Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Am Coll Cardiol ; 84(8): 726-740, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39142727

RESUMO

BACKGROUND: Point-of-care (POC) high-sensitivity cardiac troponin assays may further accelerate the diagnosis of myocardial infarction (MI). OBJECTIVES: This study sought to assess the clinical and analytical performance of the novel high-sensitivity cardiac troponin I (hs-cTnI)-SPINCHIP POC test. METHODS: Adult patients presenting with acute chest discomfort to the emergency department were enrolled in an international, diagnostic, multicenter study. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all clinical information. We compared the discriminatory performance of hs-cTnI-SPINCHIP with current established central laboratory assays and derived an assay-specific hs-cTnI-SPINCHIP 0/1-hour algorithm. Secondary analyses included sample type comparisons (whole blood, fresh/frozen plasma, and capillary finger prick) and precision analysis. RESULTS: MI was the adjudicated final diagnosis in 214 (19%) of 1,102 patients. Area under the receiver-operating characteristic curve was 0.94 (95% CI: 0.92-0.95) for hs-cTnI-SPINCHIP vs 0.94 (95% CI: 0.92-0.95) for hs-cTnI-Architect (P = 0.907) and 0.93 (95% CI: 0.91-0.95) for high-sensitivity cardiac troponin T Elecsys (P = 0.305). A cutoff <7 ng/L at presentation (if chest pain onset was >3 hours) or <7 ng/L together with a 0/1-hour delta of <4 ng/L ruled out 51% with a sensitivity and negative predictive value of 100% (95% CI: 97.7%-100%) and 100% (95% CI: 99.0%-100%), respectively. A hs-cTnI-SPINCHIP concentration ≥36 ng/L or a 0/1-hour delta ≥11 ng/L ruled in 27% with a specificity and positive predictive value of 90.9% (95% CI: 88.3%-92.9%) and 72.9% (95% CI: 66.4%-78.6%), respectively. Bootstrap internal validation confirmed excellent diagnostic performance. High agreement was observed between different sample types. CONCLUSIONS: The SPINCHIP hs-cTnI POC test has very high diagnostic accuracy. Its assay-specific 0/1-hour algorithm achieved very high sensitivity/negative predictive value and specificity/positive predictive value for rule-out/in MI. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE] Study [APACE]; NCT00470587).


Assuntos
Infarto do Miocárdio , Troponina I , Humanos , Troponina I/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Biomarcadores/sangue , Estudos Prospectivos , Sensibilidade e Especificidade
2.
Clin Res Cardiol ; 113(4): 533-545, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37421436

RESUMO

BACKGROUND: The GRACE risk score is generically recommended by guidelines for timing of invasive coronary angiography without stating which score should be used. The aim was to determine the diagnostic performance of different GRACE risk scores in comparison to the ESC 0/1 h-algorithm using high-sensitivity cardiac troponin (hs-cTn). METHODS: Prospectively enrolled patients presenting with symptoms suggestive of myocardial infarction (MI) in two large studies testing biomarker diagnostic strategies were included. Five GRACE risk scores were calculated. The amount of risk reclassification and the theoretical impact on guideline-recommended timing of invasive coronary angiography was studied. RESULTS: Overall, 8,618 patients were eligible for analyses. Comparing different GRACE risk scores, up to 63.8% of participants were reclassified into a different risk category. The proportion of MIs identified (i.e., sensitivity) dramatically differed between GRACE risk scores (range 23.8-66.5%) and was lower for any score than for the ESC 0/1 h-algorithm (78.1%). Supplementing the ESC 0/1 h-algorithm with a GRACE risk score slightly increased sensitivity (P < 0.001 for all scores). However, this increased the number of false positive results. CONCLUSION: The substantial amount of risk reclassification causes clinically meaningful differences in the proportion of patients meeting the recommended threshold for pursuing early invasive strategy according to the different GRACE scores. The single best test to detect MIs is the ESC 0/1 h-algorithm. Combining GRACE risk scoring with hs-cTn testing slightly increases the detection of MIs but also increases the number of patients with false positive results who would undergo potential unnecessarily early invasive coronary angiography.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Humanos , Troponina , Síndrome Coronariana Aguda/diagnóstico , Angiografia Coronária , Medição de Risco/métodos , Infarto do Miocárdio/diagnóstico
3.
Am Heart J ; 268: 104-113, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38042459

RESUMO

BACKGROUND: The high-sensitivity cardiac troponin (hs-cTn) I point-of-care (POC) hs-cTnI-PATHFAST assay has recently become clinically available. METHODS: We aimed to externally validate the hs-cTnI-PATHFAST 0/1h-algorithm recently developed for the early diagnosis of non-ST-segment-elevation myocardial infarction (NSTEMI) and derive and validate a 0/2-algorithm in patients presenting to the emergency department with acute chest discomfort included in a multicenter diagnostic study. Two independent cardiologists centrally adjudicated the final diagnoses using all the clinical and study-specific information available including serial measurements of hs-cTnI-Architect. RESULTS: Among 1,532 patients (median age 60 years, 33% [n = 501] women), NSTEMI was the final diagnosis in 13%. External validation of the hs-cTnI-PATHFAST 0/1h-algorithm showed very high negative predictive value (NPV; 100% [95%CI, 99.5%-100%]) and sensitivity 100% (95%CI, 98.2%-100%) for rule-out of NSTEMI. Positive predictive value (PPV) and specificity for rule-in of NSTEMI were high (74.9% [95%CI, 68.3%-80.5%] and 96.4% [95%CI, 95.2%-97.3%], respectively). Among 1,207 patients (median age 61 years, 32% [n = 391] women) available for the derivation (n = 848) and validation (n = 359) of the hs-cTnI-PATHFAST 0/2h-algorithm, a 0h-concentration <3 ng/L or a 0h-concentration <4 ng/L with a 2h-delta <4ng/L ruled-out NSTEMI in 52% of patients with a NPV of 100% (95%CI, 98-100) and sensitivity of 100% (95%CI, 92.9%-100%) in the validation cohort. A 0h-concentration ≥90ng/L or a 2h-delta ≥ 55ng/L ruled-in 38 patients (11%): PPV 81.6% (95%CI, 66.6-90.8), specificity 97.7% (95%CI, 95.4-98.9%). CONCLUSIONS: The POC hs-cTnI-PATHFAST assay allows rapid and effective rule-out and rule-in of NSTEMI using both a 0/1h- and a 0/2h-algorithm with high NPV/sensitivity for rule-out and high PPV/specificity for rule-in. CLINICAL TRIAL REGISTRATION: NCT00470587.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos , Biomarcadores , Troponina I , Algoritmos , Troponina T
4.
Eur Heart J Acute Cardiovasc Care ; 12(10): 693-702, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37435949

RESUMO

AIMS: The utility of clinical risk scores regarding the prediction of major adverse cardiac events (MACE) is uncertain. We aimed to directly compare the prognostic performance of five established clinical risk scores as well as an unstructured integrated clinical judgement (ICJ) of the treating emergency department (ED) physician. METHODS AND RESULTS: Thirty-day MACE including all-cause death, life-threatening arrhythmia, cardiogenic shock, acute myocardial infarction (including the index event), and unstable angina requiring urgent coronary revascularization were centrally adjudicated by two independent cardiologists in patients presenting to the ED with acute chest discomfort in an international multicentre study. We compared the prognostic performance of the HEART score, GRACE score, T-MACS, TIMI score, and EDACS, as well as the unstructured ICJ of the treating ED physician (visual analogue scale to estimate the probability of acute coronary syndrome, ranging from 0 to 100). Among 4551 eligible patients, 1110/4551 patients (24.4%) had at least one MACE within 30 days. Prognostic accuracy was high and comparable for the HEART score, GRACE score, T-MACS, and ICJ [area under the receiver operating characteristic curve (AUC) 0.85-0.87] but significantly lower and only moderate for the TIMI score (AUC 0.79, P < 0.001) and EDACS (AUC 0.74, P < 0.001), resulting in sensitivities for the rule-out of 30-day MACE of 93-96, 87 (P < 0.001), and 72% (P < 0.001), respectively. CONCLUSION: The HEART score, GRACE score, T-MACS, and unstructured ICJ of the treating physician, not the TIMI score or EDACS, performed well for the prediction of 30-day MACE and may be considered for routine clinical use. TRIAL REGISTRATION: ClinicalTrials.gov number NCT00470587.


Assuntos
Síndrome Coronariana Aguda , Humanos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/complicações , Medição de Risco/métodos , Dor no Peito/etiologia , Estudos Prospectivos , Fatores de Risco , Raciocínio Clínico , Serviço Hospitalar de Emergência
5.
Eur Heart J Open ; 3(2): oead034, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37090057

RESUMO

Aims: Although the share of women in cardiology in Germany is growing steadily, this does not translate into leadership positions. Medical societies play a crucial role in shaping the national and international medical and scientific environment. The German Cardiac Society (DGK) aims to serve the public discourse on gender-equity by systematic analysis of data on gender representation within the society and in Germany. Methods and results: We present gender disaggregated data collection of members, official organs, working groups, scientific meetings, as well as awards of the DGK based on anonymized exports from the DGK office as well as on data gathered from the DGK web page. From 2000 to 2020, the overall number of DGK members as well as the share of women increased (12.5% to 25.3%). In 2021, the share of women ranged from 40% to 50% in earlier career stages but was substantially lower at senior levels (23.9% of consulting/attending physicians, 7.1% of physicians-in-chief, 3.4% of directors). The share of women serving in DGK working groups had gained overall proportionality, but nuclei and speaker positions were largely held by men. Boards and project groups were predominantly represented by men as well. At the DGK-led scientific meetings, women contributed more often in junior relative to (invited) senior roles. Conclusion: Increasing numbers of women in cardiology and in the DGK over the past 20 years did not translate into the respective increase in representation of women in leadership positions. There is an urgent need to identify and, more importantly, to overcome barriers towards gender equity. Transparent presentation of society-related data is the first step for future targeted actions in this regard.

6.
Interv Cardiol ; 18: e02, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36891034

RESUMO

Background: Coronary vessels in women may have anatomical and histological particularities. The aim of this study was to investigate sex-specific characteristics and outcomes of patients with calcified coronary arteries in the Prepare-CALC (Comparison of Strategies to Prepare Severely Calcified Coronary Lesions) trial. Methods: The Prepare-CALC trial randomised patients with severe coronary calcification to coronary lesion preparation either using modified balloons (MB; cutting or scoring) or rotational atherectomy (RA). Results: Of 200 randomised patients, 24% were women. Strategy success in general was similar between women (93.8%) and men (88.2%; p=0.27). For men, strategy success was significantly more common with an RA-based strategy than an MB-based strategy (98.7% in the RA group versus 77.3% in the MB group, p<0.001), whereas for women there was no evidence of a significant difference in strategy success between RA and MB (95.7% in the RA group versus 92% in the MB group, p>0.99, p for interaction between sex and treatment strategy=0.03). Overall, significant complications such as death, MI, stent thrombosis, bypass operation and perforations were rare and did not differ significantly by gender or treatment strategy. Plaque rupture and disrupted calcified nodules were more common in women. Conclusion: In a well-defined patient population with severely calcified coronary arteries, lesion preparation with an RA-strategy was superior to an MB-strategy in men. For women, both RA and MB strategies appear to have a similar success rate, although definitive conclusions are limited due to the small number of women in the trial.

7.
Eur Heart J Acute Cardiovasc Care ; 12(5): 283-295, 2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-36917461

RESUMO

AIMS: The presence of accompanying dyspnoea is routinely assessed and common in patients presenting with acute chest pain/discomfort to the emergency department (ED). We aimed to assess the association of accompanying dyspnoea with differential diagnoses, diagnostic work-up, and outcome. METHODS AND RESULTS: We enrolled patients presenting to the ED with chest pain/discomfort. Final diagnoses were adjudicated by independent cardiologists using all information including cardiac imaging. The primary diagnostic endpoint was the final diagnosis. The secondary diagnostic endpoint was the performance of high-sensitivity cardiac troponin (hs-cTn) and the European Society of Cardiology (ESC) 0/1h-algorithms for the diagnosis of myocardial infarction (MI). The prognostic endpoints were cardiovascular and all-cause mortality at two years. Among 6045 patients, 2892/6045 (48%) had accompanying dyspnoea. The prevalence of acute coronary syndrome (ACS) in patients with vs. without dyspnoea was comparable (MI 22.4% vs. 21.9%, P = 0.60, unstable angina 8.7% vs. 7.9%, P = 0.29). In contrast, patients with dyspnoea more often had cardiac, non-coronary disease (15.3% vs. 10.2%, P < 0.001). Diagnostic accuracy of hs-cTnT/I concentrations was not affected by the presence of dyspnoea (area under the curve 0.89-0.91 in both groups), and the safety of the ESC 0/1h-algorithms was maintained with negative predictive values >99.4%. Accompanying dyspnoea was an independent predictor for cardiovascular and all-cause death at two years [hazard ratio 1.813 (95% confidence intervals, 1.453-2.261, P < 0.01)]. CONCLUSION: Accompanying dyspnoea was not associated with a higher prevalence of ACS but with cardiac, non-coronary disease. While the safety of the diagnostic work-up was not affected, accompanying dyspnoea was an independent predictor for cardiovascular and all-cause death. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587.


Assuntos
Síndrome Coronariana Aguda , Infarto do Miocárdio , Humanos , Infarto do Miocárdio/diagnóstico , Valor Preditivo dos Testes , Prognóstico , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Dispneia/diagnóstico , Dispneia/epidemiologia , Dispneia/etiologia , Biomarcadores , Troponina T
8.
Ann Emerg Med ; 82(2): 194-202, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36774205

RESUMO

STUDY OBJECTIVE: The diagnostic performance of T-wave amplitudes for the detection of myocardial infarction is largely unknown. We aimed to address this knowledge gap. METHODS: T-wave amplitudes were automatically measured in 12-lead ECGs of patients presenting with acute chest discomfort to the emergency department within a prospective diagnostic multicenter study. The final diagnosis was centrally adjudicated by 2 independent cardiologists. Patients with left ventricular hypertrophy, complete left bundle branch block, or paced ventricular depolarization were excluded. The performance for lead-specific 95th-percentile thresholds were reported as likelihood ratios (lr), specificity, and sensitivity. RESULTS: Myocardial infarction was the final diagnosis in 445 (18%) of 2457 patients. In most leads, T-wave amplitudes tended to be greater in patients without myocardial infarction than those with myocardial infarction, and T-wave amplitude exceeding the 95th percentile had positive and negative lr close to 1 or with confidence intervals (CIs) crossing 1. The exceptions were leads III, aVR, and V1, which had positive lrs of 3.8 (95% CI, 2.7 to 5.3), 4.3 (95% CI, 3.1 to 6.0) and 2.0 (95% CI, 1.4 to 2.9), respectively. These leads normally have inverted T waves, so T-wave amplitude exceeding the 95th percentile reflects upright rather than increased-amplitude hyperacute T waves. CONCLUSION: Hyperacute T waves, when defined as increased T-wave amplitude exceeding the 95th percentile, did not provide useful information in diagnosing myocardial infarction in this sample.


Assuntos
Infarto do Miocárdio , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Infarto do Miocárdio/diagnóstico , Arritmias Cardíacas , Eletrocardiografia , Diagnóstico Precoce
9.
Am Heart J ; 255: 58-70, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36243111

RESUMO

BACKGROUND: We aimed to assess the diagnostic utility of the Dimension EXL LOCI High-Sensitivity Troponin I (hs-cTnI-EXL) assay. METHODS: This multicenter study included patients with chest discomfort presenting to the emergency department. Diagnoses were centrally and independently adjudicated by two cardiologists using all available clinical information. Adjudication was performed twice including serial measurements of high-sensitivity cardiac troponin (hs-cTn) I-Architect (primary analysis) and serial measurements of hs-cTnT-Elecsys (secondary analysis) in addition to the clinically used (hs)-cTn. The primary objective was to assess and compare the discriminatory performance of hs-cTnI-EXL, hs-cTnI-Architect and hs-cTnT-Elecsys for acute myocardial infarction (MI). Furthermore, we derived and validated a hs-cTnI-EXL-specific 0/1h-algorithm. RESULTS: Adjudicated MI was the diagnosis in 204/1454 (14%) patients. The area under the receiver operating characteristics curve for hs-cTnI-EXL was 0.94 (95%CI, 0.93-0.96), and comparable to hs-cTnI-Architect (0.95; 95%CI, 0.93-0.96) and hs-cTnT-Elecsys (0.93; 95%CI, 0.91-0.95). In the derivation cohort (n = 813), optimal criteria for rule-out of MI were <9ng/L at presentation (if chest pain onset >3h) or <9ng/L and 0h-1h-change <5ng/L, and for rule-in ≥160ng/L at presentation or 0h-1h-change ≥100ng/L. In the validation cohort (n = 345), these cut-offs ruled-out 56% of patients (negative predictive value 99.5% (95%CI, 97.1-99.9), sensitivity 97.8% (95%CI, 88.7-99.6)), and ruled-in 9% (positive predictive value 83.3% (95%CI, 66.4-92.7), specificity 98.3% (95%CI, 96.1-99.3)). Secondary analyses using adjudication based on hs-cTnT measurements confirmed the findings. CONCLUSIONS: The overall performance of the hs-cTnI-EXL was comparable to best-validated hs-cTnT/I assays and an assay-specific 0/1h-algorithm safely rules out and accurately rules in acute MI. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587.


Assuntos
Infarto do Miocárdio , Troponina I , Humanos , Estudos Prospectivos , Biomarcadores , Curva ROC , Infarto do Miocárdio/diagnóstico , Troponina T
10.
Eur Heart J Acute Cardiovasc Care ; 11(11): 834-840, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36179255

RESUMO

AIMS: After rule-out of non-ST elevation myocardial infarction (NSTEMI) with the European Society of Cardiology (ESC) 0/1 h-algorithms, it is unclear which patients require further anatomical or functional cardiac testing. To test the safety and efficacy of the no-objective-testing (NOT)-rules after NSTEMI rule-out by the ESC 0/1 h-algorithms. METHODS AND RESULTS: International, prospective, diagnostic multicentre study enrolling adult patients presenting with chest pain to the emergency department. Central adjudication of final diagnosis by two independent cardiologists using information including cardiac imaging. Primary endpoints were the safety and efficacy of the NOT-rules for the rule-out of major adverse cardiovascular events (MACE). Secondary endpoints included 365-day and 2-year MACE. Among 4804 and 4569 patients with available 0/1 h high-sensitivity cardiac troponin (hs-cTn)T-Elecsys or hs-cTnI-Architect concentrations, 2783 (58%) and 2252 (49%) were eligible for application of the NOT-rules after rule-out of NSTEMI by the ESC hs-cTnT/I-0/1h-algorithm. The first rule identified 26% of patients with a sensitivity of 100% (95%CI 98.3-100%) and a negative predictive value (NPV) of 100% (95% CI, n.c.). The second and third rules both identified 31% of patients with a sensitivity of 99.5% (95% CI 97.4-99.9%) and a NPV of 99.9% (95% CI 99.2-99.9%). Similar findings emerged for hs-cTnI. High safety was confirmed for rule-out of 365-day and 2-year MACE and proven to be superior to the HEART Score. CONCLUSION: All three NOT-rules performed very well for rule-out of MACE. The third NOT-rule best balanced feasibility, safety, and efficacy by identifying nearly one out of three patients as low-risk and may not require further cardiac testing. https://clinicaltrials.gov/ct2/show/NCT00470587.


Assuntos
Cardiologia , Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Adulto , Humanos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Estudos Prospectivos , Infarto do Miocárdio/diagnóstico , Troponina I , Algoritmos , Biomarcadores , Troponina T
11.
Eur Heart J Acute Cardiovasc Care ; 11(1): 62-74, 2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-34195803

RESUMO

AIMS: To directly compare the diagnostic accuracy of high-sensitivity cardiac troponin (hs-cTn) T vs. hs-cTnI in the early non-invasive differentiation of Type 1 myocardial infarction (T1MI) due to plaque rupture and atherothrombosis from Type 2 myocardial infarction (T2MI) due to supply-demand mismatch. METHODS AND RESULTS: In a prospective multicentre diagnostic study, two independent cardiologists centrally adjudicated the final diagnosis of T1MI vs. T2MI according to the fourth universal definition of myocardial infarction (MI), using all available clinical information including cardiac imaging in patients presenting with acute chest pain. Diagnostic accuracy was quantified by the area under the receiver operating characteristics curve (AUC). The most extensively validated hs-cTnT-Elecsys and hs-cTnI-Architect assays were measured at presentation, 1 h, and 2 h. Among 5887 patients, 1106 (19%) had a final diagnosis of MI, including 860 (78%) T1MI and 246 (22%) T2MI. The AUC of hs-cTnT-Elecsys to differentiate T1MI from T2MI was moderate and comparable to that provided by hs-cTnI-Architect: hs-cTnT-Elecsys AUC-presentation 0.67 [95% confidence interval (CI) 0.64-0.71], AUC-1 h 0.70 (95% CI 0.66-0.74), and AUC-2 h 0.71 (95% CI 0.66-0.75) vs. hs-cTnI-Architect AUC-presentation 0.71 (95% CI 0.67-0.74), AUC-1 h 0.72 (95% CI 0.68-0.76), and AUC-2 h 0.74 (95% CI 0.69-0.78), all P = not significant (NS). Similarly, the AUC of absolute changes was moderate and comparable for hs-cTnT-Elecsys and hs-cTnI-Architect (all P = NS). Cut-off concentrations achieving at least 90% specificity for the differentiation of T1MI vs. T2MI were >114 ng/L for hs-cTnT-Elecsys [odds ratio (OR) 4.2, 95% CI 2.7-6.6] and >371 ng/L for hs-cTnI-Architect (OR 4.0, 95% CI 2.6-6.2). CONCLUSION: hs-cTnT-Elecsys and hs-cTnI-Architect provided comparable, albeit only moderate, diagnostic accuracy for the early differentiation of T1MI vs. T2MI. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov number, NCT00470587, https://clinicaltrials.gov/ct2/show/NCT00470587.


Assuntos
Infarto do Miocárdio , Troponina T , Biomarcadores , Diagnóstico Precoce , Humanos , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos
13.
Am Heart J ; 242: 132-137, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34508692

RESUMO

The 2020 guidelines of the European Society of Cardiology (ESC) recommend a novel ESC 0/2h-algorithm as the preferred alternative to the ESC 0/1h-algorithm in the early triage for rule-out and/or rule-in of Non-ST-segment-elevation myocardial infarction (NSTEMI). The aim was to prospectively validate the performance of the ESC 0/2h-algorithm using the high-sensitivity cardiac troponin I (hs-cTnI) assay (ARCHITECT) in an international, multicenter diagnostic study enrolling patients presenting with acute chest discomfort to the emergency department.


Assuntos
Algoritmos , Infarto do Miocárdio , Troponina I , Biomarcadores/sangue , Diagnóstico Precoce , Humanos , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Troponina I/sangue
15.
JAMA Cardiol ; 6(7): 771-780, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33881449

RESUMO

Importance: Rapid and accurate noninvasive discrimination of type 2 myocardial infarction (T2MI), which is because of a supply-demand mismatch, from type 1 myocardial infarction (T1MI), which arises via plaque rupture, is essential, because treatment differs substantially. Unfortunately, this is a major unmet clinical need, because even high-sensitivity cardiac troponin (hs-cTn) measurement provides only modest accuracy. Objective: To test the hypothesis that novel cardiovascular biomarkers quantifying different pathophysiological pathways involved in T2MI and/or T1MI may aid physicians in the rapid discrimination of T2MI vs T1MI. Design, Setting, and Participants: This international, multicenter prospective diagnostic study was conducted in 12 emergency departments in 5 countries (Switzerland, Spain, Italy, Poland, and the Czech Republic) with patients presenting with acute chest discomfort to the emergency departments. The study quantified the discrimination of hs-cTn T, hs-cTn I, and 17 novel cardiovascular biomarkers measured in subsets of consecutively enrolled patients against a reference standard (final diagnosis), centrally adjudicated by 2 independent cardiologists according to the fourth universal definition of MI, using all information, including cardiac imaging and serial measurements of hs-cTnT or hs-cTnI. Results: Among 5887 patients, 1106 (18.8%) had an adjudicated final diagnosis of MI; of these, 860 patients (77.8%) had T1MI, and 246 patients (22.2%) had T2MI. Patients with T2MI vs those with T1MI had lower concentrations of biomarkers quantifying cardiomyocyte injury hs-cTnT (median [interquartile range (IQR)], 30 (17-55) ng/L vs 58 (28-150) ng/L), hs-cTnI (median [IQR], 23 [10-83] ng/L vs 115 [28-576] ng/L; P < .001), and cardiac myosin-binding protein C (at presentation: median [IQR], 76 [38-189] ng/L vs 257 [75-876] ng/L; P < .001) but higher concentrations of biomarkers quantifying endothelial dysfunction, microvascular dysfunction, and/or hemodynamic stress (median [IQR] values: C-terminal proendothelin 1, 97 [75-134] pmol/L vs 68 [55-91] pmol/L; midregional proadrenomedullin, 0.97 [0.67-1.51] pmol/L vs 0.72 [0.53-0.99] pmol/L; midregional pro-A-type natriuretic peptide, 378 [207-491] pmol/L vs 152 [90-247] pmol/L; and growth differentiation factor 15, 2.26 [1.44-4.35] vs 1.56 [1.02-2.19] ng/L; all P < .001). Discrimination for these biomarkers, as quantified by the area under the receiver operating characteristics curve, was modest (hs-cTnT, 0.67 [95% CI, 0.64-0.71]; hs-cTn I, 0.71 [95% CI, 0.67-0.74]; cardiac myosin-binding protein C, 0.67 [95% CI, 0.61-0.73]; C-terminal proendothelin 1, 0.73 [95% CI, 0.63-0.83]; midregional proadrenomedullin, 0.66 [95% CI, 0.60-0.73]; midregional pro-A-type natriuretic peptide, 0.77 [95% CI, 0.68-0.87]; and growth differentiation factor 15, 0.68 [95% CI, 0.58-0.79]). Conclusions and Relevance: In this study, biomarkers quantifying myocardial injury, endothelial dysfunction, microvascular dysfunction, and/or hemodynamic stress provided modest discrimination in early, noninvasive diagnosis of T2MI.


Assuntos
Infarto do Miocárdio/diagnóstico , Idoso , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/fisiopatologia , Placa Aterosclerótica/complicações , Estudos Prospectivos , Ruptura Espontânea , Troponina I/sangue , Troponina T/sangue
17.
Am Heart J ; 234: 1-11, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33428901

RESUMO

BACKGROUND: In acute myocardial infarction complicated by cardiogenic shock the use of mechanical circulatory support devices remains controversial and data from randomized clinical trials are very limited. Extracorporeal life support (ECLS) - venoarterial extracorporeal membrane oxygenation - provides the strongest hemodynamic support in addition to oxygenation. However, despite increasing use it has not yet been properly investigated in randomized trials. Therefore, a prospective randomized adequately powered clinical trial is warranted. STUDY DESIGN: The ECLS-SHOCK trial is a 420-patient controlled, international, multicenter, randomized, open-label trial. It is designed to compare whether treatment with ECLS in addition to early revascularization with percutaneous coronary intervention or alternatively coronary artery bypass grafting and optimal medical treatment is beneficial in comparison to no-ECLS in patients with severe infarct-related cardiogenic shock. Patients will be randomized in a 1:1 fashion to one of the two treatment arms. The primary efficacy endpoint of ECLS-SHOCK is 30-day mortality. Secondary outcome measures such as hemodynamic, laboratory, and clinical parameters will serve as surrogate endpoints for prognosis. Furthermore, a longer follow-up at 6 and 12 months will be performed including quality of life assessment. Safety endpoints include peripheral ischemic vascular complications, bleeding and stroke. CONCLUSIONS: The ECLS-SHOCK trial will address essential questions of efficacy and safety of ECLS in addition to early revascularization in acute myocardial infarction complicated by cardiogenic shock.


Assuntos
Oxigenação por Membrana Extracorpórea , Infarto do Miocárdio/terapia , Revascularização Miocárdica/métodos , Ponte de Artéria Coronária/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Fibrinolíticos/uso terapêutico , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Prognóstico , Estudos Prospectivos , Qualidade de Vida , Tamanho da Amostra , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade
18.
Eur Heart J Digit Health ; 1(1): 10-19, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36713964

RESUMO

Social media increasingly impact both the private and professional lives of the majority of the population, including individuals engaged in cardiovascular healthcare and research. Healthcare providers across the world use social media platforms such as Twitter or Facebook to find medical and scientific information, to follow scientific meetings, to discuss individual clinical cases with colleagues, and to engage with patients. While social media provide a means for fast, interactive and accessible communication without geographic boundaries, their use to obtain and disseminate information has limitations and the potential threats are not always clearly understood. Governance concerns include a lack of rigorous quality control, bias due to the pre-selection of presented content by filter algorithms, and the risk of inadvertent breach of patient confidentiality. This article provides information and guidance regarding the role and use of social media platforms in cardiovascular medicine, with an emphasis on the new opportunities for the dissemination of scientific information and continuing education that arise from their responsible use.

19.
Int J Cardiol ; 283: 41-47, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-30545622

RESUMO

BACKGROUND: The clinical availability of high-sensitivity cardiac troponin (hs-cTn) has enabled the development of several innovative strategies for the rapid rule-out of acute myocardial infarction (AMI). Due to the lack of direct comparisons, selection of the best strategy for clinical practice is challenging. METHODS: In a prospective international multicenter diagnostic study enrolling 3696 patients presenting with suspected AMI to the emergency department, we compared the safety and efficacy of 14 different hs-cTn-based strategies: hs-cTn concentrations below the limit of detection (LoD), dual-marker combining hs-cTn with copeptin, ESC 0 h/1 h-algorithm, 0 h/2 h-algorithm, 2 h-ADP-algorithm, NICE-algorithm, and ESC 0 h/3 h-algorithm, each using either hs-cTnT or hs-cTnI. The final diagnosis of AMI was adjudicated by two independent cardiologists using all available clinical information including cardiac imaging and serial hs-cTn concentrations. RESULTS: AMI was the final diagnosis in 16% of patients. Using hs-cTnT, safety quantified by the negative predictive value (NPV) and sensitivity was very high (99.8-100% and 99.5-100%) and comparable for all strategies, except the dual-marker approach (NPV 98.7%, sensitivity 96.7%). Similarly, using hs-cTnI, safety quantified by the NPV and sensitivity was very high (99.7-100% and 98.9-100%) and comparable for all strategies, except the dual-marker approach (NPV 96.9%, sensitivity 90.4%) and the NICE-algorithm (NPV 99.1%, sensitivity 94.7%). Efficacy, quantified by the percentage of patients eligible for rule-out, differed markedly, and was lowest for LoD-algorithm (15.7-26.8%). CONCLUSION: All rapid rule-out algorithms, except the dual-marker strategy and the NICE-algorithm using hs-cTnI, favorably combine safety and efficacy, and can be considered for routine clinical practice. CLINICAL TRIAL REGISTRATION: NCT00470587, http://clinicaltrials.gov/show/NCT00470587.


Assuntos
Algoritmos , Infarto do Miocárdio/diagnóstico , Guias de Prática Clínica como Assunto , Triagem/normas , Troponina I/sangue , Troponina T/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Angiografia Coronária , Unidades de Cuidados Coronarianos , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
20.
Int J Cardiol ; 269: 114-121, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30224031

RESUMO

BACKGROUND: Various scores have been derived for the assessment of syncope patients in the emergency department (ED) but stay inconsistently validated. We aim to compare their performance to the one of a common, easy-to-use CHADS2 score. METHODS: We prospectively enrolled patients ≥ 40 years old presenting with syncope to the ED in a multicenter study. Early clinical judgment (ECJ) of the treating ED-physician regarding the probability of cardiac syncope was quantified. Two independent physicians adjudicated the final diagnosis after 1-year follow-up. Major cardiovascular events (MACE) and death were recorded during 2 years of follow-up. Nine scores were compared by their area under the receiver-operator characteristics curve (AUC) for death, MACE or the diagnosis of cardiac syncope. RESULTS: 1490 patients were available for score validation. The CHADS2-score presented a higher or equally high accuracy for death in the long- and short-term follow-up than other syncope-specific risk scores. This score also performed well for the prediction of MACE in the long- and short-term evaluation and stratified patients with accuracy comparative to OESIL, one of the best performing syncope-specific risk score. All scores performed poorly for diagnosing cardiac syncope when compared to the ECJ. CONCLUSIONS: The CHADS2-score performed comparably to more complicated syncope-specific risk scores in the prediction of death and MACE in ED syncope patients. While better tools incorporating biochemical and electrocardiographic markers are needed, this study suggests that the CHADS2-score is currently a good option to stratify risk in syncope patients in the ED. TRIAL REGISTRATION: NCT01548352.


Assuntos
Eletrocardiografia/normas , Serviço Hospitalar de Emergência/normas , Síncope/diagnóstico , Síncope/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA