Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Circ Arrhythm Electrophysiol ; 16(5): e011740, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36960716

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infection has a high mortality. Previous investigations showed reduced postoperative infections using skin preparation with chlorhexidine, preoperative intravenous antibiotics, and a TYRX-a antibacterial envelope. The additional benefit of antibiotic pocket wash and postoperative antibiotics has not been systematically studied. METHODS: The ENVELOPE trial (A Randomized trial of Stand-Alone Use of the Antimicrobial Envelope in High-Risk Cardiac Device Patients) was a prospective, multicenter, randomized, controlled trial enrolling patients undergoing CIED procedures with ≥2 risk factors for infection. The control arm received standard chlorhexidine skin preparation, intravenous antibiotics, and the TYRX-a antibiotic envelope. The study arm received pocket wash (500 mL antibiotic solution) and postoperative antibiotics for 3 days along with the prophylactic control measures. The primary end point was CIED infection and system removal at 6 months. RESULTS: One thousand ten subjects (505 per arm) were enrolled and randomized. Patients were seen in person for a wound check with digital photo 2 weeks postimplant and at 3 and 6 months. CIED infection rate was low in both groups (1.0% control arm and 1.2% study arm, P=0.74). In the 11 subjects with infection and system removal, the time to study end point was 107±92 days with a PADIT (Prevention of Arrhythmia Device Infection Trial) score of 7.4 and a 64% 1-year mortality. Prior history of CIED infection independently predicted CIED system removal at 6 months in all subjects (odds ratio, 9.77, P=0.004). Of 11 infections requiring system removal, 5 were in the setting of pocket hematoma. CONCLUSIONS: The use of antibiotic pocket irrigation and postoperative oral antibiotics provides no additional benefit to the prophylactic measures of chlorhexidine skin preparation, preoperative intravenous antibiotics, and an antibiotic envelope in reducing CIED infection. Postoperative hematoma is a major risk factor for infection, driven by the use of antiplatelet and anticoagulant medications. The strongest predictor of CIED removal at 6 months, regardless of intervention, was prior CIED infection. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02809131.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Clorexidina , Antibacterianos/uso terapêutico , Cardiopatias/complicações , Hematoma/etiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
3.
J Arrhythm ; 38(1): 106-114, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35222756

RESUMO

BACKGROUND: Novel ablation catheters with mini electrode (ME) sensing have become available but their utility is unclear. We investigated whether ablation of the cavotricuspid isthmus (CTI) for atrial flutter (AFL) would be improved using ME signals. METHODS: Sixty-one patients (76% male, 63 ± 10 years) with CTI-dependent AFL underwent ablation using a maximum voltage-guided approach, randomized to either standard 8 mm non-irrigated catheter with bipolar signals or IntellaTip MiFi catheter using ME signals alone. RESULTS: Acute bidirectional block was achieved in 97%. Mean follow-up was 16.7 ± 10 months. The median number of ablation lesions was 13 in both groups (range 3-62 vs. 1-43, p = .85). No significant differences were observed in AFL recurrences (17% vs. 11%, p = .7), median procedure durations (97 min [interquartile range (IQR), 71-121] vs. 87 min [IQR, 72-107], p = .55) or fluoroscopy times (31 min [IQR, 21-52] vs. 38 min [IQR, 25-70], p = .56). Amplitudes of ME signals were on average 160% greater than blinded bipolar signals. In 23.7% of lesions where bipolar signals were difficult to interpret, 13.6% showed a clear ME signal. CONCLUSIONS: There was no difference in the effectiveness of CTI ablation guided by ME signals, compared with using bipolar signals from a standard 8 mm ablation catheter. While ME signal amplitudes were larger and sometimes present when the bipolar signal was unclear, this did not improve procedural characteristics or outcomes. The results suggest future research should focus on lesion integrity rather than signal sensing.

5.
Heart Lung Circ ; 29(6): e57-e68, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32451232

RESUMO

The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.


Assuntos
Betacoronavirus , Infecções por Coronavirus , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Pandemias , Pneumonia Viral , Austrália/epidemiologia , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/fisiopatologia , Infecções por Coronavirus/terapia , Humanos , Pneumonia Viral/epidemiologia , Pneumonia Viral/fisiopatologia , Pneumonia Viral/terapia , SARS-CoV-2
6.
J Electrocardiol ; 60: 118-125, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32361086

RESUMO

BACKGROUND: Implantable Cardiac Monitors (ICMs) are used for long-term monitoring of arrhythmias. BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector due to a flexible antenna, simplified implantation with a dedicated insertion tool for pocket formation and ICM placement in a single step, and daily automatic Home Monitoring (HM) function. METHODS: In 47 patients undergoing BIOMONITOR III insertion for any ICM indication, 16 investigators at 10 Australian sites assessed handling characteristics of the insertion tool, R-wave amplitudes, noise burden, P-wave visibility, and HM transmission success. Patients were followed for 1 month. RESULTS: All 47 attempted insertions were successful. Median time from skin incision to removal of the insertion tool after ICM insertion was 39 s (IQR 19-65) and to wound closure and cleaning was 4.7 min (IQR 3.5-7.8). All aspects of the insertion tool were rated as "good" or "excellent" in ≥97.9% and "fair" in ≤2.1% of patients, except for "force needed for tunnelling" (91.5% good/excellent, 8.5% fair). Based on HM data, R-waves in the first month were stable at 0.70 ± 0.37 mV. Median noise burden (disabling automatic rhythm evaluation) was 0.19% (IQR 0.00-0.93), equivalent to 2.7 min (IQR 0.0-13.4) per day. In HM-transmitted ECG strips with regular sinus rhythm, P-waves were visible in 89 ± 24% of heart cycles. Patient-individual automatic Home Monitoring transmission success was 98.0% ± 5.5%. CONCLUSIONS: The novel ICM performed well in all aspects studied, including fast insertion, reliable R-wave sensing, good P-wave visibility, and highly successful HM transmissions.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Arritmias Cardíacas/diagnóstico , Austrália , Humanos
8.
Heart Lung Circ ; 27(8): 989-994, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28966115

RESUMO

BACKGROUND: Anticoagulation prior to elective external direct current cardioversion (EDCCV) is mandatory. The inability to monitor compliance with novel oral anticoagulants (NOACs) raises a potential safety issue. We aimed to evaluate whether a structured, nurse-led assessment of compliance prior to EDCCV ensures safety without the need for routine transoesophageal echocardiography (TOE). METHODS: Data was prospectively collected on consecutive patients undergoing EDCCV during 2014-2015. All procedures were supervised by an electrophysiology clinical nurse consultant (EPCNC). Drug compliance was verbally assessed using a standardised questionnaire by the EPCNC. Novel oral anticoagulants compliance was required for a continuous period of 3 weeks prior to EDCCV; otherwise a TOE-guided EDDCV was performed. All patients had follow-up 30 days post-procedure. RESULTS: Three hundred and eleven cardioversions were performed on 256 patients in whom 154 (49.5%) were prescribed a NOAC (rivaroxaban (n=105; 68.2%), dabigatran (n=38; 24.7%), apixaban (n=11; 7.1%)). Median age was 63 years (24-94 yrs), mean CHADS2-Vasc score was 2.0±1.5 and 138 (89.6%) were outpatients. One hundred and twenty-nine (83.8%) EDCCV were for atrial fibrillation and 25 (16.2%) for atrial flutter. Sinus rhythm was achieved in 90.3% of cases. Fourteen patients (9%) assessed as non-compliant underwent TOE. 129 (83.8%) EDCCV were performed without prior TOE. No stroke or systemic embolism was identified in any patient treated with either warfarin or a NOAC. CONCLUSIONS: A standardised, verbal questionnaire can be administered to detect NOAC non-compliance in patients undergoing EDCCV. With appropriate compliance assessment a nurse-led EDCCV without routine TOE did not significantly compromise safety in this study group.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Cardioversão Elétrica/métodos , Cooperação do Paciente , Inquéritos e Questionários , Tromboembolia/prevenção & controle , Administração Oral , Idoso , Fibrilação Atrial/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tromboembolia/diagnóstico , Tromboembolia/etiologia
9.
Pacing Clin Electrophysiol ; 40(5): 537-544, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28244206

RESUMO

BACKGROUND: Controversy exists regarding the optimal lead position for chronic right ventricular (RV) pacing. Placing a lead at the RV septum relies upon fluoroscopy assisted by a surface 12-lead electrocardiogram (ECG). We compared the postimplant lead position determined by ECG-gated multidetector contrast-enhanced computed tomography (MDCT) with the position derived from the surface 12-lead ECG. METHODS: Eighteen patients with permanent RV leads were prospectively enrolled. Leads were placed in the RV septum (RVS) in 10 and the RV apex (RVA) in eight using fluoroscopy with anteroposterior and left anterior oblique 30° views. All patients underwent MDCT imaging and paced ECG analysis. ECG criteria were: QRS duration; QRS axis; positive or negative net QRS amplitude in leads I, aVL, V1, and V6; presence of notching in the inferior leads; and transition point in precordial leads at or after V4. RESULTS: Of the 10 leads implanted in the RVS, computed tomography (CT) imaging revealed seven to be at the anterior RV wall, two at the anteroseptal junction, and one in the true septum. For the eight RVA leads, four were anterior, two septal, and two anteroseptal. All leads implanted in the RVS met at least one ECG criteria (median 3, range 1-6). However, no criteria were specific for septal position as judged by MDCT. Mean QRS duration was 160 ± 24 ms in the RVS group compared with 168 ± 14 ms for RVA pacing (P = 0.38). CONCLUSIONS: We conclude that the surface ECG is not sufficiently accurate to determine RV septal lead tip position compared to cardiac CT.


Assuntos
Fibrilação Atrial/cirurgia , Terapia de Ressincronização Cardíaca/métodos , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Cirurgia Assistida por Computador/métodos , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Técnicas de Imagem Cardíaca/métodos , Feminino , Fluoroscopia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Pacing Clin Electrophysiol ; 40(9): 1039-1041, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28240372

RESUMO

Chronic right ventricular (RV) apical pacing may lead to the development of heart failure in some patients. Although pacing of the RV septum has been proposed as an alternative, positioning a lead in the true septum has proven challenging. In addition to fluoroscopy at implant, it has been suggested that 12-lead surface electrocardiogram (ECG) can be used to determine septal lead position; however, studies show this may be inaccurate. We present a case where a change in the ECG QRS axis late after pacemaker insertion with an active fixation lead highlights the difficulties of ECG localization of pacing leads.


Assuntos
Eletrocardiografia , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/métodos
11.
Int J Gynecol Pathol ; 36(1): 90-94, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27362904

RESUMO

Minimal-deviation endometrioid adenocarcinoma (MDEA) of the uterine cervix is a rare tumor that may be confused histologically with a number of benign lesions as well as other types of endocervical neoplasia. The histologic and immunohistochemical features of MDEA have been described in case reports and in small series, but correlation of these findings with ultrastructural examination has not been documented. Herein we report a 51-yr-old patient who underwent hysterectomy for menorrhagia and was found to have a clinically unsuspected, stage IB cervical MDEA. The light microscopic, immunohistochemical, and electron microscopic features of the tumor are described, with the most significant ultrastructural abnormality being the presence of abnormal cilia and ciliogenesis.


Assuntos
Adenocarcinoma/diagnóstico , Carcinoma Endometrioide/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Adenocarcinoma/patologia , Adenocarcinoma/ultraestrutura , Carcinoma Endometrioide/patologia , Carcinoma Endometrioide/ultraestrutura , Colo do Útero/patologia , Colo do Útero/ultraestrutura , Diagnóstico Diferencial , Feminino , Humanos , Histerectomia , Pessoa de Meia-Idade , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/ultraestrutura
12.
J Cardiovasc Electrophysiol ; 27(12): 1429-1436, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27569722

RESUMO

INTRODUCTION: This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort. METHODS AND RESULTS: Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g. The Control cohort underwent traditionally guided CTI ablation. Traditional parameters (electrogram and impedance change) were assessed in both cohorts. All ablations regardless of achieving targets were included in data analysis. Bidirectional CTI block was achieved in all of the Study and 27 of the Control cohort. Atrial flutter recurred in 3 (10%) patients (follow-up 564 ± 212 days) in the study cohort and in 3 (10%) patients (follow-up 804 ± 540 days) in the Control cohort. There were no major complications in either cohort. Traditional parameters correlated poorly with CF parameters. In the Study cohort, flutter recurrence was associated with significantly lower FTI and ablation duration, but was not associated with total average CF. CONCLUSION: CTI ablation can be safely performed using CF parameters guiding ablation, with similar long-term results to a historical ablation control group. Potentially CF parameters may provide adjunctive information to enable a more efficient CTI ablation. Further research is required to confirm this.


Assuntos
Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Transdutores de Pressão , Valva Tricúspide/cirurgia , Potenciais de Ação , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Eletrocardiografia , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/fisiopatologia
13.
Heart Lung Circ ; 25(10): e130-2, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27267481

RESUMO

Coronary vasospasm is an uncommon, but perhaps under-recognised, cause of cardiac arrest. We present a novel case of an exercise-induced out-of-hospital cardiac arrest due to coronary vasospasm, captured on a heartrate monitor, and discuss the management options for this condition.


Assuntos
Vasoespasmo Coronário , Parada Cardíaca Extra-Hospitalar , Vasoespasmo Coronário/complicações , Vasoespasmo Coronário/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/etiologia , Parada Cardíaca Extra-Hospitalar/fisiopatologia
14.
Heart Lung Circ ; 25(8): 814-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27320854

RESUMO

Cardiac implantable electronic devices (pacemakers and defibrillators) are increasingly common in modern cardiology practice, and health professionals from a variety of specialties will encounter patients with such devices on a frequent basis. This article will focus on the subset of patients who may request, or be appropriate for, device deactivation and discuss the issues surrounding end-of-life decisions, along with the ethical and legal implications of device deactivation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Assistência Terminal/métodos , Austrália , Humanos , Assistência Terminal/legislação & jurisprudência
15.
Pacing Clin Electrophysiol ; 39(4): 382-92, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26769293

RESUMO

BACKGROUND: Right ventricular nonapical (RVNA) pacing may reduce the risk of heart failure. Fluoroscopy is the standard approach to determine lead tip position, but is inaccurate. We compared cardiac computed tomography (CT), magnetic resonance imaging (MRI), two-dimensional and three-dimensional transthoracic echocardiography (TTE), and chest x-ray (CXR) to assess which provides the optimal assessment of right ventricular (RV) lead tip position. METHODS: Eighteen patients with MRI-conditional pacemakers (10 RVNA and eight apical [RVA] leads) underwent contrast CT, MRI, TTE, and a standard postimplant posteroanterior and lateral CXR. To compare images, the RV was arbitrarily partitioned into three long-axis segments (right ventricular outflow tract, middle, and apex), and two short-axis segments (septal and nonseptal). Agreement between modalities was assessed. RESULTS: RV lead tip position was identified in all patients on CT, TTE, and CXR, but was not identified in seven (39%) patients on MRI due to device-related artifact. Of 10 leads deemed to be nonapical/septal during implant, 70% were identified as nonapical on CXR, 60% on CT, 60% on MRI, and 80% on TTE. On CT imaging only 10% were truly septal, 20% on MRI, 30% on CXR, and 80% on TTE. Agreement was better between modalities when assessing position of the designated RVA leads. CONCLUSION: During implant leads intended for the septum are not confirmed as such on subsequent imaging, and marked heterogeneity is apparent between modalities. MRI is limited by artifact, and discrepancy exists between TTE and CT in identifying septal lead position. CT gave the clearest definition of lead tip position.


Assuntos
Eletrodos Implantados , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Marca-Passo Artificial , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Ecocardiografia/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Tomografia Computadorizada por Raios X/métodos
16.
Heart Rhythm ; 13(2): 331-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26484789

RESUMO

BACKGROUND: Advanced atrial remodeling predicts poor clinical outcomes in human atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to define the magnitude and predictors of change in left atrial (LA) structural remodeling over 12 months of AF. METHODS: Thirty-eight patients with paroxysmal AF managed medically (group 1), 20 undergoing AF ablation (group 2), and 25 control patients with no AF history (group 3) prospectively underwent echocardiographic assessment of strain variables of LA reservoir function at baseline and at 4, 8, and 12 months. In addition, P-wave duration (Pmax,, Pmean) and dispersion (Pdis) were measured. AF burden was quantified by implanted recorders. Twenty patients undergoing ablation underwent electroanatomic mapping (mean 333 ± 40 points) for correlation with LA strain. RESULT: Group 1 demonstrated significant deterioration in total LA strain (26.3% ± 1.2% to 21.7% ± 1.2%, P < .05) and increases in Pmax (132 ± 3 ms to 138 ± 3 ms, P < .05) and Pdis (37 ± 2 ms to 42 ± 2 ms, P < .05). AF burden ≥10% was specifically associated with decline in strain and with P-wave prolongation. Conversely, group 2 manifest improvement in total LA strain (21.3% ± 1.7% to 28.6% ± 1.7%, P <.05) and reductions in Pmax (136 ± 4 ms to 119 ± 4 ms, P < .05) and Pdis (47 ± 3 ms to 32 ± 3 ms, P < .05). Change was not significant in group 3. LA mean voltage (r = 0.71, P = .0005), percent low voltage electrograms (r = -0.59, P = .006), percent complex electrograms (r = -0.68, P = .0009), and LA activation time (r = -0.69, P = .001) correlated with total strain as a measure of LA reservoir function. CONCLUSION: High-burden AF is associated with progressive LA structural remodeling. In contrast, AF ablation results in significant reverse remodeling. These data may have implications for timing of ablative intervention.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial , Função do Átrio Esquerdo/fisiologia , Remodelamento Atrial/fisiologia , Ablação por Cateter/métodos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estudos de Coortes , Progressão da Doença , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tempo para o Tratamento , Resultado do Tratamento , Vetorcardiografia/métodos
17.
Heart Lung Circ ; 25(2): 140-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26377167

RESUMO

BACKGROUND: Acute cardiac response to right ventricular pacing is unknown. We aimed to assess the acute haemodynamic, biochemical and hormonal response to asynchronous right ventricular pacing and investigate whether there is a difference between an apical and outflow tract site. METHODS: In 21 patients with normal cardiac function, haemodynamics, brain natriuretic peptide and high sensitive troponin T were measured in response to 10minutes of pacing at each site in a randomised crossover fashion and compared. RESULTS: Pacing both sites there were significant increases in pulmonary capillary wedge pressures (p<0.001) and QRS width (p< 0.01). In comparison to baseline, apical pacing demonstrated significant (p<0.05) increases in arterial peptide and troponin levels and venous peptide levels. Outflow tract pacing compared to baseline demonstrated significant (p<0.05) increases in arterial peptide and venous, arterial and coronary sinus troponin. There were no significant differences in responses between sites. CONCLUSION: Asynchronous right ventricular pacing demonstrated significant increases in filling pressures, cardiac hormonal and biochemical response above baseline with very short durations of pacing (10minutes). There was no difference in response between sites. These findings imply that even very short periods of right ventricular based pacing are potentially deleterious.


Assuntos
Estimulação Cardíaca Artificial/métodos , Hemodinâmica , Peptídeo Natriurético Encefálico/sangue , Troponina T/sangue , Adulto , Idoso , Humanos , Pessoa de Meia-Idade
18.
Soc Work ; 60(3): 248-55, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26173366

RESUMO

This study assessed how a social work-led care coordination intervention would reduce the within-30-day hospital readmission rate among moderate- and high-risk patients age 50 years or older. Authors ran a randomized controlled trial to determine whether there was a significant difference in within-30-day readmission rates between patients receiving usual care post-discharge and those receiving intervention from an MSW intern (one home visit and one to two phone calls). Results were obtained using a sample of hospitalized patients with a LACE index score of 7 or higher (N = 89). Analysis suggests that the intervention improved the likelihood of not being readmitted by some 22 percent (RR = 1.222; 95% CI = 1.063-1.405). The risk improvement with the intervention was highly statistically significant (p = .003). This study shows that a time-efficient care coordination intervention by MSW interns may decrease hospital readmission rates. Replications of this study in other communities, with more diverse populations, and with larger numbers of patients will indicate whether results are generalizable.


Assuntos
Continuidade da Assistência ao Paciente , Readmissão do Paciente/estatística & dados numéricos , Serviço Social , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , New York
19.
Indian Pacing Electrophysiol J ; 15(4): 216-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26937124

RESUMO

The DF-4 is a new defibrillator lead technology. We present two cases of non-physiological transient ventricular over-sensing in patients who underwent implantation of an ICD for secondary prevention. Case 1 had ventricular over-sensing during pacing threshold evaluation post defibrillation testing while Case 2 had the lead integrity alert triggered immediately post discharge with transient over-sensing. No lead-connector issues were found. Case 1 was likely due to improper venting of the header and trapped air. Case 2 was hypothesized to be due to intermittent header pin non-contact secondary to blood in the header. These cases reveal that DF-4 leads are subject to both reported and potentially novel causes of transient acute ventricular over-sensing.

20.
J Interprof Care ; 29(4): 372-3, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25268507

RESUMO

Interprofessional collaborative practice is increasingly recognized as an essential model in health care. This study lends preliminary support to the notion that medical students (including residents) and social work students develop a broader understanding of one another's roles and contributions to enhancing community-dwelling geriatric patients' health, and develop a more thorough understanding of the inherent complexities and unique aspects of geriatric health care. Wilcoxon Signed Rank Tests of participants' scores on the Index of Interdisciplinary Collaboration (IIC) indicated the training made significant changes to the students' perception of interprofessional collaboration. Qualitative analysis of participants' statements illustrated (1) benefits of the IPE experience, including complementary roles in holistic interventions; and (2) challenges to collaboration. The findings suggest that interprofessional educational experiences have a positive impact upon students' learning and strategies for enhanced care of geriatric patients.


Assuntos
Comportamento Cooperativo , Geriatria/educação , Pessoal de Saúde/educação , Relações Interprofissionais , Serviço Social/educação , Currículo , Humanos , Equipe de Assistência ao Paciente , Aprendizagem Baseada em Problemas , Assistentes Sociais/psicologia , Estudantes de Medicina/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA