Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Neuroeng Rehabil ; 21(1): 4, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172975

RESUMO

BACKGROUND: Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. METHODS: A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. RESULTS: Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. CONCLUSIONS: This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics.


Assuntos
Terapia por Estimulação Elétrica , Músculo Esquelético , Humanos , Eletromiografia , Eletrodos Implantados , Músculo Esquelético/fisiologia , Extremidade Inferior , Tecnologia sem Fio
3.
J Neuroeng Rehabil ; 20(1): 138, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37848992

RESUMO

OBJECTIVE: We aim to determine a comprehensive set of requirements, perceptions, and expectations that people with spinal cord injury (SCI) and the clinicians in charge of their rehabilitation have regarding the use of wearable robots (WR) for gait rehabilitation. BACKGROUND: There are concerns due to the limited user acceptance of WR for gait rehabilitation. Developers need to emphasize understanding the needs and constraints of all stakeholders involved, including the real-life dynamics of rehabilitation centers. METHODS: 15 people with SCI, 9 without experience with WR and 6 with experience with these technologies, and 10 clinicians from 3 rehabilitation centers in Spain were interviewed. A directed content analysis approach was used. RESULTS: 78 codes grouped into 9 categories (physical results, usability, psychology-related codes, technical characteristics, activities, acquisition issues, context of use, development of the technologies and clinical rehabilitation context) were expressed by at least 20% of the users interviewed, of whom 16 were not found in the literature. The agreement percentage between each group and subgroup included in the study, calculated as the number of codes that more than 20% of both groups expressed, divided over the total amount of codes any of those two groups agreed on (≥ 20%), showed limited agreement between patients and clinicians (50.00%) and between both types of patients (55.77%). The limited accessibility and availability of lower limb exoskeletons for gait rehabilitation arose in most of the interviews. CONCLUSIONS: The limited agreement percentage between patients and clinicians indicates that including both types of users in the design process of these technologies is important, given that their requirements are complementary. Engaging users with prior technology experience is recommended, as they often exhibit strong internal consensus and articulate well-defined requirements. This study adds up the knowledge available in the literature and the new codes found in our data, which enlighten important aspects that ought to be addressed in the field to develop technologies that respond to users' needs, are usable and feasible to implement in their intended contexts. APPLICATION: The set of criteria summarized in our study will be useful to guide the design, development, and evaluation of WR for gait rehabilitation to meet user's needs and allow them to be implemented in their intended context of use.


Assuntos
Exoesqueleto Energizado , Traumatismos da Medula Espinal , Dispositivos Eletrônicos Vestíveis , Humanos , Traumatismos da Medula Espinal/reabilitação , Marcha , Extremidade Inferior
4.
Neurorehabil Neural Repair ; 37(10): 705-715, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37864467

RESUMO

BACKGROUND: The Gait Deviation Index for Spinal Cord Injury (SCI-GDI) was recently proposed as a dimensionless multivariate kinematic measure based on 21 gait features derived from 3-dimensional kinematic data which quantifies gait impairment of adult population with incomplete spinal cord injury (iSCI) relative to the normative gait of a healthy group. Nevertheless, no validity studies of the SCI-GDI have been published to date. OBJECTIVE: To assess the construct validity of the SCI-GDI in adult population following iSCI. Methods. SCI-GDI data were obtained from a sample of 50 healthy volunteers and 35 adults with iSCI. iSCI group was also assessed with the following measures: 10-Meter Walk Test (10MWT) at both self-selected (SS) and maximum speeds, Timed Up and Go Test (TUGT), SS and maximum levels of the Walking Index for Spinal Cord Injury (WISCI) II, mobility items of the Spinal Cord Independence Measure III (SCIM IIIIOMob), Lower Extremity Motor Score (LEMS), and Modified Ashworth Scale (MAS). Spearman's correlation coefficient was used to investigate the relationship with the SCI-GDI. RESULTS: SCI-GDI shows strong correlation with the 10MWT (r ≥ -.716) and good correlation with LEMS (r = .638), TUGT (r = -.582), SS WISCI II levels (r = .521), and SCIM IIIIOMob (r = .501). No significant correlations were found with maximum WISCI II levels and MAS (P > .006). CONCLUSIONS: Construct validity of the SCI-GDI was demonstrated with the 10MWT, TUGT, LEMS, SCIM IIIIOMob, and SS WISCI II levels for independently walking adults with iSCI. Future work will include assessing the psychometric characteristics with a more heterogeneous sample, also considering the pediatric population.


Assuntos
Transtornos dos Movimentos , Traumatismos da Medula Espinal , Adulto , Humanos , Criança , Equilíbrio Postural , Estudos de Tempo e Movimento , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/diagnóstico , Marcha , Caminhada
5.
Spinal Cord ; 61(7): 391-398, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37248356

RESUMO

STUDY DESIGN: Descriptive study with cross-sectional data collection. OBJECTIVES: To analyse and compare the 3D kinematics and kinetics of thorax, elbow and wrist, and the spatio-temporal parameters during swing-through gait (SG) and reciprocal gait (RG). SETTING: Hospital Nacional de Parapléjicos in Toledo, Spain. METHODS: An instrumented biomechanical analysis of the upper body of 15 adults with an incomplete lumbar or thoracic spinal cord injury was performed using a marker motion capture system and load cell crutches. Five walks of each gait pattern were analysed. RESULTS: The elbow was in flexion, valgus and pronation and the wrist was in extension and ulnar deviation in both SG and RG. Their kinematic patterns were quite similar, except in elbow valgus and wrist extension in which statistically significant differences were observed. In the thorax prevailed flexion movement in SG and rotation movement in RG. The reaction forces in the elbow and the wrist were notably higher in SG than in RG, but the joint moments were similar in both gait patterns. CONCLUSIONS: SG showed greater demands and RG showed higher requirements on trunk motor control. In addition, SG could increase the probability of back and neck pain. Therefore RG should be recommended, whenever possible, in incomplete spinal cord injured people. Rehabilitative management should consider adapting properly the crutch height and the inclination cane, loading the minimum weight on the crutches, using cushioning devices, reducing the duration of support phase, and limiting the overall use time of the crutches.


Assuntos
Cotovelo , Traumatismos da Medula Espinal , Adulto , Humanos , Traumatismos da Medula Espinal/complicações , Muletas , Punho , Fenômenos Biomecânicos , Cinética , Estudos Transversais , Marcha
6.
iScience ; 26(5): 106675, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37250318

RESUMO

This study explores the use of a brain-computer interface (BCI) based on motor imagery (MI) for the control of a lower limb exoskeleton to aid in motor recovery after a neural injury. The BCI was evaluated in ten able-bodied subjects and two patients with spinal cord injuries. Five able-bodied subjects underwent a virtual reality (VR) training session to accelerate training with the BCI. Results from this group were compared with a control group of five able-bodied subjects, and it was found that the employment of shorter training by VR did not reduce the effectiveness of the BCI and even improved it in some cases. Patients gave positive feedback about the system and were able to handle experimental sessions without reaching high levels of physical and mental exertion. These results are promising for the inclusion of BCI in rehabilitation programs, and future research should investigate the potential of the MI-based BCI system.

7.
Front Neurosci ; 17: 1154480, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36998726

RESUMO

Introduction: Brain-machine interfaces (BMIs) attempt to establish communication between the user and the device to be controlled. BMIs have great challenges to face in order to design a robust control in the real field of application. The artifacts, high volume of training data, and non-stationarity of the signal of EEG-based interfaces are challenges that classical processing techniques do not solve, showing certain shortcomings in the real-time domain. Recent advances in deep-learning techniques open a window of opportunity to solve some of these problems. In this work, an interface able to detect the evoked potential that occurs when a person intends to stop due to the appearance of an unexpected obstacle has been developed. Material and methods: First, the interface was tested on a treadmill with five subjects, in which the user stopped when an obstacle appeared (simulated by a laser). The analysis is based on two consecutive convolutional networks: the first one to discern the intention to stop against normal walking and the second one to correct false detections of the previous one. Results and discussion: The results were superior when using the methodology of the two consecutive networks vs. only the first one in a cross-validation pseudo-online analysis. The false positives per min (FP/min) decreased from 31.8 to 3.9 FP/min and the number of repetitions in which there were no false positives and true positives (TP) improved from 34.9% to 60.3% NOFP/TP. This methodology was tested in a closed-loop experiment with an exoskeleton, in which the brain-machine interface (BMI) detected an obstacle and sent the command to the exoskeleton to stop. This methodology was tested with three healthy subjects, and the online results were 3.8 FP/min and 49.3% NOFP/TP. To make this model feasible for non-able bodied patients with a reduced and manageable time frame, transfer-learning techniques were applied and validated in the previous tests, and were then applied to patients. The results for two incomplete Spinal Cord Injury (iSCI) patients were 37.9% NOFP/TP and 7.7 FP/min.

8.
J Neuroeng Rehabil ; 20(1): 36, 2023 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-36964574

RESUMO

BACKGROUND: In recent years, ambulatory lower limb exoskeletons are being gradually introduced into the clinical practice to complement walking rehabilitation programs. However, the clinical evidence of the outcomes attained with these devices is still limited and nonconclusive. Furthermore, the user-to-robot adaptation mechanisms responsible for functional improvement are still not adequately unveiled. This study aimed to (1) assess the safety and feasibility of using the HANK exoskeleton for walking rehabilitation, and (2) investigate the effects on walking function after a training program with it. METHODS: A randomized controlled trial was conducted including a cohort of 23 patients with less than 1 year since injury, neurological level of injury (C2-L4) and severity (American Spinal Cord Injury Association Impairment Scale [AIS] C or D). The intervention was comprised of 15 one-hour gait training sessions with lower limb exoskeleton HANK. Safety was assessed through monitoring of adverse events, and pain and fatigue through a Visual Analogue Scale. LEMS, WISCI-II, and SCIM-III scales were assessed, along with the 10MWT, 6MWT, and the TUG walking tests (see text for acronyms). RESULTS: No major adverse events were reported. Participants in the intervention group (IG) reported 1.8 cm (SD 1.0) for pain and 3.8 (SD 1.7) for fatigue using the VAS. Statistically significant differences were observed for the WISCI-II for both the "group" factor (F = 16.75, p < 0.001) and "group-time" interactions (F = 8.87; p < 0.01). A post-hoc analysis revealed a statistically significant increase of 3.54 points (SD 2.65, p < 0.0001) after intervention for the IG but not in the CG (0.7 points, SD 1.49, p = 0.285). No statistical differences were observed between groups for the remaining variables. CONCLUSIONS: The use of HANK exoskeleton in clinical settings is safe and well-tolerated by the patients. Patients receiving treatment with the exoskeleton improved their walking independence as measured by the WISCI-II after the treatment.


Assuntos
Exoesqueleto Energizado , Traumatismos da Medula Espinal , Humanos , Marcha , Caminhada , Traumatismos da Medula Espinal/reabilitação , Fadiga , Dor
9.
IEEE Trans Biomed Eng ; 70(2): 659-670, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35994554

RESUMO

OBJECTIVE: Wireless power transfer (WPT) is used as an alternative to batteries to accomplish miniaturization in electronic medical implants. However, established WPT methods require bulky parts within the implant or cumbersome external systems, hindering minimally invasive deployments and the development of networks of implants. As an alternative, we propose a WPT approach based on volume conduction of high frequency (HF) current bursts. These currents are applied through external electrodes and are collected by the implants through two electrodes at their opposite ends. This approach avoids bulky components, enabling the development of flexible threadlike implants. METHODS: We study in humans if HF (6.78 MHz) current bursts complying with safety standards and applied through two textile electrodes strapped around a limb can provide substantial powers from pairs of implanted electrodes. RESULTS: Time averaged electric powers obtained from needle electrodes (diameter = 0.4 mm, length = 3 mm, separation = 30 mm) inserted into arms and lower legs of five healthy participants were 5.9 ± 0.7 mW and 2.4 ± 0.3 mW respectively. We also characterize the coupling between the external system and the implants using personalized two-port impedance models generated from medical images. CONCLUSIONS: The results demonstrate that innocuous and imperceptible HF current bursts that flow through the tissues by volume conduction can be used to wirelessly power threadlike implants. SIGNIFICANCE: This is the first time that WPT based on volume conduction is demonstrated in humans. This method overcomes the limitations of existing WPT methods in terms of minimal invasiveness and usability.


Assuntos
Eletrônica Médica , Próteses e Implantes , Humanos , Eletrodos Implantados , Fontes de Energia Elétrica , Miniaturização , Tecnologia sem Fio
10.
Healthcare (Basel) ; 10(12)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36553926

RESUMO

BACKGROUND: The aim of this study was to summarize evidence on energy metabolism through peak fat oxidation (PFO) and maximum fat oxidation (Fatmax), as well as to analyze the protocols used in people with spinal cord injury (SCI) and to examine the main factors related to fat oxidation ability (i.e., age, sex, level of physical activity, and level and degree of injury). METHODS: Studies to determine PFO and Fatmax using indirect calorimetry with an arm exercise protocol for SCI patients were included after a systematic search. Other endpoints included study design, sample size, control group, demographic data, level of injury, physical condition, protocol, outcomes measured, and statistical findings. RESULTS: Eight studies (n = 560) were included. The mean value of VO2peak was 1.86 L∙min-1 (range 0.75-2.60 L∙min-1) (lowest value in the tetraplegic subjects). The PFO ranged between 0.06 and 0.30 g∙min-1 (lowest rates: the non-trained subjects with cervical SCI; highest: the tetraplegic subjects). Two types of exercise protocol were found: arm cycle ergometer, and wheelchair propulsion with a computerized ergometer. Five studies used an incremental protocol (2-3 min/stage, different load increments); the rest performed tests of 20 min/stage at three intensities. CONCLUSION: There are few existing studies measuring fat oxidation in SCI, many of which used small and heterogeneous samples. PFO was lower in SCI subjects when compared with non-injured people performing lower-limb exercise; however, comparing upper-limb exercise, people with SCI showed higher values.

11.
Bioengineering (Basel) ; 9(12)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36550969

RESUMO

(1) Background: Cervical spinal cord injury (SCI) patients have impairment in the autonomic nervous system, reflected in the cardiovascular adaption level during the performance of upper limb (UL) activities carried out in the rehabilitation process. This adaption level could be measured from the heart rate (HR) by means of wearable technologies. Therefore, the objective was to analyze the feasibility of using Xiaomi Mi Band 5 wristband (XMB5) for HR monitoring in these patients during the performance of UL activities; (2) Methods: The HR measurements obtained from XMB5 were compared to those obtained by the professional medical equipment Nonin LifeSense II capnograph and pulse oximeter (NLII) in static and dynamic conditions. Then, four healthy people and four cervical SCI patients performed a UL training based on six experimental sessions; (3) Results: the correlation between the HR measurements from XMB5 and NLII devices was strong and positive in healthy people (r = 0.921 and r = 0.941 (p < 0.01) in the static and dynamic conditions, respectively). Then, XMB5 was used within the experimental sessions, and the HR oscillation range measured was significantly higher in healthy individuals than in patients; (4) Conclusions: The XMB5 seems to be feasible for measuring the HR in this biomedical application in SCI patients.

12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4064-4067, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086336

RESUMO

Spinal Cord Injury (SCI) refers to damage to the spinal cord that can affect different body functionalities. Recovery after SCI depends on multiple factors, being the rehabilitation therapy one of them. New approaches based on robot-assisted training offer the possibility to make training sessions longer and with a reproducible pattern of movements. The control of these robotic devices by means of Brain-Machine Interfaces (BMIs) based on Motor Imagery (MI) favors the patient cognitive engagement during the rehabilitation, promoting mechanisms of neuroplasticity. This research evaluates the acceptance and feedback received from patients with incomplete SCI about the usage of a MI-based BMI with a lower-limb exoskeleton. Clinical Relevance- Patients experienced satisfaction when using the exoskeleton and levels of mental and physical workload were withing reasonable limits. In addition results from the BMI were promising for the inclusion of this type of systems in rehabilitation programs.


Assuntos
Interfaces Cérebro-Computador , Exoesqueleto Energizado , Traumatismos da Medula Espinal , Índice de Massa Corporal , Humanos , Extremidade Inferior , Traumatismos da Medula Espinal/reabilitação
13.
Front Bioeng Biotechnol ; 10: 874074, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35875486

RESUMO

The Gait Deviation Index (GDI) is a dimensionless multivariate measure of overall gait pathology represented as a single score that indicates the gait deviation from a normal gait average. It is calculated using kinematic data recorded during a three-dimensional gait analysis and an orthonormal vectorial basis with 15 gait features that was originally obtained using singular value decomposition and feature analysis on a dataset of children with cerebral palsy. Ever since, it has been used as an outcome measure to study gait in several conditions, including spinal cord injury (SCI). Nevertheless, the validity of implementing the GDI in a population with SCI has not been studied yet. We investigate the application of these mathematical methods to derive a similar metric but with a dataset of adults with SCI (SCI-GDI). The new SCI-GDI is compared with the original GDI to evaluate their differences and assess the need for a specific GDI for SCI and with the WISCI II to evaluate its sensibility. Our findings show that a 21-feature basis is necessary to account for most of the variance in gait patterns in the SCI population and to provide high-quality reconstructions of the gait curves included in the dataset and in foreign data. Furthermore, using only the first 15 features of our SCI basis, the fidelity of the reconstructions obtained in our population is higher than that when using the basis of the original GDI. The results showed that the SCI-GDI discriminates most levels of the WISCI II scale, except for levels 12 and 18. Statistically significant differences were found between both indexes within each WISCI II level except for 12, 20, and the control group (p < 0.05). In all levels, the average GDI value was greater than the average SCI-GDI value, but the difference between both indexes is larger in data with greater impairment and it reduces progressively toward a normal gait pattern. In conclusion, the implementation of the original GDI in SCI may lead to overestimation of gait function, and our new SCI-GDI is more sensitive to larger gait impairment than the GDI. Further validation of the SCI-GDI with other scales validated in SCI is needed.

14.
Front Hum Neurosci ; 16: 826333, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35444522

RESUMO

The Gait Deviation Index (GDI) is a multivariate measure of overall gait pathology based on 15 gait features derived from three-dimensional (3D) kinematic data. GDI aims at providing a comprehensive, easy to interpret, and clinically meaningful metric of overall gait function. It has been used as an outcome measure to study gait in several conditions: cerebral palsy (CP), post-stroke hemiparetic gait, Duchenne muscular dystrophy, and Parkinson's disease, among others. Nevertheless, its use in population with Spinal Cord Injury (SCI) has not been studied yet. The aim of the present study was to investigate the applicability of the GDI to SCI through the assessment of the relationship of the GDI with the Walking Index for Spinal Cord Injury (WISCI) II. 3D gait kinematics of 34 patients with incomplete SCI (iSCI) was obtained. Besides, 3D gait kinematics of a sample of 50 healthy volunteers (HV) was also gathered with Codamotion motion capture system. A total of 302 (iSCI) and 446 (HV) strides were collected. GDI was calculated for each stride and grouped for each WISCI II level. HV data were analyzed as an additional set. Normal distribution for each group was assessed with Kolmogorov-Smirnov tests. Afterward, ANOVA tests were performed between each pair of WISCI II levels to identify differences among groups (p < 0.05). The results showed that the GDI was normally distributed across all WISCI II levels in both iSCI and HV groups. Furthermore, our results showed an increasing relationship between the GDI values and WISCI II levels in subjects with iSCI, but only discriminative in WISCI II levels 13, 19, and 20. The index successfully distinguished HV group from all the individuals with iSCI. Findings of this study indicated that the GDI is not an appropriate multivariate walking metric to represent the deviation of gait pattern in adult population with iSCI from a normal gait profile when it is compared with the levels of walking impairment described by the WISCI II. Future work should aim at defining and validating an overall gait index derived from 3D kinematic gait variables appropriate for SCI, additionally taking into account other walking ability outcome measures.

15.
IEEE Trans Biomed Eng ; 69(1): 63-74, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34097604

RESUMO

OBJECTIVE: Surface EMG-driven modelling has been proposed as a means to control assistive devices by estimating joint torques. Implanted EMG sensors have several advantages over wearable sensors but provide a more localized information on muscle activity, which may impact torque estimates. Here, we tested and compared the use of surface and intramuscular EMG measurements for the estimation of required assistive joint torques using EMG driven modelling. METHODS: Four healthy subjects and three incomplete spinal cord injury (SCI) patients performed walking trials at varying speeds. Motion capture marker trajectories, surface and intramuscular EMG, and ground reaction forces were measured concurrently. Subject-specific musculoskeletal models were developed for all subjects, and inverse dynamics analysis was performed for all individual trials. EMG-driven modelling based joint torque estimates were obtained from surface and intramuscular EMG. RESULTS: The correlation between the experimental and predicted joint torques was similar when using intramuscular or surface EMG as input to the EMG-driven modelling estimator in both healthy individuals and patients. CONCLUSION: We have provided the first comparison of non-invasive and implanted EMG sensors as input signals for torque estimates in healthy individuals and SCI patients. SIGNIFICANCE: Implanted EMG sensors have the potential to be used as a reliable input for assistive exoskeleton joint torque actuation.


Assuntos
Traumatismos da Medula Espinal , Caminhada , Eletromiografia , Humanos , Músculo Esquelético , Músculos , Traumatismos da Medula Espinal/diagnóstico , Torque
16.
Int J Sport Nutr Exerc Metab ; 32(1): 30-40, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34591786

RESUMO

People with spinal cord injury (SCI) tend to be more sedentary and increase fat accumulation, which could have a negative influence on metabolic flexibility. The aim of this study was to investigate the capacity to oxidize fat in a homogenous sample of men with thoracic SCI compared with healthy noninjured men during an arm cycling incremental test. Forty-one men, 21 with SCI and 20 noninjured controls, performed an incremental arm cycling test to determine peak fat oxidation (PFO) and the intensity of exercise that elicits PFO (Fatmax). PFO was expressed in absolute values (g/min) and relative to whole-body and upper-body lean mass ([mg·min-1]·kg-1) through three different models (adjusting by cardiorespiratory fitness and fat mass). Gross mechanical efficiency was also calculated. PFO was higher in SCI than in noninjured men (0.27 ± 0.07 vs. 0.17 ± 0.07 g/min; 5.39 ± 1.30 vs. 3.29 ± 1.31 [mg·min-1]·kg-1 whole-body lean mass; 8.28 ± 2.11 vs. 5.08 ± 2.12 [mg·min-1]·kg-1 upper-body lean mass). Fatmax was found at a significantly higher percentage of VO2peak in men with SCI (33.6% ± 8.2% vs. 23.6% ± 6.4%). Differences persisted and even increased in the fully adjustment model and at any intensity. Men with SCI showed significantly higher gross mechanical efficiency at 35 and 65 W than the noninjured group. Men with SCI showed higher fat oxidation when compared with noninjured men at any intensity, even increased after full adjustment for lean mass, fat mass, and cardiorespiratory fitness. These findings suggest that SCI men could improve their metabolic flexibility and muscle mass for greater efficiency, not being affected by their fat accumulation.


Assuntos
Aptidão Cardiorrespiratória , Traumatismos da Medula Espinal , Adulto , Braço , Teste de Esforço , Terapia por Exercício , Humanos , Masculino , Consumo de Oxigênio
17.
Eur J Neurosci ; 54(7): 6575-6586, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34494329

RESUMO

The posterior root muscle response (PRM) is a monosynaptic reflex that is evoked by single pulse transcutaneous spinal cord stimulation (tSCS). The main aim of this work was to analyse how body weight loading influences PRM reflex threshold measured from several lower limb muscles in healthy participants. PRM reflex responses were evoked with 1-ms rectangular monophasic pulses applied at an interval of 6 s via a self-adhesive electrode (9 × 5 cm) at the T11-T12 vertebral level. Surface electromyographic activity of lower limb muscles was recorded during four different conditions, one in decubitus supine (DS) and the other three involving standing at 100%, 50%, and 0% body weight loading (BW). PRM threshold intensity, peak-to-peak amplitude, and latency for each muscle were analysed in different conditions study. PRM reflex threshold increased with body weight unloading compared with DS, and the largest change was observed between DS and 0% BW for the proximal muscles and between DS and 50% BW for distal muscles. Peak-to-peak amplitude analysis showed only a significant mean decrease of 34.6% (SD 10.4, p = 0.028) in TA and 53.6% (SD 15.1, p = 0.019) in GM muscles between DS and 50% BW. No significant differences were observed for PRM latency. This study has shown that sensorimotor networks can be activated with tSCS in various conditions of body weight unloading. Higher stimulus intensities are necessary to evoke reflex response during standing at 50% body weight loading. These results have practical implications for gait rehabilitation training programmes that include body weight support.


Assuntos
Músculo Esquelético , Estimulação da Medula Espinal , Peso Corporal , Estimulação Elétrica , Eletromiografia , Humanos , Postura , Reflexo , Medula Espinal
18.
J Neuroeng Rehabil ; 18(1): 148, 2021 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-34565399

RESUMO

BACKGROUND: Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation method able to modulate neuronal activity after stroke. The aim of this systematic review was to determine if tDCS combined with robotic therapy (RT) improves limb function after stroke when compared to RT alone. METHODS: A search for randomized controlled trials (RCTs) published prior to July 15, 2021 was performed. The main outcome was function assessed with the Fugl-Meyer motor assessment for upper extremities (FM/ue) and 10-m walking test (10MWT) for the lower limbs. As secondary outcomes, strength was assessed with the Motricity Index (MI) or Medical Research Council scale (MRC), spasticity with the modified Ashworth scale (MAS), functional independence with the Barthel Index (BI), and kinematic parameters. RESULTS: Ten studies were included for analysis (n = 368 enrolled participants). The results showed a non-significant effect for tDCS combined with RT to improve upper limb function [standardized mean difference (SMD) = - 0.12; 95% confidence interval (CI): - 0.35-0.11)]. However, a positive effect of the combined therapy was observed in the lower limb function (SMD = 0.48; 95% CI: - 0.15-1.12). Significant results favouring tDCS combined with RT were not found in strength (SMD = - 0.15; 95% CI: - 0.4-0.1), spasticity [mean difference (MD) = - 0.15; 95% CI: - 0.8-0.5)], functional independence (MD = 2.5; 95% CI: - 1.9-6.9) or velocity of movement (SMD = 0.06; 95% CI: - 0.3-0.5) with a "moderate" or "low" recommendation level according to the GRADE guidelines. CONCLUSIONS: Current findings suggest that tDCS combined with RT does not improve upper limb function, strength, spasticity, functional independence or velocity of movement after stroke. However, tDCS may enhance the effects of RT alone for lower limb function. tDCS parameters and the stage or type of stroke injury could be crucial factors that determine the effectiveness of this therapy.


Assuntos
Procedimentos Cirúrgicos Robóticos , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Estimulação Transcraniana por Corrente Contínua , Humanos , Extremidade Inferior , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/complicações
19.
Artigo em Inglês | MEDLINE | ID: mdl-34574443

RESUMO

Walking function recovery in spinal cord injury (SCI) is tackled through several therapeutic approaches in which precise evaluation is essential. A systematic review was performed to provide an updated qualitative review of walking ability outcome measures in SCI and to analyze their psychometric properties. PubMed, Cochrane, and PEDro databases were consulted until 1 April 2020. Seventeen articles written in English were included. Five of them studied the walking index for SCI, four studied the 10 meter walk test, and two studied the six-minute walk test, the timed Up and go test, and the Berg balance scale. The rest of the articles studied the following metrics: gait profile score, spinal cord injury functional ambulation profile, five times sit-to-stand test, spinal cord injury functional ambulation inventory, spinal cord independence measure (indoors and outdoors mobility items), locomotor stages in spinal cord injury, community balance and mobility scale, and activity-based balance level evaluation scale. The choice of a single or a set of metrics should be determined by the clinician. Based on the results obtained in this review, a combination of outcome measures is proposed to assess walking ability. Future work is required to integrate a more realistic environment for walking assessment.


Assuntos
Traumatismos da Medula Espinal , Caminhada , Humanos , Avaliação de Resultados em Cuidados de Saúde , Equilíbrio Postural , Estudos de Tempo e Movimento
20.
NeuroRehabilitation ; 48(3): 365-373, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33814469

RESUMO

BACKGROUND: There is a growing interest in the use of technology in the field of neurorehabilitation in order to quantify and generate knowledge about sensorimotor disorders after neurological diseases, understanding that the technology has a high potential for its use as therapeutic tools. Taking into account that the rehabilitative process of motor disorders should extend beyond the inpatient condition, it's necessary to involve low-cost technology, in order to have technological solutions that can approach the outpatient period at home. OBJECTIVE: to present the virtual applications-based RehabHand prototype for the rehabilitation of manipulative skills of the upper limbs in patients with neurological conditions and to determine the target population with respect to spinal cord injured patients. METHODS: Seven virtual reality applications have been designed and developed with a therapeutic sense, manipulated by means of Leap Motion Controller. The target population was determined from a sample of 40 people, healthy and patients, analyzing hand movements and gestures. RESULTS: The hand movements and gestures were estimated with a fitting rate between the range 0.607-0.953, determining the target population by cervical levels and upper extremity motor score. CONCLUSIONS: Leap Motion is suitable for a determined sample of cervical patients with a rehabilitation purpose.


Assuntos
Reabilitação Neurológica/métodos , Traumatismos da Medula Espinal/reabilitação , Jogos de Vídeo , Realidade Virtual , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Extremidade Superior/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA