Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Br J Biomed Sci ; 70(4): 149-55, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24400426

RESUMO

Several studies have reported poor results when trying to identify microorganisms directly from the bioMérieux BacT/ALERT blood culture system using matrix-assisted laser desorption/ionisation-time of flight (MALDI-TOF) mass spectrometry. The aim of this study is to evaluate two new methods, Sepsityper and an enrichment method for direct identification of microorganisms from this system. For both methods the samples were processed using the Bruker Microflex LT mass spectrometer (Biotyper) using the Microflex Control software to obtain spectra. The results from direct analysis were compared with those obtained by subculture and subsequent identification. A total of 350 positive blood cultures were processed simultaneously by the two methods. Fifty-three cultures were polymocrobial or failed to grow any organism on subculture, and these results were not included as there was either no subculture result, or for polymicrobial cultures it was known that the Biotyper would not be able to distinguish the constituent organisms correctly. Overall, the results showed that, contrary to previous reports, it is possible to identify bacteria directly from bioMérieux blood culture bottles, as 219/297 (74%) correct identifications were obtained using the Bruker Sepsityper method and 228/297 (77%) were obtained for the enrichment method when there is only one organism was present. Although the enrichment method was simpler, the reagent costs for the Sepsityper method were approximately pound 4.00 per sample compared to pound 0.50. An even simpler and cheaper method, which was less labour-intensive and did not require further reagents, was investigated. Seventy-seven specimens from positive signalled blood cultures were analysed by inoculating prewarmed blood agar plates and analysing any growth after 1-, 2- and 4-h periods of incubation at 37 degrees C, by either direct transfer or alcohol extraction. This method gave the highest number of correct identifications, 66/77 (86%), and was cheaper and less labour-intensive than either of the two above methods.


Assuntos
Bactérias/isolamento & purificação , Técnicas de Tipagem Bacteriana/instrumentação , Técnicas de Tipagem Bacteriana/métodos , Sangue/microbiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Bactérias/classificação , Meios de Cultura , Humanos , Reprodutibilidade dos Testes , Software , Staphylococcus/classificação , Staphylococcus/isolamento & purificação , Fatores de Tempo
2.
Science ; 203(4382): 748-50, 1979 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-17832983

RESUMO

The Pioneer Venus electric field detector observes significant effects of the interaction of the solar wind with the ionosphere of Venus all along the orbiter trajectory. Information is obtained on plasma oscillations emitted by suprathermal electrons beyond the bows shock, on sharp and diffuse shock structures, and on waveparticle interaction phenomena that are important near the boundary of the dayside ionosphere.

3.
Science ; 162(3856): 898-901, 1968 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-17769077

RESUMO

Coordinated observations of the earth's bow shock were made as Vela 3A and Explorer 33 passed within 6 earth radii of each other. Elapsed time measurements of shock motion give directly determined velocities in the range 1 to 10 kilometers per second and establish the existence of two regions, one of large amplitude magnetic "shock" oscillations and another of smaller, sunward, upstream oscillations. Each region is as thick as 1 earth radius, or more.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA