Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38749449

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

2.
JACC Cardiovasc Interv ; 15(2): 135-146, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35057983

RESUMO

OBJECTIVES: The aims of this study were to determine the rate of noncentered coronary ostia and their risk for coronary overlap (CO) and to develop an improved orientation strategy for transcatheter aortic valve replacement (TAVR) devices taking into account anatomical cues to identify patients at risk for CO regardless of commissural alignment and compute an alternative, CO-free TAVR rotation angle for those patients. BACKGROUND: Commissural alignment during TAVR reduces CO risk. However, eccentricity of coronary ostia from the center of the sinus of Valsalva may result in CO even after perfect alignment of TAVR commissures. METHODS: Baseline computed tomography from TAVR candidates helped identify distance from commissures to the right coronary artery (RCA) and the left coronary artery (LCA). Then, for each case, a virtual valve was simulated with ideal commissural or coronary alignment, and the degree of CO was determined. On the basis of the potential BASILICA (bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction) efficacy, 3 groups were defined: no risk for CO (>35° from neocommissure to coronary ostia), moderate risk (20°-35°), and severe risk (≤20°). RESULTS: Computed tomographic studies from 107 patients were included. After excluding 7 patients (poor quality or bicuspid valve), 100 patients were analyzed. The RCA showed greater eccentricity compared with the LCA (18.5° [IQR: 3.3°-12.8°] vs 6.5° [IQR: 3.3°-12.8°]; P < 0.001). The mean intercoronary angle was 140.0° ± 18.7° (95% CI: 136.3°-143.7°). Thirty-two patients had moderate to severe risk for CO (≤35°) despite ideal commissural alignment. Greater coronary eccentricity (cutoff for RCA, 24.5°; cutoff for LCA, 19°) and intercoronary angle >147.5° or <103° were associated with greater risk for moderate to severe CO despite commissural alignment (area under the curve: 0.97; 95% CI: 0.91-0.99). If optimal coronary alignment was simulated, this prevented severe CO in all cases and reduced moderate CO from 27% to 5% (P < 0.001). CONCLUSIONS: One third of patients would have CO during TAVR-in-TAVR despite commissural alignment; a 6-fold decrease in this risk was achieved with optimized coronary alignment. Coronary eccentricity and intercoronary angle were the main predictors.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA