. BACKGROUND: The TC approach for TAVR holds the potential to become the optimal alternative to the transfemoral gold standard. Limited data exist regarding safety and efficacy of TC-TAVR using the Edwards Sapien 3 device. METHODS: The French Transcarotid TAVR prospective multicenter registry included patients between 2014 and 2018. Consecutive patients treated in 1 of the 13 participating centers ineligible for transfemoral TAVR were screened for TC-TAVR. Clinical and echocardiographic data were prospectively collected. Perioperative and 30-day outcomes were reported according to the updated Valve Academic Research Consortium (VARC-2). RESULTS: A total of 314 patients were included with a median (interquartile range) age of 83 (78 to 88) years, 63% were males, Society of Thoracic Surgeons mortality risk score 5.8% (4% to 8.3%). Most patients presented with peripheral artery disease (64%). TC-TAVR was performed under general anesthesia in 91% of cases, mostly using the left carotid artery (73.6%) with a procedural success of 97%. Three annulus ruptures were reported, all resulting in patient death. At 30 days, rates of major bleeding, new permanent pacemaker, and stroke or transient ischemic attack were 4.1%, 16%, and 1.6%, respectively. The 30-day mortality was 3.2%. CONCLUSIONS: TC-TAVR using the Edwards Sapien 3 device was safe and effective in this prospective multicenter registry. The TC approach might be considered, in selected patients, as the first-line alternative approach for TAVR whenever the transfemoral access is prohibited. Sapien 3 device was safe and effective in our multicenter cohort.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artérias Carótidas , Cateterismo Periférico , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , França , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Desenho de Prótese , Punções , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Arch Cardiovasc Dis ; 112(2): 113-123, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30630761

RESUMO

BACKGROUND: Several randomized studies have shown that bioresorbable vascular scaffold (BVS) technology is associated with an increased risk of stent thrombosis. AIM: This study aimed to assess the rates of adverse outcomes at 1 year in patients treated with the Absorb BVS (Abbott Vascular, Santa Clara, CA, USA), using data from a large nationwide prospective multicentre registry (FRANCE ABSORB). METHODS: All patients receiving the Absorb BVS in France were included prospectively in the study. Predilatation, optimal sizing and postdilatation were recommended systematically. The primary endpoint was a composite of cardiovascular death, myocardial infarction and target lesion revascularization at 1 year. Secondary endpoints were scaffold thrombosis and target vessel revascularization at 1 year. RESULTS: A total of 2072 patients at 86 centres were included: mean age 55±11 years; 80% men. The indication was acute coronary syndrome (ACS) in 49% of cases. Predilatation and postdilatation were done in 93% and 83% of lesions, respectively. At 1 year, the primary endpoint occurred in 3.9% of patients, the rate of scaffold thrombosis was 1.5% and the rate of target vessel revascularization was 3.3%. In a multivariable analysis, diabetes and total Absorb BVS length>30mm were independently associated with the occurrence of the primary endpoint, whereas oral anticoagulation and total Absorb BVS length>30mm were independently associated with occurrence of scaffold thrombosis. CONCLUSIONS: The Absorb BVS was implanted in a relatively young population, half of whom had ACS. Predilatation and postdilatation rates were high, and 1-year outcomes were acceptable.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/cirurgia , Angina Instável/cirurgia , Angioplastia Coronária com Balão/instrumentação , Infarto do Miocárdio/cirurgia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Adulto , Idoso , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Trombose Coronária/etiologia , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Estudos Prospectivos , Desenho de Prótese , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Circulation ; 138(23): 2597-2607, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30571260

RESUMO

BACKGROUND: The FRANCE-2 registry (French Aortic National Corevalve and Edwards) previously reported good early- and medium-term clinical and echocardiographic efficacy for transcatheter aortic valve replacement. We here report 5-year follow-up results from the registry. METHODS: The registry includes all consecutive patients undergoing transcatheter aortic valve replacement for severe aortic stenosis in France. Follow-up is scheduled at 30 days, 6 months, then annually from 1 to 5 years. Clinical events were defined according to the Valve Academic Research Consortium criteria, and hemodynamic structural valve deterioration (SVD) was defined according to the consensus statement by the European Association of Percutaneous Cardiovascular Interventions. RESULTS: Between January 2010 and January 2012, 4201 patients were enrolled in 34 centers. Five-year vital status was available for 95.5% of patients; 88.1% had clinical evaluation or died. Overall, at 5 years, all-cause mortality was 60.8% (n=2478; 95% CI, 59.3% to 62.3%). The majority of cardiovascular events occurred in the first month after valve implantation, and incidence remained low thereafter, at <2% per year up to 5 years, except for heart failure. The rate of heart failure was 14.3% at 1 year, then decreased over time to <5% per year. In cumulative incidence function, the rates of severe SVD and moderate/severe SVD at 5 years were 2.5% and 13.3%, respectively. Mortality did not differ between patients with or without severe SVD (hazard ratio, 0.71; 95% CI, 0.47-1.07; P=0.1). Finally, in the population of patients with severe SVD, 1 patient (1.7%) experienced a stroke, and 8 patients presented ≥1 heart failure event (13.3%). CONCLUSIONS: The 5-year follow-up results of the FRANCE-2 registry represent the largest long-term data set available in a high-risk population. In surviving patients, the low rate of clinical events and the low level of SVD after 1 year support the long-term efficacy of transcatheter aortic valve replacement in both types of transcatheter prosthesis featuring in the registry.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Falha de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Hemodinâmica , Humanos , Masculino , Modelos de Riscos Proporcionais , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
12.
BMC Cardiovasc Disord ; 18(1): 193, 2018 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-30340532

RESUMO

BACKGROUND: Experimental studies suggest that morphine may protect the myocardium against ischemia-reperfusion injury by activating salvage kinase pathways. The objective of this two-center, randomized, double-blind, controlled trial was to assess potential cardioprotective effects of intra-coronary morphine in patients with ST-segment elevation myocardial infarction (STEMI) referred for primary percutaneous intervention. METHODS: Ninety-one patients with STEMI were randomly assigned to intracoronary morphine (1 mg) or placebo at reperfusion of the culprit coronary artery. The primary endpoint was infarct size/left ventricular mass ratio assessed by magnetic resonance imaging on day 3-5. Secondary endpoints included the areas under the curve (AUC) for troponin T and creatine kinase over three days, left ventricular ejection fraction assessed by echocardiography on days 1 and 6, and clinical outcomes. RESULTS: Infarct size/left ventricular mass ratio was not significantly reduced by intracoronary morphine compared to placebo (27.2% ± 15.0% vs. 30.5% ± 10.6%, respectively, p = 0.28). Troponin T and creatine kinase AUCs were similar in the two groups. Morphine did not improve left ventricular ejection fraction on day 1 (49.7 ± 10.3% vs. 49.3 ± 9.3% with placebo, p = 0.84) or day 6 (48.5 ± 10.2% vs. 49.0 ± 8.5% with placebo, p = 0.86). The number of major adverse cardiac events, including stent thrombosis, during the one-year follow-up was similar in the two groups. CONCLUSIONS: Intracoronary morphine at reperfusion did not significantly reduce infarct size or improve left ventricular systolic function in patients with STEMI. Presence of comorbidities in some patients may contribute to explain these results. TRIAL REGISTRATION: ClinicalTrials.gov, NCT01186445 (date of registration: August 23, 2010).


Assuntos
Morfina/administração & dosagem , Intervenção Coronária Percutânea , Substâncias Protetoras/administração & dosagem , Idoso , Método Duplo-Cego , Feminino , França , Humanos , Injeções Intra-Arteriais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Morfina/efeitos adversos , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Traumatismo por Reperfusão Miocárdica/etiologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Miocárdio/patologia , Intervenção Coronária Percutânea/efeitos adversos , Substâncias Protetoras/efeitos adversos , Recuperação de Função Fisiológica , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Volume Sistólico/efeitos dos fármacos , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda/efeitos dos fármacos
13.
Eur Radiol ; 28(11): 4919-4921, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29858635

RESUMO

The original version of this article, published on 19 March 2018, unfortunately contained a mistake. The following correction has therefore been made in the original: The names of the authors Philipp A. Kaufmann, Ronny Ralf Buechel and Bernhard A. Herzog were presented incorrectly.

14.
Eur Radiol ; 28(9): 4006-4017, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29556770

RESUMO

OBJECTIVES: To analyse the implementation, applicability and accuracy of the pretest probability calculation provided by NICE clinical guideline 95 for decision making about imaging in patients with chest pain of recent onset. METHODS: The definitions for pretest probability calculation in the original Duke clinical score and the NICE guideline were compared. We also calculated the agreement and disagreement in pretest probability and the resulting imaging and management groups based on individual patient data from the Collaborative Meta-Analysis of Cardiac CT (CoMe-CCT). RESULTS: 4,673 individual patient data from the CoMe-CCT Consortium were analysed. Major differences in definitions in the Duke clinical score and NICE guideline were found for the predictors age and number of risk factors. Pretest probability calculation using guideline criteria was only possible for 30.8 % (1,439/4,673) of patients despite availability of all required data due to ambiguity in guideline definitions for risk factors and age groups. Agreement regarding patient management groups was found in only 70 % (366/523) of patients in whom pretest probability calculation was possible according to both models. CONCLUSIONS: Our results suggest that pretest probability calculation for clinical decision making about cardiac imaging as implemented in the NICE clinical guideline for patients has relevant limitations. KEY POINTS: • Duke clinical score is not implemented correctly in NICE guideline 95. • Pretest probability assessment in NICE guideline 95 is impossible for most patients. • Improved clinical decision making requires accurate pretest probability calculation. • These refinements are essential for appropriate use of cardiac CT.


Assuntos
Técnicas de Imagem Cardíaca , Dor no Peito/diagnóstico por imagem , Tomada de Decisão Clínica , Fidelidade a Diretrizes , Guias de Prática Clínica como Assunto , Tomografia Computadorizada por Raios X , Adulto , Idoso , Dor no Peito/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade , Fatores de Risco
15.
J Am Coll Cardiol ; 70(1): 42-55, 2017 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-28662806

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. OBJECTIVES: The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. METHODS: TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry, which captured all TAVRs performed from January 2010 to January 2012 across 34 centers. RESULTS: A total of 12,804 patients from FRANCE TAVI and 4,165 patients from FRANCE 2 were included in this analysis. The median age of patients was 84.6 years, and 49.7% were men. FRANCE TAVI participants were older but at lower surgical risk (median logistic European System for Cardiac Operative Risk Evaluation [EuroSCORE]: 15.0% vs. 18.4%; p < 0.001). More than 80% of patients in FRANCE TAVI underwent transfemoral TAVR. Transesophageal echocardiography guidance decreased from 60.7% to 32.3% of cases, whereas more recent procedures were increasingly performed in hybrid operating rooms (15.8% vs. 35.7%). Rates of Valve Academic Research Consortium-defined device success increased from 95.3% in FRANCE 2 to 96.8% in FRANCE TAVI (p < 0.001). In-hospital and 30-day mortality rates were 4.4% and 5.4%, respectively, in FRANCE TAVI compared with 8.2% and 10.1%, respectively, in FRANCE 2 (p < 0.001 for both). Stroke and potentially life-threatening complications, such as annulus rupture or aortic dissection, remained stable over time, whereas rates of cardiac tamponade and pacemaker implantation significantly increased. CONCLUSIONS: The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all-comers population on a national scale. Nonetheless, given that TAVR indications are likely to expand to patients at lower surgical risk, concerns remain regarding potentially life-threatening complications and pacemaker implantation. (Registry of Aortic Valve Bioprostheses Established by Catheter [FRANCE TAVI]; NCT01777828).


Assuntos
Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/tendências , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo
16.
JACC Cardiovasc Interv ; 9(20): 2113-2120, 2016 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-27765304

RESUMO

OBJECTIVES: The study sought to assess the safety and efficacy of a minimally invasive strategy (MIS) (local anesthesia and conscious sedation) compared to general anesthesia (GA) among the largest published cohort of patients undergoing transcarotid transcatheter aortic valve replacement (TAVR). BACKGROUND: Transcarotid TAVR has been shown to be feasible and safe. There is, however, no information pertaining to the mode anesthesia in these procedures. METHODS: Between 2009 and 2014, 174 patients underwent transcarotid TAVR at 2 French centers. All patients were unsuitable for transfemoral TAVR due to severe peripheral vascular disease. An MIS was undertaken in 29.8% (n = 52) and GA in 70.1% (n = 122). One-year clinical outcomes were available in all patients and were described according to the Valve Academic Research Consortium-2 consensus. RESULTS: Transcarotid vascular access and transcatheter valve deployment was successful in all cases. Thirty-day mortality was 7.4% (n = 13) and 1-year all-cause and cardiovascular mortality were 12.6% (n = 22) and 8.0% (n = 14), respectively. According to the type of anesthesia, there was no between group difference in 30-day mortality (GA 7.3% vs. MIS 7.6%; p = 0.94), 1-year mortality (GA 13.9% vs. MIS 9.6%; p = 0.43), 1-month clinical efficacy (GA 85.2% vs. MIS 94.2%; p = 0.09), and early safety (GA 77.8% vs. MIS 86.5%; p = 0.18). There were 10 (5.7%) periprocedural cerebrovascular events: 4 strokes (2.2%) and 6 transient ischemic attacks (3.4%) among those treated with GA. There was neither stroke nor transient ischemic attack in the MIS group (p < 0.001). CONCLUSIONS: The transcarotid approach for TAVR is feasible using general or local anesthesia. A higher rate of perioperative strokes was observed with GA.


Assuntos
Anestesia Geral , Anestesia Local , Valva Aórtica/cirurgia , Artéria Carótida Primitiva , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/efeitos adversos , Anestesia Geral/mortalidade , Anestesia Local/efeitos adversos , Anestesia Local/mortalidade , Bases de Dados Factuais , Feminino , França , Humanos , Ataque Isquêmico Transitório/etiologia , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
17.
J Am Coll Cardiol ; 68(15): 1637-1647, 2016 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-27712776

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has revolutionized management of high-risk patients with severe aortic stenosis. However, survival and the incidence of severe complications have been assessed in relatively small populations and/or with limited follow-up. OBJECTIVES: This report details late clinical outcome and its determinants in the FRANCE-2 (FRench Aortic National CoreValve and Edwards) registry. METHODS: The FRANCE-2 registry prospectively included all TAVRs performed in France. Follow-up was scheduled at 30 days, at 6 months, and annually from 1 to 5 years. Standardized VARC (Valve Academic Research Consortium) outcome definitions were used. RESULTS: A total of 4,201 patients were enrolled between January 2010 and January 2012 in 34 centers. Approaches were transarterial (transfemoral 73%, transapical 18%, subclavian 6%, and transaortic or transcarotid 3%) or, in 18% of patients, transapical. Median follow-up was 3.8 years. Vital status was available for 97.2% of patients at 3 years. The 3-year all-cause mortality was 42.0% and cardiovascular mortality was 17.5%. In a multivariate model, predictors of 3-year all-cause mortality were male sex (p < 0.001), low body mass index, (p < 0.001), atrial fibrillation (p < 0.001), dialysis (p < 0.001), New York Heart Association functional class III or IV (p < 0.001), higher logistic EuroSCORE (p < 0.001), transapical or subclavian approach (p < 0.001 for both vs. transfemoral approach), need for permanent pacemaker implantation (p = 0.02), and post-implant periprosthetic aortic regurgitation grade ≥2 of 4 (p < 0.001). Severe events according to VARC criteria occurred mainly during the first month and subsequently in <2% of patients/year. Mean gradient, valve area, and residual aortic regurgitation were stable during follow-up. CONCLUSIONS: The FRANCE-2 registry represents the largest database available on late results of TAVR. Late mortality is largely related to noncardiac causes. Incidence rates of severe events are low after the first month. Valve performance remains stable over time.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Feminino , França , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Curr Pharm Des ; 22(13): 1888-95, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26898915

