Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39134375

RESUMO

BACKGROUND AND PURPOSE: Early opacification of the renal collecting system during CT myelography (CTM) performed for the evaluation of Spontaneous Intracranial Hypotension (SIH) has been demonstrated in prior studies. However, these investigations often included CTMs scanned >30 minutes after intrathecal contrast injection, a longer delay than the myelographic techniques used in current practice. The purpose of this study was to determine whether renal contrast excretion (RCE) measured during this earlier time period (≤30 minutes) can discriminate patients with SIH from patients without SIH. MATERIALS AND METHODS: Single-center, retrospective cohort of consecutive patients presenting for evaluation of possible SIH between July 2021-May 2022. RCE was measured in both renal hila using standardized (5-15mm3) ROIs. ROC curves were constructed comparing RCE between patients with SIH to patients without SIH in the overall cohort, and within the subgroup of patients with negative myelograms. RESULTS: The study cohort included 190 subjects. Both unadjusted and adjusted models demonstrated a statistically significant increase in renal contrast density among patients with SIH compared to those without SIH (p-values ≤ 0.001). The ROC curve showed moderate discrimination between these groups (AUC 0.76). However, using clinically meaningful test criteria of sensitivity >90% or specificity >90%, the two corresponding threshold HU values resulted in low specificity of 31.3% and sensitivity of 50.8%. Subgroup analysis of patients with negative myelograms showed poorer performance in discriminating SIH+ from SIH- (AUC 0.62). In this subgroup, using similar test criteria of sensitivity >90% or specificity >90 resulted in low specificities and sensitivities, at 26.0% and 37.5% respectively. CONCLUSIONS: We found a statistically significant positive association between RCE and SIH diagnosis during early-phase CTM, however clinically useful thresholds based on cutoff values for renal HU resulted in poor sensitivities or specificities, with substantial false positives or false negatives, respectively. Thus, while we confirmed statistically significant differences in RCE in the ≤30 min time period, in keeping with prior investigations of more delayed time periods, overlap in renal attenuation values prevented the development of clinically useful threshold value for discriminating SIH+ from SIH-patients. ABBREVIATIONS: SIH = spontaneous intracranial hypotension; RCE = renal contrast excretion; CTM = CT myelography; CVF = CSF-venous fistula; ICHD-3 = international classification of headache disorders third edition; CKD = chronic kidney disease.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38719613

RESUMO

BACKGROUND AND PURPOSE: Various imaging techniques have been described to detect CSF-venous fistulas in the setting of spontaneous intracranial hypotension, including decubitus CT myelography. The expected diagnostic yield of decubitus CT myelography for CSF-venous fistula detection is not fully established. The purpose of this study was to assess the yield of decubitus CT myelography among consecutive patients presenting for evaluation of possible spontaneous intracranial hypotension and to examine the impact of brain MR imaging findings of spontaneous intracranial hypotension on the diagnostic yield. MATERIALS AND METHODS: The study included a single-center, retrospective cohort of consecutive patients presenting during a 1-year period who underwent CT myelography and had no CSF identified in the epidural space. Patients with epidural CSF leaks were included in a secondary cohort. Subjects were grouped according to positioning for the myelogram, either decubitus or prone, and the presence of imaging findings of spontaneous intracranial hypotension on preprocedural brain MR imaging. Diagnostic yields for each subgroup were calculated, and the yield of decubitus CT myelography was compared with that of prone CT myelography. RESULTS: The study cohort comprised 302 subjects, including 247 patients with no epidural fluid. The diagnostic yield of decubitus CT myelography for CSF-venous fistula detection among subjects with positive brain MR imaging findings and no epidural fluid was 73%. No CSF-venous fistulas were identified among subjects with negative findings on brain imaging. Among subjects with an epidural leak, brain MR imaging was negative for signs of spontaneous intracranial hypotension in 22%. Prone CT myelography identified a CSF-venous fistula less commonly than decubitus CT myelography (43% versus 73%, P = .19), though the difference was not statistically significant in this small subgroup. CONCLUSIONS: We found the diagnostic yield of decubitus CT myelography to be similar to the yield previously reported for digital subtraction myelography among patients with positive findings on brain imaging. No CSF-venous fistulas were identified in patients with negative findings on brain imaging; epidural CSF leaks accounted for all cases of patients who had spontaneous intracranial hypotension with negative brain imaging findings. This study provides useful data for counseling patients and helps establish a general benchmark for the decubitus CT myelography yield for CSF-venous fistula detection.

