Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 193
Filtrar
1.
Biomedicines ; 12(6)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38927362

RESUMO

Critical-size bone defects necessitate bone void fillers that should be integrated well and be easily vascularized. One viable option is to use a biocompatible synthetic polymer and sonocoat it with zinc oxide (ZnO) nanoparticles (NPs). However, the ideal NP concentration and size must be assessed because a high dose of ZnO NPs may be toxic. Electrospun PDLLA/PLGA scaffolds were produced with different concentrations (0.5 or 1.0 s of sonocoating) and sizes of ZnO NPs (25 nm and 70 nm). They were characterized by SEM, EDX, ICP-OES, and the water contact angle. Vascularization and integration into the surrounding tissue were assessed with the CAM assay in the living chicken embryo. SEM, EDX, and ICP-OES confirmed the presence of ZnO NPs on polymer fibers. Sonocoated ZnO NPs lowered the WCA compared with the control. Smaller NPs were more pro-angiogenic exhibiting a higher vessel density than the larger NPs. At a lower concentration, less but larger vessels were visible in an environment with a lower cell density. Hence, the favored combination of smaller ZnO NPs at a lower concentration sonocoated on PDLLA/PLGA electrospun meshes leads to an advanced state of tissue integration and vascularization, providing a valuable synthetic bone graft to be used in clinics in the future.

2.
Cancers (Basel) ; 16(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38927915

RESUMO

BACKGROUND: Sarcomas present a unique challenge within healthcare systems due to their rarity and complex treatment requirements. This study explores the economic impact of sarcoma surgeries across three Swiss tertiary healthcare institutions, utilizing a consistent surgical approach by a single surgeon to eliminate variability in surgical expertise as a confounding factor. METHODS: By analyzing data from 356 surgeries recorded in a real-world-time data warehouse, this study assesses surgical and hospital costs relative to institutional characteristics and surgical complexity. RESULTS: Our findings reveal significant cost variations driven more by institutional resource management and pricing strategies than by surgical techniques. Surgical and total hospitalization costs were analyzed in relation to tumor dignity and complexity scores, showing that higher complexity and malignancy significantly increase costs. Interestingly, it was found that surgical costs accounted for only one-third of the total hospitalization costs, highlighting the substantial impact of non-surgical factors on the overall cost of care. CONCLUSIONS: The study underscores the need for standardized cost assessment practices and highlights the potential of predictive models in enhancing resource allocation and surgical planning. By advocating for value-based healthcare models and standardized treatment guidelines, this research contributes to more equitable and sustainable healthcare delivery for sarcoma patients. These insights affirm the necessity of including a full spectrum of care costs in value-based models to truly optimize healthcare delivery. These insights prompt a reevaluation of current policies and encourage further research across diverse geographical settings to refine cost management strategies in sarcoma treatment.

3.
J Vasc Surg Venous Lymphat Disord ; : 101934, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38925528

RESUMO

OBJECTIVE: Vascularized lymph node transfer (VLNT) has become an important surgical technique in the treatment of lymphedema. Considering the different available regions available for flap harvest, we aimed to analyze different donor sites for VLNT with respect to donor site morbidity, impact on limb volume, and patient-reported outcome measurements (PROMs). METHODS: A single-center prospective study of all patients undergoing VLNT at the Department of Plastic Surgery and Hand Surgery of the University Hospital Zurich between September 2016 and 2023 was conducted. Lymph nodes were harvested either from the omentum (gastroepiploic [GE]-VLNT), the lateral thoracic wall (LTW), or the superficial inguinal region (SI-VLNT). Volume measurements and PROMs were assessed preoperatively and at different postoperative intervals. RESULTS: Overall, 70 patients with upper limb lymphedema (21%) or lower limb lymphedema (79%) with different lymphedema stages were included. There were 49 patients who underwent GE-VLNT, followed by LTW-VLNT (n = 16) and SI-VLNT (n = 5). Lymph node harvest from the SI was associated with a significantly higher frequency of seroma development. The average percentage volume loss related in comparison to the preoperative volume of the affected limb was 9% after GE-VLNT, 10% after LTW-VLNT, and 5% after SI-VLNT without a significant difference between the groups. PROMs revealed significant improvements for physical functioning, symptoms and psychological well-being, with no differences between the VLNT techniques. CONCLUSIONS: VLNT leads to a significant improvement of quality of life and can decrease limb volume effectively, regardless of the selection of donor site. GE-VLNT has become our flap of choice owing to its low donor site morbidity and its properties that allow a double transplantation while avoiding a second donor site.

4.
Ann Plast Surg ; 93(2): 221-228, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38920154

RESUMO

INTRODUCTION: Postoperative chronic lymphocele and lymphedema represent severe burdens for soft tissue sarcoma patients who are already physically handicapped after an extensive surgery and a long recovery time. Incidences are high in the upper medial thigh. We have shifted our focus to lymphedema and lymphocele risk reduction with immediate lymphovenous anastomosis (LVA) after sarcoma resection. METHODS: We performed immediate lymphatic reconstruction in 11 patients after soft tissue sarcoma resection in the upper medial thigh. The postoperative course was followed up closely, and postoperative occurrence of lymphocele and lymphedema was clinically assessed. A literature search outlining the latest clinical data, current treatment strategy landscape, and their application into clinical practice was added to the investigation. RESULTS: A total of 19 LVA and 2 lympho-lymphatic anastomoses were performed in 11 patients immediately after tumor resection in an end-to-end manner. We found a postoperative lymphedema rate of 36% and a postoperative lymphocele rate of 27%. Mean follow-up time was 17 months. Average tumor volume was 749 cc. Our literature search yielded 27 articles reporting on immediate LVA in cancer patients. Incidences of secondary lymphedema after LVA for lymphedema prevention vary between 0% and 31.1%. Lymphocele prevention with LVA is poorly studied in sarcoma patients. CONCLUSION: Immediate lymphatic reconstruction improved the overall postoperative course of our patients. The current literature does not serve with high-quality studies about primary LVA preventing lymphedema and lymphocele formation. We conclude that this technique should be seen as an additional concept to achieve overall better postoperative outcomes in these challenging surgical settings. We strongly recommend to either anastomose or ligate severed lymphatics under the microscope primarily after sarcoma resection in the upper medial thigh area.


Assuntos
Anastomose Cirúrgica , Vasos Linfáticos , Linfedema , Linfocele , Complicações Pós-Operatórias , Sarcoma , Neoplasias de Tecidos Moles , Coxa da Perna , Humanos , Linfedema/cirurgia , Linfedema/etiologia , Linfedema/prevenção & controle , Anastomose Cirúrgica/métodos , Coxa da Perna/cirurgia , Linfocele/etiologia , Linfocele/cirurgia , Linfocele/prevenção & controle , Feminino , Pessoa de Meia-Idade , Vasos Linfáticos/cirurgia , Masculino , Sarcoma/cirurgia , Adulto , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Neoplasias de Tecidos Moles/cirurgia , Idoso , Resultado do Tratamento , Veias/cirurgia , Seguimentos , Estudos Retrospectivos
5.
Front Surg ; 11: 1415010, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38826811

RESUMO

Introduction: In recent years advances have been made in the microsurgical treatment of congenital or acquired central lymphatic lesions. While acquired lesions can result from any surgery or trauma of the central lymphatic system, congenital lymphatic lesions can have a variety of manifestations, ranging from singular thoracic duct abnormalities to complex multifocal malformations. Both conditions may cause recurrent chylous effusions and downstream lymphatic congestion depending on the anatomical location of the thoracic duct lesion and are associated with an increased mortality due to the permanent loss of protein and fluid. Methods: We present a case series of eleven patients undergoing central lymphatic reconstruction, consisting of one patient with a cervical iatrogenic thoracic duct lesion and eleven patients with different congenital thoracic duct lesions or thrombotic occlusions. Results: Anastomosis of the thoracic duct and a nearby vein was performed on different anatomical levels depending on the underlying central lymphatic pathology. Cervical (n = 4), thoracic (n = 1) or abdominal access (n = 5) was used for central lymphatic reconstruction with promising results. In 9 patients a postoperative benefit with varying degrees of symptom regression was reported. Conclusion: The presented case series illustrates the current rapid advances in the field of central microsurgical reconstruction of lymphatic lesions alongside the relevant literature.

6.
Aesthetic Plast Surg ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839615

RESUMO

INTRODUCTION: Botulinum toxin A (BoTA) is a neurotoxin formed by Clostridium botulinum, with a broad medical application spectrum. While the primary effect of BoTA is on the muscles, the effects of BoTA in other systems including the blood vasculature have already been examined, revealing unexpected actions. However, no studies exist to the best of our knowledge regarding the potential effects of BoTA on the lymphatic vascular system, possessing a critical role in health and disease. Isolated human lymphatic endothelial cells (LECs) were cultured in dedicated in vitro culture systems. The analysis including imaging and cell culture approaches as well as molecular biology techniques is performed to examine the LEC alterations occurring upon exposure to different concentrations of BoTA. MATERIALS AND METHODS: Human LECs were cultured and expanded on collagen-coated petri dishes using endothelial basal medium and the commercial product Botox from Allergan as used for all our experiments. Harvested cells were used in various in vitro functional tests to assess the morphologic and functional properties of the BoTA-treated LECs. Gene expression analysis was performed to assess the most important lymphatic system-related genes and pathways. RESULTS: Concentrations of 1, 5 or 10 U of BoTA did not demonstrate a significant effect regarding the proliferation and migration capacity of the LECs versus untreated controls. Interestingly, even the smallest BoTA dose was found to significantly decrease the cord-like-structure formation capacity of the seeded LECs. Gene expression analysis was used to underpin possible molecular alterations, suggesting no significant effect of BoTA in the modification of gene expression versus the starvation medium control. CONCLUSION: LECs appear largely unaffected to BoTA treatment, with an isolated effect on the cord-like-structure formation capacity. Further work needs to assess the effect of BoTA on the smooth-muscle-cell-covered collecting lymphatic vessels and the possible aesthetic implications of such an effect, due to edema formation. LEVEL OF EVIDENCE V: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

7.
J Robot Surg ; 18(1): 164, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581589

RESUMO

Robotic-assisted microsurgery has gained significant attention in recent years following the introduction of two dedicated microsurgical robotic systems specifically designed for this purpose. These feature higher degrees of movement and motion scaling which are useful tools, especially when performing surgery in areas of the body which are difficult to access. Robotic-assisted microsurgery has been implemented in lymphatic surgery as well as soft tissue reconstructive surgery at our institution over the past 2.5 years. Our study gives an insight into the details and outcomes of the first 100 consecutive (super-) microsurgical anastomoses in peripheral and central lymphatic reconstruction performed with the Symani® Surgical System between 2021 and 2024. In total, 67 patients were treated, receiving robotic-assisted lymphatic reconstruction with lymphatic tissue transfer (LTT) and/or lymphovenous anastomoses (LVA)/lympholymphatic anastomoses (LLA). No anastomosis-associated complications were recorded postoperatively. The majority of patients reported a postoperative improvement of their lymphedema or central lymphatic disorder. In conclusion, we show the successful implementation of the Symani® Surgical System into our clinical practice of lymphatic reconstruction. Although the necessary intraoperative setup and the use of intrinsic motion scaling lead to a slight increase in operating time, the presented study demonstrates the advantages of robotic assistance which becomes particularly evident in lymphatic surgery due to the involved deep surgical sites and the need for supermicrosurgical techniques.