RESUMO

Transcatheter aortic valve implantation (TAVI) is all the more used therapeutic option for patients suffering from symptomatic severe aortic valvular stenosis declined by surgeons because of high surgical risk. Given the high bleeding and ischemic risk of this vulnerable population, their antithrombotic treatment becomes a crucial issue. There is no consensus on antithrombotic treatment after TAVI and dual antiplatelet therapy (DAPT) with aspirin (indefinitely) and clopidogrel (1-6 months) is, in general, recommended. With regards to patients with an indication for oral anticoagulation (OAC), a combination of OAC plus aspirin or clopidogrel is commonly suggested. This review underscores that it is extremely difficult to compare different antithrombotic regimens in patients undergoing TAVI because of their variable demographic characteristics. Nevertheless, available data suggest that DAPT results to more bleeding events. Still, whether it positively affects ischemic episodes is doubtful. Ongoing trials are expected to draw a clearer picture on the field.


Assuntos
Estenose da Valva Aórtica/cirurgia , Inibidores da Agregação Plaquetária/uso terapêutico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Administração Oral , Anticoagulantes/administração & dosagem , Anticoagulantes/uso terapêutico , Aspirina/uso terapêutico , Clopidogrel , Quimioterapia Combinada , Humanos , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico
19.
Curr Pharm Des ; 22(13): 1896-903, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26642773

RESUMO

INTRODUCTION: Aortic stenosis is one of the most frequent valvulopathy of modern time necessitating interventional therapy when symptoms arise and stenosis becomes severe. First line treatment has traditionally been surgical aortic valve replacement (SAVR). However in the last decade transcatheter aortic valve implantation (TAVI) with bioprosthetic valves has proved to be a sound solution for high-risk for SAVR or inoperable patients. As expected implantation of the bioprosthetic device requires administration of antiplatelet regimen to the patients for a certain period. Atrial fibrillation (AF) may occur frequently during the peri-procedural period. In this background, the occurrence of AF after device implantation may be a challenging issue. METHODS: We performed a literature search of PubMed and Embase database. Published articles reporting the incidence, clinical implications and description of antithrombotic regimen of New-onset atrial fibrillation (NOAF) in individuals undergoing TAVI were considered eligible. Incidence, Implications and Antithrombotic Regimen: The overall occurrence of NOAF is reported to be 1%-32% after TAVI. Left atrial enlargement and transapical approach constitute independent predictors for NOAF. Additionally it has been shown that patients with AF face an increased risk of death irrespective of the type of AF. Patients, with a history of AF, present greater rate of death than individuals with NOAF. NOAF is responsible for cerebrovascular events (CVE) occurring in the subacute phase (days 1-30) after the procedure. The risk of stroke/transient ischemic attack after TAVI is increased at least two fold by the presence of atrial fibrillation. Empirically, a dual antiplatelet strategy has been used for patients undergoing TAVR, including aspirin and a thienopyridine. In cases where patients are in need of oral anticoagulation after TAVI a combination of aspirin or thienopyridine with acenocoumarol has been the preferred regimen. DISCUSSION: Despite the continuously crescent use of TAVI for patients with symptomatic severe aortic stenosis, there are still many aspects of this procedure to be clarified. A lack of data exists from the available clinical trials regarding the appropriate anticoagulation therapy for patients with greater risk for thromboembolic events. As a result, patient's treatment remains at the discretion of the physician. CONCLUSION: Limited data are available regarding the optimal therapeutic regimen in patients undergoing TAVI who need therapy for AF. Carefully designed clinical studies might further clarify the incidence and interrelation between atrial fibrillation and TAVI. The balance between the efficacy and risk of anticoagulation needs to be further clarified in patients undergoing TAVI.


Assuntos
Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA