RESUMO
BACKGROUND AND IMPORTANCE: Partially thrombosed vertebral artery aneurysms (PTVAs) are rare, most of which are not easy to treat. Furthermore, endovascular treatment of PTVAs may not have favorable outcomes. The relationship between PTVAs and well-developed vasa vasorum (VV), including the mechanism of aneurysm growth, has been reported, but there are no reports of imaging findings by digital subtraction angiography (DSA). In this case, we successfully performed superselective angiography of well-developed VV and evaluated its imaging characteristics. We present the first DSA report of a well-developed VV of PTVA. CLINICAL PRESENTATION: A 54-year-old patient presented with a PTVA that exerted a mass effect on the medulla oblongata. The aneurysm had no cavity due to thrombosis. The 3-dimensional DSA images indicated VV. Superselective angiography of the VV indicated staining of the thrombosed aneurysm and draining into the suboccipital cavernous sinus through the venous VV. Thus, VV embolization with n-butyl cyanoacrylate was performed. After 3 months, the contrast effect of the aneurysm on contrast-enhanced magnetic resonance imaging disappeared and aneurysm shrinkage was observed. CONCLUSION: We successfully identified a VV within PTVA. Superselective VV angiography showed staining of the thrombosed component and venous return draining into the suboccipital cavernous sinus. In this case, the embolization of the VV proved to be an effective endovascular treatment of PTVA, but the safety of this method is a challenge. Further case studies are required to validate this method, and we hope it will evolve into a new treatment of PTVA.
RESUMO
OBJECTIVE: Transient neurological deficits (TNDs) are known to develop after direct bypass for Moyamoya disease and may be risk factors for subsequent stroke. However, the factors involved in the development of TNDs and stroke after indirect revascularization alone, including their association with subsequent stroke, remain unclear. The purpose of this study was to investigate this issue. METHODS: The subjects of the study were 30 patients with Moyamoya disease who underwent a total of 40 indirect revascularization procedures at our institution. Clinical and radiological data were collected retrospectively. To examine factors associated with the development of postoperative TND/stroke/asymptomatic disease, the clinical characteristics of each group were statistically compared. RESULTS: The mean age at surgery was 7 years (range 1-63). TNDs developed after surgery in 9 out of 40 patients (22.5%). Stroke in the acute postoperative period occurred in 3 patients (7.5%), all of whom experienced cerebral infarctions. Demographic data and preoperative clinical information were not different between the groups. However, posterior cerebral artery involvement on preoperative imaging was significantly associated with the development of TNDs and stroke (P = 0.006). Furthermore, postoperative stroke was associated with unfavorable outcomes (P = 0.025). CONCLUSIONS: Posterior cerebral artery involvement is significantly associated with the occurrence of TNDs. In contrast, TNDs after indirect revascularization have little relationship with the subsequent development of stroke. TNDs usually resolve without new strokes, and a better understanding of this particular pathology could help establish an optimal treatment regimen.
Assuntos
Revascularização Cerebral , AVC Isquêmico , Doença de Moyamoya , Artéria Cerebral Posterior , Complicações Pós-Operatórias , Humanos , Doença de Moyamoya/cirurgia , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/complicações , Feminino , Masculino , Revascularização Cerebral/efeitos adversos , Revascularização Cerebral/métodos , Adulto , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Adolescente , Estudos Retrospectivos , Criança , Adulto Jovem , Artéria Cerebral Posterior/diagnóstico por imagem , Artéria Cerebral Posterior/cirurgia , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/etiologia , AVC Isquêmico/cirurgia , Pré-Escolar , Lactente , Doenças do Sistema Nervoso/etiologia , Doenças do Sistema Nervoso/epidemiologia , Doenças do Sistema Nervoso/diagnóstico por imagemRESUMO
OBJECTIVE: Intracranial dural arteriovenous fistulae (DAVFs) represent a subset of cerebral vascular malformations associated with significant morbidity and mortality. In Japan, DAVF exhibits sex-based differences in anatomical distribution, with female predominance in the cavernous sinus (CS) and male predominance in the transverse sinus (TS). Nevertheless, the pathophysiology of DAVF is not fully understood, and hormonal influences are hypothesized to play a role in its development. This study aimed to investigate changes in the concentrations of sex steroid hormones between intracranial and peripheral sampling sites in patients with CS- and TS-DAVF. METHODS: We recruited 19 patients with CS-DAVF (n = 12) and TS-DAVF (n = 7) in this study. Blood hormone measurements were obtained from peripheral and jugular bulb samples during endovascular intervention. Hormone concentrations were analyzed using enzyme-linked immunosorbent assay kits, and statistical analyses were performed. RESULTS: Our study revealed a higher prevalence of CS-DAVF in females and TS-DAVF in males, which is consistent with previous studies. Estradiol concentration was significantly lower in the jugular bulb compared with in the periphery in both patients with CS- and TS-DAVF. This decrease in estradiol was observed irrespective of the patient's sex and independent of follicle-stimulating hormone levels. CONCLUSIONS: These findings indicate a local decrease in estradiol levels within the intracranial vasculature of patients with DAVF. This suggests a potential multifactorial role of estradiol in the pathomechanism of DAVFs, warranting further investigation to understand its influence on DAVF formation and potential targeted therapies, thereby enhancing patient outcomes.
Assuntos
Seio Cavernoso , Malformações Vasculares do Sistema Nervoso Central , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estradiol/sangue , Seios Transversos , AdultoRESUMO
OBJECTIVE: Transient neurological events (TNEs) are among the most important events after revascularization surgery in pediatric patients with moyamoya disease (MMD). Although hemodynamic changes and crying are representative factors of TNEs, brain compression by encephalomyosynangiosis (EMS) is another important cause of TNEs. Therefore, the authors assumed that making the EMS as thin as possible reduces the frequency of TNEs. However, thin-split EMS can lead to insufficient development of collateral vessels. This study aimed to evaluate the effects of thin-split EMS in combined revascularization surgery on postoperative outcomes in pediatric patients with MMD. METHODS: The authors retrospectively included 56 consecutive combined revascularization surgeries in the anterior cerebral circulation in pediatric patients with MMD. These surgeries were classified into the former group and thin-split EMS group. The temporal muscle was halved in the former EMS group and split as thinly as possible in the thin-split EMS group. The authors performed between-group comparisons of postoperative stroke events and TNEs during the acute period and the development of collateral flow and stroke events during the chronic period. RESULTS: Former and thin-split EMS procedures were performed in 37 and 19 patients, respectively. TNEs without crying or hemodynamic changes were observed significantly less frequently in the thin-split EMS group than in the former EMS group (0 [0.0%] in the thin-split EMS group vs 9 [24.3%] in the former EMS group, p = 0.021). There were no significant between-group differences in the development of indirect bypass during the chronic period (good: 34 [91.9%] and poor: 3 [8.1%] in the former EMS group vs good: 16 [84.2%] and poor: 3 [15.8%] in the thin-split EMS group; p = 0.397). Additionally, there were no significant between-group differences in the incidence of chronic clinical events, including death or stroke. CONCLUSIONS: Thin-split EMS can reduce TNEs that do not accompany crying or hemodynamic changes. Furthermore, the procedure has sufficient prevention effects against stroke events during the chronic postoperative period in pediatric patients with MMD.
Assuntos
Revascularização Cerebral , Doença de Moyamoya , Acidente Vascular Cerebral , Humanos , Criança , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/cirurgia , Doença de Moyamoya/complicações , Estudos Retrospectivos , Revascularização Cerebral/efeitos adversos , Revascularização Cerebral/métodos , Acidente Vascular Cerebral/etiologia , Complicações Pós-Operatórias/etiologiaRESUMO
We conducted a study to understand the characteristics of the finishing coils to select the appropriate coil for the final stage of embolization. Consequently, experimental embolization was performed on a 10 mm spherical silicone aneurysm filled with radiolucent coils, which simulated a volume embolization ratio of 20%. Nine different coils (i-ED complex ∞ SilkySoft, SilkySoft, ExtraSoft, V-Trak HyperSoft helical, Barricade 10 complex finishing, Optima complex 10 soft, Target 360 Ultra, Galaxy G3 mini, and Axium prime 3D ExtraSoft) were analyzed six times at random. After each coil insertion, indices that include area, Feret diameter, circularity, and centroid center of mass were calculated using biplane x-ray images. Furthermore, these data were analyzed using the spring constant k, which represents the stiffness of the coil. In multiple comparisons, a significant difference was observed in the area analysis. The i-ED complex ∞ SilkySoft was more widespread than Target 360 Ultra (p < 0.05). However, no significant differences were observed in the other indices. The spring constant k value of Target 360 Ultra was 2.5 times larger than that of the i-ED complex ∞ SilkySoft, and it negatively correlated with the area index rather than with the other indices. Notably, it was suggested that the smaller the spring constant k, the wider the distribution of the finishing coils. Although there was little difference between the coils, some coils had characteristics suggesting that good embolization could be expected using appropriate finishing coils.
Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Embolização Terapêutica/métodosRESUMO
Genetic factors alone cannot explain the pathophysiology of moyamoya disease (MMD), and environmental factors such as an immune response are thought to be involved. Oral and gut microbiomes have attracted attention as environmental factors in the pathophysiology of some vascular and autoimmune diseases. However, the relationship between MMD and these microbiomes is yet to be thoroughly investigated. This prospective case-control study aimed to compare the microbiomes of Japanese patients with MMD with those of healthy individuals to identify the specific bacteria involved in MMD. Saliva and fecal samples were collected from 16 patients with MMD who had not undergone revascularization surgery. Fifteen healthy individuals were matched for age, sex, and body mass index. The microbiomes were determined using 16S rRNA sequencing and analyzed using QIIME2. Differentially abundant microbes were identified using LEfSE and ANCOM-BC. In the oral microbiome, the two analytical methods showed that Campylobacter was more abundant in patients with MMD than in healthy individuals. Differences in the gut microbiome were smaller than those in the oral microbiome. In conclusion, the oral microbiome profiles of patients with MMD significantly differ from those of healthy individuals. Campylobacter spp. could be a substantial environmental factor in the pathophysiology of MMD.
Assuntos
Campylobacter , Microbiota , Doença de Moyamoya , Saliva , Humanos , Campylobacter/genética , Campylobacter/isolamento & purificação , Estudos de Casos e Controles , População do Leste Asiático , Doença de Moyamoya/genética , Doença de Moyamoya/microbiologia , RNA Ribossômico 16S/genética , Saliva/microbiologia , Fezes/microbiologiaRESUMO
PURPOSE: Artificial intelligence (AI)-based three-dimensional angiography (3D-A) was reported to demonstrate visualization of cerebral vasculature equivalent to that of three-dimensional digital subtraction angiography (3D-DSA). However, the applicability and efficacy of the AI-based 3DA algorithm have not yet been investigated for 3D-DSA micro imaging. In this study, we evaluated the usefulness of the AI-based 3DA in 3D-DSA micro imaging. MATERIALS AND METHODS: The 3D-DSA micro datasets of 20 consecutive patients with cerebral aneurysm (CA) were reconstructed with 3D-DSA and 3DA. Three reviewers compared 3D-DSA and 3DA in terms of qualitative parameters (degrees of visualization of CA and the anterior choroidal artery [AChA]) and quantitative parameters (aneurysm diameter, neck diameter, parent vessel diameter, and visible length of AChA). RESULTS: Qualitative evaluation of diagnostic potential revealed that visualization of CA and the proximal to middle parts of the AChA with 3DA was equal to that with conventional 3D-DSA; in contrast, visualization of the distal part of the AChA was lower with 3DA than with 3D-DSA. Further, regarding quantitative evaluation, the aneurysm diameter, neck diameter, and parent vessel diameter were comparable between 3DA and 3D-DSA; in contrast, the visible length of the AChA was lower with 3DA than with 3D-DSA. CONCLUSIONS: The AI-based 3DA technique is feasible and evaluable visualization of cerebral vasculature with respect to quantitative and qualitative parameters in 3D-DSA micro imaging. However, the 3DA technique offers lower visualization of such as the distal portion of the AChA than 3D-DSA.
Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Inteligência Artificial , Angiografia Digital/métodos , Imageamento Tridimensional/métodos , Artéria Carótida Interna , Angiografia Cerebral/métodosRESUMO
Intracranial aneurysms (IA) in infants are reportedly rare at 0.5% to 4.5% of all aneurysms. Furthermore, subarachnoid hemorrhage in infants younger than three months are even rarer as it has been reported in approximately 20 cases only till date. A 3-month-old infant with seizures and impaired consciousness was admitted to our hospital. Three-dimensional computed tomography angiography (3D-CTA) revealed a dissecting aneurysm with a maximum diameter of 13 mm in the right M2. Internal trapping using detachable coil were successfully performed, following which he was discharged without significant neurological deficit after one month of onset. Thus, we have reported a rare case of a large ruptured dissecting IA in a 3-month-old infant, in the right middle cerebral artery (MCA), successfully treated with an endovascular therapy, along with a literature review.
RESUMO
A 61-year-old man presented with massive epistaxis, amaurosis, nausea, and severe headache. A detailed examination revealed a subarachnoid hemorrhage and prolactinoma. Angiography showed a small internal carotid artery pseudoaneurysm and inadequate collateral circulation; thus, uncomplicated coil embolization was performed. Considering the side effects of medication, such as cerebrospinal fluid rhinorrhea, the patient was followed up for asymptomatic prolactinoma without medication after discharge. At 40 months later, aneurysm recurrence was confirmed. Flow diverter device placement was performed, and the outcomes were excellent. In the present report, we described a rare case of a ruptured internal carotid artery aneurysm in an untreated prolactinoma and discussed the literature.
RESUMO
BACKGROUND: Delayed paraplegia is a devastating complication of thoracoabdominal aortic surgery. Hydrogen sulfide (H2S) was reported to be protective in a mouse model of spinal cord ischemia and the beneficial effect of H2S has been attributed to polysulfides. The objective of this study was to investigate the effects of polysulfides on delayed paraplegia after spinal cord ischemia. METHODS AND RESULTS: Spinal cord ischemia was induced in male and female C57BL/6J mice by clamping the aortic arch and the left subclavian artery. Glutathione trisulfide (GSSSG), glutathione (GSH), glutathione disulfide (GSSG), or vehicle alone was administered intranasally at 0, 8, 23, and 32 h after surgery. All mice treated with vehicle alone developed paraplegia within 48 h after surgery. GSSSG, but not GSH or GSSG, prevented paraplegia in 8 of 11 male mice (73%) and 6 of 8 female mice (75%). Intranasal administration of 34S-labeled GSSSG rapidly increased 34S-labeled sulfane sulfur species in the lumbar spinal cord. In mice treated with intranasal GSSSG, there were increased sulfane sulfur levels, and decreased neurodegeneration, microglia activation, and caspase-3 activation in the lumbar spinal cord. In vitro studies using murine primary cortical neurons showed that GSSSG increased intracellular levels of sulfane sulfur. GSSSG, but not GSH or GSSG, dose-dependently improved cell viability after oxygen and glucose deprivation/reoxygenation (OGD/R). Pantethine trisulfide (PTN-SSS) also increased intracellular sulfane sulfur and improved cell viability after OGD/R. Intranasal administration of PTN-SSS, but not pantethine, prevented paraplegia in 6 of 9 male mice (66%). CONCLUSIONS: Intranasal administration of polysulfides rescued mice from delayed paraplegia after transient spinal cord ischemia. The neuroprotective effects of GSSSG were associated with increased levels of polysulfides and sulfane sulfur in the lumbar spinal cord. Targeted delivery of sulfane sulfur by polysulfides may prove to be a novel approach to the treatment of neurodegenerative diseases.