3.
Int J Comput Assist Radiol Surg ; 14(3): 525-535, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29934792

RESUMO

PURPOSE: Augmented reality has potential to enhance surgical navigation and visualization. We determined whether head-mounted display augmented reality (HMD-AR) with superimposed computed tomography (CT) data could allow the wearer to percutaneously guide pedicle screw placement in an opaque lumbar model with no real-time fluoroscopic guidance. METHODS: CT imaging was obtained of a phantom composed of L1-L3 Sawbones vertebrae in opaque silicone. Preprocedural planning was performed by creating virtual trajectories of appropriate angle and depth for ideal approach into the pedicle, and these data were integrated into the Microsoft HoloLens using the Novarad OpenSight application allowing the user to view the virtual trajectory guides and CT images superimposed on the phantom in two and three dimensions. Spinal needles were inserted following the virtual trajectories to the point of contact with bone. Repeat CT revealed actual needle trajectory, allowing comparison with the ideal preprocedural paths. RESULTS: Registration of AR to phantom showed a roughly circular deviation with maximum average radius of 2.5 mm. Users took an average of 200 s to place a needle. Extrapolation of needle trajectory into the pedicle showed that of 36 needles placed, 35 (97%) would have remained within the pedicles. Needles placed approximated a mean distance of 4.69 mm in the mediolateral direction and 4.48 mm in the craniocaudal direction from pedicle bone edge. CONCLUSION: To our knowledge, this is the first peer-reviewed report and evaluation of HMD-AR with superimposed 3D guidance utilizing CT for spinal pedicle guide placement for the purpose of cannulation without the use of fluoroscopy.


Assuntos
Vértebras Lombares/cirurgia , Parafusos Pediculares , Cirurgia Assistida por Computador/métodos , Realidade Virtual , Fluoroscopia , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Fusão Vertebral , Tomografia Computadorizada por Raios X
4.
J Comput Assist Tomogr ; 41(2): 302-308, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27753722

RESUMO

OBJECTIVE: We correlate and evaluate the accuracy of accepted anthropometric methods of percent body fat (%BF) quantification, namely, hydrostatic weighing (HW) and air displacement plethysmography (ADP), to 2 automatic adipose tissue quantification methods using computed tomography (CT). METHODS: Twenty volunteer subjects (14 men, 6 women) received head-to-toe CT scans. Hydrostatic weighing and ADP were obtained from 17 and 12 subjects, respectively. The CT data underwent conversion using 2 separate algorithms, namely, the Schneider method and the Beam method, to convert Hounsfield units to their respective tissue densities. The overall mass and %BF of both methods were compared with HW and ADP. RESULTS: When comparing ADP to CT data using the Schneider method and Beam method, correlations were r = 0.9806 and 0.9804, respectively. Paired t tests indicated there were no statistically significant biases. Additionally, observed average differences in %BF between ADP and the Schneider method and the Beam method were 0.38% and 0.77%, respectively. The %BF measured from ADP, the Schneider method, and the Beam method all had significantly higher mean differences when compared with HW (3.05%, 2.32%, and 1.94%, respectively). CONCLUSIONS: We have shown that total body mass correlates remarkably well with both the Schneider method and Beam method of mass quantification. Furthermore, %BF calculated with the Schneider method and Beam method CT algorithms correlates remarkably well with ADP. The application of these CT algorithms have utility in further research to accurately stratify risk factors with periorgan, visceral, and subcutaneous types of adipose tissue, and has the potential for significant clinical application.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Peso Corporal/fisiologia , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adulto , Composição Corporal/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pletismografia/métodos , Reprodutibilidade dos Testes
5.
BMC Obes ; 2: 10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26217525

RESUMO

BACKGROUND: Central adipose tissue is appreciated as a risk factor for cardiometabolic disorders. The purpose of this study was to determine the efficacy of a volumetric 3D analysis of central adipose tissue in predicting disease. Full body computerized tomography (CT) scans were obtained from 1225 female (518) and male (707) subjects, aged 18-88. Percent central body fat (%cBF) was determined by quantifying the adipose tissue volume from the dome of the liver to the pubic symphysis. Calcium score was determined from the calcium content of coronary arteries. Relationships between %cBF, BMI, and several cardiometabolic disorders were assessed controlling for age, sex, and race. RESULTS: Higher %cBF was significantly greater for those with type 2 diabetes and hypertension, but not stroke or hypercholesterolemia. Simple anthropometric determination of BMI equally correlated with diabetes and hypertension as central body fat. Calcium scoring significantly correlated with all measurements of cardiovascular health, including hypertension, hypercholesterolemia, and heart disease. CONCLUSIONS: Central body fat and BMI equally and highly predict incidence of hypertension and type 2 diabetes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA