Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Zoo Wildl Med ; 53(2): 373-382, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35758579

RESUMO

Cardiac disease has been extensively documented in marine mammals; however, it remains difficult to diagnose antemortem. Assays measuring cardiac troponin I (cTnI) and N-terminal pro-brain natriuretic peptide (NT-proBNP) are used as sensitive and specific biomarkers of cardiac disease in many species, but have not been widely investigated in marine mammals. This study aimed to provide a set of reference values for cTnI and NT-proBNP in belugas (BW) (Delphinapterus leucas), sea otters (SO) (Enhydra lutris), Steller sea lions (SSL) (Eumetopias jubatus), and California sea lions (CSL) (Zalophus californianus) with and without cardiac disease, and to determine if these biomarkers are useful indicators of cardiac disease in these species. First, existing immunoassays for cTnI and NT-proBNP were successfully validated utilizing species-specific heart lysate spiked serum. Cohorts were defined by histopathology as animals with no evidence of cardiac disease ("control"), with confirmed cardiac disease ("disease"), and with concurrent renal and cardiac disease ("renal") for which serum samples were then analyzed. Serum concentration ranges for cTnI (ng/ml) and NT-proBNP (pmol/L) were determined for control and disease cohorts. There was significantly higher cTnI (P= 0.003) and NT-proBNP (P= 0.004) concentrations in the CSL disease cohort, as well as positive trends in BW, SO, and SSL disease cohorts that did not reach statistical significance. NT-proBNP concentrations were significantly higher in the CSL renal cohort compared with the control (P < 0.001) and disease (P= 0.007) cohorts. These results suggest that cTnI and NT-proBNP may be clinically useful in the antemortem diagnosis of cardiac disease in CSL, and warrant further investigation in BW, SO, and SL.


Assuntos
Cardiopatias , Troponina I , Animais , Biomarcadores , Estudos de Coortes , Cardiopatias/diagnóstico , Cardiopatias/veterinária , Humanos , Mamíferos
2.
Vet Clin Pathol ; 47(4): 539-555, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30476353

RESUMO

BACKGROUND: In a previous study, the validation of rat bone marrow (BM) collection, processing, and analysis using the Sysmex XT-2000iV (Sysmex Corporation, Kobe, Japan) hematology analyzer showed that the Sysmex hematology analyzer produced BM differential counts that were comparable to those obtained with microscopic differential counts. OBJECTIVE: This study was conducted to expand the validation of the Sysmex TNCC (total nucleated cell count) and 5-part BM differential in cynomolgus monkeys, Beagle dogs, and CD-1 mice, which are alternate species that are also frequently used in preclinical safety studies. METHODS: The Sysmex 5-part BM differential counts were generated with a two-step process, whereby proliferating and maturing erythroid and myeloid cells were determined by preset gating and lymphocytes were determined using species-specific B- and T-lymphocyte antibodies and a magnetic cell-sorting method (MACS). Agreement with microscopic myelograms with 500-cell differential counts was determined from BM suspensions of 62 cynomolgus monkeys, 47 Beagle dogs, and 44 CD-1 mice. RESULTS: The correlation coefficients between methods for myeloid to erythroid (M:E) ratios in all three species was > 0.928. The Bland-Altman differences between methods were approximately ± 0.3 units for the M:E ratio in dogs and mice, and +0.6 and -0.4 in monkeys. The upper limits of agreement for all three species were ≤7% for maturing myeloid cells, ≤6% for maturing erythroid cells, and ≤4% for proliferating myeloid cells, proliferating erythroid cells, and lymphocytes. CONCLUSIONS: The Sysmex XT-2000iV produces an automated M:E ratio and a 5-part differential count equivalent to microscopic differential counts in cynomolgus monkeys, Beagle dogs, and CD-1 mice.


Assuntos
Células da Medula Óssea/citologia , Contagem de Células/veterinária , Animais , Autoanálise/instrumentação , Autoanálise/veterinária , Contagem de Células/instrumentação , Cães/anatomia & histologia , Feminino , Macaca fascicularis/anatomia & histologia , Masculino , Camundongos/anatomia & histologia , Camundongos Endogâmicos C57BL/anatomia & histologia , Reprodutibilidade dos Testes
3.
J Zoo Wildl Med ; 46(3): 456-67, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26352948

RESUMO

Thyroid hormones play a critical physiologic role in regulating protein synthesis, growth, and metabolism. To date, because no published compilation of baseline values for thyroid hormones in beluga whales (Delphinapterus leucas) exists, assessment of thyroid hormone concentrations in this species has been underused in clinical settings. The purpose of this study was to document the concentrations of total thyroxine (tT4) and total triiodothyronine (tT3) in healthy aquarium-maintained and free-ranging beluga whales and to determine the influence of age, sex, and season on the thyroid hormone concentrations. Archived serum samples were collected from healthy aquarium-maintained (n=43) and free-ranging (n=39) belugas, and serum tT4 and tT3 were measured using chemiluminescence immunoassay. The mean tT4 concentration in aquarium-maintained belugas was 5.67±1.43 µg/dl and the mean tT3 concentration was 70.72±2.37 ng/dl. Sex comparisons showed that aquarium-maintained males had significantly greater tT4 and tT3 (9.70±4.48 µg/dl and 92.65±30.55 ng/dl, respectively) than females (7.18±2.82 µg/dl and 77.95±20.37 ng/dl) (P=0.004 and P=0.013). Age comparisons showed that aquarium-maintained whales aged 1-5 yr had the highest concentrations of tT4 and tT3 (8.17±0.17 µg/dl and 105.46±1.98 ng/dl, respectively) (P=0.002 and P<0.001). tT4 concentrations differed significantly between seasons, with concentrations in winter (4.59±1.09 µg/dl) being significantly decreased compared with spring (P=0.009), summer (P<0.0001), and fall (P<0.0001) concentrations. There was a significant difference in tT4 and tT3 concentrations between aquarium-maintained whales (5.67±1.43 µg/dl and 70.72±15.57 ng/dl, respectively) and free-ranging whales (11.71±3.36 µg/dl and 103.38±26.45 ng/dl) (P<0.0001 and P<0.001). Clinicians should consider biologic and environmental influences (age, sex, and season) for a more accurate interpretation of thyroid hormone concentrations in belugas. The findings of this study provide a baseline for thyroid health monitoring and comprehensive health assessments in both aquarium-maintained and free-ranging beluga whales.


Assuntos
Envelhecimento/sangue , Beluga/sangue , Estações do Ano , Tiroxina/sangue , Tri-Iodotironina/sangue , Animais , Animais Selvagens , Animais de Zoológico , Feminino , Masculino
4.
Vet Clin Pathol ; 43(2): 137-53, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24798181

RESUMO

BACKGROUND: In a previous study, it was demonstrated that bone marrow analysis using the Sysmex XT-2000iV hematology analyzer produced differential counts in untreated rats that were comparable to microscopic differential counts. OBJECTIVE: The aim of this study was to modulate hematopoiesis in rats in vivo either through pharmacologic treatment or serial phlebotomy, and to determine whether the Sysmex XT-2000iV could accurately analyze bone marrow quantitative changes when compared with results obtained by microscopy. METHODS: Rats were treated once with 0, 5, 20, and 40 mg/kg cyclophosphamide (CP), 0, 50, 100 IU/kg erythropoietin (EPO) on 4 consecutive days, or serial phlebotomy of 1-2 mL of blood for 4 days. Modulation of hematopoietic populations in bone marrow was evaluated using the Sysmex XT-2000iV hematology analyzer, and compared with microscopic differential counts. RESULTS: Correlation coefficients between M:E ratios determined by Sysmex and the microscopic method were 0.94, 0.96, and 0.98 for CP, EPO, or serial phlebotomy treatments, respectively. Mean concordance correlation coefficients for M:E demonstrated method agreement of 0.63, 0.92, and 0.85 for the 3 treatments. Quantitative automated and microscopic bone marrow differential counts were within the expected 95% confidence intervals for CP, EPO or serial phlebotomy. CONCLUSIONS: The Sysmex XT-2000iV provides quantitative bone marrow differential counts of bone marrow cell series in rats with treatment-induced changes which are comparable to microscopic differential counts. Reliable automatic bone marrow differential counting allows increased throughput, sensitivity, reproducibility, and enhanced interpretation of bone marrow evaluation in rodent preclinical studies.


Assuntos
Células da Medula Óssea/citologia , Ciclofosfamida/farmacologia , Eritropoetina/farmacologia , Imunossupressores/farmacologia , Animais , Células da Medula Óssea/efeitos dos fármacos , Contagem de Células/veterinária , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Avaliação Pré-Clínica de Medicamentos/veterinária , Feminino , Linfócitos/citologia , Linfócitos/efeitos dos fármacos , Masculino , Células Mieloides/citologia , Células Mieloides/efeitos dos fármacos , Flebotomia/veterinária , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Vet Clin Pathol ; 43(2): 125-36, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24597677

RESUMO

BACKGROUND: Preclinical drug trials frequently require assessment of bone marrow toxicity in animals to evaluate hematopoietic safety. Since the gold standard, cytologic evaluation, is time consuming and requires highly trained individuals, automated methods remain intriguing. OBJECTIVE: The Sysmex XT-2000iV hematology analyzer allows user-developed customizable gating. This study was conducted to validate the gating of bone marrow cell populations in Sysmex cytograms from untreated rats. METHODS: B- and T-lymphocytes and myeloid cells were experimentally depleted from Charles River Wistar Han IGS (CRL: WI [Han]) rat whole bone marrow suspension using a magnetic cell sorting (MACS) method. The positively and negatively selected populations were used to verify select gates within the Sysmex cytogram. Intra- and inter-animal precision, comparability between right and left femur, as well as agreement with microscopic myelograms based on 500 counted cells, were determined. RESULTS: Intra-sample precision and right-to-left femur comparability confirmed that gating was reproducible and stable. In 50 tested rats, myeloid to erythroid ratios (M:E) were 1.32 ± 0.33 in males and 1.38 ± 0.29 in females by Sysmex compared to 1.36 ± 0.32 in males and 1.42 ± 0.32 in females by microscopic evaluations. Bland-Altman differences between methods was ≤ ± 0.35 units for M:E, ≤ 5.4% for maturing myeloid cells, ≤ 3.4% for proliferating myeloid cells, ≤ 6.0% for maturing myeloid cells, ≤ 3.4% for proliferating myeloid cells, and ≤ 4.1% for lymphocytes. CONCLUSIONS: In untreated control Charles River Wistar Han IGS (CRL: WI [Han]) rats, the Sysmex XT-2000iV produced an automated M:E and 5-part differential count equivalent to microscopic differential counts.


Assuntos
Autoanálise/veterinária , Células da Medula Óssea/citologia , Animais , Autoanálise/instrumentação , Exame de Medula Óssea/veterinária , Contagem de Células/veterinária , Proliferação de Células , Sobrevivência Celular , Avaliação Pré-Clínica de Medicamentos/veterinária , Células Eritroides/citologia , Feminino , Citometria de Fluxo/instrumentação , Citometria de Fluxo/veterinária , Linfócitos/citologia , Masculino , Células Mieloides/citologia , Ratos , Ratos Wistar , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA