Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(4): 785-793, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383981

RESUMO

INTRODUCTION: Wearable cardioverter defibrillator (WCD) is utilized in patients with assumed but not yet confirmed risk for sudden cardiac death (SCD). Many of these patients also present with atrial fibrillation (AF). However, the rate of WCD-detected ventricular or atrial arrhythmia events in this specific high-risk cohort is not well understood. METHODS: In WEARIT-II, the cumulative probability of any sustained or nonsustained VT/VF (WCD-treated and nontreated), and atrial/supraventricular arrhythmias during WCD use was assessed using the Kaplan-Meier method by prior AF, with comparisons by the log-rank test. The incidence of ventricular and atrial arrhythmia events were expressed as events per 100 patient-years, and were analyzed by prior AF using negative binomial regression. RESULTS: WEARIT-II enrolled 2000 patients, 557 (28%) of whom had AF before enrollment. Cumulative probability of any sustained or nonsustained WCD-detected VT/VF during WCD use was significantly higher among patients with a history of AF than without AF (6% vs. 3%, p = .001). Similarly, the recurrent rate of any sustained or nonsustained VT/VF was significantly higher in patients with prior AF versus no prior AF (131.5 events per 100 patient-years vs. 22.7 events per 100 patient-years, p = .001). Patients with prior AF also had a significantly higher burden of any WCD-detected atrial arrhythmias/SVT/inappropriate arrhythmias therapy (183.2 events per 100 patient-years vs. 74.8 events per 100 patient-years, p < .001). CONCLUSION: Our results demonstrate that patients with a history of AF wearing the WCD for risk assessment have a higher incidence of ventricular arrhythmias that may facilitate the decision making for ICD implantation.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cardioversão Elétrica/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Medição de Risco , Sistema de Registros , Desfibriladores Implantáveis/efeitos adversos
2.
J Am Heart Assoc ; 13(3): e028902, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38240206

RESUMO

BACKGROUND: Sex-specific risk management may improve outcomes in congenital long QT syndrome (LQTS). We recently developed a prediction score for cardiac events (CEs) and life-threatening events (LTEs) in postadolescent women with LQTS. In the present study, we aimed to develop personalized risk estimates for the burden of CEs and LTEs in male adolescents with potassium channel-mediated LQTS. METHODS AND RESULTS: The prognostic model was derived from the LQTS Registry headquartered in Rochester, NY, comprising 611 LQT1 or LQT2 male adolescents from age 10 through 20 years, using the following variables: genotype/mutation location, QTc-specific thresholds, history of syncope, and ß-blocker therapy. Anderson-Gill modeling was performed for the end point of CE burden (total number of syncope, aborted cardiac arrest, and appropriate defibrillator shocks). The applicability of the CE prediction model was tested for the end point of the first LTE (excluding syncope and adding sudden cardiac death) using Cox modeling. A total of 270 CEs occurred during follow-up. The genotype-phenotype risk prediction model identified low-, intermediate-, and high-risk groups, comprising 74%, 14%, and 12% of the study population, respectively. Compared with the low-risk group, high-risk male subjects experienced a pronounced 5.2-fold increased risk of recurrent CEs (P<0.001), whereas intermediate-risk patients had a 2.1-fold (P=0.004) increased risk . At age 20 years, the low-, intermediate-, and high-risk adolescent male patients had on average 0.3, 0.6, and 1.4 CEs per person, respectively. Corresponding 10-year adjusted probabilities for a first LTE were 2%, 6%, and 8%. CONCLUSIONS: Personalized genotype-phenotype risk estimates can be used to guide sex-specific management in male adolescents with potassium channel-mediated LQTS.


Assuntos
Síndrome do QT Longo , Canais de Potássio , Humanos , Masculino , Adolescente , Feminino , Adulto Jovem , Adulto , Criança , Canais de Potássio/genética , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/genética , Síndrome do QT Longo/congênito , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Síncope/genética , Síncope/epidemiologia , Genótipo , Fatores de Risco , Medição de Risco , Eletrocardiografia
3.
JACC Clin Electrophysiol ; 10(1): 16-26, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38032575

RESUMO

BACKGROUND: There are conflicting data on the effect of cardiac resynchronization therapy with a defibrillator (CRT-D) on the risk of life-threatening ventricular tachyarrhythmia in heart failure patients. OBJECTIVES: The authors aimed to assess whether QRS morphology is associated with risk of ventricular arrhythmias in CRT recipients. METHODS: The study population comprised 2,862 patients implanted with implantable cardioverter defibrillator (ICD)/CRT-D for primary prevention who were enrolled in 5 landmark primary prevention ICD trials (MADIT-II [Multicenter Automated Defibrillator Implantation Trial], MADIT-CRT [Multicenter Automated Defibrillator Implantation Trial-Cardiac Resynchronization Therapy], MADIT-RIT [Multicenter Automated Defibrillator Implantation Trial-Reduction in Inappropriate Therapy], MADIT-RISK [Multicenter Automated Defibrillator Implantation Trial-RISK], and RAID [Ranolazine in High-Risk Patients With Implanted Cardioverter Defibrillators]). Patients with QRS duration ≥130 ms were divided into 2 groups: those implanted with an ICD only vs CRT-D. The primary endpoint was fast ventricular tachycardia (VT)/ventricular fibrillation (VF) (defined as VT ≥200 beats/min or VF), accounting for the competing risk of death. Secondary endpoints included appropriate shocks, any sustained VT or VF, and the burden of fast VT/VF, assessed in a recurrent event analysis. RESULTS: Among patients with left bundle branch block (n = 1,792), those with CRT-D (n = 1,112) experienced a significant 44% (P < 0.001) reduction in the risk of fast VT/VF compared with ICD-only patients (n = 680), a significantly lower burden of fast VT/VF (HR: 0.55; P = 0.001), with a reduced burden of appropriate shocks (HR: 0.44; P < 0.001). In contrast, among patients with non-left bundle branch block (NLBBB) (N = 1,070), CRT-D was not associated with reduction in fast VT/VF (HR: 1.33; P = 0.195). Furthermore, NLBBB patients with CRT-D experienced a statistically significant increase in the burden of fast VT/VF events compared with ICD-only patients (HR: 1.90; P = 0.013). CONCLUSIONS: Our data suggest a potential proarrhythmic effect of CRT among patients with NLBBB. These data should be considered in patient selection for treatment with CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/terapia
4.
J Clin Med ; 12(20)2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37892833

RESUMO

Aim To compare the 1-year survival rate of patients with atrial fibrillation (AF) following left atrial appendage occluder (LAAO) implantation vs. treatment with novel oral anticoagulants (NOACs). METHODS: We have conducted an indirect, retrospective comparison between LAAO and NOAC registries. The LAAO registry is a national prospective cohort of 419 AF patients who underwent percutaneous LAAO between January 2008 and October 2015. The NOACs registry is a multicenter prospective cohort of 3138 AF patients treated with NOACs between November 2015 and August 2018. Baseline patient characteristics were retrospectively collected from coded diagnoses of hospitalization and outpatient clinic notes. Follow-up data was sorted from coded diagnoses and the national civil registry. Subjects were matched according to propensity score. Baseline characteristics were compared using Chi-Square and student's t-test. Survival analysis was performed using Kaplan-Meier survival curves, log-rank test, and multivariable Cox regression, adjusting for possible confounding variables. RESULTS: This study included 114 subjects who underwent LAAO implantation and 342 subjects treated with NOACs. The mean age of participants was 77.9 ± 7.44 and 77.1 ± 11.2 years in the LAAO and NOAC groups, respectively (p = 0.4). The LAAO group had 70 (61%) men compared to 202 (59%) men in the NOAC group (p = 0.74). No significant differences were found in baseline comorbidities, renal function, or CHA2DS2-VASc score. One-year mortality was observed in 5 (4%) patients and 32 (9%) patients of the LAAO and NOAC groups, respectively. After adjusting for confounders, LAAO was significantly associated with a lower risk for 1-year mortality (HR 0.38, 95%CI 0.14-0.99). In patients with impaired renal function, this difference was even more prominent (HR 0.21 for creatinine clearance (CrCl) < 60 mL/min). CONCLUSIONS: In a pooled analysis of two registries, we found a significantly lower risk for 1-year mortality in patients with AF who were implanted with LAAO than those treated with NOACs. This finding was more prominent in patients with impaired renal function. Future prospective direct studies should further investigate the efficacy and adverse effects of both treatment strategies.

5.
Clin Res Hepatol Gastroenterol ; 47(9): 102221, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37774920

RESUMO

BACKGROUND: This retrospective study investigated the impact of hemochromatosis on maternal and perinatal outcomes among delivery hospitalizations in the United States between 2010 and 2019, revealing notable trends and associations. METHODS: Utilizing data from over 36 million delivery hospitalizations, we conducted a comprehensive analysis, focusing on maternal complications, perinatal outcomes, and healthcare utilization among women with hemochromatosis compared to those without. RESULTS: Women with hemochromatosis exhibited a longer length of hospital stay (3.27 ± 0.20 days vs. 2.64 ± 0.04 days) and higher total hospital charges ($21,789.66 ± $1124.41 vs. $17,751.63 ± $97.71) compared to those without the condition. There was a significant increase in the prevalence of hemochromatosis among delivery hospitalizations over the studied period, from 1.91 per 100,000 hospitalizations to 8.65 cases per 100,000 hospitalizations. Hemochromatosis patients demonstrated a higher prevalence of hypertensive disorders of pregnancy (aOR: 1.50, 95 % CI: 1.03-2.19) and VTE(aOR: 20.35, 95 % CI: 5.05-82.05).There were no statistically significant differences in rates of peripartum hemorrhage, C-section, preterm birth, fetal growth restriction, large for gestational age infants, and fetal death between the two groups. CONCLUSIONS: Our findings underscore higher hypertensive disorders of pregnancy and VTE among women with hemochromatosis, despite unaffected perinatal outcomes. An increasing trend in hemochromatosis prevalence highlights the need for targeted interventions and cost-effective management strategies. Future research is needed to explore potential racial disparities and understand the rising incidence of hemochromatosis among pregnant women.


Assuntos
Hemocromatose , Hipertensão Induzida pela Gravidez , Nascimento Prematuro , Tromboembolia Venosa , Lactente , Gravidez , Recém-Nascido , Feminino , Humanos , Hemocromatose/complicações , Hemocromatose/epidemiologia , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/etiologia , Estudos Retrospectivos
6.
Front Cardiovasc Med ; 10: 1237118, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37680559

RESUMO

Introduction: The implantable cardioverter defibrillator (ICD) is effective for the prevention of sudden cardiac death (SCD) in patients with heart failure and a reduced ejection fraction (HFrEF). The benefit of the ICD in patients with advanced CKD, remains elusive. Moreover, the benefit of the ICD in patients with advanced chronic kidney disease (CKD) and HFrEF who are cardiac resynchronization therapy (CRT) recipients may be attenuated. Hypothesis: We hypothesized that patients with CKD who are CRT recipients may derive less benefit from the ICD due to the competing risk of dying prior to experiencing an arrhythmia. Methods: The study population included 1,015 patients receiving CRT with defibrillator (CRT-D) device for primary prevention of SCD who were enrolled in either (Multicenter Automated Defibrillator Implantation Trial) MADIT-CRT trial or the Ranolazine in High-Risk Patients with Implanted Cardioverter Defibrillator (RAID) trial. The cohort was divided into two groups based on the stage of CKD: those with Stage 1 to 3a KD, labeled as (S1-S3a)KD. The second group included patients with Stage 3b to stage 5 kidney disease, labeled as (S3b-S5)KD. The primary endpoint was any ventricular tachycardia (VT) or ventricular fibrillation (VF) (Any VT/VF). Results: The cumulative incidence of Any VT/VF was 23.5% in patients with (S1-S3a)KD and 12.6% in those with (S3b-S5)KD (p < 0.001) The incidence of Death without Any VT/VF was 6.6% in patients with (S1-S3a)KD and 21.6% in patients with (S3b-S5)KD (p < 0.001). A Fine and Gray multivariate competing risk regression model showed that Patients with (S3b-S5)KD had a 43% less risk of experiencing Any VT/VF when compared to those with (S1-S3a)KD (HR = 0.56, 95% CI [0.33-0.94] p = 0.03. After two years of follow up, there was almost a 5-fold increased risk of Death without Any VT/VF among patients with (S3b-S5)KD when compared to those with (S1-S3a)KD [HR = 4.63, 95% CI (2.46-8.72), p for interaction with time = 0.012]. Conclusion: Due to their lower incidence of arrhythmias and higher risk of dying prior to experiencing an arrhythmia, the benefit of the ICD may be attenuated in CRT recipients with advanced CKD. Future prospective trials should evaluate whether CRT without a defibrillator may be more appropriate for these patients.

7.
JACC Clin Electrophysiol ; 9(10): 2122-2131, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37656097

RESUMO

BACKGROUND: Both selective and nonselective beta-blockers are used to treat patients with heart failure (HF). However, the data on the association of beta-blocker type with risk of atrial arrhythmia and ventricular arrhythmia (VA) in HF patients with a primary prevention implantable cardioverter-defibrillator (ICD) are limited. OBJECTIVES: This study sought to evaluate the effect of metoprolol vs carvedilol on the risk of atrial tachyarrhythmia (ATA) and VA in HF patients with an ICD. METHODS: This study pooled primary prevention ICD recipients from 5 landmark ICD trials (MADIT-II, MADIT-CRT, MADIT-RIT, MADIT-RISK, and RAID). Fine and Gray multivariate regression models, stratified by study, were used to evaluate the risk of ATA, inappropriate ICD shocks, and fast VA (defined as ventricular tachycardia ≥200 beats/min or ventricular fibrillation) by beta-blocker type. RESULTS: Among 4,194 patients, 2,920 (70%) were prescribed carvedilol and 1,274 (30%) metoprolol. The cumulative incidence of ATA at 3.5 years was 11% in patients treated with carvedilol vs 15% in patients taking metoprolol (P = 0.003). Multivariate analysis showed that carvedilol treatment was associated with a 35% reduction in the risk of ATA (HR: 0.65; 95% CI: 0.53-0.81; P < 0.001) when compared to metoprolol, and with a corresponding 35% reduction in the risk of inappropriate ICD shocks (HR: 0.65; 95% CI: 0.47-0.89; P = 0.008). Carvedilol vs metoprolol was also associated with a 16% reduction in the risk of fast VA. However, these findings did not reach statistical significance (HR: 0.84; 95% CI: 0.70-1.02; P = 0.085). CONCLUSIONS: These findings suggests that HF patients with ICDs on carvedilol treatment experience a significantly lower risk of ATA and inappropriate ICD shocks when compared to treatment with metoprolol.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Metoprolol/uso terapêutico , Carvedilol/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Atrial/induzido quimicamente , Antagonistas Adrenérgicos beta/efeitos adversos , Insuficiência Cardíaca/complicações
8.
Circulation ; 148(3): 241-252, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37459413

RESUMO

BACKGROUND: Black Americans have a higher risk of nonischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate differences in the risk of tachyarrhythmias among patients with an implantable cardioverter-defibrillator (ICD). METHODS: The study population comprised 3895 ICD recipients in the United States enrolled in primary prevention ICD trials. Outcome measures included ventricular tachyarrhythmia (VTA), atrial tachyarrhythmia (ATA), ICD therapies, VTA burden (using Andersen-Gill recurrent event analysis), death, and the predicted benefit of the ICD. All events were adjudicated blindly. Outcomes were compared between self-reported Black patients versus White patients with cardiomyopathy (ischemic and NICM). RESULTS: Black patients were more likely to be female (35% versus 22%) and younger (57±12 versus 62±12 years) with a higher frequency of comorbidities. In NICM, Black patients had a higher rate of first VTA, fast VTA, ATA, and appropriate and inappropriate ICD therapy (VTA ≥170 bpm, 32% versus 20%; VTA ≥200 bpm, 22% versus 14%; ATA, 25% versus 12%; appropriate therapy, 30% versus 20%; and inappropriate therapy, 25% versus 11%; P<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia or ICD therapy (VTA ≥170 bpm, hazard ratio [HR] 1.71; VTA ≥200 bpm, HR 1.58; ATA, HR 1.87; appropriate therapy, HR 1.62; inappropriate therapy, HR 1.86; P≤0.01 for all), higher burden of tachyarrhythmias or therapies (VTA, HR 1.84; appropriate therapy, HR 1.84; P<0.001 for both), and a higher risk of death (HR 1.92; P=0.014). In contrast, in ischemic cardiomyopathy, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black patients and White patients. Both Black patients and White patients derived a significant and similar benefit from ICD implantation. CONCLUSIONS: Among patients with NICM with an ICD for primary prevention, Black patients compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies with a lower survival rate. Nevertheless, the overall benefit of the ICD was maintained and was similar to that of White patients.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Feminino , Estados Unidos/epidemiologia , Masculino , Brancos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco , Arritmias Cardíacas , Taquicardia Ventricular/terapia , Taquicardia Ventricular/epidemiologia , Prevenção Primária
9.
medRxiv ; 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37205384

RESUMO

Background: Black Americans have a higher risk of non-ischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate racial disparities in the risk of tachyarrhythmias among patients with an implantable cardioverter defibrillator (ICD). Methods: The study population comprised 3,895 ICD recipients enrolled in the U.S. in primary prevention ICD trials. Outcome measures included first and recurrent ventricular tachy-arrhythmia (VTA) and atrial tachyarrhythmia (ATA), derived from adjudicated device data, and death. Outcomes were compared between self-reported Black vs. White patients with a cardiomyopathy (ischemic [ICM] and NICM). Results: Black patients were more likely to be female (35% vs 22%) and younger (57±12 vs 62±12) with a higher frequency of comorbidities. Blacks patients with NICM compared with Whites patients had a higher rate of first VTA, fast VTA, ATA, appropriate-, and inappropriate-ICD-therapy (VTA≥170bpm: 32% vs. 20%; VTA≥200bpm: 22% vs. 14%; ATA: 25% vs. 12%; appropriate 30% vs 20%; and inappropriate: 25% vs. 11%; p<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia/ICD-therapy (VTA≥170bpm: HR=1.69; VTA≥200bpm: HR=1.58; ATA: HR=1.87; appropriate: HR=1.62; and inappropriate: HR=1.86; p≤0.01 for all), higher burden of VTA, ATA, ICD therapies, and a higher risk of death (HR=1.86; p=0.014). In contrast, in ICM, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black and White patients. Conclusions: Among NICM patients with an ICD for primary prevention, Black compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies. Clinical Perspective: What Is New?: Black patients have a higher risk of developing non-ischemic cardiomyopathy (NICM) but are under-represented in clinical trials of implantable cardioverter defibrillators (ICD). Therefore, data on disparities in the presentation and outcomes in this population are limited.This analysis represents the largest group of self-identified Black patients implanted in the U.S. with an ICD for primary prevention with adjudication of all arrhythmic events.What Are the Clinical Implications?: In patients with a NICM, self-identified Black compared to White patients experienced an increased incidence and burden of ventricular tachyarrhythmia, atrial tachyarrhythmia, and ICD therapies. These differenced were not observed in Black vs White patients with ischemic cardiomyopathy (ICM).Although Black patients with NICM were implanted at a significantly younger age (57±12 vs 62±12 years), they experienced a 2-fold higher rate of all-cause mortality during a mean follow up of 3 years compared with White patients.These findings highlight the need for early intervention with an ICD, careful monitoring, and intensification of heart failure and antiarrhythmic therapies among Black patients with NICM.

11.
Heart Rhythm ; 18(3): 404-410, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33248269

RESUMO

BACKGROUND: Data on the arrhythmic burden of women at risk for sudden cardiac death are limited, especially in patients using the wearable cardioverter-defibrillator (WCD). OBJECTIVE: We aimed to characterize WCD compliance, atrial and ventricular arrhythmic burden, and WCD outcomes by sex in patients enrolled in the Prospective Registry of Patients Using the Wearable Cardioverter Defibrillator (WEARIT-II U.S. Registry). METHODS: In the WEARIT-II Registry, we stratified 2000 patients by sex into women (n = 598) and men (n = 1402). WCD wear time, ventricular and atrial arrhythmic events during WCD use, and implantable cardioverter-defibrillator (ICD) implantation rates at the end of WCD use were evaluated. RESULTS: The mean WCD wear time was similar in women and men (94 days vs 90 days; P = .145), with longer daily use in women (21.4 h/d vs 20.7 h/d; P = .001). Burden of ventricular tachycardia or ventricular fibrillation was higher in women, with 30 events per 100 patient-years compared with 18 events per 100 patient-years in men (P = .017), with similar findings for treated and non-treated ventricular tachycardia/ventricular fibrillation. Recurrent atrial arrhythmias/sustained ventricular tachycardia was also more frequent in women than in men (167 events per 100 patient-years vs 73 events per 100 patient-years; P = .042). However, ICD implantation rate at the end of WCD use was similar in both women and men (41% vs 39%; P = .448). CONCLUSION: In the WEARIT-II Registry, we have shown a higher burden of ventricular and atrial arrhythmic events in women than in men. ICD implantation rates at the end of WCD use were similar. Our findings warrant monitoring women at risk for sudden cardiac death who have a high burden of atrial and ventricular arrhythmias while using the WCD.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Sistema de Registros , Medição de Risco/métodos , Dispositivos Eletrônicos Vestíveis , Arritmias Cardíacas/complicações , Arritmias Cardíacas/epidemiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente , Estudos Prospectivos , Distribuição por Sexo , Fatores Sexuais , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
12.
Europace ; 22(9): 1384-1390, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32875313

RESUMO

AIMS: Patients with impaired renal function were shown to have an attenuated benefit from implantable cardioverter-defibrillator. However, there are limited data on the competing risk of ventricular arrhythmia events and death by renal function in patients without severe disease. Therefore, we aimed to assess the competing risk of ventricular arrhythmia events and death by renal function. METHODS AND RESULTS: We analysed 1782 patients (99%) enrolled in Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) with glomerular filtration rate (GFR) data available. Cumulative incidence function curves were used to display the rate of ventricular tachycardia (VT), ventricular fibrillation (VF), and the competing risk of death without experiencing VT/VF. Multivariable Fine and Gray regression models and recurrent event analysis were performed. There were 355 (20%) patients with GFR < 52 and 1427 with GFR ≥ 52 (lowest quintile). The incidence of non-fatal VT/VF at 4 years was higher in patients with high GFR (26%) as compared to low GFR (16%), whereas rates of death without non-fatal VT/VF were 5% and 20% (P < 0.001). In Fine and Gray models, the low GFR group was 35% less likely to experience VT/VF compared to the high GFR [95% confidence interval (CI) 0.48-0.88, P = 0.005]. In contrast,death without experiencing VT/VF was 3.5-fold higher in the low GFR group (95% CI 2.38-5.12, P-value < 0.001). Recurrent event analysis consistently showed a lower risk of recurrent VT/VF, recurrent anti-tachycardia pacing only, and shock in the low GFR group. CONCLUSIONS: We show, in a competing risk model, a lower risk of VT/VF events and a higher risk of mortality without an arrhythmic event in patients with moderate renal dysfunction in MADIT-CRT. These findings can be used for improved selection of patients for defibrillator therapy among CRT candidates. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT00180271.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Nefropatias , Taquicardia Ventricular , Arritmias Cardíacas/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/terapia
13.
Pacing Clin Electrophysiol ; 43(12): 1495-1500, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32579238

RESUMO

BACKGROUND: We aimed to characterize the hourly, daily, and seasonally variations in the detection of new atrial fibrillation (AF) in heart failure patients implanted with a defibrillator. METHODS: In 1309 patients enrolled in MADIT-RIT without AF at baseline, atrial arrhythmia data were analyzed from device interrogations. The circadian, weekly, and seasonal distribution of device detected AF was evaluated. The morning period was defined as 06:00-11:59, afternoon as 12:00-16:59, evening as 17:00-22:59, and the nighttime as 23:00-05:59. RESULTS: During 17 months of follow-up, 66 (5%) patients developed new device-detected AF. AF patients were less likely to have ischemic cardiomyopathy and were more likely to have received an implantable cardioverter defibrillator rather than a cardiac resynchronization therapy with defibrillator. The highest number of AF occurred during the evening hours (25 patients [38%]) followed by a second peak in AF detection during the afternoon hours (21 patients [32%]). Importantly during the nighttime, new AF occurred only in three patients (4%). In comparison with the nighttime period, the odds ratio (OR) of developing AF during the evening time period was 8.5-fold higher (95% CI 7.3-9.7, P < .01). Detection of AF during the spring and winter seasons accounted for 67% of all new device-detected AF. CONCLUSIONS: There is diurnal and seasonal variation in new onset AF. A double peak in the incidence of AF is observed during the afternoon and evening hours, and during the spring and winter seasons. This information may be useful when deciding when to screen at-risk patients for new AF.


Assuntos
Fibrilação Atrial/diagnóstico , Ritmo Circadiano , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Estações do Ano , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Europace ; 21(3): 459-464, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30689821

RESUMO

AIMS: Heart failure patients with advanced chronic kidney disease (CKD) may experience an increased rate of non-arrhythmic mortality due to associated comorbidities. We aimed to evaluate the risk of mortality without appropriate implantable cardioverter-defibrillator (ICD) shocks in this high-risk population. METHODS AND RESULTS: The study population comprised 3542 patients who received an ICD, were enrolled, and prospectively followed-up in the Israeli ICD registry. Study patients were categorized into two groups: those with advanced CKD [defined by a glomerular filtration rate of <30 mL/min/1.73 m2 or being on dialysis at time of implantation (n = 197)], and those without advanced CKD (n = 3344). The primary endpoint was the risk of death without receiving appropriate ICD shock. Kaplan-Meier survival analysis showed that at 5 years of follow-up the rates of death without prior ICD shock were significantly higher in the advanced kidney disease group (46%) compared with the non-advanced CKD group (19%; log-rank P-value <0.001). Consistently, multivariate analysis showed that the risk of death without receiving appropriate ICD shock therapy at 5 years was 2.5-fold (P < 0.001) higher among advanced CKD patients. In contrast, the rate of appropriate ICD shock therapy at 5 years among advanced CKD patients was only 9%, with a very high mortality rate (63%) within 3.5 years subsequent to shock therapy. CONCLUSION: Nearly one-half of ICD with advanced CKD die within 5 years without receiving an appropriate ICD shock. These findings stress the importance of appropriate patient selection for primary ICD implantation in this high-risk population.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Taxa de Filtração Glomerular , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Rim/fisiopatologia , Insuficiência Renal Crônica/mortalidade , Idoso , Tomada de Decisão Clínica , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Diálise Renal , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/terapia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
Am J Cardiol ; 120(12): 2187-2192, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-29100590

RESUMO

Anemia was shown to be associated with increased risk for adverse events in patients with heart failure (HF). However, there are limited data on the association between anemia and the risk for ventricular arrhythmias (VAs) in patients with an implantable cardioverter defibrillator (ICD). The present study population comprised 2,352 patients who were enrolled and prospectively followed up in the Israeli ICD Registry. The risk for a first appropriate ICD shock for VA was assessed by the presence of anemia, categorized at the lower tertile of hemoglobin distribution (≤12 g/dL [n = 753]). Patients who had anemia displayed higher risk clinical characteristics including older age, more advanced HF symptoms, and atrial fibrillation (p <0.01 for all). Kaplan-Meier survival analysis showed that at 2.5 years of follow-up the rate of appropriate shocks was significantly higher in patients with low (11%) versus high (6%) hemoglobin (log-rank p <0.005). Multivariate analysis showed that anemia was independently associated with a significant 56% increased risk for first appropriate ICD shock (p <0.026). When hemoglobin was assessed as a continuous measure, each 1 g/dL reduction in hemoglobin was independently associated with a significant 8% increased risk for first appropriate shock (p <0.03). Anemia was also associated with increased risk for all-cause mortality (hazard ratio [HR] 1.78, 95% confidence interval [CI] 1.4 to 2.27], p <0.001), HF hospitalizations or death (HR 1.78, 95% CI 1.48 to 1.13, p <0.001), but not with inappropriate ICD shocks (HR 1.24, 95% CI 0.70 to 2.21, p = 0.47). In conclusion, our findings suggest that the presence of anemia in patients with ICD is associated with increased risk for VA during long-term follow-up.


Assuntos
Anemia/complicações , Desfibriladores Implantáveis , Sistema de Registros , Taquicardia Ventricular/terapia , Idoso , Anemia/sangue , Anemia/epidemiologia , Feminino , Seguimentos , Hemoglobinas/metabolismo , Humanos , Incidência , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Taxa de Sobrevida/tendências , Taquicardia Ventricular/complicações , Taquicardia Ventricular/epidemiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA