Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 32(5): 817-823, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29204771

RESUMO

The aim of this study was to evaluate the accuracy and precision of non-invasive continuous blood pressure measurement by applanation tonometry (AT) in awake or anaesthetised cardiological intensive care patients. Patients suffering from highly impaired left ventricular function atrial fibrillation or severe aortic valve stenosis were included into the study. Arterial blood pressure was recorded by applanation tonometry (T-Line 400, Tensys Medical®, USA) and an arterial line in awake or anaesthetised patients. Discrepancies in mean (MAP), systolic (SAP), and diastolic (DAP) arterial pressure between the two methods were assessed as bias, limits of agreement and percentage error respectively. In 31 patients a total of 27,900 measurements were analyzed. The concordance correlation coefficient was 0.23, 0.45 and 0.06 for MAP, SAP and DAP, respectively. For all patients bias for MAPAT compared to MAPAL was 14.96 mmHg (SAPAT 4.51 mmHg; DAPAT 19.12 mmHg) with limits of agreement for MAPAT of 46.25 and - 16.33 mm Hg (SAPAT 48.00 and - 38.98 mmHg; DAPAT 50.12 and - 11.89 mmHg). Percentage error for MAPAT was 56.8% (42.7% for SAPAT; 75.2% for DAPAT). We conclude that the AT method is not reliable in ICU patients with severe cardiac comorbidities.


Assuntos
Determinação da Pressão Arterial/métodos , Monitorização Hemodinâmica/métodos , Manometria/métodos , Idoso , Estenose da Valva Aórtica/fisiopatologia , Pressão Arterial/fisiologia , Fibrilação Atrial/fisiopatologia , Determinação da Pressão Arterial/estatística & dados numéricos , Unidades de Cuidados Coronarianos , Cuidados Críticos , Feminino , Monitorização Hemodinâmica/estatística & dados numéricos , Humanos , Masculino , Manometria/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia , Análise de Ondaletas
2.
Br J Anaesth ; 116(6): 790-6, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27095239

RESUMO

BACKGROUND: The aim of this study was to evaluate the validity of non-invasive continuous BP measurement by applanation tonometry in morbidly obese patients undergoing bariatric surgery. METHODS: Arterial blood pressure (AP) was recorded intraoperatively both by applanation tonometry (AT) (T-Line 200pro, Tensys Medical(®), USA) and an arterial line (AL) after radial cannulation in obese patients undergoing bariatric surgery. Discrepancies between the two methods were assessed as bias, limits of agreement and percentage error. Mean, systolic, and diastolic arterial pressures were assessed (MAP, SAP, DAP respectively). Trending ability was assessed by concordance based on four-quadrant plotting. RESULTS: Mean (sd) BMI of the 28 patients was 49.4 (9.7 kg m(-2)). A total of 201 907 time points were available for analysis. Bias for MAPAT compared with MAPAL was +3.97 mm Hg (SAPAT +3.45 mm Hg; DAPAT +3.66 mm Hg) with limits of agreement for MAPAT of -14.47 and +22.41 mm Hg (SAPAT -22.0 and +28.9 mm Hg; DAPAT -15.7 and +23.1 mm Hg). Percentage error for MAPAT was 23.5% (23.4% for SAPAT; 30.5% for DAPAT). Trending ability for MAP, SAP, and DAP revealed a concordance of 0.74, 0.72, and 0.71, respectively. CONCLUSIONS: Continuous BP assessment by applanation tonometry is feasible in morbidly obese patients undergoing bariatric surgery. However, despite a low mean difference, 95% limits of agreement and trending ability indicate that the technology needs to be improved further, before being recommended for routine use in this group of patients.


Assuntos
Pressão Arterial , Cirurgia Bariátrica/métodos , Determinação da Pressão Arterial/métodos , Manometria/métodos , Monitorização Intraoperatória/métodos , Obesidade Mórbida/fisiopatologia , Obesidade Mórbida/cirurgia , Adulto , Idoso , Índice de Massa Corporal , Cuidados Críticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA