Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Nanosci Nanotechnol ; 14(11): 8445-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25958543

RESUMO

The valence band discontinuity (ΔE(v)) of Y2O3/InGaZnO4 (IGZO) heterojunctions was measured by a core-level photoemission method. The Y2O3 exhibited a band gap of -6.27 eV from absorption measurements. A value of ΔE(v) = 0.44 ± 0.21 eV was obtained by using the Ga 2p3/2, Zn 2p3/2 and in 3d5/2 energy levels as references. Given the experimental bandgap of 3.2 eV for the IGZO, this would indicate a conduction band offset ΔE(c) of - 2.63 eV in the Y2O3/IGZO heterostructures and a nested interface band alignment.

2.
J Diabetes Sci Technol ; 4(1): 171-9, 2010 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-20167182

RESUMO

BACKGROUND: Immobilized aluminum gallium nitride (AlGaN)/GaN high electron mobility transistors (HEMTs) have shown great potential in the areas of pH, chloride ion, and glucose detection in exhaled breath condensate (EBC). HEMT sensors can be integrated into a wireless data transmission system that allows for remote monitoring. This technology offers the possibility of using AlGaN/GaN HEMTs for extended investigations of airway pathology of detecting glucose in EBC without the need for clinical visits. METHODS: HEMT structures, consisting of a 3-microm-thick undoped GaN buffer, 30-A-thick Al(0.3)Ga(0.7)N spacer, and 220-A-thick silicon-doped Al(0.3)Ga(0.7)N cap layer, were used for fabricating the HEMT sensors. The gate area of the pH, chloride ion, and glucose detection was immobilized with scandium oxide (Sc(2)O(3)), silver chloride (AgCl) thin film, and zinc oxide (ZnO) nanorods, respectively. RESULTS: The Sc(2)O(3)-gated sensor could detect the pH of solutions ranging from 3 to 10 with a resolution of approximately 0.1 pH. A chloride ion detection limit of 10(-8) M was achieved with a HEMT sensor immobilized with the AgCl thin film. The drain-source current of the ZnO nanorod-gated AlGaN/GaN HEMT sensor immobilized with glucose oxidase showed a rapid response of less than 5 seconds when the sensor was exposed to the target glucose in a buffer with a pH value of 7.4. The sensor could detect a wide range of concentrations from 0.5 nM to 125 microM. CONCLUSION: There is great promise for using HEMT-based sensors to enhance the detection sensitivity for glucose detection in EBC. Depending on the immobilized material, HEMT-based sensors can be used for sensing different materials. These electronic detection approaches with rapid response and good repeatability show potential for the investigation of airway pathology. The devices can also be integrated into a wireless data transmission system for remote monitoring applications. This sensor technology could use the exhaled breath condensate to measure the glucose concentration for diabetic applications.


Assuntos
Compostos de Alumínio/química , Técnicas Biossensoriais/instrumentação , Expiração , Gálio/química , Glucose/análise , Transistores Eletrônicos , Técnicas Biossensoriais/métodos , Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Sistemas Computacionais , Eletroquímica/instrumentação , Eletroquímica/métodos , Elétrons , Exsudatos e Transudatos/química , Humanos , Modelos Biológicos , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Nanotecnologia , Nanotubos/química , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA