Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 329
Filtrar
1.
Braz Oral Res ; 38: e049, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38922209

RESUMO

The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical external hexagon (EH) and Morse Taper (MT) implants. Forty-four single implants were placed in the edentulous areas of 20 patients who met the inclusion and exclusion criteria. Immediately after implant placement (t1) and after osseointegration (four and six months for mandible and maxilla, respectively) (t2), insertion torque, resonance frequency, and peri-implant bone loss were measured using probing depths and digital periapical radiography. A significant difference was noted in the ISQ values between t1 and t2 in type III bone for EH and MT implants. No significant difference in bone loss values was observed when comparing bone types for EH or MT in all evaluated sites. Based on marginal bone loss assessed using radiography, there was no significant difference between the MT and EH groups. A positive correlation between torque and ISQ t1 value was observed for MT (correlation: 0.439; p = 0.041) and EH (correlation: 0.461; p = 0.031) implants. For EH and MT implants, the greater the insertion torque, the greater was the ISQ value (moderately positive correlation). A weak negative correlation was found between bone type and ISQ t1 for MT implants. Contrarily, no correlation was observed between bone type and ISQ t1 for EH implants. In all cases, bone loss around the implants was clinically normal.


Assuntos
Perda do Osso Alveolar , Implantação Dentária Endóssea , Osseointegração , Torque , Humanos , Masculino , Feminino , Perda do Osso Alveolar/diagnóstico por imagem , Osseointegração/fisiologia , Implantação Dentária Endóssea/métodos , Pessoa de Meia-Idade , Valores de Referência , Fatores de Tempo , Resultado do Tratamento , Estatísticas não Paramétricas , Planejamento de Prótese Dentária , Adulto , Mandíbula/cirurgia , Mandíbula/diagnóstico por imagem , Retenção em Prótese Dentária/métodos , Idoso , Análise de Frequência de Ressonância , Implantes Dentários , Maxila/cirurgia , Maxila/diagnóstico por imagem , Implantes Dentários para Um Único Dente , Reprodutibilidade dos Testes
2.
Rev. Odontol. Araçatuba (Impr.) ; 45(1): 65-68, jan.-abr. 2024. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1553267

RESUMO

A Revista Odontológica de Araçatuba é um periódico online, de acesso gratuito cujo as publicações são indexadas em importantes bases de dados, divulgando deste modo trabalhos científicos produzidos por instituições do estado de São Paulo e de outros centros de pesquisa de todo o país. O intuito deste trabalho é analisar de modo quantitativo as publicações realizadas no período de 2018 a 2023, as classificando de acordo com a sua natureza (Pesquisa cientifica, Revisão de literatura ou relato de caso) e de acordo com a sua origem (UNESP ­ FOA, misto ou outro centro de ensino) e comparar os resultados obtidos aos dados presentes nos estudos referentes ao período de 2001 a 2011 e ao estudo referente ao período de 2012 a 2017. Foi realizada uma pesquisa bibliográfica que compreendeu as publicações dos anos de 2018 a 2023, abrangendo 18 periódicos e um suplementar, totalizando 167 artigos. Neste intervalo de tempo, houve uma predominância de relatos de casos (55,08%) em comparação as revisões de literatura (22,15%) e as pesquisas cientificas (22,75%). Os artigos oriundos de outros centros de pesquisa foram a maioria (82,03%) e 8 dos artigos presentes foram em língua inglesa. Podemos concluir que a Rev. Odontol. Araçatuba se tornou um periódico de relevância nacional com predominância de compromisso clinico e que está em processo de internacionalização(AU)


The Dental Journal of Araçatuba is an online journal, with free access, whose publications are indexed in important databases, publishing scientific works produced by institutions in the state of São Paulo and other research centers across the country. The purpose of this work is to analyze, in a quantitative way, the publications carried out in the period from 2018 to 2023, classifying them according to their nature (Scientific research, Literature review or case report) and according to their origin (UNESP ­ FOA , mixed or other teaching center) and compare the results obtained with the datas presents in the studies referring to the period from 2001 to 2011 and the study referring to the period from 2012 to 2017. A bibliographical research was carried out that included publications from the years 2018 to 2023, covering 18 periodicals and one supplementary, totaling 167 articles published. In this time period, case report articles predominated (55,08%) compared to literature reviews (22.15%) and scientific research (22,75%). The majority of articles came from other research centers (82.03%) and 8 of the published articles were in English. We can conclude that Journal Dental of Araçatuba became a periodical of national relevance with a predominance of clinical commitment and which is in process of internationalization(AU)


Assuntos
Odontologia , Publicação Periódica , Comunicação e Divulgação Científica , Publicações Científicas e Técnicas
3.
Rev. Odontol. Araçatuba (Impr.) ; 45(1): 59-64, jan.-abr. 2024. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1553266

RESUMO

Introdução: O tratamento de tumores malignos ou benignos, podem resultar em procedimentos cirúrgicos, como a maxilectomia parcial ou total, gerando comunicação bucosinusal nos pacientes. Uma forma de resolver estas alterações maxilofaciais é através do tratamento reabilitador com próteses obturadoras a fim de restabelecer a função mastigatória, estética, fonética e psicológica. Objetivo: o objetivo deste trabalho foi relatar o caso clínico de um paciente oncológico que foi reabilitado com prótese obturadora devido à maxilectomia por neoplasia maligna de seio maxilar. Relato de caso: Paciente de 62 anos, sexo masculino, procurou atendimento odontológico no Centro de Oncologia Bucal da Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP) de Araçatuba ­ SP após a realização de uma maxilectomia parcial com comunicação bucosinusal e foi encaminhado para o Curso de Especialização em Prótese Dentária da Faculdade de Odontologia ­ Unesp/Araçatuba-SP para a reabilitação. Foi proposto, primeiramente a realização da prótese obturadora para fechar a comunicação bucosinusal e uma prótese total inferior para o arco antagonista e, posteriormente, a realização de uma prótese facial. Conclusão: O tratamento reabilitador com próteses obturadoras possui um bom resultado estético e funcional, favorecendo uma melhor função mastigatória e fonética, e melhorando consideravelmente a condição psicológica que é muito afetada nos pacientes submetidos a maxilectomia total ou parcial, sendo necessário uma boa interação com toda a equipe multiprofissional envolvida para que haja um melhor tratamento integrado para a reabilitação e melhora da qualidade de vida(AU)


Introduction: The treatment of malignant or benign tumors can result in surgical procedures, such as partial or total maxillectomy, generating oral communication in patients. One way to resolve these maxillofacial changes is through rehabilitative treatment with obturator prostheses in order to reestablish masticatory, aesthetic, phonetic and psychological function. Objective: the objective of this work was to report the clinical case of a cancer patient who was rehabilitated with an obturator prosthesis due to maxillectomy for malignant neoplasia of the maxillary sinus. Case report: A 62-year-old male patient sought dental care at the Oral Oncology Center of the Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP) in Araçatuba ­ SP after undergoing a partial maxillectomy with oral cavity and was referred for the Specialization Course in Dental Prosthesis at the Faculty of Dentistry ­ Unesp/Araçatuba-SP for rehabilitation. It was proposed, firstly, to create an obturator prosthesis to close the bucosinusal communication and a total lower prosthesis for the antagonistic arch and, later, to create a facial prosthesis. Conclusion: Rehabilitative treatment with obturator prostheses has a good aesthetic and functional result, favoring better chewing and phonetic function, and considerably improving the psychological condition that is greatly affected in patients undergoing total or partial maxillectomy, requiring good interaction with the entire the multidisciplinary team involved so that there is better integrated treatment for rehabilitation and improved quality of life


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Obturadores Palatinos , Neoplasias Bucais , Prótese Maxilofacial , Reabilitação Bucal , Procedimentos Cirúrgicos Bucais , Maxila/cirurgia
4.
J Clin Exp Dent ; 16(3): e367-e376, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38600931

RESUMO

Background: The aim of this systematic review is to determine the effectiveness of self-etching primers in comparison to the conventional protocol with hydrofluoric acid and silane treatment for bonding lithium disilicate ceramics. Material and Methods: The formulated PICO question for this research was: "Does self-etching silane primer surface treatment in lithium disilicate ceramics present a similar bond strength value compared to conventional hydrofluoric acid and silane treatment?". Combinations of words and appropriate truncations were adapted for each database. For the selection, duplicate articles were systematically eliminated using Mendeley software. The Cohen's Kappa statistic was then computed, RoBDEMAT questions were addressed, and the meta-analyses were conducted using RevMan 5.4, at a significance level of 5%. Results: Two independent reviewers conducted a blind and independent analysis of 190219 articles from PubMed, Scopus, Web of Science, and OpenGrey. Subsequently, they extracted data from 21 studies for the systematic review and in 16 the meta-analysis. In all in vitro studies, the most frequently cited concentration of hydrofluoric acid was 5%. In the meta-analysis, no statistical differences were observed between the two treatments concerning bond strength. Conclusions: Self-etching silane primers demonstrate promising results in lithium disilicate bonding, suggesting their potential as an alternative surface treatment to hydrofluoric acids + silane. Key words:Lithium disilicate, Hydrofluoric acid, Dental Porcelain, Ceramics, Silanes.

5.
Gerodontology ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563231

RESUMO

OBJECTIVE: To evaluate the touch perception threshold of the alveolar mucosa and quality of life of edentulous patients before (T0) and 30 days after (T1) the insertion of new complete dentures. BACKGROUND: Touch perception is important so that edentulous patients can detect the position of complete dentures in their mouth. MATERIALS AND METHODS: This study included 32 complete denture wearers with good oral and systemic health and no temporomandibular disorders for at least 5 years. At each time point (T0 and T1), two tests were performed (touch perception threshold and quality-of-life scale). The touch perception threshold (Von Frey or Semmes-Weinstein test) was assessed using nylon monofilaments on the regions of the alveolar mucosa of the maxilla and mandible. The Oral Health Impact Profile for edentulous individuals (OHIP-EDENT) was administered to evaluate oral health-related quality of life. RESULTS: In the maxilla and mandible, the touch perception thresholds for all regions of the alveolar mucosa were significantly lower at T1 than at T0. The OHIP-EDENT mean scores showed that the overall quality of life was significantly better at T1 (3.6) than at T0 (4.7), and a significant improvement in quality of life was observed in all domains of the OHIP-EDENT at T1. For touch perception threshold, effect sizes ranged from 0.4 to 0.8; and for quality of life, effect sizes ranged from 0.4 to 1.0. CONCLUSIONS: New complete dentures reduced the touch perception threshold of the alveolar mucosa of both edentulous arches and improved individuals' quality of life.

6.
Biomed Tech (Berl) ; 69(1): 1-10, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37489593

RESUMO

OBJECTIVES: To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ). CONTENT: Methods to evaluate the stability of dental implants. SUMMARY: A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined "resonance frequency analysis" and "Periotest" with "correlation" or "relationship"; and combinations of "implant stability quotient" and "Periotest" with "correlation" or "relationship." The inclusion criteria were clinical studies in English involving human subjects who received dental implants and evaluating the correlation between PTV and ISQ. A total of 46 articles were screened, of which 10 were selected for full-text analysis, and eight articles were included in this review. Based on three articles, 75 % of the results of this systematic review showed a negative correlation between PTV and ISQ, regardless of the type of stability assessed. Based on the remaining five articles, 100 % (regardless of the patient's gender) and 66.66 % of the results showed a negative correlation for primary and secondary stability, respectively. There is a negative correlation between PTV and ISQ for both primary and secondary dental implant stability. OUTLOOK: This review can serve as a reference for the development of methodologies for future clinical studies on this topic.


Assuntos
Implantes Dentários , Osseointegração , Humanos , Implantação Dentária Endóssea , Retenção em Prótese Dentária
7.
Prague Med Rep ; 124(4): 359-379, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38069643

RESUMO

During the fabrication of a complete denture, functional impression is taken. Literature studies show that polydimethylsiloxane (condensation silicone) has not been reported by United States dental schools to perform border molding. Thus, the purpose of this article is to review the functional impression technique when border molding is performed with a laboratory condensation silicone putty.


Assuntos
Prótese Total , Silicones , Humanos
8.
Prague Med Rep ; 124(4): 380-391, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38069644

RESUMO

The objective of this article is to concisely review the main clinical techniques used to make the functional impression to manufacture a removable partial denture. Through this review, the dentist can develop his clinical knowledge.


Assuntos
Prótese Parcial Removível , Humanos
9.
Braz Dent J ; 34(6): 1-9, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38133082

RESUMO

In this study, we aimed to evaluate the halitosis and pain threshold of the peri-implant soft tissues in individuals rehabilitated with implant-supported prostheses. Forty-eight subjects were divided into four groups (n = 12) according to their prosthetic rehabilitation: single-tooth fixed prosthesis, multi-tooth fixed prosthesis, overdentures, and the Brånemark protocol. Halitosis was measured using a halimeter, whereas the pain threshold was measured using Von Frey monofilaments. Measurements were taken before (t0) and 30 days after (t1) placement of healing caps, and at the time of (t2) and 30 days after (t3) prosthetic placement. Halitosis data were analyzed using the chi-square test and Bonferroni correction (p < 0.05). Two-way ANOVA and Tukey's test (p < 0.05) were used to analyze pain threshold data. We noted an association between halitosis and time for the Brånemark protocol [X2(6) = 18.471; p = 0.005] and overdenture groups [X2(6) = 17.732; p = 0.007], and between halitosis and type of prosthesis only at t0 [X2(6) = 12.894; p = 0.045]. The interaction between time and the type of prosthesis significantly interfered with the mean pain threshold values (p = 0.001). At most time points, the majority of participants in each group had clinically unacceptable halitosis. After 30 days of using the prostheses, the overdenture group had a lower pain threshold compared to the Brånemark protocol group.


Assuntos
Implantes Dentários , Halitose , Dente , Humanos , Limiar da Dor , Estudos de Coortes , Prótese Dentária Fixada por Implante
10.
Med J Armed Forces India ; 79(5): 547-550, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37719914

RESUMO

Background: Ocular prosthesis rehabilitation has an important social, psychological, esthetic, and functional role. Congenital factors, trauma, and tumors, among others, can cause anophthalmia, and it is essential to identify the etiology to guide its prevention and treatment. Methods: The aim of this study was to retrospectively investigate the records of patients treated from 2013 to 2020 by the Oral and Maxillofacial Prosthesis Group, aiming to identify the prevalence of patients with anophthalmia and the etiology of their anophthalmia. After approval by the Human Research Ethics Committee, two calibrated researchers evaluated 520 records, identifying those from patients with anophthalmia. The inclusion criteria were records with complete and legible information from patients with anophthalmia and a description of their etiology. Descriptive statistics were performed, and etiological factors were categorized into trauma, congenital cause, end-stage eye disease, and tumor. Spearman's correlation was performed to verify the relation between gender and anophthalmia etiology, with a 5% significance level. Seventy-two records were included in the study. Results: It was observed that 33.4% of patients were women and 66.6% were men. The etiologies were physical trauma (52.4%), tumor (21.8%), end-stage eye disease (16.6%), and congenital cause (9.2%), and there was no correlation between gender and these etiologies (p = .301). Conclusion: Most of the cases identified were of traumatic origin, which allows the establishment of preventive and educational measures to avoid new cases of anophthalmia.

11.
Polim Med ; 53(1): 37-46, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37260125

RESUMO

BACKGROUND: Polymethylmethacrylate (PMMA) is the most used material for the manufacturing of eye prostheses. OBJECTIVES: To investigate the cytotoxicity of different cleaning agents for ocular prostheses on human conjunctival cells. MATERIAL AND METHODS: Six groups of specimens were created (saline, soap, 4% chlorhexidine, hydrogen peroxide, 1% triclosan, and citronella oil). Three specimens were made for each disinfectant at each disinfection period (1, 7, 15, 30, 60, and 90 days), totaling 108 specimens. Thus, the specimens were disinfected, with different disinfectants, for different periods of time. After each disinfection process, the specimens were washed with sterile distilled water. A human conjunctival cell line was grown on the acrylic resin specimens and then cytotoxicity tests (MTT and Neutral Red (NR)) were performed. A negative control (untreated cell cultures) and positive control (Tween 20) were created. Two-way analysis of variance (ANOVA) and Bonferroni test were performed (p < 0.05). RESULTS: For the MTT and NR tests, when there was a significant difference between the disinfectant and negative control, the disinfectant generated a significant reduction in cell proliferation most of the time. CONCLUSIONS: All reductions in cell proliferation caused by the disinfectants were clinically acceptable. All disinfectants tested in this study were found to be non-cytotoxic to human conjunctival cells.


Assuntos
Desinfetantes , Olho Artificial , Humanos , Teste de Materiais , Desinfetantes/toxicidade , Clorexidina , Desinfecção
12.
Polim Med ; 53(1): 19-24, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36929643

RESUMO

BACKGROUND: Occlusal splints can protect teeth during bruxism, preventing tooth wear, as well as during sports activities, shielding them from impacts. OBJECTIVES: To verify the influence of thermal cycles and disinfection on the roughness, microhardness and color of polyethylene terephthalate glycol/thermoplastic polyurethane (PETG/TPU) and poly(methyl methacrylate) (PMMA). MATERIAL AND METHODS: Thirty-six PETG/TPU samples and 36 PMMA samples were prepared (ø10 mm × 3 mm). Six groups were created according to the material and the disinfection method used (n = 12 each): PETG/TPU (glister), PETG/TPU (hypochlorite), PETG/TPU (soap), PMMA (glister), PMMA (hypochlorite), and PMMA (soap). Roughness, Knoop microhardness and color evaluations were performed before the experiments (T1), after thermocycling (T2) and after disinfection (T3). Three-way repeated measures analysis of variance (ANOVA) and Tukey's test were used for statistical evaluations. RESULTS: For roughness and color, ANOVA showed statistical significance based on the interaction between thermal cycling, material and disinfectant factors. In terms of Knoop microhardness, ANOVA showed statistical significance based on the interaction between thermal cycling and material factors. CONCLUSIONS: Roughness results were clinically acceptable in all groups at all time points, except the PETG/TPU and PMMA groups disinfected with hypochlorite. Microhardness significantly increased for both materials after thermal cycling, and at all time points, the microhardness of PMMA was significantly higher than that of PETG/TPU. After thermal cycling, the color changes were clinically unacceptable in all groups.


Assuntos
Desinfecção , Polimetil Metacrilato , Desinfecção/métodos , Ácido Hipocloroso , Teste de Materiais , Sabões , Propriedades de Superfície
13.
Eur J Dent ; 17(1): 1-6, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35728615

RESUMO

The selection of material used on the occlusal surface of implant-supported prostheses is important, as these materials can transmit destructive forces to the interface between the alveolar bone and the implant. Different prosthetic materials are suggested for implant-supported prostheses. The choice of prosthetic material is a controversial issue, and there is a consensus that implant survival is not affected by the prosthetic material. Three-dimensional finite element studies are often used in dentistry to estimate the stress distribution that occurs in the implant system, peri-implant bone, and prosthetic components. To analyze the influence of the prosthetic restorative material on the stresses in bone tissue and peri-implant through a literature review of three-dimensional finite element studies. The search for articles was performed in the PubMed/Medline database up to November 2021. The selected articles were independently evaluated by two different reviewers. The information collected was author and year of publication, dimensions of implants used, the material used in the prosthetic crown, simulated force and direction, and conclusion and effect. After searching, 14 studies were selected for full reading, and based on the inclusion and exclusion criteria, all could be included in this review. The articles were based on evidence-based laboratory medicine. After analyzing these articles, it was concluded that the prosthetic materials used on the occlusal surface do not interfere with the destruction of stresses to the bone and peri-implant tissue, both in single prostheses and protocol-type prostheses, when three-dimensional finite element method is used.

14.
J Prosthodont ; 32(6): 497-504, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36573906

RESUMO

PURPOSE: To assess the reproducibility of four different centric relation (CR) recording techniques, and time spent performing each technique in edentulous individuals. MATERIALS AND METHODS: Four techniques were assessed: extraoral gothic arch (EOGA) tracing, intraoral gothic arch (IOGA) tracing, deglutition (D), and frontal manipulation with tongue elevation (FMTE). Twelve subjects participated in the study; four technique records were performed on each volunteer by the same operator. Each record was repeated three times, in the same period of the day, with a 30 min interval between each technique. The reproducibility of each technique was assessed by the tri-dimensional displacement of the position of the condylar housing (mandible condyle) to the wall of the condylar guide (glenoid cavity) in the semi-adjustable articulator (anteroposterior, mediolateral, and superior-inferior). The time spent on each technique was timed in seconds (from the beginning of each technique until the wax occlusion fixation). The analysis of variance (ANOVA) and the Tukey test were performed for anteroposterior displacement (two-way) and for time spent on CT recording techniques (one-way) (α < 0.05). Regarding mediolateral and superior-inferior displacements, the nonparametric Kruskal-Wallis was performed for the comparison between recording methods, whereas the Mann-Whitney test was performed for the comparison between sides (α < 0.05). RESULTS: The factor recording technique interfered with the anteroposterior displacement (ANOVA: α < 0.001; F = 11.396). The technique D (right side: 3.78 ± 0.69 mm; left side: 3.45 ± 0.74 mm) showed a statistically significant difference compared to the other techniques (EOGA: right side: 3.00 ± 0.00 mm; left side: 3.00 ± 0.00 mm; FMTE: right side: 2.81 ± 0.52 mm; left side: 2.82 ± 0.79 mm; IOGA: right side: 2.90 ± 0.65 mm; left side: 3.12 ± 0.44 mm). The time spent on the recording technique influenced the results (ANOVA: α < 0.001; F = 21.118). The IOGA (340.40 ± 163.41 s) and EOGA (285.93 ± 133.84 s) required more time compared to the D (86.00 ± 34.33 s) and FMTE (101.33 ± 36.72 s) techniques. CONCLUSION: Graphic recordings showed better reproducibility and accuracy of the position of the centric relation.


Assuntos
Boca Edêntula , Humanos , Relação Central , Registro da Relação Maxilomandibular/métodos , Reprodutibilidade dos Testes , Estudos Transversais , Côndilo Mandibular
15.
Eur J Dent ; 17(2): 261-269, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36220125

RESUMO

An increase in the use of Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) technologies challenges the conventional prosthetic fabrication procedures that are practical and centered on a digital workflow for the patient, especially for dental implants. Increasing workflow of digital restoration work, considering computer-used CAM for restoration technology systems and also fast/CAM for building restoration technology; fast/CAD, also known as abut-Base, has increased interest. Studies on adaptation of different restorative materials, on titanium (Ti)-base abutments, traction, and transformed cycling have become relevant. The objective of this work was to research, through literature studies, on restoration-type abutments. A total of 24 articles were found after searching the following terms in PubMed/Medline, Scopus, and Embase databases: "ti-base AND abutment." Twenty-one manuscripts selected from the inclusion and exclusion criteria. After an analysis of these articles, it was concluded that the Ti-base abutment and components from the same manufacturer as the Implant should be used preferably; milled monolithic crowns designed to adapt to the Ti-base the hybrid abutment-crown assembly does not affect torque maintenance after thermal aging; the saliva and cleaning protocol of the Ti-base bonding surfaces can influence the operations of the Ti-base crowns; Ti-base and Crown surface treatment is recommended for better applicability and stability results, and the superiority of resin-based cements compared with other types of cements.

16.
Eur J Dent ; 17(3): 735-739, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36162430

RESUMO

OBJECTIVE: The aim of the study is to evaluate the effect of extrinsic pigmentation on the dimensional stability, hardness, detail reproduction, and color of a silicone after thermocycling. MATERIALS AND METHODS: Sixty samples of MDX4-4210 silicone (Dow Corning Corporation Medical Products) with intrinsic pink pigment (H-109-P, Factor II) and intrinsic opacifier (TiO) were fabricated. Two groups were created: Group 1-only intrinsic pigmentation (H-109P, Factor II + TiO) (Control); and Group 2-intrinsic (H-109P, Factor II + TiO) and extrinsic (Tan FE - 215, Factor II) pigmentation. The following tests were performed for each group: dimensional stability, Shore A hardness, detail reproduction, and color. Readings for the tests were taken before and after thermocycling (2,000 cycles). For dimensional stability and hardness, two-way analysis of variance (ANOVA) was used. One-way ANOVA was used for the color test. In case of significant statistical difference, the Tukey test was applied (p <0.05). All samples achieved the same detail reproduction score, therefore, no statistical evaluation was performed. RESULTS: For the dimensional stability test, comparing the initial time with the final time, there was a significant contraction in both groups after thermocycling. For the hardness test, comparing the time points, only group 1 showed a significant reduction in hardness after thermocycling. Groups 1 and 2 scored 2 for the detail reproduction test, before and after thermocycling. Comparing group 1 with group 2, there was no significant difference for color change. CONCLUSION: Based on the tests performed, extrinsic pigmentation did not show a negative effect on silicone, and therefore it can be indicated. The results of the dimensional, hardness, detail reproduction and color evaluations of the MDX4-4210 silicone were clinically acceptable in all cases in the groups with and without extrinsic pigmentation.

17.
Braz. dent. j ; 34(6): 1-9, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528035

RESUMO

Abstract In this study, we aimed to evaluate the halitosis and pain threshold of the peri-implant soft tissues in individuals rehabilitated with implant-supported prostheses. Forty-eight subjects were divided into four groups (n = 12) according to their prosthetic rehabilitation: single-tooth fixed prosthesis, multi-tooth fixed prosthesis, overdentures, and the Brånemark protocol. Halitosis was measured using a halimeter, whereas the pain threshold was measured using Von Frey monofilaments. Measurements were taken before (t0) and 30 days after (t1) placement of healing caps, and at the time of (t2) and 30 days after (t3) prosthetic placement. Halitosis data were analyzed using the chi-square test and Bonferroni correction (p < 0.05). Two-way ANOVA and Tukey's test (p < 0.05) were used to analyze pain threshold data. We noted an association between halitosis and time for the Brånemark protocol [X2(6) = 18.471; p = 0.005] and overdenture groups [X2(6) = 17.732; p = 0.007], and between halitosis and type of prosthesis only at t0 [X2(6) = 12.894; p = 0.045]. The interaction between time and the type of prosthesis significantly interfered with the mean pain threshold values (p = 0.001). At most time points, the majority of participants in each group had clinically unacceptable halitosis. After 30 days of using the prostheses, the overdenture group had a lower pain threshold compared to the Brånemark protocol group.


Resumo Este estudo teve como objetivo avaliar a halitose e o limiar de dor dos tecidos moles peri-implantares em indivíduos reabilitados com próteses implantossuportadas. Um total de 48 indivíduos foram divididos em quatro grupos (n=12), de acordo com as reabilitações: prótese fixa unitária, prótese fixa multidentária, sobredentadura e protocolo de Brånemark. A halitose foi medida com um halímetro, enquanto o limiar de dor foi medido com monofilamentos de von Frey. As medições foram feitas antes (t0) e 30 dias após (t1) a colocação das tampas de cicatrização e no momento (t2) e 30 dias após (t3) a colocação da prótese. Os dados de halitose foram analisados por meio do teste qui-quadrado e correção de Bonferroni (p < 0,05). ANOVA de duas vias e o teste de Tukey (p < 0,05) foram usados para analisar os dados do limiar de dor. Observou-se associação entre halitose e tempo para o protocolo de Brånemark [X2(6) = 18,471; p = 0,005] e grupos overdenture [X2(6) = 17,732; p = 0,007], e entre halitose e tipo de prótese apenas em t0 [X2(6) = 12,894; p = 0,045]. A interação entre o tempo e o tipo de prótese interferiu significativamente nos valores médios do limiar de dor (p = 0,001). Na maioria dos pontos de tempos, a maioria dos participantes de cada grupo apresentava halitose clinicamente inaceitável. Após 30 dias de uso das próteses, o grupo overdenture apresentou menor limiar de dor em comparação ao grupo do protocolo de Brånemark.

18.
Polim Med ; 52(2): 93-99, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36504451

RESUMO

BACKGROUND: Temporary prosthesis protects the oral tissues, in addition to providing aesthetic look and masticatory function until a definitive prosthesis is manufactured. OBJECTIVES: To evaluate the effect of glaze and 0.12% chlorhexidine (CHX) on the physical and mechanical properties of bis-acryl, and to evaluate the antimicrobial efficacy of CHX. MATERIAL AND METHODS: Eighty specimens of bis-acryl resin were made. Over 40 of them the glaze was applied. One specimen with and 1 specimen without glaze were placed in niches of an appliance manufactured for each patient. Each of the 20 volunteers received 2 devices. Initially, the volunteers used one device and treated it with sucrose for 7 days (control), and later they used the other device and treated it with sucrose and CHX for 7 days (test). Color, microhardness, roughness, surface energy, and insoluble extracellular polysaccharides (EPS) tests were performed. All results were submitted to the Tukey's test, with the exception of the EPS results, which were submitted to the Student's t test. RESULTS: The ΔE00 of the unglazed control group was significantly higher than that of the unglazed test group. In all groups, a significant decrease in microhardness occurred over time. At both times, the glaze significantly increased the microhardness of the specimens (in all the glazed groups). At the final time, the test glaze group showed significantly higher microhardness compared with the control glaze group. Roughness in the groups without glaze increased significantly with CHX treatment over time. At both times, the glaze generated a significant reduction in roughness in the control and test groups. There was a significant reduction in surface energy over time in all groups. In most comparisons, the glazed groups showed significantly higher surface energy values compared with the unglazed control group. At the final time point, the unglazed test group showed a significantly higher surface energy value than the unglazed control group; and the glazed test group showed a significantly higher surface energy value compared with the glazed control group. The resins that received CHX had a significantly lower amount of biofilm. CONCLUSIONS: Color values were clinically acceptable in all tested groups. At both time points, the roughness values were clinically acceptable only in the glazed groups. Glaze increased the microhardness of the specimens. Microhardness and surface energy were reduced over time in all groups. Chlorhexidine can help prevent microhardness degradation. Glaze and CHX can increase surface energy. Chlorhexidine reduced the amount of bacterial biofilm.


Assuntos
Resinas Acrílicas , Clorexidina , Humanos , Clorexidina/farmacologia , Próteses e Implantes , Biofilmes , Propriedades de Superfície , Teste de Materiais
19.
Antibiotics (Basel) ; 11(11)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36358141

RESUMO

Irritation and biofilm adhesion are complaints associated with ocular prosthesis use. This study aimed to evaluate the effects of prosthesis repolishing on several conditions of anophthalmic volunteers. Participants were divided into two groups: intervention (IG, n = 10) and nonintervention (NIG, n = 6) groups. The anophthalmic cavity, contralateral eye, and prosthesis surface were evaluated at initial, day 15, and day 30 after repolishing. Microbiological analysis (colony-forming units), exfoliative cytology (conjunctiva inflammatory cells), sensory analysis (quantitative mechanical sensory test), tear production (Schirmer's test), and conjunctival inflammation (clinical evaluation) were performed. Nonparametric tests were used to compare groups in the initial period and to analyze periods for the IG (p < 0.05). More microorganisms were formed in the anophthalmic socket and prosthesis than in the contralateral eye in the initial period. For IG, the anophthalmic cavity exhibited more microorganisms and inflammatory clinical signs in the initial period than at 15 and 30 after repolishing. The prosthesis showed greater accumulations of total bacteria and Candida albicans in the initial period than at 15 and 30 days after repolishing. The anophthalmic cavity had more palpebral inflammation than the contralateral eye. In conclusion, repolishing reduced the number of microorganisms and inflammatory signs over time.

20.
Rev. Odontol. Araçatuba (Impr.) ; 43(2): 49-54, maio-ago. 2022.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1362035

RESUMO

Overdenture é uma prótese total que se caracteriza por usar apoios retentivos para que aumente sua estabilidade e retenção na cavidade bucal, gerando assim menor desconforto ao paciente e melhor adaptação. A Prótese overdenture dentossuportada necessita de elementos dentais remanescentes com canais tratados endodonticamente e que possuam suporte periodontal adequado. O objetivo deste relato de caso clínico é expor a sequência de confecção de uma prótese overdenture dentossuportada maxilar associada a uma prótese total convencional mandibular, com os passos clínicos detalhados por meio de uma abordagem teórica e visual. Esse tipo de reabilitação favorece a adaptação do paciente à nova condição, visto que o uso de próteses totais convencionais pode causar certo desconforto ao paciente devido à falta de retenção e estabilidade. Essa manutenção dos dentes remanescentes favorece à manutenção óssea e a futura decisão do paciente em optar pela instalação de implantes dentários, podendo confeccionar próteses implantorretidas (overdentures) ou implantossuportadas (protocolo).O Paciente demonstrou-se satisfeito com o resultado estético e funcional após a instalação da prótese concretizando que o tratamento é viável(AU)


Overdenture is a denture that utilizing retentive supports for increase stability and retention in oral cavity. The tooth-supported overdenture require dental elements with root canal therapy and good periodontal support. The aim of this study is to report the confection of a maxillary tooth-supported overdenture associated with mandibular denture and your clinical steps. This rehabilitation promotes the patient's adaptation the new condition, since the use of conventional dentures may cause discomfort due to lack of retention and stability. The preservation of dental elements promotes bone maintenance and forthcoming decision of the patient in the installation of dental implants that can choose implantretained or implant-supported prosthesis. Patient was satisfied with aesthetic and functional result after installation of prosthesis(AU)


Assuntos
Humanos , Masculino , Retenção de Dentadura , Prótese Total , Revestimento de Dentadura , Retenção em Prótese Dentária , Prótese Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA