Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Interv Card Electrophysiol ; 24(1): 53-61, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18975066

RESUMO

PURPOSE: The aim of the present study is to evaluate if remote monitoring with the CareLink Network may improve clinical management of tachyarrhythmias and heart failure episodes in patients treated with biventricular defibrillators (CRT-D). METHODS: Patients implanted with CRT-D for more than 6 months received the CareLink monitor and were trained to perform device interrogation. At-home transmissions were scheduled at 2 weeks, 1 and 2 months after training, with a final in-office visit after 3 months. RESULTS: Sixty-seven patients performed 264 data transmissions. Twenty-three unscheduled data transmissions were requested by the centers after patient contact. Ventricular tachyarrhythmias were reported in nine patients during 16 data reviews. Thirteen data reviews (81%) were performed remotely via CareLink transmissions (nine scheduled and four unscheduled), in seven patients. Of these events, in two cases (15%) in-hospital visits were requested, while in 11 (85%) no action was needed and no additional in-clinic visits were scheduled. During the study period, in 20/28 (71%) intra-thoracic impedance alerts, the patients remotely transmitted their device data. After remote data review, in ten cases drug therapy was adjusted by phone and in four cases no action was needed and the patient reassured. In six episodes an in-hospital extra visit was scheduled. On the whole, in 14 cases (70%), the patient could be managed remotely avoiding a visit to the hospital. CONCLUSIONS: Our study showed that remote follow-up is an efficient method to manage tachyarrhythmias and heart failure episodes in CRT-D patients. Early reaction to clinical events may improve overall patient care.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Telemedicina/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
2.
J Telemed Telecare ; 14(6): 290-4, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18776073

RESUMO

We conducted a multicentre study in five Italian hospitals to assess the feasibility of a remote monitoring service for the follow-up of implanted cardiac devices. The system was designed to monitor device performance as well as physiological aspects of the patient's condition. Sixty-seven patients (mean age 64 years) affected by chronic heart failure and with a biventricular implantable cardioverter defibrillator for cardiac re-synchronization therapy (CRT-D) were enrolled for a three-month observation period. A total of 267 device recordings were transmitted through the ordinary telephone network, with a success rate of 99%. The telemonitoring service was more efficient than conventional face-to-face follow-up in terms of the time savings: both for physicians (4.7 minutes versus 15 minutes for remote and conventional monitoring) and for patients (6.6 minutes versus 116.3 minutes). In addition, a total of 23 clinical events occurred during the study, but only two cases required a clinic visit, thus reducing inappropriate hospital admissions. Finally, the service was well accepted by all the users.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Monitorização Fisiológica/instrumentação , Telemedicina/métodos , Telefone/instrumentação , Análise Custo-Benefício , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/economia , Cooperação do Paciente , Satisfação do Paciente , Telemedicina/economia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA