RESUMO
PURPOSE: Anemia has been shown to be a modifiable pre-operative, patient factor associated with outcome following arthroplasty. The aims of this retrospective study were to (1) ascertain the prevalence of preoperative anemia in patients undergoing primary and revision hip and knee arthroplasty at a tertiary referral center and (2) to test the association with outcome and whether it differs between primary and revision cases. METHODS: All hip and knee primary and revision arthroplasties performed at a Canadian academic, tertiary-care, arthroplasty center between 2012 and 2017 were included in this study. The study group consisted of 5944 patients, of which 5251 were primary Total Hip and Knee Arthroplasties or Hip Resurfacings and 693 were revision arthroplasties (65% hip revisions/35% knee revisions). Anemia was classified as per WHO definition (hemoglobin < 130 g/L for men and < 120 g/L for women). All anemic patients were grouped into mild, moderate or severe anemia. Length-of-stay, perioperative transfusion-rate, 90-day readmission, overall complication rate and reoperation rates were recorded. The effect of preoperative anemia and the effect of severity of the anemia was evaluated through multivariable regression analysis controlling for relevant covariates. RESULTS: Preoperatively, 15% (786/5251) of the primary patients and 47% (322/693) of the revision arthroplasty patients were anemic preoperatively. Anemic revision patients were 3.1 times more likely (95% CI: 1.47-6.33) to obtain blood transfusions during the hospital stay, compared to a 4.9 times higher risk in primary patients. The odds ratio to sustain any postoperative complication if anemic was 1.5 times higher (95% CI: 0.73-3.16) in revision patients and 1.7 in primary cases. In addition, the 90-day readmission rate among both groups was 1.6 times higher in anemic patients. Furthermore, anemic revision patients had a 5.3 days longer length of stay (95% CI: 2.63-7.91), compared to only 1 additional day in anemic primary patients (95% CI: 0.69-1.34). CONCLUSION: In this study cohort, the prevalence of anemia in patients awaiting revision arthroplasty was 3 times higher (46.6%) than in primary arthroplasty patients (18.7%). Preoperative anemia was associated with similarly, inferior outcomes in both groups. To reduce postoperative complications and the "burden" associated with anemia, these findings strongly recommend optimizing the preoperative hemoglobin in all arthroplasty patients. However, revision patients are affected more frequently, and particular attention must therefore be taken to this growing group in the future. LEVEL OF EVIDENCE: Level III.
Assuntos
Anemia , Artroplastia de Quadril , Artroplastia do Joelho , Complicações Pós-Operatórias , Reoperação , Humanos , Masculino , Anemia/epidemiologia , Feminino , Artroplastia do Joelho/estatística & dados numéricos , Artroplastia de Quadril/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Idoso , Prevalência , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Tempo de Internação/estatística & dados numéricos , Readmissão do Paciente/estatística & dados numéricos , Transfusão de Sangue/estatística & dados numéricos , Resultado do TratamentoRESUMO
BACKGROUND: During primary total hip arthroplasty, intra-operative calcar fractures have been historically treated with cerclage wires. However, interfragmentary screw fixation technique can possibly achieve the same results with technical advantages. The aim of this biomechanical study was to assess stability of calcar fractures fixed using interfragmentary screw technique compared to a traditional cerclage system specifically in context of total hip arthroplasty. METHODS: Thirty-two periprosthetic fractures were reduced using either a single cerclage cable or an intracortical positional screw perpendicular to the fracture line. Axial and torsional load testing was terminated after experimental model failure. FINDINGS: No significant difference was obtained for all output parameters when comparing cerclage wires versus interfragmentary screw fixation respectively. Load at failure: 8043 ± 712 N vs 7425 ± 854 N (p = 0.115). Load at calcar fracture propagation: 6240 ± 2207 N versus 6220 ± 966 N (p = 0.668). Maximum stiffness before failure: 617 ± 115 N/mm vs 839 ± 175 N/mm (p = 0.100) and stiffness at calcar fracture propagation reached 771 ± 153 Nmm vs 886 ± 129 N/mm (p = 0.197). Torque to failure levels obtained were 59.4 ± 7.1 N*m vs 60.9 ± 12.0 N*m (p = 0.908). Torque to calcar fracture propagation, 51.6 ± 6.1 N*m vs 48.5 ± 9.8 N*m (p = 0.298). Torsional stiffness at failure, 0.38 ± 0.03 N*m\deg. vs 0.43 ± 0.13 N*m\deg. (p = 0.465). Torsional stiffness at calcar fracture propagation were 0.37 ± 0.03 N*m\deg. vs 0.45 ± 0.17 N*m\deg. (p = 0.462). INTERPRETATION: The strength of fixation and stability of the implant were similar for both techniques. In the synthetic bone model tested, using an interfragmentary screw conveyed similar stability to the constructs in the management of an intra-operative medial calcar fractures. Thus, potentially giving surgeons an alternative option for intraoperative fracture fixation during primary total hip arthroplasty.
Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Humanos , Artroplastia de Quadril/métodos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Fios Ortopédicos , Parafusos Ósseos , Fenômenos Biomecânicos , Placas ÓsseasRESUMO
BACKGROUND: Preoperative planning is a fundamental step for successful total hip arthroplasty (THA). Studies have highlighted the accuracy of preoperative digital templating for estimating acetabular cup and stem size. Stem design such as single-wedge metadiaphyseal (Type 1 stem) versus mid-short stem (microplasty) and surgical approach (anterior, direct lateral or posterior) have not been well investigated as predictors of THA templating accuracy. METHODS: 204 patients (220 hips) who had undergone elective THA between November 2016 and December 2019 and presented a saved preoperative template were retrospectively reviewed. Templates from 5 different surgeons were involved in the analysis. 3 different approaches were used: direct lateral (DL), posterior (PA), direct anterior (DAA). 2 different stem designs were used: single-wedge metadiaphyseal and single-wedge mid-short (Biomet Taperloc Microplasty), while the acetabular component remained the same. Bivariate and multivariate regression analyses were performed to determine predictors of accuracy. RESULTS: Femoral component size templating accuracy was significantly improved when using the single-wedge mid-short stem (Taperloc Microplasty) design when performing bivariate analysis. Although accuracy of cup sizing was not affected by approach, precision was significantly better in the PA group (p < 0.05). Accuracy of templating was found to be independent of BMI and gender but dependent on presence of calibration marker and stem design (p < 0.05). CONCLUSIONS: When striving for improved templating accuracy, acetabular and femoral component accuracy were best achieved using a calibration marker and a metaphyseal short femoral stem design.
Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Cuidados Pré-Operatórios , Articulação do Quadril/cirurgiaRESUMO
BACKGROUND: Short cementless femoral stems may allow for easier insertion with less dissection. The use of short stems with the anterior approach (AA) may be associated with a considerable perioperative fracture risk. Our aim was to evaluate whether patient-specific femoral and pelvic morphology and surgical technique, influence the perioperative fracture risk. Furthermore, we sought to describe important anatomical thresholds alerting surgeons. METHODS: A single-center, multi-surgeon retrospective, case-control matched study was performed. Thirty nine periprosthetic fractures (3.4%) in 1,145 primary AA THAs using short cementless stems were identified. These were matched with 78 THA nonfracture controls for factors known to increase the fracture risk. A radiographic analysis using validated software measured femoral (canal flare index [CFI], morphological cortical index [MCI], and calcar-calcar ratio [CCR]) and pelvic (Ilium-ischial ratio [IIR], ilium overhang, and anterior superior iliac spine [ASIS] to greater trochanter distance) morphologies and surgical techniques (% canal fill). A multivariate and Receiver-Operator Curve (ROC) analysis was used to identify fracture predictors. RESULTS: CFI (3.7 ± 0.6 vs 2.9 ± 0.4, P < .001) and CCR (0.5 ± 0.1 vs 0.4 ± 0.1, P = .006) differed. The mean IIR was higher in fracture cases (3.3 ± 0.6 vs 3.0 ± 0.5, P < .001). Percent canal fill was reduced in fracture cases (82.8 ± 7.6 vs 86.7 ± 6.8, P = .007). Multivariate and ROC analyses revealed a threshold CFI of 3.17 which was predictive of fracture (sensitivity: 84.6%/specificity: 75.6%). The fracture risk was 29 times higher when patients had CFI >3.17 and II ratio >3 (OR: 29.2 95% CI: 9.5-89.9, P < .001). CONCLUSION: Patient-specific anatomical parameters are important predictors of a fracture-risk. A careful radiographic analysis would help identify those at a risk of early fracture using short stems, and alternative stem options should be considered.
Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Fatores de RiscoRESUMO
OBJECTIVES: (1) Assess outcomes of acetabular open reduction and internal fixation (ORIF) in the elderly, (2) investigate factors influencing outcome, and (3) compare outcomes after low-energy and high-energy mechanisms of injury. DESIGN: Retrospective case series. SETTING: Level 1 trauma center. PATIENTS: Seventy-eight patients older than 60 years (age: 70.1 ± 7.4; 73.1% males). INTERVENTION: ORIF for acetabular fractures. MAIN OUTCOME MEASUREMENTS: Complications, reoperation rates, Oxford Hip Score (OHS), and joint preservation and development of symptomatic osteoarthritis. Cases with osteoarthritis, OHS < 34, and those who required subsequent total hip arthroplasty were considered as poor outcome. RESULTS: At a mean follow-up of 4.3 ± 3.7 years, 11 cases post-ORIF required a total hip arthroplasty. The 7-year joint survival post-ORIF was 80.7 ± 5.7%. Considering poor outcome as failure, the 7-year joint survival was 67.0 ± 8.9%. The grade of reduction was the most significant factor associated with outcome post-ORIF. Female sex (P = 0.03), pre-existing osteoporosis (P = 0.03), low-energy trauma (P = 0.04), and Matta grade (P = 0.002) were associated with poor outcome. Patients with associated both-column fractures were more likely to have nonanatomic reduction (P = 0.008). After low-energy trauma, joint survivorship was 36.6 ± 13.5% at 7 years compared with 75.4 ± 7.4% in the high-energy group when considering poor outcome as an end point (log rank P = 0.006). The cohort's mean OHS was 37.9 ± 9.3 (17-48). CONCLUSIONS: We recommend ORIF whenever an anatomic reduction is feasible. However, achievement and maintenance of anatomic reduction are a challenge in the elderly, specifically in those with low-energy fractures involving both columns, prompting consideration for alternative management strategies. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Fraturas do Quadril , Acetábulo/lesões , Acetábulo/cirurgia , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/etiologia , Fraturas Ósseas/cirurgia , Fraturas do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta/efeitos adversos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Optimum management for the elderly acetabular fracture remains undefined. Open reduction and internal fixation (ORIF) in this population does not allow early weight-bearing and has an increased risk of failure. This study aimed to define outcomes of total hip arthroplasty (THA) in the setting of an acetabular fracture and compared delayed THA after acetabular ORIF (ORIF delayed THA) and acute fixation and THA (ORIF acute THA). METHODS: All acetabular fractures in patients older than 60 years who underwent ORIF between 2007 and 2018 were reviewed (n = 85). Of those, 14 underwent ORIF only initially and required subsequent THA (ORIF delayed THA). Twelve underwent an acute THA at the time of the ORIF (ORIF acute THA). The ORIF acute THA group was older (81 ± 7 vs 76 ± 8; P < .01) but had no other demographic- or injury-related differences compared with the ORIF delayed THA group. Outcome measures included operative time, length of stay, complications, radiographic assessments (component orientation, leg-length discrepancy, heterotopic ossification), and functional outcomes using the Oxford Hip Score (OHS). RESULTS: Operative time (P = .1) and length of stay (P = .5) for the initial surgical procedure (ORIF only or ORIF THA) were not different between groups. Four patients had a complication and required further surgeries; no difference was seen between groups. Radiographic assessments were similar between groups. The ORIF acute THA group had a significantly better OHS (40.1 ± 3.9) than the ORIF delayed THA group (33.6 ± 8.5) (P = .03). CONCLUSION: In elderly acetabulum fractures, ORIF acute THA compared favorably (a better OHS, single operation/hospital visit, equivalent complications) with ORIF delayed THA. We would thus recommend that in patients with risk factors for failure requiring delayed THA (eg, dome or roof impaction) that ORIF acute THA be strongly considered.
Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Fraturas do Quadril , Acetábulo/cirurgia , Idoso , Artroplastia de Quadril/efeitos adversos , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/cirurgia , Fraturas do Quadril/cirurgia , Humanos , Redução Aberta/efeitos adversos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Acetabular fractures in the elderly frequently involve segmental quadrilateral plate injury, yet no consensus exists on how to best control the femoral head medial displacement. Quadrilateral surface plates (QSP) were developed to help buttress these challenging fractures. The study aims to 1) Determine the prevalence of segmental quadrilateral plate fractures (SQPF) in elderly patients; and 2) Assess if utilization of a QSP is associated with improved acetabulum fracture reduction and outcome. METHODS: This was a retrospective study conducted at a level-1 trauma centre. . All patients over 60-years that sustained an acetabular fracture between 2007 and 2019 were reviewed. Pre-operative pelvic radiographs and CT imaging were reviewed for 96 patients, to assess for SQPF. From the 96 patients reviewed, over one third of patients (n = 40, 41.6%) sustained a SQPF. Patients that had an acute-THA (n = 7) were excluded as were patients that underwent an ORIF but did not have a QSP or an anterior column buttress plate (n = 3). The remaining 30 formed the study's cohort. We assessed the ability to achieve and maintain reduction in this elderly population, and compared outcomes using traditional anterior column buttress plates (ilioingual or intra-pelvic approach) versus an intra-pelvic pre-contoured buttress suprapectineal plate (QSP). Outcome measures included: fracture reduction using the Matta classification (desirable: anatomical/imperfect and poor), re-operations, conversion to THA and Oxford Hip Score (OHS) (for the preserved hips). RESULTS: Ten patients had an ORIF with utilization of a QSP (QSP-group), and 20 had an ORIF but did not have the QSP (non-QSP-group). There was no difference in patient demographics between groups. Fracture patterns were also similar (p = 0.6). Postoperative fracture reduction was desirable (anatomical/imperfect) in 17 patients and poor in 13. Improved ability to achieve a desirable reduction was seen in the QSP-group (p = 0.02). Conversion to THA was significantly lower in patients that had a desirable fracture reduction (appropriate: 3/17; poor: 7/13). No patients in the QSP-group have required a THA to-date, compared to 10/20 patients in the non-QSP-group (p = 0.01). The mean time to THA was 1.6 ± 2.1 year. There was no difference in OHS between the two groups (34.4 ± 10.3). CONCLUSION: Elderly acetabulum fractures have a high incidence (approaching 40%) of segmental QPF. Desirable (anatomical/imperfect) fracture reduction was associated with improved outcome. The use of a QSP was associated with improved ability to achieve an appropriate reduction. A QSP should be considered as they are both reliable and reproducible with a significantly improved fracture reduction and lower conversion to THA.
RESUMO
BACKGROUND: The anterior approach (AA) to total hip arthroplasty (THA) has advantages for patients and healthcare providers. However, some studies have reported high rates of adverse events when introducing AA-THA. This was not consistent with our center's experience, where 4 senior surgeons safely introduced AA-THA into practice. The purpose of this study is to define the adverse event rates associated with the introduction of AA-THA by a group of experienced surgeons at a single tertiary care center and define experiential factors that may modify adverse event rates. METHODS: Retrospective review of prospectively collected data for an observational cohort of all patients undergoing a THA between 2006 and 2017 was conducted. Four senior surgeons at a single institution operated on 1087 primary elective hips using AA-THA. RESULTS: Between 2006 and 2016, AA-THA rose from 1.5% to 53.2% of annual THA. Adverse events included intraoperative events, early postoperative periprosthetic fractures, dislocation, implant failure, early infection, and wound complications. We observed an overall 90-day adverse event rate of 6.4% (of 1087 hips). The adverse event rate was 41.6% (of 12 hips) in the first 12 months of the study period and 3.6% (of 166 hips) in the final 12 months of the study period reviewed. Sixty hips (5.5%) required a reoperation with or without revision of components, 1 (8.3%) in the first 12 months of the study period and 1 (0.6%) in the final 12 months of the study period. Infection and wound complications were the most common causes of reoperation at 1.8% for all cases (20 hips). Higher rates of adverse events are associated with early procedures (n ≤ 15) for all surgeons but showed no statistically significant impact on 5-year survival rate. CONCLUSION: Our experience demonstrates that AA-THA can be introduced into practice with an acceptable adverse event rate when compared with other approaches to THA. As expected the incidence of adverse events is higher in the early part of the learning curve. Surgeon mentoring in the first 20 cases should be considered to minimize risk of adverse events. LEVEL OF EVIDENCE: Therapeutic Level III.
Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Artroplastia de Quadril/efeitos adversos , Humanos , Fraturas Periprotéticas/cirurgia , Complicações Pós-Operatórias/epidemiologia , Reoperação , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Resultado do TratamentoRESUMO
BACKGROUND: Fully immersive virtual reality (VR) uses headsets to situate a surgeon in a virtual operating room to perform open surgical procedures. The aims of this study were to determine (1) if a VR curriculum for training residents to perform anterior approach total hip replacement (AA-THR) was feasible, (2) if VR enabled residents' performance to be measured objectively, and (3) if cognitive and motor skills that were learned with use of VR were transferred to the physical world. METHODS: The performance of 32 orthopaedic residents (surgical postgraduate years [PGY]-1 through 4) with no prior experience with AA-THR was measured during 5 consecutive VR training and assessment sessions. Outcome measures were related to procedural sequence, efficiency of movement, duration of surgery, and visuospatial precision in acetabular component positioning and femoral neck osteotomy, and were compared with the performance of 4 expert hip surgeons to establish competency-based criteria. Pretraining and post-training assessments on dry bone models were used to assess the transfer of visuospatial skills from VR to the physical world. RESULTS: Residents progressively developed surgical skills in VR on a learning curve through repeated practice, plateauing, on average, after 4 sessions (4.1 ± 0.6 hours); they reached expert VR levels for 9 of 10 metrics (except femoral osteotomy angle). Procedural errors were reduced by 79%, assistive prompts were reduced by 70%, and procedural duration was reduced by 28%. Dominant and nondominant hand movements were reduced by 35% and 36%, respectively, and head movement was reduced by 44%. Femoral osteotomy was performed more accurately, and acetabular implant orientation improved in VR assessments. In the physical world assessments, experts were more accurate than residents prior to simulation, but were matched by residents after simulation for all of the metrics except femoral osteotomy angle. The residents who performed best in VR were the most accurate in the physical world, while 2 residents were unable to achieve competence despite sustained practice. CONCLUSIONS: For novice surgeons learning AA-THR skills, fully immersive VR technology can objectively measure progress in the acquisition of surgical skills as measured by procedural sequence, efficiency of movement, and visuospatial accuracy. Skills learned in this environment are transferred to the physical environment.
Assuntos
Artroplastia de Quadril/educação , Competência Clínica/estatística & dados numéricos , Educação Baseada em Competências/métodos , Internato e Residência/métodos , Ortopedia/economia , Treinamento por Simulação/métodos , Realidade Virtual , Adulto , Canadá , Feminino , Humanos , Curva de Aprendizado , Masculino , Modelos Anatômicos , Desempenho Psicomotor , Método Simples-CegoRESUMO
BACKGROUND: For total hip arthroplasty (THA), cognitive training prior to performing real surgery may be an effective adjunct alongside simulation to shorten the learning curve. This study sought to create a cognitive training tool (CTT) to perform anterior approach (AA)-THA, which was validated by expert surgeons, and test its use as a training tool compared with conventional material. METHODS: We employed a modified Delphi method with 4 expert surgeons from 3 international centers of excellence. Surgeons were independently observed performing THA before undergoing semistructured cognitive task analysis (CTA) and before completing successive rounds of surveys until a consensus was reached. Thirty-six surgical residents (postgraduate year [PGY]-1 through PGY-4) were randomized to cognitive training or training with a standard operation manual with surgical videos before performing a simulated AA-THA. RESULTS: The consensus CTA defined THA in 11 phases, in which were embedded 46 basic steps, 36 decision points, and 42 critical errors and linked strategies. This CTA was mapped onto an open-access web-based CTT. Surgeons who prepared with the CTT performed a simulated THA 35% more quickly (time, mean 28 versus 38 minutes) with 69% fewer errors in instrument selection (mean 29 versus 49 instances), and required 92% fewer prompts (mean 13 versus 25 instances). They were more accurate in acetabular cup orientation (inclination error, mean 8° versus 10°; anteversion error, mean 14° versus 22°). CONCLUSIONS: This validated CTT for arthroplasty provides structure for competency-based learning. It is more effective at preparing orthopaedic trainees for a complex procedure than conventional materials, as well as for learning sequence, instrumentation utilization, and motor skills. CLINICAL RELEVANCE: Cognitive training combines education on decision-making, knowledge, and technical skill. It is an inexpensive technique to teach surgeons to perform hip arthroplasty and is more effective than current preparation methods.
Assuntos
Artroplastia de Quadril/educação , Competência Clínica/normas , Cognição , Internato e Residência/normas , Treinamento por Simulação/métodos , Adulto , Artroplastia de Quadril/métodos , Artroplastia de Quadril/normas , Canadá , Feminino , Humanos , Internato e Residência/métodos , Curva de Aprendizado , Masculino , Centros Cirúrgicos , Ensino , Reino Unido , Realidade VirtualRESUMO
Construct: We compared a single-item performance score with the Ottawa Surgical Competency Operating Room Evaluation (O-SCORE) for their ability in assessing surgical competency. BACKGROUND: Surgical programs are adopting competency-based frameworks. The adoption of these frameworks for assessment requires tools that produce accurate and valid assessments of knowledge and technical performance. An assessment tool that is quick to complete could improve feasibility, reduce delays, and result in a higher volume of assessments of learners. Previous work demonstrated that the 9-item O-SCORE can produce valid results; the goal of this study was to determine if a single-item performance rating (Is candidate competent to independently complete procedure: yes or no) completed at a separate viewing would correlate to the O-SCORE, thus increasing feasibility of procedural competence assessment. APPROACH: Nineteen residents and 2 staff orthopedic surgeons from the University of Ottawa volunteered for a 2-part OSCE-style station including a written questionnaire and videotaped simulated open reduction and internal fixation midshaft radius fracture. Each performance was rated independently by 3 orthopedic surgeons using a single-item performance score (Time 1). The performances were assessed again 6 weeks later by the 3 raters using the O-SCORE (Time 2). Correlation between the single-item performance score and the O-SCORE were evaluated. RESULTS: Three orthopedic surgeons completed 21 ratings each resulting in 63 orthopedic ratings. There was a high level of correlation and agreement between the single-item performance score at Time 1 and Time 2 (κ correlation =0.72-1.00; p < .001; percentage agreement =90%-100%). The reliability of the O-SCORE at Time 2 with three raters was 0.83 and the internal consistency was 0.89. There was a tendency for each rater to assign more yes responses to the more senior trainees. CONCLUSIONS: A single-item performance score correlated highly with the O-SCORE in an orthopedic setting. A single-item score could be used to supplement a multi-item score with similar results in orthopedics. There is still benefit in completing multi-item scores such as the O-SCORE evaluations to guide specific areas of improvement and direct feedback.
Assuntos
Lista de Checagem , Competência Clínica/normas , Avaliação Educacional/métodos , Cirurgia Geral/educação , Canadá , HumanosRESUMO
BACKGROUND: Added modular junction has been associated with implant-related failures. We report our experience with a titanium-titanium modular neck-stem interface to assess complications, possible clinical factors influencing use of neck modularity, and whether modularity reduced the incidence of dislocation. METHODS: A total of 809 total hip arthroplasties completed between 2005 and 2012 from a prospectively collected database were reviewed. The mean follow-up interval was 5.7 years (3.3-10.3 years). Forty-five percent were male (360 of 809), and 55% were female (449 of 809). All stems were uncemented PROFEMUR TL (titanium, flat-tapered, wedge) or PROFEMUR Z (titanium, rectangular, dual-tapered) with a titanium neck. RESULTS: Increased modularity (anteverted/retroverted and anteverted/retroverted varus/valgus (anteverted/retroverted + anteverted/retroverted varus/valgus) was used in 39.4% (135 of 343) of cases using the posterior approach compared with 6.8% (20 of 293) of anterior and 23.7% (41 of 173) of lateral approaches. Four males sustained neck fractures at a mean of 95.5 months (69.3-115.6 months) after primary surgery. Overall dislocation rate was 1.1% (9 of 809). The posterior approach had both the highest utilization of increased modularity and the highest dislocation rate (2.3%), of which the most were recurrent. The anterior (0.3%) and lateral (0%) approaches had lower dislocation rates with no recurrences. CONCLUSION: At a mean 5.7 years, our experience demonstrates a low neck fracture (0.5%) and a low dislocation rate (1.1%). Use of increased modularity may not improve dislocation risk for the posterior approach. Continued surveillance of this group will be necessary to determine long term survivorship of this modular titanium implant.
Assuntos
Artroplastia de Quadril/instrumentação , Luxação do Quadril/epidemiologia , Prótese de Quadril/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Falha de Equipamento , Feminino , Luxação do Quadril/etiologia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Osteoartrite do Quadril/cirurgia , Complicações Pós-Operatórias/etiologia , Falha de Prótese/etiologia , Estudos Retrospectivos , Fatores de Risco , Titânio , Adulto JovemRESUMO
As surgical techniques continue to evolve, surgeons will have to integrate new skills into their practice. A learning curve is associated with the integration of any new procedure; therefore, it is important for surgeons who are incorporating a new technique into their practice to understand what the reported learning curve might mean for them and their patients. A learning curve should not be perceived as negative because it can indicate progress; however, surgeons need to understand how to optimize the learning curve to ensure progress with minimal patient risk. It is essential for surgeons who are implementing new procedures or skills to define potential learning curves, examine how a reported learning curve may relate to an individual surgeon's in-practice learning and performance, and suggest methods in which an individual surgeon can modify his or her specific learning curve in order to optimize surgical outcomes and patient safety. A defined personal learning contract may be a practical method for surgeons to proactively manage their individual learning curve and provide evidence of their efforts to safely improve surgical practice.
Assuntos
Educação Médica Continuada/métodos , Invenções , Curva de Aprendizado , Ortopedia , Competência Clínica , Humanos , Ortopedia/educação , Ortopedia/métodos , Ortopedia/normas , Melhoria de QualidadeRESUMO
Practicing orthopaedic surgeons must assess the effects of the learning curve on patient safety and surgical outcomes if a new implant, technique, or approach is being considered; however, it remains unclear how learning curves reported in the literature should be interpreted and to what extent their results can be generalized. Learning curve reports from other surgical specialties and from orthopaedic surgery can be analyzed to identify the strengths and weaknesses of learning curve reporting. Single-surgeon series and registry data can be analyzed to understand learning challenges and to develop a personalized learning plan. Learning curve reports from single-surgeon series have several limitations that result from the limited dataset reported and inconsistencies in the way data are reported. Conversely, learning curve reports from registry data are likely to have greater generalizability, but are largely beneficial retrospectively, after data from a sufficient number of surgeons are assessed. There is a pressing need for surgeons to develop improved and consistent standards for learning curve reporting. Although registry data may provide better prospective measures in the future, the implementation of such registries faces several challenges. Despite substantial limitations, single-surgeon series remain the most effective way for practicing surgeons to assess their learning challenge and develop an appropriate learning plan.
Assuntos
Invenções , Curva de Aprendizado , Ortopedia , Sistema de Registros/normas , Projetos de Pesquisa/normas , Escolaridade , Humanos , Ortopedia/educação , Ortopedia/métodos , Ortopedia/normas , Avaliação de Processos e Resultados em Cuidados de Saúde , Gestão da Segurança/métodos , Gestão da Segurança/organização & administraçãoRESUMO
UNLABELLED: CONSTRUCT: The Ottawa Surgical Competency Operating Room Evaluation (O-SCORE) is a 9-item surgical evaluation tool designed to assess technical competence in surgical trainees using behavioral anchors. BACKGROUND: The initial development of the O-SCORE produced evidence for valid results. Further work is required to determine if the use of a single surgeon or an unblinded rater introduces bias. In addition, the relationship of the O-SCORE to other currently used technical assessment tools should be explored to provide validity evidence related to the relationship to other measures. We have designed this project to provide continued validity evidence for the O-SCORE related to these two issues. APPROACH: Nineteen residents and 2 staff Orthopedic Surgeons from the University of Ottawa volunteered to participate in a 2-part OSCE style station. Participants completed a written questionnaire followed by a videotaped 10-minute simulated open reduction and internal fixation of a midshaft radius fracture. Videos were rated individually by 2 blinded staff orthopedic surgeons using an Objective Structured Assessment of Technical Skills (OSATS) global rating scale, an OSATS checklist, and the O-SCORE in random order. RESULTS: O-SCORE results appeared sensitive to surgical training level even when raters were blinded. In addition, strong agreement between two independent observers using the O-SCORE suggests that the measure captures a performance easily recognized by surgical observers. Ratings on the O-SCORE also were strongly associated with global ratings on the currently most validated technical evaluation tool (OSATS). Collectively, these results suggest that the O-SCORE generates accurate, reproducible, and meaningful results when used in a randomized and blinded fashion, providing continued validity evidence for using this tool to evaluate surgical trainee competence. CONCLUSIONS: The O-SCORE was able to differentiate surgical trainee level using blinded raters providing further evidence of validity for the O-SCORE. There was strong agreement between two independent observers using the O-SCORE. Ratings on the O-SCORE also demonstrated equivalence to scores on the most validated technical evaluation tool (OSATS). These results suggest that the O-SCORE demonstrates accurate and reproducible results when used in a randomized and blinded fashion providing continued validity evidence for this tool in the evaluation of surgical competence in the trainees.
Assuntos
Lista de Checagem/normas , Competência Clínica/normas , Salas Cirúrgicas , Treinamento por Simulação , Feminino , Humanos , Internato e Residência , Masculino , Ortopedia , Cirurgiões , Inquéritos e QuestionáriosRESUMO
UNLABELLED: CONSTRUCT: The competence of a trainee to perform a surgical procedure was assessed using an electronic tool. BACKGROUND: "Going paperless" in healthcare has received significant attention over the past decades given the numerous potential benefits of converting to electronic health records. Not surprisingly, medical educators have also considered the potential benefits of electronic assessments for their trainees. What literature exists on the transition from paper-based to electronic-based assessments suggests a positive outcome. In contrast, work done examining the transition to and implementation of electronic health records has noted that hospitals who have implemented these systems have not gone paperless despite the benefits of doing so. APPROACH: This study sought to transition a paper-based assessment tool, the Ottawa Surgical Competency Operating Room Evaluation (which has strong evidence for validity) to an electronic version, in three surgical specialties (Orthopedic Surgery, Urology, General Surgery). However, as the project progressed, it became necessary to change the focus of the study to explore the issues of transitioning to a paperless assessment tool as we identified an extremely low participation rate. RESULTS: Over the first 3 months 440 assessment cases were logged. However, only a small portion of these cases were assessed using the electronic tool (Orthopedic Surgery = 16%, Urology = 5%, General Surgery = 0%). Participants identified several barriers in using the electronic assessment tool such as increased time compared to the paper version and technological issues related to the log-in procedure. CONCLUSIONS: Essentially, users want the tool to be as convenient as paper. This is consistent with research on electronic health records implementation but different from previous work in medical education. Thus, we believe our study highlights an important finding. Transitioning from a paper-based assessment tool to an electronic one is not necessarily a neutral process. Consideration of potential barriers and finding solutions to these barriers will be necessary in order to realize the many benefits of electronic assessments.
Assuntos
Automação , Competência Clínica/normas , Avaliação Educacional/métodos , Especialidades Cirúrgicas/educação , Estudantes de Medicina , HumanosRESUMO
PURPOSE: Most assessment of surgical trainees is based on measures of knowledge, with limited evaluation of their competence to actually perform various surgical procedures. In this study, the authors evaluated a tool they designed to assess a trainee's competence to perform an entire surgical procedure independently, regardless of procedure type or postgraduate year (PGY). METHOD: In phase 1, the Ottawa Surgical Competency Operating Room Evaluation (O-SCORE) was piloted in the University of Ottawa's Division of Orthopaedic Surgery. In phase 2, the refined 11-item tool (8 items rated on a 5-point competency scale, 1 item assessing procedural competence, 2 feedback items) was used in the Divisions of Orthopaedic Surgery and General Surgery to assess residents' performance on 11 common procedures. Quantitative and qualitative analyses were conducted. RESULTS: In phase 2, 34 orthopaedic and general surgeons assessed the performance of 37 residents in 163 procedures. ANOVA demonstrated an effect of PGY. Post hoc analysis found that total procedure scores for PGYs 1 and 2 were lower than those for PGY 3 (P<.001), and PGY 3 scores were lower than those for PGYs 4 and 5 (P<.02). Analysis of qualitative data indicated that the rating scale was practical and useful for surgeons and residents. CONCLUSIONS: This novel evaluation tool successfully discriminated between junior and senior residents and identified surgical competency across various PGY levels regardless of procedure type. Multiple sources of evidence support the O-SCORE as a valid tool for the assessment of trainee operative competency.
Assuntos
Competência Clínica/normas , Internato e Residência/normas , Procedimentos Ortopédicos/educação , Ortopedia/educação , Análise de Variância , Humanos , Variações Dependentes do Observador , Ontário , Procedimentos Ortopédicos/normas , Ortopedia/normas , Projetos Piloto , Reprodutibilidade dos TestesRESUMO
The management of intra-articular distal humeral fractures remains a difficult surgical problem. Although an olecranon osteotomy provides excellent exposure for management of these fractures, a number of complications can occur after the creation and repair of the osteotomy including nonunion, malunion, hardware failure, and pain secondary to prominent hardware. In an effort to reduce the incidence of these complications, the senior authors now use contoured 3.5 mm reconstruction plates for the fixation of their apex-distal chevron olecranon osteotomies. Two surgeons at a single institution used this technique of exposure on a series of 17 consecutive patients with intra-articular distal humerus fractures between 1996 and 1999. In this series, all osteotomies united. There was one complication related specifically to the osteotomy: one of the screws in the plate penetrated the proximal radioulnar joint, interfering with forearm rotation; a second procedure was required to shorten the screw. Only one of the 17 patients requested plate removal during the 32 month (average) follow-up period. Plate fixation of olecranon osteotomies using a 3.5 mm reconstruction plate provides a construct with predictable healing and few complications. The overall results using this technique are comparable with other reported methods in the literature.
Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Osteotomia/instrumentação , Osteotomia/métodos , Fraturas da Ulna/cirurgia , Feminino , Humanos , Fraturas do Úmero/diagnóstico por imagem , Masculino , Guias de Prática Clínica como Assunto , Padrões de Prática Médica , Radiografia , Estudos Retrospectivos , Resultado do Tratamento , Fraturas da Ulna/diagnóstico por imagemRESUMO
PURPOSE: Distal radioulnar joint (DRUJ) instability can result in pain and functional disability. Numerous DRUJ reconstructive options have been described with minimal biomechanical analysis. The purpose of this study was to evaluate the ability of 4 well-described DRUJ reconstructions to restore joint kinematics using a dynamic, motion-controlled simulator. METHODS: Eleven cadaveric upper extremities had computer-controlled simulated active forearm rotation. Joint kinematics were quantified by using an electromagnetic tracking system. We compared the passive and simulated active kinematics of the intact, unstable, and reconstructed DRUJ (capsular repair, 2 described radioulnar ligament reconstructions, and a radioulnar tethering procedure). RESULTS: All reconstructions improved significantly the kinematics of the unstable DRUJ. The capsule repair restored simulated active joint kinematics closest to the intact DRUJ. CONCLUSIONS: All 4 reconstructions improved DRUJ stability significantly. The capsule repair most closely matched intact DRUJ kinematics and the radioulnar ligament reconstructions were found to be superior to a radioulnar tethering procedure.
Assuntos
Instabilidade Articular/cirurgia , Procedimentos de Cirurgia Plástica , Rádio (Anatomia)/cirurgia , Ulna/cirurgia , Articulação do Punho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pronação/fisiologia , Rotação , Supinação/fisiologia , Articulação do Punho/fisiopatologiaRESUMO
OBJECTIVE: The objective of this study was to determine whether there is alteration in resultant joint moment of the hip extensors and adductors after hamstring anterior cruciate ligament (ACL) reconstruction. DESIGN: Cross-sectional outcome analysis. SETTING: University sport medicine center. SUBJECTS: Fifteen subjects more than 1 year after ACL reconstruction with semitendinosus and gracilis tendons were compared with 15 matched controls with no knee injury. INTERVENTIONS: Strength testing of the hip extensors and hip adductors of both limbs. MAIN OUTCOME MEASUREMENTS: Isokinetic (50 degrees /s and 150 degrees /s) hip extensor strength test and isometric (15 degrees and 30 degrees ) hip adductor strength test. RESULTS: Hip extensors increase in strength after hamstring ACL reconstruction, evening out normal side-to-side strength differences. Hip adductor strength deficits of up to 43% are demonstrated in the ACL reconstructed subjects compared with controls. CONCLUSIONS: The identification of hip adductor strength deficits after hamstring harvest for ACL reconstruction may have important implications for both graft harvest site selection as well as postoperative rehabilitation protocols. Given the known existence of knee strength deficits after ACL reconstruction, increases in isovelocity hip extensor strength may contribute to increased lower limb strength imbalances. This may have implications for the ability of the lower limb muscles to protect the ACL graft.