Assuntos
Isquemia do Cordão Espinal , Camundongos , Masculino , Feminino , Animais , Administração Intranasal , Dissulfeto de Glutationa , Camundongos Endogâmicos C57BL , Isquemia do Cordão Espinal/tratamento farmacológico , Isquemia do Cordão Espinal/complicações , Enxofre , Paraplegia/tratamento farmacológico , Paraplegia/etiologia , Paraplegia/prevenção & controleRESUMO
OBJECTIVE: To evaluate the static and dynamic features of blood blister-like aneurysms (BBAs) using cerebral angiography to identify characteristic features to improve the diagnosis of these uncommon aneurysms. METHODS: Digital subtraction angiography (DSA) images were compared between patients with BBAs (n = 12, group A) and patients with unruptured paraclinoid aneurysms ≤ 5 mm in size treated by endovascular procedures (n = 12, group B). DSA images were assessed for irregularities in the diameter of the parent artery and delayed inflow and outflow of contrast medium in the aneurysm. Enlargement of the aneurysm and morphological changes from the first assessment were also evaluated in patients with BBAs. RESULTS: Compared to the group B, group A had a higher proportion of irregular vessel diameter (p = 0.013) and the delayed contrast medium outflow (p = 0.014). As well, stagnation of contrast medium along the aneurysm wall was a characteristic finding of BBAs, even for small aneurysms. CONCLUSION: Irregular morphological features of the parent artery and delayed contrast medium outflow as characteristic findings of ruptured BBAs may improve the diagnosis of these uncommon aneurysms, which remains challenging in practice.
Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Humanos , Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Artérias , Angiografia Digital , Estudos Retrospectivos , Artéria Carótida InternaRESUMO
OBJECTIVE: The protocol for antiplatelet therapy after stent-assisted coil embolization (SACE) for intracranial aneurysms is not well established. In particular, the indications for single antiplatelet therapy (SAPT) discontinuation remain controversial. The authors investigated the long-term outcomes of SAPT discontinuation after SACE among patients at a single institution. METHODS: Patients who underwent SACE during the period from 2010 to 2020 and who were followed up for > 1 year were included in this study. The delayed ischemic and hemorrhagic complication rates were examined during follow-up. Moreover, the risk factors of antiplatelet therapy reduction or discontinuation and the outcomes of SAPT discontinuation were examined. RESULTS: In total, 240 patients were included in the analysis. The average patient age was 60.3 years, and the average follow-up period was 46.7 months. Nine (3.8%) patients presented with symptomatic delayed ischemic complication, and 3 (1.3%) patients experienced a decline in modified Rankin Scale score. The stent configuration (T- or Y-stent) was the only risk factor associated with delayed ischemic complication (p < 0.001). SAPT was discontinued in 147 (71.7%) of 205 patients who were followed up for > 2 years, and no ischemic complications were observed. CONCLUSIONS: It is safe to discontinue SAPT in patients without ischemic complications and with stable intraaneurysmal signals on MRA 2 years after SACE. The T- or Y-stent is a high-risk factor for delayed ischemic complications, and antiplatelet therapy reduction or discontinuation should be cautiously considered.
Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/efeitos adversos , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Embolização Terapêutica/métodos , Stents/efeitos adversos , Resultado do TratamentoRESUMO
This study sought to establish an experimental aneurysm model of visualizing coil insertion using radiolucent nylon coils. Moreover, this study aimed to clarify the characteristics and differences of each coil and use them clinically as indices of coil selection. The coil insertion test was performed on the 10 mm spherical silicone aneurysm model filled to a nylon coil volume embolization ratio of 11.8%. Five types of coil were randomly tested six times, and the distribution of the coils was analyzed by fluoroscopy imaging. Indices of "Area (mm2)," "Feret's diameter (mm)," and "Circularity" were calculated from the fluoroscopic images. Among the indices, only "Area" showed a significant difference between coils (p = 0.002). On multivariate analysis, "Area" of the ED Infini was larger than those of Target XL soft and Galaxy G3 (p = 0.018 and 0.026, respectively). Furthermore, the area of the 360 soft was larger than that of G3 (p = 0.049). Analysis of the correlation between these values and the coil configuration showed that "Area" was negatively correlated with the stock-wire diameter (r = -0.50; p = 0.004) and primary coil configuration (r = -0.65; p < 0.001). When inserting the coils in the early stage, although the difference between each coil is relatively difficult to obtain, knowledge on the proper use of the coils with differences in characteristics can help in selecting the coil most appropriate for the conditions.
Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/terapia , Nylons , Desenho de Equipamento , Prótese Vascular , Embolização Terapêutica/métodosRESUMO
Thromboembolic complications are a concern in the treatment of cerebral aneurysms using a flow diverter. In this study, we report a case of abnormal foreshortening of a Flow Re-Direction Endoluminal Device (FRED) caused by in-stent thrombosis immediately after its deployment. A 72-year-old woman had a large cavernous carotid aneurysm, which caused ptosis and diplopia. FRED deployment was planned, and dual antiplatelet therapy was initiated 2 weeks before the procedure. Under systemic heparinization, FRED was deployed with local compaction over the aneurysm orifice. Cone-beam computed tomography subsequently revealed slightly poor wall apposition at the proximal side. While the balloon catheter was prepared for angioplasty, the stent became abnormally foreshortened, the proximal side slipped into the aneurysm, and the internal carotid artery became occluded. FRED was removed using a snare wire, and recanalization was obtained. The lumen of the removed FRED was filled with thrombus. The antiplatelet therapy was changed to triple regimen, and a Pipeline Flex embolization device was placed 1 month later. At that time, no thromboembolic complications were noted. It was considered that thrombotic occlusion was followed by foreshortening of FRED on the distal side because of antegrade blood flow. Multiple factors, such as increased mesh density by locally compacted stent deployment, slightly poor wall apposition, clopidogrel resistance, and the dual-layer structure of FRED, may have been involved in thrombus formation.
Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano , Trombose , Feminino , Humanos , Idoso , Stents/efeitos adversos , Prótese Vascular , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Trombose/etiologia , Trombose/terapia , Resultado do TratamentoRESUMO
Electronic cigarettes (e-cigarettes) have been used widely as an alternative to conventional cigarettes and have become particularly popular among young adults. A growing body of evidence has shown that e-cigarettes are associated with acute lung injury and adverse effects in multiple other organs. Previous studies showed that high emissions of aldehydes (formaldehyde and acetaldehyde) in aerosols were associated with increased usage of the same e-cigarette coils. However, the impact on lung function of using aged coils has not been reported. We investigated the relationship between coil age and acute lung injury in mice exposed to experimental vaping for 1 h (2 puffs/min, 100 ml/puff). The e-liquid contains propylene glycol and vegetable glycerin (50:50, vol) only. The concentrations of formaldehyde and acetaldehyde in the vaping aerosols increased with age of the nichrome coils starting at 1200 puffs. Mice exposed to e-cigarette aerosols produced from 1800, but not 0 or 900, puff-aged coils caused acute lung injury, increased lung wet/dry weight ratio, and induced lung inflammation (IL-6, TNF-α, IL-1ß, MIP-2). Exposure to vaping aerosols from 1800 puff-aged coils decreased heart rate, respiratory rate, and oxygen saturation in mice compared to mice exposed to air or aerosols from new coils. In conclusion, we observed that the concentration of aldehydes (formaldehyde and acetaldehyde) increased with repeated and prolonged usage of e-cigarette coils. Exposure to high levels of aldehyde in vaping aerosol was associated with acute lung injury in mice. These findings show significant risk of lung injury associated with prolonged use of e-cigarette devices.
Assuntos
Lesão Pulmonar Aguda , Sistemas Eletrônicos de Liberação de Nicotina , Vaping , Animais , Camundongos , Acetaldeído , Lesão Pulmonar Aguda/induzido quimicamente , Aldeídos/toxicidade , Formaldeído/toxicidade , Glicerol , Interleucina-6 , Propilenoglicol/toxicidade , Aerossóis e Gotículas Respiratórios , Fator de Necrose Tumoral alfaRESUMO
In this article, we report a case wherein a brain tumor was suspected based on computed tomography and magnetic resonance imaging findings. We made an initial diagnosis of malignant brain tumor based on methionine-positron emission tomography (PET) findings, but the correct diagnosis was dural arteriovenous fistula (DAVF). The patient was a 45-year-old man with DAVF who developed headache. Methionine-PET imaging showed high methionine uptake in the lesion. Although the tumor was strongly suspected from the findings of methionine-PET, the diagnosis of DAVF could be made correctly only by interpreting digital subtraction angiography and computed tomographic angiography. The findings of methionine-PET, which is considered useful in the diagnosis and denial of brain tumors, made the diagnosis of DAVF more difficult. The increased uptake of methionine-PET in DAVF is an important finding because, to our knowledge, this study is the first to report such finding. The results of this study might be useful for differential diagnoses when the diagnosis is uncertain.
RESUMO
OBJECTIVES: Congenital afibrinogenemia is an autosomal recessive inherited disorder that can cause thrombotic as well as hemorrhagic events. We describe a case of repeated mild ischemic strokes due to a mural thrombus in the carotid artery and our medical treatment. CASE DESCRIPTION: A 49-year-old woman with congenital afibrinogenemia developed two minor ischemic strokes in two months. Clinical images revealed scattered fresh infarcts in the right middle cerebral artery region and mild cervical carotid artery stenosis. The risk for surgical treatment was considered to be extraordinarily high. The patient was treated with 100 mg/day of aspirin and 3 g fibrinogen infusion every two weeks. After the one-year course of medication, the mural thrombus gradually decreased, and there were no bleeding or ischemic stroke events. CONCLUSION: This case report highlights the successful treatment of an ischemic stroke in a patient with a congenital afibrinogenemia with an antiplatelet agent and fibrinogen replacement. There are no guidelines for managing ischemic stroke in patients with congenital afibrinogenemia, and further studies are needed.
Assuntos
Afibrinogenemia , Cardiopatias , AVC Isquêmico , Trombose , Afibrinogenemia/complicações , Afibrinogenemia/diagnóstico , Afibrinogenemia/tratamento farmacológico , Feminino , Fibrinogênio , Cardiopatias/tratamento farmacológico , Hemorragia , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/tratamento farmacológico , Pessoa de Meia-Idade , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologiaRESUMO
Objective: Owing to the limited time since the introduction of the PulseRider (PR), inconsequential or rare complications that clinicians should be aware of remain unreported yet. Here, we report a rare complication of incomplete detachment. Case Presentation: A 50-year-old male underwent PR-assisted coil embolization for a basilar tip aneurysm. Coiling was completed, and the detachment procedure was performed using a detachment machine; the success signal was observed. The delivery microcatheter was subsequently advanced back up to the proximal markers, and no reapproximation of the proximal markers, which indicates successful detachment, was observed. However, only one of the proximal markers returned to the microcatheter, and incomplete detachment of only one leg was detected. Ultimately, electrical detachment was not possible, and physical separation by tension was achieved. Conclusion: Our case report presents a rare case of a detachment problem in the PR. The PR could not be detached, although the signal revealed successful detachment. Therefore, careful withdrawal of the delivery wire by checking not only the proximal markers but also the behavior of the entire PR and coil complex is important.
RESUMO
BACKGROUND: We examined compliance differences among balloon remodeling microcatheters, which have not been established previously. METHODS: Straight and 120° angulated vascular models were created in a 3â mm diameter tube with 3â mm hole (vascular model A), a tube with a 4â mm hole (vascular model B), and a 4â mm diameter tube (vascular model C). We compared the pressure exerted when each balloon was herniated 1 or 2â mm between three compliant balloons (SHOURYU SR, TransForm C, and Scepter C) and four super-compliant balloons (HyperForm, SHOURYU HR, TransForm SC, and Scepter XC). RESULTS: In vascular model A, there was a significant difference in the pressure exerted by compliant balloons and super-compliant balloons in both the straight and angulated models. In the straight model (1 and 2â mm), the lowest pressure was exerted by HyperForm (super-compliant balloons group) and SHOURYU SR (compliant balloons group). The lowest pressure was exerted in the angulated model by HyperForm (super-compliant balloons group) and Scepter C (compliant balloons group). The Scepter balloon exerted higher pressure in the straight model than other balloon remodeling microcatheters but less in the angulated model. In vascular model B, the pressure decreased in all balloons compared with model A. In vascular model C, the pressure increased in all balloons compared with model A. CONCLUSIONS: Pressure differed across balloon remodeling microcatheters. In addition, vessel shape and diameter, and hole size, affected the results. Our findings can help select balloon remodeling microcatheters.