Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1688: 463689, 2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36528901

RESUMO

Capillary gel electrophoresis (CGE) has been widely used for analysis of proteins according to their size. However, to our knowledge, this technique has not been optimized to immunoglobulin A (IgA) analysis, a protein of current and emerging high interest in several fields. IgA is the first barrier of human body against pathogens. This protein in human milk and colostrum is essential for immune protection of newborns and treatment of milk for storage in Human Milk Banks may alter IgA. The emerging use of IgA as therapeutic treatment also encourages the development of analysis methods for this class of immunoglobulins. IgA is far more heterogeneously glycosylated and complex than the well-studied IgG molecules. IgA in serum is mainly monomeric (mIgA) with about 160 kDa, while in secretions such as saliva, milk, colostrum, etc, secretory immunoglobulin A (sIgA) is the predominant form. This is a dimer where both monomers are linked by the J-chain and the secretory component accounting all together for a MW higher than 400 kDa including the glycans. This size is far from the 225 kDa MW for which commercial CGE kits are intended. The general rules governing CGE behavior of analytes cannot be directly applied to every protein. Addressing studies directed specifically to target proteins is specially needed for the large size and highly complex target analytes of this study. In this work the effect of several factors on CGE analysis of human serum and colostrum IgA is studied. The feasibility of performing analysis of both IgA classes using a commercial CGE kit is shown. In addition, this work introduces another novelty by preparing tailor-made reproducible gel buffers and to characterize them in terms of dynamic viscosity, conductivity, and electroosmotic flow mobility in bare fused silica capillaries. The possibility of analyzing mIgA and sIgA in less than 10 min using these tailor-made gels is demonstrated. Inter-day variation (RSD) for the main peak of sIgA is 0.25% for migration time (tm) and 0.27% for percentage corrected peak area (Acorr).


Assuntos
Capilares , Imunoglobulina A Secretora , Recém-Nascido , Feminino , Gravidez , Humanos , Imunoglobulina A Secretora/análise , Peso Molecular , Capilares/química , Imunoglobulina A , Colostro/química , Leite Humano/química , Glicoproteínas , Eletroforese Capilar
2.
Artigo em Inglês | MEDLINE | ID: mdl-27428985

RESUMO

Public health policies must address multiple goals and complex community health needs. Recently, management control practices have emerged to provide a broader type of information for evaluating the effectiveness of healthcare policies, and relate activities and processes to multiple strategic outcomes. This study compares the effect of traditional and contemporary management control practices on the achievement of public health policies. It is also analyzed how two different uses of such practices (enabling vs. coercive) facilitate the achievement of public health policies. Relationships are explored using data collected from managers from public health agencies and public hospitals in Spain. The findings show that contemporary management control practices are more suitable than traditional practices to achieve public health policies. Furthermore, results show that public health policies are better achieved when managers use management control practices in an enabling way rather than in a coercive way.


Assuntos
Política de Saúde , Administração em Saúde Pública/métodos , Acessibilidade aos Serviços de Saúde , Disparidades nos Níveis de Saúde , Humanos , Saúde Pública , Espanha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA