Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
3.
Circ Arrhythm Electrophysiol ; 16(5): e011740, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36960716

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infection has a high mortality. Previous investigations showed reduced postoperative infections using skin preparation with chlorhexidine, preoperative intravenous antibiotics, and a TYRX-a antibacterial envelope. The additional benefit of antibiotic pocket wash and postoperative antibiotics has not been systematically studied. METHODS: The ENVELOPE trial (A Randomized trial of Stand-Alone Use of the Antimicrobial Envelope in High-Risk Cardiac Device Patients) was a prospective, multicenter, randomized, controlled trial enrolling patients undergoing CIED procedures with ≥2 risk factors for infection. The control arm received standard chlorhexidine skin preparation, intravenous antibiotics, and the TYRX-a antibiotic envelope. The study arm received pocket wash (500 mL antibiotic solution) and postoperative antibiotics for 3 days along with the prophylactic control measures. The primary end point was CIED infection and system removal at 6 months. RESULTS: One thousand ten subjects (505 per arm) were enrolled and randomized. Patients were seen in person for a wound check with digital photo 2 weeks postimplant and at 3 and 6 months. CIED infection rate was low in both groups (1.0% control arm and 1.2% study arm, P=0.74). In the 11 subjects with infection and system removal, the time to study end point was 107±92 days with a PADIT (Prevention of Arrhythmia Device Infection Trial) score of 7.4 and a 64% 1-year mortality. Prior history of CIED infection independently predicted CIED system removal at 6 months in all subjects (odds ratio, 9.77, P=0.004). Of 11 infections requiring system removal, 5 were in the setting of pocket hematoma. CONCLUSIONS: The use of antibiotic pocket irrigation and postoperative oral antibiotics provides no additional benefit to the prophylactic measures of chlorhexidine skin preparation, preoperative intravenous antibiotics, and an antibiotic envelope in reducing CIED infection. Postoperative hematoma is a major risk factor for infection, driven by the use of antiplatelet and anticoagulant medications. The strongest predictor of CIED removal at 6 months, regardless of intervention, was prior CIED infection. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02809131.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Clorexidina , Antibacterianos/uso terapêutico , Cardiopatias/complicações , Hematoma/etiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Marca-Passo Artificial/efeitos adversos
4.
Heart Rhythm ; 20(5): 737-743, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36693614

RESUMO

BACKGROUND: The TYRX (Medtronic) absorbable antibacterial envelope has been shown to stabilize implantable cardiac devices and reduce infection. A third-generation envelope was developed to reduce surface roughness with a redesigned multifilament mesh and enhanced form factor but identical polymer coating and antibiotic concentrations as the currently available second-generation envelope. OBJECTIVE: The purpose of this study was to compare drug elution, bacterial challenge efficacy, stabilization, and absorption of second- vs third-generation envelopes. METHODS: Antibiotic elution was assessed in vitro and in vivo. For efficacy against gram-positive/gram-negative bacteria, 40 rabbits underwent device insertions with or without third-generation envelopes. For stabilization (migration, rotation), 5 sheep were implanted with 6 devices each in second- or third-generation envelopes. Prespecified acceptance criteria were <83-mm migration and <90° rotation. Absorption was assessed via gross pathology. RESULTS: Elution curves were equivalent (similarity factors ≥50 per Food and Drug Administration guidance). Third-generation envelopes eluted antibiotics above minimal inhibitory concentration (MIC) in vivo at 2 hours postimplant through 7 days, consistent with second-generation envelopes. Bacterial challenge showed reductions (P <.05) in infection with second- and third-generation envelopes. Device migration was 5.5 ± 3.5 mm (third-generation) vs 9. 9 ±7.9 mm (second-generation) (P <.05). Device rotation was 18.9° ± 11.4° (third-generation) vs 17.6° ± 15.1° (second-generation) and did not differ (P = .79). Gross pathology confirmed the absence of luminal mesh remainders and no differences in peridevice fibrosis at 9 or 12 weeks. CONCLUSION: The third-generation TYRX absorbable antibacterial envelope demonstrated equivalent preclinical performance to the second-generation envelope. Antibiotic elution curves were similar, elution was above MIC for 7 days, infections were reduced compared to no envelope, and acceptance criteria for migration, rotation, and absorption were met.