Assuntos
Vasos Linfáticos , Linfedema , Procedimentos de Cirurgia Plástica , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Vasos Linfáticos/cirurgia , Anastomose Cirúrgica/métodos
9.
Burns ; 50(3): 569-577, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38216375

RESUMO

BACKGROUND: Burn patients are in a state of activated coagulation, putting them at risk for thromboembolic events. Additionally, certain patient-related factors are associated with an increased risk of thrombus formation. This study aimed to evaluate the incidence of thromboembolic events and identify potential risk factors, including patient characteristics, surgical treatment, anticoagulation strategies, and laboratory parameters. METHODS: A single-centre retrospective cohort study was conducted on all patients with burns treated between 2002 and 2020. Medical reports of patients with and without thromboembolic events were descriptively analysed. The association of time to thromboembolic events with total body surface area (TBSA) was assessed by cause-specific Cox models adjusted for different covariates. The association of time to thromboembolic events with type and dosage of anticoagulants was assessed using a cause-specific Cox proportional hazards model with time-dependent covariates, applied to a matched subset of patients. RESULTS: The incidence of thromboembolic events was 8.1% in a cohort of 642 patients. We found a statistically significant increase in the hazard for thromboembolic events by a factor of 1.02 (95% CI 1.00 to 1.03; P ≤ 0.05) per percent increase in TBSA. We identified former alcohol abuse (HR=2.54, CI 1.33 to 4.84, P = 0.005) and higher body mass index (HR=1.06, 95% CI 1.00 to 1.12, P = 0.046) as potential risk factors for the development of thromboembolic events. We further noted inadequate median anti-Factor-X activity levels and elevated C-reactive protein and procalcitonin levels at the time of the event. CONCLUSION: Our results showed a moderate risk of thromboembolic events among burn patients, underlining the importance of close monitoring with regard to thrombus formation. In particular, patients with higher TBSA, alcohol abuse and BMI may be evaluated more regularly for thromboembolic events. Anti-Factor-X activity levels should be determined regularly and therapy should be adjusted if necessary.


Assuntos
Alcoolismo , Queimaduras , Tromboembolia , Trombose , Humanos , Anticoagulantes/uso terapêutico , Estudos Retrospectivos , Alcoolismo/complicações , Queimaduras/complicações , Queimaduras/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Fatores de Risco
10.
Acta Histochem ; 126(2): 152136, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38295730

RESUMO

The duodenum acts as a vital organ that performs fundamental physiological functions like digestion and nutrient absorption. Situated in the lower abdomen, the duodenum is located between the stomach and the jejunum. Usually, the duodenum is divided into four anatomical portions. We here compare paraffin embedded and cryosections of the healthy rabbit duodenum for research purposes. This analysis evaluates the differential outcomes resulting from the application of these fixation methodologies in conjunction with immunohistochemical assays targeting extracellular matrix markers collagen I, collagen III, fibronectin, α-smooth muscle actin (α-SMA), and proliferation marker ki67 as well as inflammatory marker PAR-2. Subsequent recommendations are provided based on our findings. Furthermore, the advantage of an antigen retrieval step in immunohistochemical labelling of paraffin sections was demonstrated and confirmed with an isotype negative control. Basic classical histological stainings as HE, GT and elastin were also performed. Comparison of different stainings and labellings was performed in serial sections, showing that adjacent to the circular muscle of the duodenum, the connective tissue was composed of collagen I and fibronectin, while the artery and vein walls were predominantly α-SMA positive. Moreover, PAR-2 immunohistochemical staining was performed, where particularly a type of gland adjacent to Brunner's glands showed prominent PAR-2 positive areas, while the Brunner's glands themselves were PAR-2 negative. Proliferating ki67 positive cells facing the lumen were highly abundant in all kinds of glands except for the Brunner's glands. This effort serves to furnish the research community with reference imagery pertinent to scientists opting for the rabbit duodenum model. The diversity of staining techniques employed herein establishes a foundational repository of images, primed for comparative analysis against pathological conditions. Furthermore, these images hold the potential to illustrate inter-species variations. For instance, they can be juxtaposed against murine or rat intestinal tracts, or even offer insights into the human context.


