1.
Phys Med ; 85: 98-106, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33991807

RESUMO

PURPOSE: The purpose of this multicenter phantom study was to exploit an innovative approach, based on an extensive acquisition protocol and unsupervised clustering analysis, in order to assess any potential bias in apparent diffusion coefficient (ADC) estimation due to different scanner characteristics. Moreover, we aimed at assessing, for the first time, any effect of acquisition plan/phase encoding direction on ADC estimation. METHODS: Water phantom acquisitions were carried out on 39 scanners. DWI acquisitions (b-value = 0-200-400-600-800-1000 s/mm2) with different acquisition plans (axial, coronal, sagittal) and phase encoding directions (anterior/posterior and right/left, for the axial acquisition plan), for 3 orthogonal diffusion weighting gradient directions, were performed. For each acquisition setup, ADC values were measured in-center and off-center (6 different positions), resulting in an entire dataset of 84 × 39 = 3276 ADC values. Spatial uniformity of ADC maps was assessed by means of the percentage difference between off-center and in-center ADC values (Δ). RESULTS: No significant dependence of in-center ADC values on acquisition plan/phase encoding direction was found. Ward unsupervised clustering analysis showed 3 distinct clusters of scanners and an association between Δ-values and manufacturer/model, whereas no association between Δ-values and maximum gradient strength, slew rate or static magnetic field strength was revealed. Several acquisition setups showed significant differences among groups, indicating the introduction of different biases in ADC estimation. CONCLUSIONS: Unsupervised clustering analysis of DWI data, obtained from several scanners using an extensive acquisition protocol, allows to reveal an association between measured ADC values and manufacturer/model of scanner, as well as to identify suboptimal DWI acquisition setups for accurate ADC estimation.


Assuntos
Imagem de Difusão por Ressonância Magnética , Análise por Conglomerados , Difusão , Imagens de Fantasmas , Reprodutibilidade dos Testes
2.
Phys Med ; 54: 49-55, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337010

RESUMO

PURPOSE: The aim of this study was to propose and validate across various clinical scanner systems a straightforward multiparametric quality assurance procedure for proton magnetic resonance spectroscopy (MRS). METHODS: Eighteen clinical 1.5 T and 3 T scanner systems for MRS, from 16 centres and 3 different manufacturers, were enrolled in the study. A standard spherical water phantom was employed by all centres. The acquisition protocol included 3 sets of single (isotropic) voxel (size 20 mm) PRESS acquisitions with unsuppressed water signal and acquisition voxel position at isocenter as well as off-center, repeated 4/5 times within approximately 2 months. Water peak linewidth (LW) and area under the water peak (AP) were estimated. RESULTS: LW values [mean (standard deviation)] were 1.4 (1.0) Hz and 0.8 (0.3) Hz for 3 T and 1.5 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficient of variation of LW and AP for different spatial positions of acquisition voxel were 43% (20%) and 11% (11%), respectively. The mean (standard deviation) phantom T2values were 1145 (50) ms and 1010 (95) ms for 1.5 T and 3 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficients of variation for repeated measurements of LW, AP and T2 were 25% (20%), 10% (14%) and 5% (2%), respectively. CONCLUSIONS: We proposed a straightforward multiparametric and not time consuming quality control protocol for MRS, which can be included in routine and periodic quality assurance procedures. The protocol has been validated and proven to be feasible in a multicentre comparison study of a fairly large number of clinical 1.5 T and 3 T scanner systems.


Assuntos
Espectroscopia de Prótons por Ressonância Magnética/normas , Imagens de Fantasmas , Controle de Qualidade
3.
Phys Med ; 55: 135-141, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30342982

RESUMO

PURPOSE: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0-1000 s/mm2), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. RESULTS: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13% of centres. CONCLUSION: ADC accuracy and spatial uniformity can vary appreciably depending on MR scanner model, sequence implementation (i.e. gradient diffusion direction) and hardware characteristics. The DWI quality assurance protocol proposed in this study can be employed in order to assess the accuracy and spatial uniformity of estimated ADC values, in single- as well as multi-centre studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Difusão , Imagens de Fantasmas , Controle de Qualidade
4.
J Magn Reson Imaging ; 43(1): 213-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26013043

RESUMO

PURPOSE: To propose a magnetic resonance imaging (MRI) quality assurance procedure that can be used for multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: Twenty-six centers (35 MR scanners with field strengths: 1T, 1.5T, and 3T) were enrolled in the study. Two different DWI acquisition series (b-value ranges 0-1000 and 0-3000 s/mm(2) , respectively) were performed for each MR scanner. All DWI acquisitions were performed by using a cylindrical doped water phantom. Mean apparent diffusion coefficient (ADC) values as well as ADC values along each of the three main orthogonal directions of the diffusion gradients (x, y, and z) were calculated. Short-term repeatability of ADC measurement was evaluated for 26 MR scanners. RESULTS: A good agreement was found between the nominal and measured mean ADC over all the centers. More than 80% of mean ADC measurements were within 5% from the nominal value, and the highest deviation and overall standard deviation were 9.3% and 3.5%, respectively. Short-term repeatability of ADC measurement was found <2.5% for all MR scanners. CONCLUSION: A specific and widely accepted protocol for quality controls in DWI is still lacking. The DWI quality assurance protocol proposed in this study can be applied in order to assess the reliability of DWI-derived indices before tackling single- as well as multicenter studies.


Assuntos
Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Difusão por Ressonância Magnética/normas , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Imagem de Difusão por Ressonância Magnética/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Itália , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Radiat Oncol ; 10: 179, 2015 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-26296659

RESUMO

BACKGROUND: Whole breast irradiation after conserving surgery for breast cancer requires precise definition of the target volume. The standard approach uses computed tomography (CT) images. However, since fatty breast and non-breast tissues have similar electronic densities, difficulties in differentiating between them hamper breast volume delineation. To overcome this limitation the breast contour is defined by palpation and then radio-opaque wire is put around it before the CT scan. To optimize assessment of breast margins in the cranial, caudal, medial, lateral and posterior directions, the present study evaluated palpation and CT and determined whether ultrasound (US) provided any added value. METHODS: Twenty consecutive patients were enrolled after they had provided informed consent to participating in this prospective study which was approved by the Regional Public Health Ethics Committee. Palpation and US defined breast margins and each contour was marked and outlined with a fine plastic wire. Breasts were then contoured on axial CT images using the breast window width (WW) and window level (WL) (401 and 750 Hounsfield Units -HU- respectively), at which setting the plastic wires were invisible. Then, the lung window function (WW 1601 HU; WL -300 HU) was inserted to visualize the plastic wires which were used as guidelines to contour the palpable and US breast volumes. As each wire had a different diameter, both volumes were easily defined on CT slices. Results were analyzed using descriptive statistics, percentage overlap and reproducibility measures (agreement and reliability). RESULTS: Volumes: US gave the largest and palpation the smallest. Agreement was best between palpation and CT. Reliability was almost perfect in all correlations. Extensions: Cranial and posterior were highest with US and smallest with palpation. Agreement was best between palpation and CT in all extensions except the cranial. Since strong to almost perfect agreement emerged for all comparisons, reliability was high. CONCLUSIONS: US may be useful in defining the cranial and posterior extensions, mainly when tumours are localized there. This study demonstrates that the now standard radio-opaque wires around the palpable breast may not be needed in breast contouring.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Idoso , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia Segmentar , Pessoa de Meia-Idade , Palpação , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Ultrassonografia
6.
Neurobiol Aging ; 27(7): 926-32, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15936850

RESUMO

Mild cognitive impairment (MCI) represents a heterogeneous group of cognitive disturbances at high risk of dementia. The amnestic subtype (aMCI) might be a prodromal state of Alzheimer's disease (AD). The aim of this study is the identification, by proton magnetic resonance spectroscopy (1H MRS), of modifications in brain metabolites able to detect subjects with aMCI at risk of conversion towards AD. Twenty-five subjects with aMCI and 29 normal elderly were enrolled; they underwent a comprehensive clinical and instrumental assessment, a cerebral 1H MRS scan to measure N-acetyl aspartate (NAA), choline (Cho), myo-inositol (mI) and creatine (Cr) in the paratrigonal white matter, bilaterally. After 1 year, 5 MCI subjects became demented (progressive MCI, pMCI). Their baseline levels of metabolites were compared with those evaluated in stable MCI (sMCI) and in controls. We observed a significant difference of the NAA/Cr ratio between pMCI (1.48+/-0.08) and sMCI (1.65+/-0.12) and between pMCI and controls (1.63+/-0.16) in the left hemisphere, suggesting that this metabolic alteration can be detected before the clinical appearance of dementia.


Assuntos
Córtex Cerebral/metabolismo , Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/metabolismo , Demência/diagnóstico , Demência/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Idoso , Amnésia/diagnóstico , Amnésia/metabolismo , Amnésia/fisiopatologia , Ácido Aspártico/análogos & derivados , Ácido Aspártico/análise , Ácido Aspártico/metabolismo , Córtex Cerebral/fisiopatologia , Colina/análise , Colina/metabolismo , Transtornos Cognitivos/fisiopatologia , Creatina/metabolismo , Demência/fisiopatologia , Progressão da Doença , Feminino , Lateralidade Funcional/fisiologia , Humanos , Inositol/metabolismo , Ventrículos Laterais/patologia , Ventrículos Laterais/fisiopatologia , Masculino , Transtornos da Memória/diagnóstico , Transtornos da Memória/metabolismo , Transtornos da Memória/fisiopatologia , Fibras Nervosas Mielinizadas/metabolismo , Valor Preditivo dos Testes , Prótons
7.
Neuroimage ; 24(4): 1025-31, 2005 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-15670679

RESUMO

The present study was aimed at investigating changes in brain metabolites due to visual cortex activation in migraineurs and normal subjects by (1)H-magnetic resonance spectroscopy (MRS). Twenty-two migraine patients with aura, 22 migraine patients without aura, and 10 control subjects were assessed. The volume of interest (about 8 cm(3)) was placed on the visual cortex area and the visual stimulus was applied using MR-compatible goggles with a flashing red light at a frequency of 8 Hz and an intensity of 14 lx. Data were acquired over 36'40". The experimental time course was: baseline phase, from 0 to 3'40" (1 spectrum); on phase (flashing light condition), from 3'40" to 29'20" (1540") (7 spectra), and off phase, from 29'20" to the end of the experiment at 36'40" (2 spectra). The main result of photic stimulation in patients with migraine with aura is the more consistent decrease (-14.61%) of the N-acetylaspartate (NAA) signal, which is significantly greater than that found in migraine patients without aura and control subjects. A parallel slight increase in the lactate peak was also detected. The above findings support little differences in brain metabolites between the two patient groups assessed in interictal periods, which suggests a less efficient mitochondrial functioning in migraine with aura patients.


Assuntos
Ácido Aspártico/análogos & derivados , Química Encefálica/fisiologia , Espectroscopia de Ressonância Magnética , Enxaqueca com Aura/metabolismo , Enxaqueca sem Aura/metabolismo , Adulto , Ácido Aspártico/metabolismo , Colina/metabolismo , Cromo/metabolismo , Creatina/metabolismo , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Enxaqueca com Aura/patologia , Enxaqueca sem Aura/patologia , Estimulação Luminosa , Córtex Visual/metabolismo , Córtex Visual/patologia
8.
Ann Neurol ; 53(2): 242-7, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12557292

RESUMO

Primary progressive aphasia (PPA) is characterized by an isolated progressive impairment of word use and comprehension reflecting the distribution of pathological processes within the left hemisphere. We used proton magnetic resonance spectroscopy (1H-MRS) to study in vivo the integrity of axonal fibers connecting perisylvian language areas in 11 patients with PPA, 11 subjects with Alzheimer's disease, and 22 controls. Brain metabolites (N-acetylaspartate, myoinositol, choline, creatine) were measured bilaterally within a volume of interest located in the central portion of the superior longitudinal fasciculus, a long associative bundle connecting Broca's area with Wernicke's area, and other language regions of the temporal lobe. In the PPA group, there was an asymmetrical N-acetylaspartate to creatine ratio reduction compared with Alzheimer's disease and controls, with greater changes on the left side. The myoinositol to creatine ratio was increased in the PPA group bilaterally compared with controls. The choline to creatine ratio did not differ among the three groups. These results indicate an asymmetrical focal axonal injury within the language network in PPA. The marked difference in the distribution of N-acetylaspartate to creatine between PPA and Alzheimer's disease suggests that proton magnetic resonance spectroscopy may help to differentiate between these two conditions.


Assuntos
Afasia Primária Progressiva/patologia , Ácido Aspártico/análogos & derivados , Axônios/patologia , Lobo Frontal/patologia , Lobo Temporal/patologia , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/metabolismo , Doença de Alzheimer/patologia , Afasia Primária Progressiva/metabolismo , Ácido Aspártico/metabolismo , Creatina/metabolismo , Diagnóstico Diferencial , Feminino , Lobo Frontal/metabolismo , Humanos , Idioma , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Prótons , Lobo Temporal/metabolismo