Assuntos
Desfibriladores Implantáveis , Coelhos , Animais , Ovinos , Antibacterianos/farmacologia
5.
Heart Rhythm ; 20(1): 46-54, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36075532

RESUMO

BACKGROUND: Previous studies demonstrated that accelerometer-based, mechanically timed atrioventricular synchrony (AVS) is feasible using a leadless ventricular pacemaker. OBJECTIVE: The purpose of this study was to determine the performance of a leadless ventricular pacemaker with accelerometer-based algorithms that provide AVS pacing. METHODS: AccelAV was a prospective, single-arm study to characterize AVS in patients implanted with a Micra AV, which uses the device accelerometer to mechanically detect atrial contractions and promote VDD pacing. The primary objective was to characterize resting AVS at 1 month in patients with complete atrioventricular block (AVB) and normal sinus function. RESULTS: A total of 152 patients (age 77 ± 11 years; 48% female) from 20 centers were enrolled and implanted with a leadless pacemaker. Among patients with normal sinus function and complete AVB (n = 54), mean resting AVS was 85.4% at 1 month, and ambulatory AVS was 74.8%. In the subset of patients (n = 20) with programming optimization, mean ambulatory AVS was 82.6%, representing a 10.5% improvement (P <.001). Quality of life as measured by the EQ-5D-3L (EuroQol Five-Dimensions Three-Level questionnaire) improved significantly from preimplant to 3 months (P = .031). In 37 patients with AVB at both 1 and 3 months, mean AVS during rest did not differ (86.1% vs 84.1%; P = .43). There were no upgrades to dual-chamber devices or cardiac resynchronization therapy through 3 months. CONCLUSION: Accelerometer-based mechanical atrial sensing provided by a leadless pacemaker implanted in the right ventricle significantly improves quality of life in a select cohort of patients with AV block and normal sinus function. AVS remained stable through 3 months, and there were no system upgrades to dual-chamber pacemakers.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/terapia , Estudos Prospectivos , Qualidade de Vida , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/métodos
6.
Heart Rhythm ; 19(3): 363-371, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34767985

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead monitoring diagnostic alerts facilitate the diagnosis of structural lead failure. OBJECTIVE: The purpose of this study was to prospectively study the performance of Medtronic ICD lead monitoring alerts. METHODS: A prespecified ancillary substudy, World-Wide Randomized Antibiotic Envelope Infection Prevention Trial, was conducted in patients with an ICD with all available alerts enabled. The investigators reported possible lead system events (LSEs), with or without an alert. An independent committee reviewed all data and classified events as lead failure, other LSE, or nonlead system events (NLEs). RESULTS: In 4942 patients who were followed for 19.4 ± 8.7 months, there were 124 alerts (65 LSEs, 59 NLEs) and 19 LSEs without an alert. Lead monitoring alerts had 100% sensitivity for the 48 adjudicated lead failures (95% confidence interval 92.6%-100%) and for 10 events adjudicated as either lead failure or connection issue. The positive predictive value of alerts for lead failure was 38.7% (48 of 124). For 34 pace-sense lead failures, an alert that incorporated oversensing was more sensitive than the pacing impedance threshold alert (33 patients [97.1%] vs 9 patients [26.5%]; P < .0001). However, the sensitivity was only 13.6% for lead dislodgments or perforations. Inappropriate shocks occurred in 2 patients with pace-sense lead failure (5.9%). No patient had unnecessary lead replacement for any of the NLEs. CONCLUSION: In this first real-world prospective study, lead monitoring alerts had 100% sensitivity for identifying lead failures. Although their positive predictive value was modest, no false-positive alerts resulted in an unnecessary lead replacement. For the diagnosis of pace-sense lead failure, an alert for oversensing was more sensitive than a pacing impedance threshold alert. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02277990.


Assuntos
Desfibriladores Implantáveis , Desfibriladores Implantáveis/efeitos adversos , Impedância Elétrica , Falha de Equipamento , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos
9.
Europace ; 23(9): 1446-1455, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33755136

RESUMO

AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Adolescente , Adulto , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Atenção à Saúde , Eletrônica , Humanos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Fatores de Risco
10.
Pacing Clin Electrophysiol ; 44(6): 1130-1132, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33590525

RESUMO

Manufacturers of cardiac implantable electronic devices have incorporated automatic features to allow for remote monitoring, improve device longevity, and additional safety. Algorithms to automatically measure capture threshold and adjust output to preserve battery life are one such feature. Automatic features may occasionally result in unexpected or undesirable clinical outcomes. We report on a patient who developed ventricular tachycardia inadvertently induced by the AutoCapture. feature of an Abbott/St. Jude Medical (SJM) pacemaker.


Assuntos
Marca-Passo Artificial/efeitos adversos , Taquicardia Ventricular/etiologia , Idoso , Algoritmos , Humanos , Masculino
11.
JACC Clin Electrophysiol ; 7(1): 50-61, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33478712

RESUMO

OBJECTIVES: This study characterized the microbiology of major cardiac implantable electronic device (CIED) infections that occurred during the WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) study. BACKGROUND: The WRAP-IT study offers a unique opportunity for further understanding of the pathogens involved in major CIED infections in a prospective dataset, with implications for clinical practice and infection management. METHODS: A total of 6,800 patients randomized 1:1 to receive an antibacterial envelope or not (control subjects) were included in this analysis. Patient characteristics, infection manifestation (pocket vs. systemic), and infection microbiology were evaluated through all follow-up (36 months). Data were analyzed using Cox proportional hazards regression. RESULTS: A total of 3,371 patients received an envelope, and 3,429 patients were control subjects. Major CIED infection occurred in 32 patients who received an envelope and 51 control subjects (36-month Kaplan-Meier estimated event rate, 1.3% and 1.9%, respectively; p = 0.046). A 61% reduction in major pocket infection was observed within 12 months of the procedure in the envelope group (hazard ratio: 0.39, 95% confidence interval: 0.21 to 0.73; p = 0.003). Among 76 patients with major infections who had a sample taken, causative pathogens were identified in 47 patients. Staphylococcus species were the predominate pathogen (n = 31) and envelope use resulted in a 76% reduction in Staphylococcus-related pocket infections (n = 4 vs. 17; p = 0.010). Envelope use was not associated with delayed onset of pocket infections and did not affect the presentation of infections. CONCLUSIONS: Antibacterial envelope use resulted in a significant reduction of major CIED pocket infections and was particularly effective against Staphylococcus species, the predominant cause of pocket infections. (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial [WRAP-IT]; NCT02277990).


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Antibacterianos/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle
12.
Pacing Clin Electrophysiol ; 43(9): 992-999, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32567072

RESUMO

OBJECTIVE: This study evaluated the risk of subclinical atrial fibrillation (AF) in patients with central retinal artery occlusion (CRAO) compared to those with cryptogenic stroke using implantable loop recorders (ILR). METHODS: We conducted a retrospective analysis of 273 consecutive patients who had ILRs inserted at our institution for either cryptogenic stroke (n = 227) or CRAO (n = 46). Our primary endpoint was a time to event analysis for the new diagnosis of AF by ILR. Univariable and multivariable Cox proportional hazard models were used to determine the predictors of time-to-AF. RESULTS: A total of 64 patients were found to have newly diagnosed AF by remote monitoring of the ILR. AF was detected in 57 of 227 (25%) cryptogenic stroke patients by the end of a maximum 5.1 years follow-up and in seven of 46 (15%) CRAO patients by the end of a maximum 3.6 years follow-up (P = .215, log-rank test). The Kaplan-Meier estimates for freedom from AF was 59.4% for CRAO and 66.6% for cryptogenic stroke (P = NS, log-rank test). Baseline variables predicting AF included older patients, higher CHADS2 VASC score, longer PR interval on initial EKG evaluation, and mitral annular calcification on transthoracic echocardiogram. CONCLUSIONS: Patients with CRAO are at risk for subclinical AF, similar to those with cryptogenic stroke. Long-term monitoring to detect AF may lead to changes in pharmacotherapy to reduce the risk for subsequent stroke.


Assuntos
Fibrilação Atrial/etiologia , Eletrocardiografia Ambulatorial/instrumentação , Oclusão da Artéria Retiniana/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
13.
Pacing Clin Electrophysiol ; 42(10): 1331-1339, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31424091

RESUMO

BACKGROUND: Enterococcal cardiovascular implantable electronic device (CIED) infections are not well characterized. METHODS: Data from the Multicenter Electrophysiologic Device Infection Cohort, a prospective study of CIED infections, were used for descriptive analysis of adults with enterococcal CIED infections. RESULTS: Of 433 patients, 21 (4.8%) had enterococcal CIED infection. Median age was 71 years. Twelve patients (57%) had permanent pacemakers, five (24%) implantable cardioverter defibrillators, and four (19%) biventricular devices. Median time from last procedure to infection was 570 days. CIED-related bloodstream infections occurred in three patients (14%) and 18 (86%) had infective endocarditis (IE), 14 (78%) of which were definite by the modified Duke criteria. IE cases were classified as follows: valvular IE, four; lead IE, eight; both valve and lead IE, six. Vegetations were demonstrated by transesophageal echocardiography in 17 patients (81%). Blood cultures were positive in 19/19 patients with confirmed results. The most common antimicrobial regimen was penicillin plus an aminoglycoside (33%). Antibiotics were given for a median of 43 days. Only 14 patients (67%) underwent device removal. There was one death during the index hospitalization with four additional deaths within 6 months (overall mortality 24%). There were no relapses. CONCLUSIONS: Enterococci caused 4.8% of CIED infections in our cohort. Based on the late onset after device placement or manipulation, most infections were likely hematogenous in origin. IE was the most common infection syndrome. Only 67% of patients underwent device removal. At 6 months follow-up, no CIED infection relapses had occurred, but overall mortality was 24%.


Assuntos
Desfibriladores Implantáveis/microbiologia , Endocardite Bacteriana/microbiologia , Enterococcus/isolamento & purificação , Infecções por Bactérias Gram-Positivas/microbiologia , Marca-Passo Artificial/microbiologia , Complicações Pós-Operatórias/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Ecocardiografia Transesofagiana , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/tratamento farmacológico , Feminino , Infecções por Bactérias Gram-Positivas/diagnóstico por imagem , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/tratamento farmacológico
15.
JACC Clin Electrophysiol ; 4(2): 201-208, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29749938

RESUMO

OBJECTIVES: This study sought to evaluate the impact of abandoned cardiovascular implantable electronic device (CIED) leads on the presentation and management of device-related infections. BACKGROUND: Device infection is a serious consequence of CIEDs and necessitates removal of all hardware for attempted cure. The merits of extracting or retaining presumed sterile but nonfunctioning leads is a subject of ongoing debate. METHODS: The MEDIC (Multicenter Electrophysiologic Device Infection Cohort) prospectively enrolled patients with CIED infections at 10 institutions in the United States and abroad between January 1, 2009, and December 31, 2012. Within a propensity-matched cohort, relevant clinical information was compared between patients who had 1 or more abandoned leads at the time of infection and those who had none. RESULTS: Matching produced a cohort of 264 patients, including 176 with no abandoned leads and 88 with abandoned leads. The groups were balanced with respect to Charlson comorbidity index, oldest lead age, device type, sex, and race. At the time of admission, those with abandoned leads were less likely to demonstrate systemic signs of infection, including leukocytosis (p = 0.023) and positive blood cultures (p = 0.005). Conversely, patients with abandoned leads were more likely to demonstrate local signs of infections, including skin erosion (p = 0.031) and positive pocket cultures (p = 0.015). In addition, patients with abandoned leads were more likely to require laser extraction (p = 0.010). CONCLUSIONS: The results of a large prospective registry of CIED infections demonstrated that patients with abandoned leads may present with different signs, symptoms, and microbiological findings and require laser extraction more than those without abandoned leads.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Falha de Prótese/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Idoso , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade
16.
Open Heart ; 5(1): e000681, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29632673

RESUMO

Objective: To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation. Methods: We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoperation from 11 centres. Results: There were 432 patients with CIED infection, 178 occurring after initial device placement and 254 after repeat reoperation. No differences were seen in age, sex or device type. Those with infection after initial implant had a higher Charlson Comorbidity Score (median 3 (IQR 2-6) vs 2 (IQR 1-4), p<0.001), shorter time since last procedure (median 8.9 months (IQR 0.9-33.3) vs 19.5 months (IQR 1.1-62.9), p<0.0001) and fewer leads (2.0±0.6vs 2.5±0.9, p<0.001). Pocket infections were more likely to occur after a reoperation (70.1%vs48.9%, p<0.001) and coagulase negative staphylococci (CoNS) was the most frequently isolated organism in this group (p=0.029). In contrast, initial implant infections were more likely to present with higher white cell count (10.5±5.1 g/dL vs 9.5±5.4 g/dL, p=0.025), metastatic foci of infection (16.9%vs8.7%, p=0.016) and sepsis (30.9%vs19.3%, p=0.006). There were no differences in in-hospital (7.9%vs5.2%, p=0.31) or 6-month mortality (21.9%vs14.0%, p=0.056). Conclusions: CIED infections after initial device implant occur earlier, more aggressively, and often due to Staphylococcus aureus. In contrast, CIED infections after reoperation occur later, are due to CoNS, and have more indolent manifestations with primary localisation to the pocket.

17.
Pacing Clin Electrophysiol ; 41(5): 524-531, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29518265

RESUMO

BACKGROUND: Published guidelines mandate complete device removal in cases of cardiovascular implantable electronic device (CIED) infection. Clinical predictors of successful salvage of infected CIEDs have not been defined. METHODS: Data from the Multicenter Electrophysiologic Device Infection Collaboration, a prospective, observational, multinational cohort study of CIED infection, were used to investigate whether clinical predictors of successful salvage of infected devices could be identified. RESULTS: Of 433 adult patients with CIED infections, 306 (71%) underwent immediate device explantation. Medical management with device retention and antimicrobial therapy was initially attempted in 127 patients (29%). "Early failure" of attempted salvage occurred in 74 patients (58%) who subsequently underwent device explantation during the index hospitalization. The remaining 53 patients (42%) in the attempted salvage group retained their CIED. Twenty-six (49%) had resolution of CIED infection (successful salvage group) whereas 27 patients (51%) experienced "late" salvage failure. Upon comparing the salvage failure group, early and late (N = 101), to the group experiencing successful salvage of an infected CIED (N = 26), no clinical or laboratory predictors of successful salvage were identified. However, by univariate analysis, coagulase-negative staphylococci as infecting pathogens (P = 0.0439) and the presence of a lead vegetation (P = 0.024) were associated with overall failed salvage. CONCLUSIONS: In patients with definite CIED infections, clinical and laboratory variables cannot predict successful device salvage. Until new data are forthcoming, device explantation should remain a mandatory and early management intervention in patients with CIED infection in keeping with existing expert guidelines unless medical contraindications exist or patients refuse device removal.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese/terapia , Terapia de Salvação , Idoso , Remoção de Dispositivo , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Falha de Tratamento
18.
Pacing Clin Electrophysiol ; 41(5): 495-503, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29411401

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) infection is a serious adverse event, but there are limited contemporary real-world data on treatment pathways and associated costs in the Medicare population following diagnosis of CIED infection. Hence, this study evaluates postinfection treatment pathways and associated healthcare expenditures and mortality among Medicare fee-for-service beneficiaries with CIED infection. METHODS: Retrospective cohort analysis of 5,401 beneficiaries who developed a device-related infection in the year following implantation/upgraded CIED (1/1/2010-12/31/2012). Patients were followed-up to 12 months/death following diagnosis of infection and were divided into mutually exclusive groups based on whether they underwent CIED system removal (Group I), or no CIED system intervention (Group II; IIA with or IIB without infection hospitalization). All-cause healthcare resource utilization/expenditures were also measured. RESULTS: In the year following infection, 64.1% of patients underwent device extraction, of who 2,109 (39.0%) had their device replaced (Group IA) and 1,355 (25.1%) had their device extracted without replacement (Group IB); 62.2% of patients were hospitalized and 25.3% of patients died. Mean Medicare payments-per-patient for facility-based services by group were: IA = $62,638 (standard deviation [SD]: $46,830), IB = $50,079 (SD: $45,006), IIA = $77,397 (SD: $79,130), and IIB = $22,856 (SD: $31,167). CONCLUSIONS: Hospitalizations were the largest cost driver; infection-related costs, including cost of extraction/replacement, accounted for >50% of expenditures for patients with surgical/hospital intervention. Management of CIED infection in Medicare beneficiaries is associated with high healthcare expenditures in the year following infection. Additional measures to prevent device infection are needed to improve the outcomes and reduce costs in these patients.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Medicare/economia , Infecções Relacionadas à Prótese/economia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/terapia , Idoso , Remoção de Dispositivo , Feminino , Hospitalização/economia , Humanos , Masculino , Estudos Retrospectivos , Estados Unidos
19.
J Interv Card Electrophysiol ; 50(2): 149-158, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29110166

RESUMO

INTRODUCTION: The effects of device and patient characteristics on health and economic outcomes in patients with cardiac implantable electronic devices (CIEDs) are unclear. Modeling can estimate costs and outcomes for patients with CIEDs under a variety of scenarios, varying battery longevity, comorbidities, and care settings. The objective of this analysis was to compare changes in patient outcomes and payer costs attributable to increases in battery life of implantable cardiac defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). METHODS AND RESULTS: We developed a Monte Carlo Markov model simulation to follow patients through primary implant, postoperative maintenance, generator replacement, and revision states. Patients were simulated in 3-month increments for 15 years or until death. Key variables included Charlson Comorbidity Index, CIED type, legacy versus extended battery longevity, mortality rates (procedure and all-cause), infection and non-infectious complication rates, and care settings. Costs included procedure-related (facility and professional), maintenance, and infections and non-infectious complications, all derived from Medicare data (2004-2014, 5% sample). Outcomes included counts of battery replacements, revisions, infections and non-infectious complications, and discounted (3%) costs and life years. An increase in battery longevity in ICDs yielded reductions in numbers of revisions (by 23%), battery changes (by 44%), infections (by 23%), non-infectious complications (by 10%), and total costs per patient (by 9%). Analogous reductions for CRT-Ds were 23% (revisions), 32% (battery changes), 22% (infections), 8% (complications), and 10% (costs). CONCLUSION: Based on modeling results, as battery longevity increases, patients experience fewer adverse outcomes and healthcare costs are reduced. Understanding the magnitude of the cost benefit of extended battery life can inform budgeting and planning decisions by healthcare providers and insurers.


Assuntos
Redução de Custos , Desfibriladores Implantáveis/economia , Fontes de Energia Elétrica/economia , Custos de Cuidados de Saúde , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Análise Custo-Benefício , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/economia , Fontes de Energia Elétrica/efeitos adversos , Falha de Equipamento/economia , Feminino , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Medicare/economia , Pessoa de Meia-Idade , Método de Monte Carlo , Avaliação de Resultados em Cuidados de Saúde , Estados Unidos
20.
Artigo em Inglês | MEDLINE | ID: mdl-28292753

RESUMO

BACKGROUND: Infection is a serious complication of cardiovascular-implantable electronic device implantation and necessitates removal of all hardware for optimal treatment. Strategies for reimplanting hardware after infection vary widely and have not previously been analyzed using a large, multicenter study. METHODS AND RESULTS: The MEDIC (Multicenter Electrophysiologic Device Infection Cohort) prospectively enrolled subjects with cardiovascular-implantable electronic device infections at multiple institutions in the United States and abroad between 2009 and 2012. Reimplantation strategies were evaluated overall, and every patient who relapsed within 6 months was individually examined for clinical information that could help explain the negative outcome. Overall, 434 patients with cardiovascular-implantable electronic device infections were prospectively enrolled at participating centers. During the initial course of therapy, complete device removal was done in 381 patients (87.8%), and 220 of them (57.7%) were ultimately reimplanted with new devices. Overall, the median time between removal and reimplantation was 10 days, with an interquartile range of 6 to 19 days. Eleven of the 434 patients had another infection within 6 months, but only 4 of them were managed with cardiovascular-implantable electronic device removal and reimplantation during the initial infection. Thus, the repeat infection rate was low (1.8%) in those who were reimplanted. Patients who retained original hardware had a 11.3% repeat infection rate. CONCLUSIONS: Our study findings confirm that a broad range of reimplant strategies are used in clinical practice. They suggest that it is safe to reimplant cardiac devices after extraction of previously infected hardware and that the risk of a second infection is low, regardless of reimplant timing.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/terapia , Idoso , Arritmias Cardíacas/diagnóstico , Infecções Cardiovasculares/diagnóstico , Infecções Cardiovasculares/terapia , Estudos de Coortes , Bases de Dados Factuais , Fenômenos Eletrofisiológicos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Recidiva , Retratamento/métodos , Medição de Risco , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA