Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Radiat Prot Dosimetry ; 190(2): 125-131, 2020 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-32607545

RESUMO

A set of five Bonner spheres was used to measure the ambient neutron H*(10) dose around an orphan 241Am-Be neutron source shielded with different arrangements and types of neutron-absorbing materials. These results were compared to measurements obtained using a portable radiation dosemeter. The Bonner sphere measurement results identified the presence of a large thermal and intermediate neutron component from the shielded 241Am-Be source that was not revealed using the portable instrument.


Assuntos
Amerício , Exposição Ocupacional , Desenho de Equipamento , Nêutrons , Exposição Ocupacional/análise , Doses de Radiação , Análise Espectral
3.
Integr Biol (Camb) ; 11(8): 331-341, 2019 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-31724717

RESUMO

Type 1 diabetes (T1D) results from the autoimmune destruction of ß-cells within the pancreatic islets of Langerhans. Clinical islet transplantation from healthy donors is proposed to ameliorate symptoms, improve quality of life, and enhance the life span of afflicted T1D patients. However, post-transplant outcomes are dependent on the survival of the transplanted islets, which relies on the engraftment of the islets with the recipient's vasculature among other factors. Treatment strategies to improve engraftment include combining islets with supporting cells including endothelial cells (EC) and mesenchymal stem cells (MSC), dynamic cells capable of robust immunomodulatory and vasculogenic effects. In this study, we developed an in vitro model of transplantation to investigate the cellular mechanisms that enhance rapid vascularization of heterotopic islet constructs. Self-assembled vascular beds of fluorescently stained EC served as reproducible in vitro transplantation sites. Heterotopic islet constructs composed of islets, EC, and MSC were transferred to vascular beds for modeling transplantation. Time-lapsed imaging was performed for analysis of the vascular bed remodeling for parameters of neo-vascularization. Moreover, sampling of media following modeled transplantation showed secretory profiles that were correlated with imaging analyses as well as with islet function using glucose-stimulated insulin secretion. Together, evidence revealed that heterotopic constructs consisting of islets, EC, and MSC exhibited the most rapid recruitment and robust branching of cells from the vascular beds suggesting enhanced neo-vascularization compared to islets alone and control constructs. Together, this evidence supports a promising cell transplantation strategy for T1D and also demonstrates a valuable tool for rapidly investigating candidate cellular therapies for transplantation.


Assuntos
Diabetes Mellitus Tipo 1/terapia , Transplante das Ilhotas Pancreáticas/instrumentação , Transplante das Ilhotas Pancreáticas/métodos , Ilhotas Pancreáticas/irrigação sanguínea , Ilhotas Pancreáticas/citologia , Transplante de Células-Tronco Mesenquimais , Células da Medula Óssea/citologia , Técnicas de Cultura de Células , Células Endoteliais/citologia , Glucose/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Insulina/metabolismo , Secreção de Insulina , Microscopia Confocal , Neovascularização Fisiológica , Regiões Promotoras Genéticas , Fatores de Tempo
5.
Health Phys ; 108(1): 67-75, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25437522

RESUMO

Radioactive material deposited in multiple organs of the body is likely to confound a result of an in vivo measurement performed over the lungs, the most frequently monitored organ for occupational exposure. The significance of this interference was evaluated by measuring anthropometric torso phantoms containing lungs, liver, skeleton, and axillary lymph nodes, each with a precisely known quantity of 241Am uniformly distributed in the organs. Arrays of multiple high-resolution germanium detectors were positioned over organs within the torso phantom containing 241Am or over proximal organs without activity to determine the degree of measurement confounding due to photons emitted from other source organs. A set of four mathematical response functions describes the measured count rate with detectors positioned over each of the relevant organs and 241Am contained in the measured organ or one of the other organs selected as a confounder. Simultaneous solution of these equations by matrix algebra, where the diagonal terms of the matrix are calibration factors for a direct measurement of activity in an organ and the off-diagonal terms reflect the contribution (i.e., interference or cross-talk) produced by 241Am in a confounding organ, yields the activity deposited in each of the relevant organs. The matrix solution described in this paper represents a method for adjusting a result of 241Am measured directly in one organ for interferences that may arise from 241Am deposited elsewhere and represents a technically valid procedure to aid in evaluating internal dose based upon in vivo measurements for those radioactive materials known to deposit in multiple organs.


Assuntos
Amerício/análise , Pulmão/efeitos da radiação , Contagem Corporal Total/métodos , Amerício/efeitos adversos , Osso e Ossos/química , Osso e Ossos/efeitos da radiação , Humanos , Fígado/química , Fígado/efeitos da radiação , Pulmão/química , Linfonodos/química , Linfonodos/efeitos da radiação , Exposição Ocupacional/estatística & dados numéricos , Especificidade de Órgãos , Imagens de Fantasmas , Monitoramento de Radiação/métodos , Monitoramento de Radiação/estatística & dados numéricos , Liberação Nociva de Radioativos , Crânio/química , Crânio/efeitos da radiação , Contagem Corporal Total/estatística & dados numéricos
6.
Health Phys ; 103(3): 279-85, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22850233

RESUMO

The detection efficiency and interference susceptibility of four different types of low energy photon detectors, each with a unique geometric arrangement, were compared for direct measurement of Am deposited in the axillary lymph nodes. Although the most efficient detector was a single large 23,226 mm square phoswich detector, it was also the most susceptible to confounding depositions from activity deposited in adjacent organs. The array of two 2,800 mm high purity germanium detectors exhibited the highest efficiency per unit detector area with some resistance to confounding from activity deposited in the lungs. The array of two 4,560 mm NaI(Tl) detectors was the least susceptible to confounding and nearly as efficient per square millimeter as the high purity germanium detector array. Thus, selection of a detector system for in vivo measurement of activity deposited in the axillary lymph nodes should consider whether there is a likelihood for activity deposited in other organs, such as the lungs, skeleton, or liver, to create an interference that will confound the measurement result.


Assuntos
Amerício/análise , Linfonodos/química , Radiometria/instrumentação , Artefatos , Pulmão/química , Imagens de Fantasmas , Fótons , Incerteza
7.
Int J Oncol ; 40(6): 1881-8, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22322558

RESUMO

The purpose of this study was to determine therapeutic effects and systemic toxicity of 212Pb-trastuzumab in an orthotopic model of human prostate cancer cells in nude mice. TCMC-Trastuzumab was radiolabeled with 212Pb. The 212Pb-trastuzumab generated from the procedure was intact and had high binding affinity with a dissociation constant (of 3.9±0.99 nM. PC-3MM2 cells, which expressed a lower level of HER2 both in culture and in tumors, were used in therapy studies. A single intravenous injection of 212Pb-trastuzumab reduced tumor growth by 60-80%, reduced aortic lymph node metastasis, and prolonged the survival of tumor-bearing mice. Treatment with 212Pb-trastuzumab did not cause significant changes in body weight, serum glutamic pyruvic transaminase (SGPT), blood urea nitrogen (BUN), hematological profiles, and histological morphology of several major organs of tumor-bearing mice. These findings suggest that a systemic delivery of 212Pb-trastuzumab could be an effective modality for management of advanced human prostate cancer.


Assuntos
Androgênios/fisiologia , Anticorpos Monoclonais Humanizados/uso terapêutico , Radioisótopos de Chumbo/uso terapêutico , Transferência Linear de Energia , Neoplasias da Próstata/radioterapia , Radioimunoterapia , Animais , Linhagem Celular Tumoral , Receptores ErbB/metabolismo , Humanos , Masculino , Camundongos , Camundongos Nus , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Receptor ErbB-2/metabolismo , Trastuzumab , Carga Tumoral/efeitos da radiação , Ensaios Antitumorais Modelo de Xenoenxerto
9.
Health Phys ; 99(1): 26-38, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20539122

RESUMO

Neutron and photon radiation survey records have been used to evaluate and develop a neutron to photon (NP) ratio to reconstruct neutron doses to workers around Hanford's single pass reactors that operated from 1945 to 1972. A total of 5,773 paired neutron and photon measurements extracted from 57 boxes of survey records were used in the development of the NP ratio. The development of the NP ratio enables the use of the recorded dose from an individual's photon dosimeter badge to be used to estimate the unmonitored neutron dose. The Pearson rank correlation between the neutron and photon measurements was 0.71. The NP ratio best fit a lognormal distribution with a geometric mean (GM) of 0.8, a geometric standard deviation (GSD) of 2.95, and the upper 95 th % of this distribution was 4.75. An estimate of the neutron dose based on this NP ratio is considered bounding due to evidence that up to 70% of the total photon exposure received by workers around the single pass reactors occurs during shutdown maintenance and refueling activities when there is no significant neutron exposure. Thus when this NP ratio is applied to the total measured photon dose from an individual film badge dosimeter, the resulting neutron dose is considered bounded.


Assuntos
Monitoramento Ambiental , Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Doses de Radiação , Coleta de Dados , Geografia , Humanos , Masculino , Modelos Estatísticos , Exposição Ocupacional/efeitos adversos , Medição de Risco , Fatores de Tempo
10.
Health Phys ; 97(3): 219-27, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19667805

RESUMO

A calibration phantom was developed at the University of Cincinnati (UC) to determine detection efficiency and estimate the quantity of activity deposited in the axillary lymph nodes of a worker who had unknowingly sustained a wound contaminated with 241Am at some distant time in the past. This paper describes how the Livermore Torso Phantom was modified for calibrating direct, in vivo measurements of 241Am deposited in the axillary lymph nodes. Modifications involved milling a pair of parallel, flat bottom, cylindrical holes into the left and right shoulders (below the humeral head) of the Livermore Torso Phantom in which solid, 1.40-cm-diameter cylindrical rods were inserted. Each rod was fabricated using a muscle tissue substitute. One end of each rod contained a precisely known quantity of Am sealed in a 1-cm-diameter, 2.54-cm-deep well to simulate the axillary lymph nodes when inserted into the modified Livermore Torso Phantom. The fixed locations for the axillary lymph nodes in the phantom were determined according to the position of the Level I and the combined Level II + III axillary lymph nodes reported in the literature. Discrete calibration measurements for 241Am in the simulated axillary lymph nodes located in the right and left sides of the thorax were performed using pairs of high-resolution germanium detectors at UC and Lawrence Livermore National Laboratory. The percent efficiency for measuring the 59.5 keV photon from Am deposited in the right and left axillary lymph nodes using a pair of 3,000 mm2 detectors is 2.60 +/- 0.03 counts gamma-1 and 5.45 +/- 0.07 counts gamma-1, respectively. Activity deposited in the right and left axillary lymph nodes was found to contribute 12.5% and 19.7%, respectively, to a lung measurement and 1.2% and 0.2%, respectively, to a liver measurement. Thus, radioactive material mobilized from a wound in a finger or hand and deposited in the axillary lymph nodes has been shown to confound results of a direct, in vivo measurement of the lungs.


Assuntos
Amerício/análise , Linfonodos/efeitos da radiação , Imagens de Fantasmas , Amerício/efeitos adversos , Amerício/farmacocinética , Axila , Humanos , Fígado/efeitos da radiação , Pulmão/efeitos da radiação , Exposição Ocupacional , Imagens de Fantasmas/estatística & dados numéricos , Doses de Radiação , Monitoramento de Radiação
11.
J Environ Monit ; 11(5): 1037-42, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19436862

RESUMO

Millions of children attending US schools are exposed to traffic-related air pollutants, including health-relevant ultrafine aerosols generated from school buses powered with diesel fuel. This case study was established in a midwestern (USA) metropolitan area to determine the concentration and elemental composition of aerosol in the vicinity of a public school during morning hours when the bus traffic in and out of the adjacent depot was especially intense. Simultaneous measurements were performed at a control site. The ambient aerosol was first characterized in real time using a particle size selective aerosol spectrometer and then continuously monitored at each site with a real-time non-size-selective instrument that detected particles of 20 nm to >1 microm. In addition, air samples were collected with PM2.5 Harvard Impactors and analyzed for elemental composition using the X-ray fluorescence technique (for 38 elements) and thermal-optical transmittance (for carbon). The measurements were conducted during two seasons: in March at ambient temperature around 0 degrees C and in May when it ranged mostly between 10 and 20 degrees C. The particle number concentration at the test site exhibited high temporal variability while it was time independent at the control site. Overall, the aerosol particle count at the school was 4.7 +/- 1.0 times (March) and 2.2 +/- 0.4 times (May) greater than at the control site. On some days, a 15 min-averaged particle number concentration showed significant correlation with the number of school bus arrivals and departures during these time intervals. On other days, the correlation was less than statistically significant. The 3 h time-averaged particle concentrations determined in the test site on days when the school buses operated were found to be more than two-fold greater (on average) than those measured on bus-free days at the same location, and this difference was statistically significant. Overall, the data suggest a possible association between the number of detected aerosol particles and the school bus traffic intensity. Analysis of the filter samples collected at the school site between 6:00 and 9:00 AM revealed higher concentrations of elemental carbon as compared to the control site (2.8 +/- 0.9 times in March and 3.1 +/- 1.1 times in May). The data collected in this case study suggest that school buses significantly contribute to exposure of children to aerosol pollutants (including diesel exhaust particles) in the school vicinity.


Assuntos
Poluentes Atmosféricos/análise , Veículos Automotores , Instituições Acadêmicas , Emissões de Veículos , Criança , Exposição Ambiental , Fluorescência , Humanos , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA