RESUMO
BACKGROUND: The mainstay approach in endoscopic eradication therapy (EET) for dysplastic Barrett's esophagus (BE) includes the endoscopic resection of visible lesions, accompanied by ablation of the residual metaplastic epithelium. Cryoablation therapy is one such emerging ablation technique in this field. This systematic review with a meta-analysis aims to accumulate pooled data on cryoablation performance in the treatment of patients with BE and to compare this technique to the standard of care radiofrequency ablation (RFA). METHODS: The MEDLINE, Cochrane, and Scopus databases were searched until June 2024 for studies evaluating BE management using cryoablation for cumulative results. The primary outcome was the complete eradication of dysplasia (CED) and intestinal metaplasia (CEIM) in BE compared to RFA, while secondary outcomes included the respective pooled rates using cryoablation, recurrence, and adverse events, with a separate analysis for strictures. The meta-analyses were based on a random-effects model, and the results were reported as odds ratios (ORs) with 95% confidence intervals (CIs). Subgroup analyses by type of cryoablation were also performed. RESULTS: Twenty-three studies (1604 patients) were finally included, four of which were comparative. CED and CEIM did not differ significantly between cryoablation and RFA [OR= 0.95 (95%CI: 0.50-1.81) and OR = 0.57 (95%CI: 0.20-1.63), respectively)]. The pooled rates of CED, CEIM, and recurrence after cryoablation were 84.2% (95%CI: 79.1-89.3), 64.1% (95%CI: 49.2-79.0), and 8.3% (95%CI: 4.7-11.9), accompanied by high rates of heterogeneity. Adverse events were noted in 14.5% (95%CI: 9.9-19.2) of cases, and 6.5% (95%CI: 4.1-9.0) developed strictures. In the subgroup analysis, the cryoballoon achieved a reduction in heterogeneity in CED, adverse events, and stricture formation, whereas spray catheters provided homogenous results in terms of recurrence. CONCLUSIONS: Cryoablation provides equal outcomes compared to RFA in the treatment of patients with BE, with the cryoballoon achieving relatively homogenous rates of CED and adverse events.
RESUMO
Sedation and analgesia during gastrointestinal (GI) endoscopy increase procedural quality, contributing at the same time to greater patient satisfaction and willingness to undergo the procedure. Although sedation use has been optimized by the advent of efficacious and safe medications, data regarding the minimal criteria for discharge after outpatient endoscopy remain scant. Moreover, the time of discharge after endoscopy can be highly variable, depending not only on the type of procedure and anesthesia administered, but also on postprocedural complications and the patient's comorbidities. To make things even more conflicting, there is neither consensus among various endoscopic societies, concerning the most appropriate discharge strategy, nor a universally established tool that could be incorporated into everyday clinical practice, allowing patients' safe discharge as well as ability to drive. In this context, we conducted a systematic review, aiming to summarize the evidence regarding the available discharge scoring systems after outpatient GI endoscopy with sedation and analgesia administration.
RESUMO
BACKGROUND AND AIMS: Limited evidence exists regarding the impact of glucagon-like peptide-1 receptor agonists (GLP-1RAs) on upper endoscopy. Therefore, a meta-analysis was conducted to comprehensively review the available evidence on this subject. METHODS: A systematic bibliographic search was carried out until May 2024. Pooled estimates were analyzed using a random-effects model, with results presented as odds ratio (OR) and 95% confidence interval (CI). The primary outcome assessed was the rate of retained gastric content (RGC), while secondary outcomes included rates of aborted and repeated procedures, adverse event rate, and rates of aspiration. RESULTS: This analysis included 13 studies involving a total of 84,065 patients. Patients receiving GLP-1RA therapy exhibited significantly higher rates of RGC (OR, 5.56; 95% CI, 3.35 to 9.23), a trend that was consistent among patients with diabetes (OR, 2.60; 95% CI, 2.23 to 3.02). Adjusted analysis, accounting for variables such as sex, age, body mass index, diabetes, and other therapies, confirmed the elevated rates of RGC in the GLP-1RA user group (adjusted OR, 4.20; 95% CI, 3.42 to 5.15). Furthermore, rates of aborted and repeated procedures were higher in the GLP-1RA user group (OR, 5.13; 95% CI, 3.01 to 8.75; and OR, 2.19; 95% CI, 1.43 to 3.35; respectively). However, no significant differences were found in AE and aspiration rates between the 2 groups (OR, 4.04; 95% CI, 0.63 to 26.03; and OR, 1.75; 95% CI, 0.64 to 4.77; respectively). CONCLUSION: Use of GLP-1RAs is associated with increased retention of gastric contents and more frequent aborted procedures during upper endoscopy. However, the adverse event and aspiration rates do not seem different; therefore, adjusting fasting time instead of routinely withholding GLP-1RAs could be reasonable in these patients.
RESUMO
Gastric cancer remains a disease with an ominous prognosis, while early gastric cancer has a good-to-excellent prognosis, with 5-year survival rates of up to 92.6% after successful endoscopic resection. In this context, the accurate identification of patients with established gastric precancerous lesions, namely chronic atrophic gastritis and intestinal metaplasia, is the first step in a stepwise approach to minimize cancer risk. Although current guidelines advocate for the execution of random biopsies to stage the extent and severity of gastritis/intestinal metaplasia, modern biopsy protocols are still imperfect as they have limited reproducibility and are susceptible to sampling error. The advent of novel imaging-enhancing modalities, i.e., high-definition with virtual chromoendoscopy (CE), has revolutionized the inspection of gastric mucosa, leading to an endoscopy-based staging strategy for the management of these premalignant changes in the stomach. Nowadays, the incorporation of CE-targeted biopsies in everyday clinical practice offers not only the robust detection of premalignant lesions but also an improvement in quality, by reducing missed diagnoses along with mean biopsies and, thus, the procedural costs and the environmental footprint. In this review, we summarize the recent evidence regarding the endoscopic grading and sampling of gastric precancerous lesions.
Assuntos
Lesões Pré-Cancerosas , Neoplasias Gástricas , Humanos , Lesões Pré-Cancerosas/patologia , Neoplasias Gástricas/patologia , Biópsia/métodosRESUMO
Immune checkpoint inhibitors and immune-related biomarkers are increasingly investigated in rectal cancer (RC). We retrospectively analysed PD-L1 expression in diagnostic biopsy and resection samples from RC patients treated at our centre between 2000 and 2020. PD-L1 immunostaining (22C3 clone) was evaluated according to tumour proportion (TPS), immune cell (ICS), and the combined positive score (CPS). Eighty-three patients were included. At diagnosis, PD-L1 expression ≥1%/≥5% was observed in 15.4%/0%, 80.7%/37.4%, and 69.2%/25.6% of patients based on TPS, ICS, and CPS, respectively. At surgery, the respective figures were 4.6%/1.5%, 60.2%/32.5%, and 50.7%/26.2%. Using the 1% cut-off and regardless of the scoring system, PD-L1 was less expressed in surgery than biopsy samples (p ≤ 0.04). In paired specimens, PD-L1-ICS reduction was especially observed following neoadjuvant long-course (chemo)radiotherapy (p = 0.03). PD-L1-ICS of ≥5% in surgical samples (HR: 0.17; p = 0.02), and a biopsy-to-surgery increase in PD-L1-ICS (HR: 0.19; p = 0.04) was predictive for longer disease-free survival, while the PD-L1-ICS of either ≥1% (HR 0.28; p = 0.04) or ≥5% (HR 0.19; p = 0.03) in surgical samples and the biopsy-to-surgery increase in PD-L1-ICS (HR: 0.20; p = 0.04) were associated with better overall survival. Our study suggests that PD-L1 expression in RC is largely reflective of immune cell infiltration, and its presence/increase in surgical samples predicts better outcomes.
RESUMO
Background: Stent selection in the endoscopic management of post-liver-transplant anastomotic biliary strictures remains controversial. This systematic review and meta-analysis aimed to evaluate the potential differences between available stents. Methods: MEDLINE, Cochrane, and Scopus databases were searched until April 2023 for comparative studies evaluating stricture management using multiple plastic stents (MPS) and self-expandable metal stents (SEMS), including fully-covered (FC)- and intraductal (ID)-SEMS. The primary outcome was stricture resolution, while secondary outcomes included stricture recurrence, stent migration and adverse events. Meta-analyses were based on a random-effects model and the results were reported as odds ratios (OR) with 95% confidence intervals (CI). Subgroup analyses by type of metal stent and a cost-effectiveness analysis were also performed. Results: Nine studies (687 patients) were finally included. Considering stricture resolution, SEMS and MPS did not differ significantly (OR 0.99, 95%CI 0.48-2.01; I 2=35%). Stricture recurrence, migration rates and adverse events were also comparable (OR 1.71, 95%CI 0.87-3.38; I 2=55%, OR 0.73, 95%CI 0.32-1.68; I 2=56%, and OR 1.47, 95%CI 0.89-2.43; I 2=24%, respectively). In the subgroup analysis, stricture resolution and recurrence rates did not differ for ID-SEMS vs. MPS or FC-SEMS vs. MPS. Migration rates were lower for ID-SEMS compared to MPS (OR 0.28, 95%CI 0.11-0.70; I 2=0%), and complication rates were higher after FC-SEMS compared to MPS (OR 1.76, 95%CI 1.06-2.93; I 2=0%). Finally, ID-SEMS were the most cost-effective approach, with the lowest incremental cost-effectiveness ratio: 3447.6 £/QALY. Conclusion: Stent type did not affect stricture resolution and recurrence; however, ID-SEMS placement was the most cost-effective approach compared to the alternatives.
RESUMO
INTRODUCTION: Endoscopic retrograde pancreatography (ERP) has traditionally been the standard modality for pancreatic endotherapy. However, in certain situations, failure of retrograde ductal access may warrant an alternative modality of drainage. This can occur in various settings like difficult and/or surgically altered anatomy or duodenal obstruction. Endoscopic ultrasound-guided pancreatic duct drainage (EUS-PDD) is a relatively newer addition to the armamentarium for endoscopic access to the PD. AREAS COVERED: This comprehensive state-of-art review aims to give an overview of the indications, technical details, different approaches, and outcomes of EUS-PDD, with the latest evidence available in scientific literature. EXPERT OPINION: Akin to its biliary drainage counterpart, EUS-PDD enables an EUS-assisted-ERP using rendezvous technique or EUS-guided drainage through transmural stenting. The technique has evolved over the ensuing years with multitude of accessories, approaches, and devices to optimize the outcomes. However, the technical success and adverse events rates need to be further improved. Additionally, it has a steep learning curve with requirements of advanced technical skill and optimum infrastructure back-up. Meticulous patient selection, precise knowledge of ductal anatomy, appropriate approach, and carefully chosen accessories can improve its clinical outcomes.
Assuntos
Drenagem , Endossonografia , Ductos Pancreáticos , Stents , Ultrassonografia de Intervenção , Humanos , Drenagem/métodos , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/cirurgia , Endossonografia/métodos , Ultrassonografia de Intervenção/métodos , Pancreatopatias/cirurgia , Pancreatopatias/diagnóstico por imagem , Pancreatopatias/terapia , Resultado do TratamentoRESUMO
BACKGROUND: The efficacy of endoscopic ultrasound-guided liver biopsy (EUS-LB) compared to percutaneous liver biopsy (PC-LB) remains uncertain. METHODS: Our data consist of randomized controlled trials (RCTs) comparing EUS-LB to PC-LB, found through a literature search via PubMed/Medline and Embase. The primary outcome was sample adequacy, whereas secondary outcomes were longest and total lengths of tissue specimens, diagnostic accuracy, and number of complete portal tracts (CPTs). RESULTS: Sample adequacy did not significantly differ between EUS-LB and PC-LB (risk ratio [RR] 1.18; 95% confidence interval [CI] 0.58-2.38; p = 0.65), with very low evidence quality and inadequate sample size as per trial sequential analysis (TSA). The two techniques were equivalent with respect to diagnostic accuracy (RR: 1; CI: 0.95-1.05; p = 0.88), mean number of complete portal tracts (mean difference: 2.29, -4.08 to 8.66; p = 0.48), and total specimen length (mean difference: -0.51, -20.92 to 19.9; p = 0.96). The mean maximum specimen length was significantly longer in the PC-LB group (mean difference: -3.11, -5.51 to -0.71; p = 0.01), and TSA showed that the required information size was reached. CONCLUSION: EUS-LB and PC-LB are comparable in terms of diagnostic performance although PC-LB provides longer non-fragmented specimens.
RESUMO
Background: Percutaneous cholangioscopy (PerC) offers an alternative for patients with an inaccessible biliary tree. This systematic review and meta-analysis aimed to evaluate the performance of this technique. Methods: A search in Medline, Cochrane and ClinicalTrials.gov databases was performed for studies assessing PerC up to October 2022. The primary outcome was diagnostic success, defined as successful stone identification or stricture workup. Secondary outcomes included therapeutic success (stone extraction, stenting) and complication rate. A subgroup analysis compared previous-generation and modern cholangioscopes. We performed meta-analyses using a random-effects model and the results were reported as percentages with 95% confidence interval (CI). Results: Fourteen studies (682 patients) were eligible for analysis. The rate of diagnostic success was 98.7% (95%CI 97.6-99.8%; I2=31.19%) and therapeutic success was 88.6% (95%CI 82.8-94.3%; I2=74.92%). Adverse events were recorded in 17.1% (95%CI 10.7-23.5%; I2=77.56%), of which 15.9% (95%CI 9.8-21.9%; I2=75.98%) were minor and 0.6% (95%CI 0.1-1.2%; I2=0%) major. The Spyglass system showed null heterogeneity for all outcomes; compared with older-generation endoscopes it offered comparable diagnostic success, but yielded significantly superior therapeutic success (96.1%, 95%CI 90-100%; I2=0% vs. 86.4%, 95%CI 79.2-93.6%; I2=81.41%; P=0.02]. Conclusion: PerC, especially using currently available cholangioscopes, is associated with high diagnostic and therapeutic success.
RESUMO
Gastric outlet obstruction (GOO) poses a common and challenging clinical scenario, characterized by mechanical blockage in the pylorus, distal stomach, or duodenum, resulting in symptoms such as nausea, vomiting, abdominal pain, and early satiety. Its diverse etiology encompasses both benign and malignant disorders. The spectrum of current treatment modalities extends from conservative approaches to more invasive interventions, incorporating procedures like surgical gastroenterostomy (SGE), self-expandable metallic stents (SEMSs) placement, and the advanced technique of endoscopic ultrasound-guided gastroenterostomy (EUS-GE). While surgery is favored for longer life expectancy, stents are preferred in malignant gastric outlet stenosis. The novel EUS-GE technique, employing a lumen-apposing self-expandable metal stent (LAMS), combines the immediate efficacy of stents with the enduring benefits of gastroenterostomy. Despite its promising outcomes, EUS-GE is a technically demanding procedure requiring specialized expertise and facilities.
Assuntos
Obstrução da Saída Gástrica , Gastroenterostomia , Humanos , Gastroenterostomia/efeitos adversos , Gastroenterostomia/métodos , Endossonografia/efeitos adversos , Endossonografia/métodos , Obstrução da Saída Gástrica/diagnóstico por imagem , Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/cirurgia , Piloro/cirurgia , Stents/efeitos adversos , Constrição Patológica/complicações , Constrição Patológica/cirurgiaRESUMO
Choledocholithiasis is one of the most common indications for endoscopic retrograde cholangiopancreatography (ERCP) in daily practice. Although the majority of stones are small and can be easily removed in a single endoscopy session, approximately 10-15% of patients have complex biliary stones, requiring additional procedures for an optimum clinical outcome. A plethora of endoscopic methods is available for the removal of difficult biliary stones, including papillary large balloon dilation, mechanical lithotripsy, and electrohydraulic and laser lithotripsy. In-depth knowledge of these techniques and the emerging literature on them is required to yield the most optimal therapeutic effects. This narrative review aims to describe the definition of difficult bile duct stones based on certain characteristics and streamline their endoscopic retrieval using various modalities to achieve higher clearance rates.
Assuntos
Coledocolitíase , Cálculos Biliares , Humanos , Resultado do Tratamento , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cálculos Biliares/cirurgia , Cateterismo/métodos , Coledocolitíase/cirurgiaRESUMO
BACKGROUND: There is limited evidence on the comparative diagnostic performance of endoscopic tissue sampling techniques for subepithelial lesions. We performed a systematic review with network meta-analysis to compare these techniques. METHODS: A systematic literature review was conducted for randomized controlled trials (RCTs) comparing the sample adequacy and diagnostic accuracy of bite-on-bite biopsy, mucosal incision-assisted biopsy (MIAB), endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), and EUS-guided fine-needle biopsy (FNB). Results were expressed as relative risk (RR) and 95%CI. RESULTS: Eight RCTs were identified. EUS-FNB was significantly superior to EUS-FNA in terms of sample adequacy (RR 1.20 [95%CI 1.05-1.45]), whereas none of the other techniques significantly outperformed EUS-FNA. Additionally, bite-on-bite biopsy was significantly inferior to EUS-FNB (RR 0.55 [95%CI 0.33-0.98]). Overall, EUS-FNB appeared to be the best technique (surface under cumulative ranking [SUCRA] score 0.90) followed by MIAB (SUCRA 0.83), whereas bite-on-bite biopsy showed the poorest performance. When considering lesions <20 mm, MIAB, but not EUS-FNB, showed significantly higher accuracy rates compared with EUS-FNA (RR 1.68 [95%CI 1.02-2.88]). Overall, MIAB ranked as the best intervention for lesions <20 mm (SUCRA score 0.86 for adequacy and 0.91 for accuracy), with EUS-FNB only slightly superior to EUS-FNA. When rapid on-site cytological evaluation (ROSE) was available, no difference between EUS-FNB, EUS-FNA, and MIAB was observed. CONCLUSION: EUS-FNB and MIAB appeared to provide better performance, whereas bite-on-bite sampling was significantly inferior to the other techniques. MIAB seemed to be the best option for smaller lesions, whereas EUS-FNA remained competitive when ROSE was available.
Assuntos
Neoplasias Pancreáticas , Ferida Cirúrgica , Trato Gastrointestinal Superior , Humanos , Metanálise em Rede , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endoscopia , Trato Gastrointestinal Superior/patologia , Neoplasias Pancreáticas/patologiaRESUMO
BACKGROUND: Esophageal stenting is an important intervention for managing malignant and benign dysphagia, with stent migration representing a common drawback. This systematic review with meta-analysis aimed to assess the benefit of stent fixation over nonfixation. METHODS: A systematic search was performed in MEDLINE, Cochrane, Scopus, and ClinicalTrials.gov databases until January 2023 for comparative studies evaluating the migration rates of esophageal stents with versus without (control) fixation. The primary outcome was migration rate. Secondary outcomes included adverse event rate. A subgroup analysis stratified the results based on different fixation techniques: suturing, over-the-scope (OTS) clipping, and through-the-scope (TTS) clipping. Meta-analysis was based on a random effects model and the results were reported as odds ratios (ORs) with 95â%CIs. RESULTS: 10 studies (1014 patients) were included. The rate of stent migration was significantly lower after fixation (OR 0.20, 95â%CI 0.11-0.37; I2 â=â59â%, Pâ=â0.01). The adverse event rate was similar between fixation and control groups (OR 0.65, 95â%CI 0.28-1.52; I2 â=â55â%, Pâ=â0.06). In the subgroup analysis, all fixation techniques remained superior to nonfixation of stents (suturing OR 0.23, 95â%CI 0.10-0.53; OTS clips OR 0.31, 95â%CI 0.17-0.58; TTS clips OR 0.10, 95â%CI 0.03-0.38); however, only the OTS and TTS clip groups achieved nonsignificant heterogeneity (I2 â=â0â%, Pâ=â0.67 and Pâ=â0.73, respectively). No difference between techniques was recorded for migration rates. CONCLUSION: Esophageal stent fixation was associated with significantly lower migration rates compared with nonfixation of stents, regardless of fixation technique and stenting indication.
Assuntos
Transtornos de Deglutição , Stents , Humanos , Stents/efeitos adversos , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/cirurgia , Resultado do TratamentoRESUMO
BACKGROUND: Mirroring the experience with colonic resections, cold snare-based techniques have been recently proposed for non-ampullary duodenal lesions to reduce the risk of adverse events (AEs). As the duodenal wall is thinner and more vascularized than in the colon, electrocautery-related AEs are relevant issues in this setting. AIMS: We performed a systematic review with pooled-analysis to evaluate the efficacy and safety of this technique. METHODS: Electronic databases (Medline, Scopus, EMBASE) were searched up to January 2023. Full articles including patients with duodenal lesions resected by cold-snare technique were eligible. The adverse events (i.e., bleeding, perforation, stricture), complete resection, and recurrence rates were pooled using a random model. RESULTS: Eleven studies were eligible, providing data on 3137 lesions removed from 233 patients. The overall AE rate for cold snaring was 0.25% (95% CI, 0.19%-0.69%). Among the three studies comparing cold- and hot-snare approaches, procedure-related bleeding rate was significantly lower with cold approach (OR 1.21, 0.51-2.85; p = 0.66). The complete resection rate was 99.40% (95% CI, 98.60%-100%), with a residual/recurrence rate of 12.95% (95% CI, 4.75%-21.16%). On univariate meta-regression, lesion size significantly affected both the adverse events and recurrence risk. CONCLUSION: Cold-snare resection appears effective and extremely safe for resecting non-ampullary duodenal lesions.
Assuntos
Adenoma , Pólipos do Colo , Ressecção Endoscópica de Mucosa , Humanos , Pólipos do Colo/patologia , Colonoscopia/métodos , Adenoma/cirurgia , Adenoma/patologia , Duodeno/cirurgia , Duodeno/patologia , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Resultado do TratamentoRESUMO
BACKGROUND: Single use duodenoscopes were developed to reduce the risk of infection transmission from contaminated reusable duodenoscopes. To this end, we examined various biliary interventions using single use duodenoscopes in patients undergoing endoscopic retrograde cholangiopancreatography (ERCP). METHODS: Medline, Embase, Scopus, and Cochrane databases were searched from inception through Aug 2022 to identify studies reporting on the performance of single use duodenoscopes for ERCP. RESULTS: Seven articles were included in the final analysis that included 642 patients (318 males). The Exalt Model D duodenoscope was used in most cases (88.8%) followed by the aScope Duodeno (11.2%) for ERCP. Most ERCPs had a complexity grade of 2 (n = 303) and 3 (n = 198). The pooled cumulative rate of successful cannulation was 95% (95% Confidence Interval (CI): 93-96%, I2=0%, P = 0.46). Sphincterotomy was successfully performed in all cases. The pooled cumulative rate of PEP was 2% (95% CI: 0.4-3.4%, I2=0%, P = 0.80). The pooled cumulative rate of total adverse events was 7% (95% CI: 4-10%, I2=47%, P = 0.08). CONCLUSIONS: The results of this systematic review and meta-analysis show that single use duodenoscopes are associated with high cannulation rates, technical performance, and safety profile.
Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Duodenoscópios , Masculino , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Cateterismo/métodosRESUMO
Predictive models (PMs) in endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic ultrasound (EUS) have the potential to improve patient outcomes, enhance diagnostic accuracy, and guide therapeutic interventions. This review aims to summarize the current state of predictive models in ERCP and EUS and their clinical implications. To be considered useful in clinical practice a PM should be accurate, easy to perform, and may consider objective variables. PMs in ERCP estimate correct indication, probability of success, and the risk of developing adverse events. These models incorporate patient-related factors and technical aspects of the procedure. In the field of EUS, these models utilize clinical and imaging data to predict the likelihood of malignancy, presence of specific lesions, or risk of complications related to therapeutic interventions. Further research, validation, and refinement are necessary to maximize the utility and impact of these models in routine clinical practice.
Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Endossonografia , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Endossonografia/efeitos adversos , Endossonografia/métodosRESUMO
Adequate bowel preparation is of paramount importance for the effectiveness of preventive colonoscopy as it allows visualization of the mucosal surface and adenomas detection, the pre-malignant lesions leading to colon cancer. Still, a considerable portion of patients fail to achieve adequate bowel cleansing, with predictors of inadequate bowel preparation being at the focal point of several studies, so far. Incorporation of these factors within predictive models has been implemented in an effort to promptly identify patients at risk for inadequate bowel preparation and thus, timely adopt practices that have the potential to improve bowel cleansing. Ultimately, this could lead to improved procedural outcomes not only in terms of neoplastic detection rate but also interval repeat procedures, expenses, patient convenience and adverse events risk. Aim of this manuscript is to present an up to date overview of all predictive scores/models addressing bowel cleansing adequacy in everyday clinical practice.
Assuntos
Adenoma , Colonoscopia , Humanos , Colonoscopia/efeitos adversos , Colonoscopia/métodos , PolietilenoglicóisRESUMO
Background: Add-on devices with projections, e.g., Endocuff, Endocuff Vision, EndoRings, and Wingcap, placed on the distal tip of the colonoscope promise to improve the detection of precancerous lesions. We performed a meta-analysis to evaluate the performance of these devices exclusively among individuals undergoing colonoscopy for screening purpose. Methods: A computerized literature search was performed across MEDLINE and Cochrane Library databases for randomized controlled trials that compared standard colonoscopy (SC) to procedures using add-on devices. The primary outcome was adenoma detection rate (ADR), while secondary outcomes included polyp detection rate (PDR), advanced ADR (AADR), and sessile serrated lesion detection rate (SSLDR). The effect size on study outcomes was calculated using a random-effects model and presented as the risk ratio (RR) and 95% confidence interval (CI). Results: Seven studies enrolling a total of 5785 patients were included. The use of add-on-devices with projections was associated with a higher ADR compared to SC: 45.9% vs. 41.1%; RR 1.18, 95%CI 1.02-1.37; P=0.03; I2=79%. Although PDR was higher in screening colonoscopies assisted by add-on devices as compared to SC, the difference failed to reach significance: 55.1% vs. 50.8%; RR 1.10, 95%CI 0.96-1.26; P=0.17; I2=75%. No difference was found between procedures assisted by add-on devices with projections and SC colonoscopies in terms of AADR (18.5% vs. 17.6%; RR 1.00, 95%CI 0.79-1.27; P=0.98; I2=56%) or SSLDR (6.8% vs. 5.8%; RR 1.17, 95%CI 0.95-1.44; P=0.15; I2=0%). Conclusion: Colonoscopy assisted by add-on devices with projections achieves a better ADR compared to SC among individuals undergoing screening for bowel cancer.
RESUMO
Background: Multidisciplinary team (MDT) meetings aim to optimize patient management. We evaluated the impact of MDT discussions on the management and diagnosis of focal pancreatic lesions in a single tertiary center. Methods: All patients with an initial diagnosis of solid or cystic pancreatic lesion discussed in our institution's MDT meeting on pancreatic diseases between January 1, 2020, and December 31, 2021, were included. The impact of MDT discussion on patient management, defined as a modification of the initially proposed therapeutic plan after MDT discussion, as well as the criteria leading to this modification, were the primary outcomes. Impact on diagnosis was the secondary outcome. Results: A total of 522 patients were included. Of these, 185 (35.4%) and 337 (64.6%) had an initial diagnosis of cystic or solid lesion, respectively. The most common referral query was regarding the management plan (349/522; 66.9%). Endoscopy was the procedure most often proposed before MDT discussion (109/522; 20.9%). Overall, the MDT discussion led to modification of the management plan in 377/522 patients (72.2%), with a statistically significant difference between cystic and solid lesions (63.2% vs. 77.2%; P<0.001). Management modifications were mainly driven by revision of cross-sectional radiological images. MDT discussion led to modification of the diagnosis in 92/522 patients (17.6%), with a significant difference regarding cystic lesions (35.7% vs. 7.7%; P<0.001). Conclusion: MDT discussion impacts the management of patients with cystic and solid pancreatic lesions, leading to a modification of the initially proposed management in two-thirds of them, mainly through revision of cross-sectional imaging.