Assuntos
Duodeno , Fibronectinas , Humanos , Coelhos , Animais , Camundongos , Ratos , Imuno-Histoquímica , Antígeno Ki-67 , Colágeno Tipo I
11.
ACS Appl Mater Interfaces ; 16(5): 6348-6355, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38288645

RESUMO

The surgical repair of a ruptured tendon faces two major problems: specifically increased fibrous adhesion to the surrounding tissue and inferior mechanical properties of the scar tissue compared to the native tissue. Bacterial attachment to implant materials is an additional problem as it might lead to severe infections and impaired recovery. To counteract adhesion formation, two novel implant materials were fabricated by electrospinning, namely, a random fiber mesh containing hyaluronic acid (HA) and poly(ethylene oxide) (PEO) in a ratio of 1:1 (HA/PEO 1:1) and 1:4 (HA/PEO 1:4), respectively. Electrospun DegraPol (DP) treated with silver nanoparticles (DP-Ag) was developed to counteract the bacterial attachment. The three novel materials were compared to the previously described DP and DP with incorporated insulin-like growth factor-1 (DP-IGF-1), two implant materials that were also designed to improve tendon repair. To test whether the materials are prone to bacterial adhesion and biofilm formation, we assessed 10 strains of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Enterococcus faecalis, known for causing nosocomial infections. Fiber diameter, pore size, and water contact angle, reflecting different degrees of hydrophobicity, were used to characterize all materials. Generally, we observed higher biofilm formation on the more hydrophobic DP as compared to the more hydrophilic DP-IGF-1 and a trend toward reduced biofilm formation for DP treated with silver nanoparticles. For the two HA/PEO implants, a similar biofilm formation was observed. All tested materials were highly prone to bacterial adherence and biofilm formation, pointing toward the need of further material development, including the optimized incorporation of antibacterial agents such as silver nanoparticles or antibiotics.


Assuntos
Nanopartículas Metálicas , Traumatismos dos Tendões , Humanos , Aderência Bacteriana , Prata/farmacologia , Prata/química , Fator de Crescimento Insulin-Like I/farmacologia , Nanopartículas Metálicas/química , Traumatismos dos Tendões/cirurgia , Antibacterianos/farmacologia , Biofilmes , Tendões
12.
Am J Transplant ; 24(1): 104-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37666457

RESUMO

Face transplantation is a viable reconstructive approach for severe craniofacial defects. Despite the evolution witnessed in the field, ethical aspects, clinical and psychosocial implications, public perception, and economic sustainability remain the subject of debate and unanswered questions. Furthermore, poor data reporting and sharing, the absence of standardized metrics for outcome evaluation, and the lack of consensus definitions of success and failure have hampered the development of a "transplantation culture" on a global scale. We completed a 2-round online modified Delphi process with 35 international face transplant stakeholders, including surgeons, clinicians, psychologists, psychiatrists, ethicists, policymakers, and researchers, with a representation of 10 of the 19 face transplant teams that had already performed the procedure and 73% of face transplants. Themes addressed included patient assessment and selection, indications, social support networks, clinical framework, surgical considerations, data on patient progress and outcomes, definitions of success and failure, public image and perception, and financial sustainability. The presented recommendations are the product of a shared commitment of face transplant teams to foster the development of face transplantation and are aimed at providing a gold standard of practice and policy.


Assuntos
Transplante de Face , Alotransplante de Tecidos Compostos Vascularizados , Humanos , Transplante de Face/métodos , Consenso , Técnica Delphi , Projetos de Pesquisa
13.
Acta Histochem ; 126(1): 152127, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38039795

RESUMO

In the oral cavity the tongue is an important muscular organ that supports the swallowing of food and liquids. It is responsible for the sense of taste, based on the many different taste buds it contains. Research in the field of tongue diseases demands for suitable preclinical models. The healthy rabbit tongue may therefore serve as baseline and reference for the pathological situation. With this consideration, we covered the fixation and histological stainings as well as the immunohistochemical labelling of the healthy rabbit tongue. In this technical note, initial choice of the fixative is discussed, with a comparison of formalin fixation and subsequent paraffin embedding versus cryopreservation. Moreover, we delineate the effect of an antigen retrieval step for formalin fixation by several examples. Finally, we provide ECM markers collagen I, collagen III, fibronectin, α-SMA and elastin staining as well as ki67 for proliferative status and PAR-2 protein expression as a marker for inflammatory status and nociception in tongue sections, mainly from the tongue body. Technically, we found superiority of paraffin sections for collagen I, collagen III, fibronectin, ki67 and α-SMA labelling, for selected detections systems. As for ECM components, the lamina propria was very rich in collagen and fibronectin, while the muscular body of the tongue showed only collagen and fibronectin positive areas between the muscle fibers. Moreover, α-SMA was clearly expressed in the walls of arteries and veins. The inflammatory marker PAR-2 on the other hand was prominently expressed in the salivary glands and to some extent in the walls of the vessels. Particular PAR-2 expression was found in the excretory ducts of the tongue. This technical note has the aim to provide baseline images that can be used to compare the pathological state of the diseased rabbit tongue as well as for inter-species comparison, such as mouse or rat tongue. Finally, it can be used for the comparison with the human situation.


Assuntos
Fibronectinas , Língua , Humanos , Coelhos , Animais , Ratos , Camundongos , Imuno-Histoquímica , Fibronectinas/metabolismo , Antígeno Ki-67/metabolismo , Língua/patologia , Colágeno/metabolismo , Formaldeído
14.
Surg Innov ; 31(1): 42-47, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38130173

RESUMO

Background: Robotic systems have successfully been introduced into other surgical fields in the past. First attempts with different setups are made in the field of microsurgery. The Symani® Surgical System, a flexible platform consisting of two robotic arms, features motion scaling with tremor filtration to address the demands and complexity of microsurgery. Symani's NanoWrist Instruments are the world's smallest, wristed surgical instruments, intended to improve a surgeon's range of motion beyond the capability of the human hand. This combination allows surgeons to scale their hand movements while seamlessly articulating the robotic micro instruments. Purpose: We report on our experience in extremity reconstruction with this novel system.Research Design: The Symani Surgical System® was used for 6 cases of extremity reconstruction. The surgeon controlled the manipulators along with the footswitch while either sitting away from the operating table relying on 3D visualization with an exoscope or sitting at the operating table using a standard microscope.Data Collection: Microsurgical anastomoses were performed in 4 patients (3 end-to-end arterial anastomoses and one end-to-side arterial anastomosis) and nerve grafting was performed in 2 patients.Results: Microvascular anastomoses were slower vs conventional microsurgery, but all anastomoses were patent. Epineural coaptation showed proper fascicle alignment and tissue manipulation could be kept to a minimum. The platform's motion scaling allows the surgeon to perform precise micro-movements with only minimal tissue manipulation and hard-to-reach anatomy becomes accessible more easily.Conclusions: Robotic microsurgery might gain importance in the nearer future but more data will need to be collected.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Humanos , Microcirurgia , Anastomose Cirúrgica , Extremidade Superior
15.
Plast Reconstr Surg Glob Open ; 11(12): e5484, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38115836

RESUMO

Advances in the development of robotic systems have recently enabled the use of robotic technology in reconstructive lymphatic surgery. Although the advantages of microsurgical robots must be weighed carefully against the costs, their use may allow for smaller surgical approaches and easier access to anatomically deeper structures or even smaller vessels. We report on a case of a patient with central lymphatic dilation causing abdominal pain and severely reduced physical capacity. Sonography-assisted intranodal injection of indocyanine green allowed for localization of the lymphatic cyst and anastomosis with the left ovarian vein, applying robotic-assisted microsurgery for the first time on the central lymphatic system. Following the successful reconstruction of lymphatic drainage and decompression of the cyst, the patient reported a complete regression of her preoperative symptoms. From a surgical point of view, the Symani Surgical System improved precision and allowed significantly smaller surgical access. Considering the high morbidity and rarity of pathologies of the central lymphatic system, central lymphatic surgery is to date rarely performed. With improved precision and significantly smaller surgical access, robotic-assisted microsurgery has great potential to expand the treatment options for central lymphatic lesions.

16.
Acta Histochem ; 125(7): 152098, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37804548

RESUMO

Situated in the oral cavity, the rabbit palatine tonsils are part of the mucosal immune system and help to defend the body against foreign pathogens. Expressed as two oval protrusions in the wall of the oropharynx, the rabbit palatine tonsils are characterized by excretory ducts and trabeculae. We here compare paraffin embedded and cryosections of the healthy rabbit tonsils. This analysis centers on evaluating the differential outcomes resulting from the application of these fixation methodologies in conjunction with immunohistochemical assays targeting collagen I, collagen III, fibronectin, α-smooth muscle actin (α-SMA), and ki67. Subsequent recommendations are provided based on our findings. Furthermore, we demonstrate the advantage of an antigen retrieval step in immunohistochemical labeling of paraffin sections. Basic classical histological stainings as HE, GT and elastin were also performed. Comparison of different stainings and labelings was furthermore performed in serial sections, showing that adjacent to the excretory ducts, the tonsillar tissue was particularly composed of collagen I and fibronectin, while the vessel walls were predominantly α-SMA positive. Moreover, PAR-2 immunohistochemical staining was performed, where a small fraction of the cells found in the tonsillar connective tissue were PAR-2 positive (probably a subpopulation of mast cells), as well as the lumen of some excretory ducts and trabeculae. Collagen III on the other hand was only weakly expressed in the tonsils. Proliferating ki67 positive cells were rare. This endeavor serves to furnish the scientific community with reference imagery pertinent to researchers opting for the rabbit palatine tonsil model. The diversity of staining techniques employed herein establishes a foundational repository of images, primed for comparative analysis against pathological conditions. Furthermore, these images hold the potential to illustrate inter-species variations. For instance, they can be juxtaposed against murine or rodent tonsils, or even offer insights into the human context.


Assuntos
Fibronectinas , Tonsila Palatina , Humanos , Coelhos , Animais , Camundongos , Tonsila Palatina/química , Imuno-Histoquímica , Antígeno Ki-67 , Parafina/análise , Colágeno
17.
Praxis (Bern 1994) ; 112(10): 507-515, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37855650

RESUMO

INTRODUCTION: This review outlines an overview of up-to-date, stage-appropriate treatment methods for burn injuries as practiced at the National Burn Center of the University Hospital Zurich. It intends to provide practitioners with recommendations for the management of acute minor to severe burn injuries based on scientific evidence as well as the long-term experience of the Burn Center. The focus is on a practical guideline and various options including novel, innovative conceptual approaches.


Assuntos
Queimaduras , Adulto , Humanos , Unidades de Queimados , Queimaduras/terapia
18.
Cancers (Basel) ; 15(17)2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37686671

RESUMO

Benchmarking is crucial for healthcare providers to enhance quality and efficiency, notably for complex conditions like sarcomas. Multidisciplinary teams/sarcoma boards (MDT/SBs) are vital in sarcoma management, but differences in their processes can affect patient outcomes and treatment costs, despite adherence to international guidelines. To address this issue, this study aimed to compare two MDT/SBs and establish an interoperable digital platform, Sarconnector®, for real-time-world data assessment and automated analysis. The study included 983 patients, 46.0% of whom female, with a median age of 58 years, and 4.5% of patients presented with metastasis at diagnosis. Differences were observed in the number of first-time presentations, follow-up presentations, primary sarcomas, biopsies and chemotherapy indications between the two MDT/SB. The results highlight the importance of benchmarking and utilizing a harmonized data approach, such as the RWT approach provided by the Sarconnector®, to standardize and evaluate quality and cost metrics. By identifying areas of improvement and making data-driven decisions on the meta-level, healthcare providers can optimize resources and improve patient outcomes. In conclusion, benchmarking with the RWT harmonized data approach provided by the Sarconnector® can help healthcare providers improve the overall effectiveness of the healthcare system and achieve better outcomes for their patients in terms of both outcomes and costs.

19.
JPRAS Open ; 37: 145-154, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37546233

RESUMO

Micro- and supermicrosurgeries have become standard techniques for lymphatic reconstruction. As increasingly smaller vessels are being targeted, robotic-assisted surgery has emerged as a new approach to push reconstructive limits owing to its ability of motion scaling and providing better accessibility of deep anatomical regions. The precision of the robot is achieved at the expense of operating speed among other variables; therefore, the surgeon must weigh the enhanced dexterity against the additional operating time and cost required for the robotic surgical system itself to ensure optimal resource utilization. Here we present a case series of 8 patients who underwent robot-assisted lymphatic microsurgery for omental flap transfer to the axilla and lympho-venous anastomosis. The Symani® Surgical System was used with a conventional microscope or 3D exoscope. The use of 3D exoscope provided clear benefits in terms of surgeon positioning. Moreover, access to the recipient vessels near the thoracic wall was significantly improved with the robotic setup. In addition, suture precision was excellent, resulting in patent anastomoses. Operating time for anastomosis was comparable to that for manual anastomosis and demonstrated a steep learning curve. The benefits of robotic systems in operating fields with good exposure require further evaluation. However, owing to longer instruments, additional stability, dexterity, and motion precision, robotic systems offer a marked advantage for operating in deep anatomical planes and on small structures. A potentially new field for the implementation of robotic surgery is central lymphatic reconstruction. Progress in terms of operating time and cost is crucial, and future research should validate the effectiveness of robotic-assisted surgery in larger clinical studies.

20.
Plast Reconstr Surg Glob Open ; 11(5): e5020, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37250829

RESUMO

Patients with upper limb lymphedema and lower limb lymphedema experience a wide range of physical and psychological symptoms that affect quality of life. The benefits of lymphatic reconstructive surgery for patients with lymphedema are undisputed. However, recording volume reduction alone may be insufficient with regard to postoperative outcome because measurements are often inadequate, depend on many factors, and do not reflect improvement in quality of life. Methods: We conducted a prospective single center study patients receiving lymphatic reconstructive surgery. Patients received volume measurements preoperatively and at standardized postoperative intervals. To evaluate patient-reported outcomes, patients completed the following questionnaires: LYMPH-Q Upper Extremity Module, quickDASH, SF 36, Lymphoedema Functioning, Disability and Health Questionnaire for Lower Limb Lymphoedema, and Lower Extremity Functional Scale at the aforementioned intervals. Results: We included 55 patients with upper limb lymphedema (24%) and lower limb lymphedema (73%) of lymphedema grades I-III. Patients received lymphovenous anastomosis only (23%), free vascularized lymph node transfer (35%) or a combination of both (42%). Analysis of patient-reported outcome measurements revealed improvements with respect to a broad range of complaints, particularly physical function, symptoms, and psychological well-being. There was no correlation between the extent of volume reduction and improvement in quality of life (Pearson correlation coefficient below ±0.7; P > 0.05). Conclusions: Based on a broad range of outcome measurements, we observed an improved quality of life in almost all patients, even in those without measurable volume loss of the extremity operated on, which emphasizes the need for a standardized use of patient-reported outcome measures to evaluate the benefits of lymphatic reconstructive surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA