RESUMO

Fast, accurate, and reliable diagnostic tests are critical for controlling the spread of the coronavirus disease 2019 (COVID-19) associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. The current gold standard for testing is real-time PCR; however, during the current pandemic, supplies of testing kits and reagents have been limited. We report the validation of a rapid (30 minutes), user-friendly, and accurate microchip real-time PCR assay for detection of SARS-CoV-2 from nasopharyngeal swab RNA extracts. Microchips preloaded with COVID-19 primers and probes for the N gene accommodate 1.2-µL reaction volumes, lowering the required reagents by 10-fold compared with tube-based real-time PCR. We validated our assay using contrived reference samples and 21 clinical samples from patients in Canada, determining a limit of detection of 1 copy per reaction. The microchip real-time PCR provides a significantly lower resource alternative to the Centers for Disease Control and Prevention-approved real-time RT-PCR assays with comparable sensitivity, showing 100% positive and negative predictive agreement of clinical samples.


Assuntos
Teste de Ácido Nucleico para COVID-19/normas , COVID-19/diagnóstico , Dispositivos Lab-On-A-Chip , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/normas , SARS-CoV-2/genética , Benchmarking , COVID-19/epidemiologia , Teste de Ácido Nucleico para COVID-19/instrumentação , Teste de Ácido Nucleico para COVID-19/métodos , Canadá/epidemiologia , Humanos , Limite de Detecção , Nasofaringe/virologia , Testes Imediatos , Kit de Reagentes para Diagnóstico/provisão & distribuição
2.
Assay Drug Dev Technol ; 15(4): 167-177, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28631939

RESUMO

A high-throughput screening (HTS) assay was developed for cotransporter, NKCC1, which is a potential target for the treatment of diverse disorders. This nonradioactive rubidium flux assay coupled with ion channel reader series provides a working screen for this target expressed in human embryonic kidney (HEK) cell line. An eightfold window of detection was achieved with the optimized assay. This new functional assay offered a robust working model for NKCC1 in determining reliable and concordant rank orders of the test compounds supporting its sensitivity and specificity. The robustness of manual assay indicated by Z' of 0.9 qualified its amenability to automation. The Z' of 0.7 was displayed by automated assay employed in high-throughput screening of compound libraries against this target. Being electrically neutral, the NKCC1 screening is difficult to achieve by both manual and automated electrophysiological techniques. These techniques, although considered gold standard, suffer from their inherent problems of being too slow to be in high-throughput format and with high running costs. In addition to being a functional assay for NKCC1, it is nontoxic as compared with thallium flux assay, which is prone to generate high number of false-positive/false-negative rates because of its innate fluorescence issues.


Assuntos
Ensaios de Triagem em Larga Escala , Rubídio/análise , Membro 2 da Família 12 de Carreador de Soluto/análise , Células HEK293 , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Rubídio/química , Membro 2 da Família 12 de Carreador de Soluto/metabolismo
3.
Assay Drug Dev Technol ; 9(6): 571-9, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22149887

RESUMO

Nine years ago Aurora Biomed Inc. (Vancouver, Canada) committed to gathering the brightest minds and the most innovative research companies at one conference. The Ion Channel Retreat provides a podium for scientific discourse spanning a wide range of ion channel disciplines. This conference has consistently provided a venue for people to share knowledge, exchange ideas, and establish partnerships. This conference continues to expand and grow each year, demonstrating the value of such a conference. Attendees at the 2011 Ion Channel retreat presented ion channel research from 12 different countries, representing research groups located on 5 of the 7 continents. Aurora Biomed's 2011 Retreat covered a variety of topics including Ion Channels as Disease Targets, Ion Channels as Pain Targets, TRP-channels, Ion Channel Screening Technologies, Cardiac Function and Pharmacology, Cardiac Safety and Toxicology, and Structure and Function of Ion Channels.


Assuntos
Ativação do Canal Iônico/fisiologia , Canais Iônicos/fisiologia , Analgésicos/administração & dosagem , Analgésicos/química , Analgésicos/metabolismo , Colúmbia Britânica , Fenômenos Fisiológicos Cardiovasculares/efeitos dos fármacos , Sistemas de Liberação de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/tendências , Humanos , Canais Iônicos/química , Dor/tratamento farmacológico , Dor/metabolismo
4.
Assay Drug Dev Technol ; 8(6): 638-44, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21158683

RESUMO

Eight years ago Aurora Biomed Inc. (Vancouver, Canada) committed to gathering the brightest minds and the most innovative research companies at one conference. We sought to provide a podium for scientific discourse spanning a wide range of ion channel disciplines. Since then, researchers from both academia and industry have come together each year to share their knowledge. With attendees from 17 different countries at the 2010 Ion Channel Retreat, this conference continues to grow, and is a testimony to the importance of ion channel research. Aurora Biomed's 2010 Retreat covered a variety of topics, including Ion Channels as Disease Targets, Ion Channels as Pain Targets, K-Channels, TRP-channels, Ion Channel Screening Technologies, Ion Channels in Safety Pharmacology, and Structure and Function of Ion Channels.


Assuntos
Canais Iônicos , Desenho de Fármacos , Descoberta de Drogas , Humanos , Ativação do Canal Iônico , Canais Iônicos/química , Canais Iônicos/metabolismo , Terapia de Alvo Molecular , Dor/tratamento farmacológico , Dor/metabolismo
5.
Assay Drug Dev Technol ; 8(1): 114-7, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20158437

RESUMO

Human Na+, K+ ATPase, an ATP-driven ion transporter, is an emerging drug target for heart-related conditions. Three types of assays including purified enzyme, radiotracer flux, and cold Rb+ flux have been used to determine the activity of this transporter. As an alternative to primary cardiomyocytes, mouse embryonic stem cells-derived cardiomyocytes with functional expression of essential cardiac ion channels were used in the present studies. The results on its pharmacology with digitoxin and ouabain, the 2 well-known cardioglycosides, imply that these cardiomyocytes can be used as a predictive model for the identification of modulators of Na+, K+ ATPase in HTS format.


Assuntos
Miócitos Cardíacos/metabolismo , Rubídio/farmacocinética , ATPase Trocadora de Sódio-Potássio/metabolismo , Células-Tronco/citologia , Animais , Células Cultivadas , Digitoxina/farmacologia , Ensaios de Triagem em Larga Escala , Camundongos , Ouabaína/farmacologia , ATPase Trocadora de Sódio-Potássio/antagonistas & inibidores
6.
Assay Drug Dev Technol ; 5(3): 373-80, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17638537

RESUMO

The Kv1.3 channels expressed by human T lymphocytes are emerging as important therapeutic targets. Peptides like agitoxin and margatoxin in scorpion venom and some non-peptide small molecules are known to inhibit this channel. Since such blockers cannot be used as drugs, pharma has a need to discover effective blockers. The major limiting factor for such development has been the lack of a reliable high-throughput screening (HTS) technology. A cell-based HTS assay for this target was developed in 96-well format to facilitate screening of many candidates. The assay incorporates rubidium ion as a tracer for potassium ion, which can be analyzed by the atomic absorption spectroscopy. The assay provided a Z' factor of 0.813 with more than a 4.5-fold window of detection. The two known blockers agitoxin and margatoxin gave a 50% inhibitory concentration (IC(50)) of 1.52 and 2 nM, respectively. These values are about five- and 2.8-fold higher than their IC(50) values obtained from patch clamp. Some non-peptide compounds like tamoxifen, nifedipine, and fluoxetine also inhibited the efflux through these channels, whereas astemizole and pimozide (potent human ether-a-go-go-related gene blockers) did not block Kv1.3 activity.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Canal de Potássio Kv1.3/efeitos dos fármacos , Bloqueadores dos Canais de Potássio/farmacologia , Rubídio/metabolismo , Animais , Células CHO , Cricetinae , Cricetulus , Feminino , Fluoxetina/farmacologia , Concentração de Íons de Hidrogênio , Canal de Potássio Kv1.3/fisiologia
7.
Assay Drug Dev Technol ; 4(1): 65-71, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16506890

RESUMO

An atomic absorption spectroscopy-based detection system was employed to develop a new non-radioactive flux assay for chloride (Cl-) channels in a high throughput format. Cl- flux is assayed by measuring the extent to which Cl- precipitates an excess amount of silver ions (Ag+). A linear correlation was observed between theoretical and determined Cl- concentration with an r2 value of 0.996. The assay was found to be free from interference from various ions and proteins. The assay was used to study the physiology of endogenously expressed Cl- channels in a Chinese hamster ovary-K1 cell line. Cl- efflux was activated in response to an increased concentration of K+ (100 mM), Ca2+ (4 mM), and ionomycin (10 microM) as calcium ionophore. The efflux was also sensitive to pH as slightly higher efflux of Cl- was observed at an acidic pH of 3.2 in comparison to the neutral pH of 7.4. The Cl- efflux was inhibited by 100 microM 4,4'-diisothiocyanostilbene-2,2'-disulfonic acid (DIDS) and 500 microM 5-nitro-2-(3-phenylpropylamino) benzoate (NPPB) but not by tolbutamide, niflumic acid, or glybenclamide, indicating that the channel current is not sensitive to other cystic fibrosis transmembrane conductance regulator inhibitors. The 50% inhibitory concentration (IC50) values of DIDS at pH 7.4 and pH 3.2 were 17 microM and 19 microM, respectively. An IC50 of 26 microM was observed for NPPB. The assay had a Z' factor of 0.678.


Assuntos
Canais de Cloreto/fisiologia , Ácido 4,4'-Di-Isotiocianoestilbeno-2,2'-Dissulfônico/farmacologia , Animais , Células CHO , Canais de Cloreto/efeitos dos fármacos , Canais de Cloreto/genética , Cloretos/farmacologia , Cricetinae , Concentração de Íons de Hidrogênio , Cinética , Modelos Biológicos , Potássio/farmacologia , Reprodutibilidade dos Testes , Prata/farmacologia
8.
J Pharmacol Toxicol Methods ; 54(1): 42-55, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16326118

RESUMO

INTRODUCTION: The hERG (human ether-a-go-go related gene) potassium channel is required for normal cardiac repolarization, is susceptible to inhibition by a wide variety of compounds, and its blockage can lead to cardiac QT interval prolongation and life threatening arrhythmias. The present report examines the ability of hERG binding and functional assays to identify compounds with potential cardiovascular liabilities at the earliest stages of drug discovery. METHODS: Competitive binding assays were developed using (3)H-dofetilide and membranes from HEK293EBNA cells stably expressing recombinant hERG (HEK293-hERG) and IMR-32 cells expressing hERG endogenously. hERG functional assays were also developed using membrane potential indicator dye and rubidium efflux. The ability of these assays to identify compounds with potential adverse cardiac effects was examined using drugs with known cardiac effects ranging from those with no known adverse effects to drugs that were withdrawn from the market due to increased risk of sudden death associated with Torsades de Points. RESULTS: Binding assays using HEK293-hERG membranes and (3)H-dofetilide were robust (Z'=0.69+/-0.015, mean+/-S.E.M.), highly reproducible (test-retest slope=1.04, r(2)=0.98), and correlated well with IC(50) values obtained by patch clamp (slope=0.98, r(2)=0.89). Binding assays using IMR-32 membranes were less sensitive (Z'=0.4+/-0.03, mean+/-S.E.M., false negative rate=0.4) but still correlated well with patch clamp data (slope=1.06, r(2)=0.83). The hERG membrane potential assay could detect potent hERG inhibitors (defined by hERG patch clamp IC(50)<0.1 muM) using HEK293-hERG cells, but were prone to generate false-negative results with less potent inhibitors (false negative rate=0.5). Finally, the rubidium efflux assay gave highly reproducible results (Z'=0.80+/-0.02, mean+/-S.E.M.) that correlated with patch clamp IC(50) values (slope=0.87, r(2)=0.73). DISCUSSION: The hERG binding and rubidium efflux assays are robust, predictive of patch clamp results, and can be used at the earliest stages of drug discovery.


Assuntos
Canais de Potássio Éter-A-Go-Go/metabolismo , Ensaio Radioligante/métodos , Proteínas Recombinantes/metabolismo , Animais , Células CHO , Linhagem Celular , Cricetinae , Canal de Potássio ERG1 , Canais de Potássio Éter-A-Go-Go/biossíntese , Humanos , Ligação Proteica/fisiologia , Proteínas Recombinantes/biossíntese
9.
Assay Drug Dev Technol ; 2(5): 535-42, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15671651

RESUMO

A high-throughput screening (HTS) assay was developed for the Na(+),K(+)-ATPase channel in order to study rubidium uptake as a measure of the functional activity and modulation of this exchanger. The assay uses elemental rubidium as a tracer for K(+) ions. Three cell lines were used to study the exchanger, and the assay was performed in a 96-well microtiter plate format. Rb(+) uptake was carried by the CHO-K1 cells at 37 degrees C; the maximum ion influx was at 80 min of incubation of the cell line in the medium containing 5.4 mM RbCl. The cells were incubated in Rb(+) uptake buffer (5.4 mM) and with the pump blocker ouabain for 1, 2, and 3 h, respectively. A complete block of the Rb(+) uptake was observed with a 5 mM concentration of ouabain for all the three time intervals. The ouabain 50% inhibitory concentration (IC(50)) value for CHO-K1 cell line ATPase was observed to be 298 microM after 3 h of incubation. In addition, IC(50) values of 94 and 89 microM were observed at 30 min of incubation, indicating that the protocol shows reproducible results. A Z' factor higher than 0.7 was observed in the assays. These studies extend the profile of Na(+),K(+)-ATPases and demonstrate the feasibility of this HTS assay system to screen for compounds that pharmacologically modulate the function of Na(+),K(+)-ATPase.


Assuntos
Rubídio/metabolismo , ATPase Trocadora de Sódio-Potássio/metabolismo , Espectrofotometria Atômica/métodos , Animais , Células CHO , Cricetinae , Relação Dose-Resposta a Droga , Avaliação Pré-Clínica de Medicamentos/métodos , Inibidores Enzimáticos/farmacologia , Humanos , Ouabaína/farmacologia , Sensibilidade e Especificidade , ATPase Trocadora de Sódio-Potássio/antagonistas & inibidores
10.
Assay Drug Dev Technol ; 1(5): 709-17, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15090243

RESUMO

Ion channels have been identified as therapeutic targets in various disorders, such as cardiovascular disease, neurological disease, and cystic fibrosis. Flux assays to detect functional ionic flux through ion channels are becoming increasingly popular as tools for screening compounds. In an optimized flux assay, modulation of ion channel activity may produce readily detectable changes in radiolabeled or nonradiolabeled ionic flux. Technologies based on flux assays are currently available in a fully automated high throughput format for efficient screening. This application offers sensitive, precise, and reproducible measurements giving accurate drug rank orders matching those of patch clamp data. Conveniently, the flux assay is amenable to adaptation for different ion channels, such as potassium, sodium, calcium, and chloride channels, by using suitable tracer ions. The nonradiolabeled rubidium-based flux assay coupled with the ion channel reader (ICR) technology has become very successful in ion channel activity analysis and is emerging as a popular technique in modern drug discovery.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Canais Iônicos/efeitos dos fármacos , Canais Iônicos/fisiologia , Transporte de Íons/efeitos dos fármacos , Transporte de Íons/fisiologia , Técnicas de Patch-Clamp/métodos , Ensaio Radioligante/métodos , Espectrometria de Fluorescência/métodos , Animais , Avaliação Pré-Clínica de Medicamentos/instrumentação , Humanos , Canais Iônicos/análise , Potenciais da Membrana/efeitos dos fármacos , Potenciais da Membrana/fisiologia , Técnicas de Patch-Clamp/instrumentação , Ensaio Radioligante/instrumentação , Espectrometria de Fluorescência/instrumentação , Avaliação da Tecnologia Biomédica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA