Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
2.
Gastroenterol Hepatol (N Y) ; 20(3): 183-185, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38680173
3.
Gastrointest Endosc ; 99(4): 483-489.e2, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38416097

RESUMO

BACKGROUND AND AIMS: The use of artificial intelligence (AI) has transformative implications to the practice of gastroenterology and endoscopy. The aims of this study were to understand the perceptions of the gastroenterology community toward AI and to identify potential barriers for adoption. METHODS: A 16-question online survey exploring perceptions on the current and future implications of AI to the field of gastroenterology was developed by the American Society for Gastrointestinal Endoscopy AI Task Force and distributed to national and international society members. Participant demographic information including age, sex, experience level, and practice setting was collected. Descriptive statistics were used to summarize survey findings, and a Pearson χ2 analysis was performed to determine the association between participant demographic information and perceptions of AI. RESULTS: Of 10,162 invited gastroenterologists, 374 completed the survey. The mean age of participants was 46 years (standard deviation, 12), and 299 participants (80.0%) were men. One hundred seventy-nine participants (47.9%) had >10 years of practice experience, with nearly half working in the community setting. Only 25 participants (6.7%) reported the current use of AI in their clinical practice. Most participants (95.5%) believed that AI solutions will have a positive impact in their practice. One hundred seventy-six participants (47.1%) believed that AI will make clinical duties more technical but will also ease the burden of the electronic medical record (54.0%). The top 3 areas where AI was predicted to be most influential were endoscopic lesion detection (65.3%), endoscopic lesion characterization (65.8%), and quality metrics (32.6%). Participants voiced a desire for education on topics such as the clinical use of AI applications (64.4%), the advantages and limitations of AI applications (57.0%), and the technical methodology of AI (44.7%). Most participants (42.8%) expressed that the cost of AI implementation should be covered by their hospital. Demographic characteristics significantly associated with this perception included participants' years in practice and practice setting. CONCLUSIONS: Gastroenterologists have an overall positive perception regarding the use of AI in clinical practice but voiced concerns regarding its technical aspects and coverage of costs associated with implementation. Further education on the clinical use of AI applications with understanding of the advantages and limitations appears to be valuable in promoting adoption.


Assuntos
Gastroenterologistas , Gastroenterologia , Médicos , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Inteligência Artificial , Benchmarking
4.
Am J Gastroenterol ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38235741

RESUMO

INTRODUCTION: Adenoma per colonoscopy (APC) has recently been proposed as a quality measure for colonoscopy. We evaluated the impact of a novel artificial intelligence (AI) system, compared with standard high-definition colonoscopy, for APC measurement. METHODS: This was a US-based, multicenter, prospective randomized trial examining a novel AI detection system (EW10-EC02) that enables a real-time colorectal polyp detection enabled with the colonoscope (CAD-EYE). Eligible average-risk subjects (45 years or older) undergoing screening or surveillance colonoscopy were randomized to undergo either CAD-EYE-assisted colonoscopy (CAC) or conventional colonoscopy (CC). Modified intention-to-treat analysis was performed for all patients who completed colonoscopy with the primary outcome of APC. Secondary outcomes included positive predictive value (total number of adenomas divided by total polyps removed) and adenoma detection rate. RESULTS: In modified intention-to-treat analysis, of 1,031 subjects (age: 59.1 ± 9.8 years; 49.9% male), 510 underwent CAC vs 523 underwent CC with no significant differences in age, gender, ethnicity, or colonoscopy indication between the 2 groups. CAC led to a significantly higher APC compared with CC: 0.99 ± 1.6 vs 0.85 ± 1.5, P = 0.02, incidence rate ratio 1.17 (1.03-1.33, P = 0.02) with no significant difference in the withdrawal time: 11.28 ± 4.59 minutes vs 10.8 ± 4.81 minutes; P = 0.11 between the 2 groups. Difference in positive predictive value of a polyp being an adenoma among CAC and CC was less than 10% threshold established: 48.6% vs 54%, 95% CI -9.56% to -1.48%. There were no significant differences in adenoma detection rate (46.9% vs 42.8%), advanced adenoma (6.5% vs 6.3%), sessile serrated lesion detection rate (12.9% vs 10.1%), and polyp detection rate (63.9% vs 59.3%) between the 2 groups. There was a higher polyp per colonoscopy with CAC compared with CC: 1.68 ± 2.1 vs 1.33 ± 1.8 (incidence rate ratio 1.27; 1.15-1.4; P < 0.01). DISCUSSION: Use of a novel AI detection system showed to a significantly higher number of adenomas per colonoscopy compared with conventional high-definition colonoscopy without any increase in colonoscopy withdrawal time, thus supporting the use of AI-assisted colonoscopy to improve colonoscopy quality ( ClinicalTrials.gov NCT04979962).

5.
Expert Rev Med Devices ; 20(12): 1087-1103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37934873

RESUMO

INTRODUCTION: Colorectal cancer (CRC) is the third most common malignancy and second leading cause of cancer-related mortality in the world. Adenoma detection rate (ADR), a quality indicator for colonoscopy, has gained prominence as it is inversely related to CRC incidence and mortality. As such, recent efforts have focused on developing novel colonoscopy devices and technologies to improve ADR. AREAS COVERED: The main objective of this paper is to provide an overview of advancements in the fields of colonoscopy mechanical attachments, artificial intelligence-assisted colonoscopy, and colonoscopy optical enhancements with respect to ADR. We accomplished this by performing a comprehensive search of multiple electronic databases from inception to September 2023. This review is intended to be an introduction to colonoscopy devices and technologies. EXPERT OPINION: Numerous mechanical attachments and optical enhancements have been developed that have the potential to improve ADR and AI has gone from being an inaccessible concept to a feasible means for improving ADR. While these advances are exciting and portend a change in what will be considered standard colonoscopy, they continue to require refinement. Future studies should focus on combining modalities to further improve ADR and exploring the use of these technologies in other facets of colonoscopy.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Inteligência Artificial , Colonoscopia , Adenoma/diagnóstico , Adenoma/epidemiologia , Incidência , Tecnologia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos
6.
Clin Transl Gastroenterol ; 14(10): e00640, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37747097

RESUMO

Colorectal cancer screening plays a vital role in early detection and removal of precancerous adenomas, contributing to decreased mortality rates. Most polyps found during colonoscopies are small and unlikely to harbor advanced neoplasia or invasive cancer, leading to the development of "leave-in-situ" and "resect-and-discard" approaches. These strategies could lead to significant cost savings and efficiencies, but their implementation has been hampered by concerns around financial incentives, medical-legal risks, and local rules for tissue handling. This article reviews the potential of artificial intelligence to enhance the accuracy of polyp diagnosis through computer-aided diagnosis (CADx). While the adoption of CADx in optical biopsy has shown mixed results, it has the potential to significantly improve the management of colorectal polyps. Several studies reviewed in this article highlight the varied results of CADx in optical biopsy for colorectal polyps. Although artificial intelligence does not consistently outperform expert endoscopists, it has the potential to serve as a beneficial secondary reader, aiding in accurate optical diagnosis and increasing the confidence of the endoscopist. These studies indicate that although CADx holds great potential, it is yet to fully meet the performance thresholds necessary for clinical implementation.


Assuntos
Adenoma , Pólipos do Colo , Humanos , Pólipos do Colo/diagnóstico , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Inteligência Artificial , Colonoscopia/métodos , Adenoma/diagnóstico , Adenoma/patologia , Imagem de Banda Estreita
7.
Gastroenterology ; 165(1): 244-251.e3, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061169

RESUMO

BACKGROUND & AIMS: Both computer-aided detection (CADe)-assisted and Endocuff-assisted colonoscopy have been found to increase adenoma detection. We investigated the performance of the combination of the 2 tools compared with CADe-assisted colonoscopy alone to detect colorectal neoplasias during colonoscopy in a multicenter randomized trial. METHODS: Men and women undergoing colonoscopy for colorectal cancer screening, polyp surveillance, or clincial indications at 6 centers in Italy and Switzerland were enrolled. Patients were assigned (1:1) to colonoscopy with the combinations of CADe (GI-Genius; Medtronic) and a mucosal exposure device (Endocuff Vision [ECV]; Olympus) or to CADe-assisted colonoscopy alone (control group). All detected lesions were removed and sent to histopathology for diagnosis. The primary outcome was adenoma detection rate (percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, advanced adenomas and serrated lesions detection rate, the rate of unnecessary polypectomies (polyp resection without histologically proven adenomas), and withdrawal time. RESULTS: From July 1, 2021 to May 31, 2022, there were 1316 subjects randomized and eligible for analysis; 660 to the ECV group, 656 to the control group). The adenoma detection rate was significantly higher in the ECV group (49.6%) than in the control group (44.0%) (relative risk, 1.12; 95% CI, 1.00-1.26; P = .04). Adenomas detected per colonoscopy were significantly higher in the ECV group (mean ± SD, 0.94 ± 0.54) than in the control group (0.74 ± 0.21) (incidence rate ratio, 1.26; 95% CI, 1.04-1.54; P = .02). The 2 groups did not differ in term of detection of advanced adenomas and serrated lesions. There was no significant difference between groups in mean ± SD withdrawal time (9.01 ± 2.48 seconds for the ECV group vs 8.96 ± 2.24 seconds for controls; P = .69) or proportion of subjects undergoing unnecessary polypectomies (relative risk, 0.89; 95% CI, 0.69-1.14; P = .38). CONCLUSIONS: The combination of CADe and ECV during colonoscopy increases adenoma detection rate and adenomas detected per colonoscopy without increasing withdrawal time compared with CADe alone. CLINICALTRIALS: gov, Number: NCT04676308.


Assuntos
Adenoma , Neoplasias Colorretais , Masculino , Humanos , Feminino , Colonoscopia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Mucosa , Computadores
8.
Gastrointest Endosc ; 97(5): 815-824.e1, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36764886

RESUMO

In the past few years, we have seen a surge in the development of relevant artificial intelligence (AI) algorithms addressing a variety of needs in GI endoscopy. To accept AI algorithms into clinical practice, their effectiveness, clinical value, and reliability need to be rigorously assessed. In this article, we provide a guiding framework for all stakeholders in the endoscopy AI ecosystem regarding the standards, metrics, and evaluation methods for emerging and existing AI applications to aid in their clinical adoption and implementation. We also provide guidance and best practices for evaluation of AI technologies as they mature in the endoscopy space. Note, this is a living document; periodic updates will be published as progress is made and applications evolve in the field of AI in endoscopy.


Assuntos
Inteligência Artificial , Benchmarking , Humanos , Ecossistema , Reprodutibilidade dos Testes , Algoritmos , Endoscopia Gastrointestinal
9.
Cancer Med ; 12(3): 2345-2355, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35906821

RESUMO

BACKGROUND: Genetic testing is recommended for all pancreatic ductal adenocarcinoma (PDAC) patients. Prior research demonstrates that multidisciplinary pancreatic cancer clinics (MDPCs) improve treatment- and survival-related outcomes for PDAC patients. However, limited information exists regarding the utility of integrated genetics in the MDPC setting. We hypothesized that incorporating genetics in an MDPC serving both PDAC patients and high-risk individuals (HRI) could: (1) improve compliance with guideline-based genetic testing for PDAC patients, and (2) optimize HRI identification and PDAC surveillance participation to improve early detection and survival. METHODS: Demographics, genetic testing results, and pedigrees were reviewed for PDAC patients and HRI at one institution over 45 months. Genetic testing analyzed 16 PDAC-associated genes at minimum. RESULTS: Overall, 969 MDPC subjects were evaluated during the study period; another 56 PDAC patients were seen outside the MDPC. Among 425 MDPC PDAC patients, 333 (78.4%) completed genetic testing; 29 (8.7%) carried a PDAC-related pathogenic germline variant (PGV). Additionally, 32 (9.6%) met familial pancreatic cancer (FPC) criteria. These PDAC patients had 191 relatives eligible for surveillance or genetic testing. Only 2/56 (3.6%) non-MDPC PDAC patients completed genetic testing (p < 0.01). Among 544 HRI, 253 (46.5%) had a known PGV or a designation of FPC, and were eligible for surveillance at baseline; of the remainder, 15/291 (5.2%) were eligible following genetic testing and PGV identification. CONCLUSION: Integrating genetics into the multidisciplinary setting significantly improved genetic testing compliance by reducing logistical barriers for PDAC patients, and clarified cancer risks for their relatives while conserving clinical resources. Overall, we identified 206 individuals newly eligible for surveillance or genetic testing (191 relatives of MDPC PDAC patients, and 15 HRI from this cohort), enabling continuity of care for PDAC patients and at-risk relatives in one clinic.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Predisposição Genética para Doença , Neoplasias Pancreáticas/patologia , Testes Genéticos , Carcinoma Ductal Pancreático/patologia , Neoplasias Pancreáticas
10.
Clin Gastroenterol Hepatol ; 21(4): 949-959.e2, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36038128

RESUMO

BACKGROUND AND AIMS: Artificial intelligence (AI) tools aimed at improving polyp detection have been shown to increase the adenoma detection rate during colonoscopy. However, it is unknown how increased polyp detection rates by AI affect the burden of patient surveillance after polyp removal. METHODS: We conducted a pooled analysis of 9 randomized controlled trials (5 in China, 2 in Italy, 1 in Japan, and 1 in the United States) comparing colonoscopy with or without AI detection aids. The primary outcome was the proportion of patients recommended to undergo intensive surveillance (ie, 3-year interval). We analyzed intervals for AI and non-AI colonoscopies for the U.S. and European recommendations separately. We estimated proportions by calculating relative risks using the Mantel-Haenszel method. RESULTS: A total of 5796 patients (51% male, mean 53 years of age) were included; 2894 underwent AI-assisted colonoscopy and 2902 non-AI colonoscopy. When following U.S. guidelines, the proportion of patients recommended intensive surveillance increased from 8.4% (95% CI, 7.4%-9.5%) in the non-AI group to 11.3% (95% CI, 10.2%-12.6%) in the AI group (absolute difference, 2.9% [95% CI, 1.4%-4.4%]; risk ratio, 1.35 [95% CI, 1.16-1.57]). When following European guidelines, it increased from 6.1% (95% CI, 5.3%-7.0%) to 7.4% (95% CI, 6.5%-8.4%) (absolute difference, 1.3% [95% CI, 0.01%-2.6%]; risk ratio, 1.22 [95% CI, 1.01-1.47]). CONCLUSIONS: The use of AI during colonoscopy increased the proportion of patients requiring intensive colonoscopy surveillance by approximately 35% in the United States and 20% in Europe (absolute increases of 2.9% and 1.3%, respectively). While this may contribute to improved cancer prevention, it significantly adds patient burden and healthcare costs.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Masculino , Feminino , Pólipos do Colo/diagnóstico , Pólipos do Colo/cirurgia , Pólipos do Colo/epidemiologia , Inteligência Artificial , Ensaios Clínicos Controlados Aleatórios como Assunto , Colonoscopia/métodos , Adenoma/diagnóstico , Adenoma/cirurgia , Adenoma/epidemiologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/epidemiologia
11.
Curr Opin Gastroenterol ; 38(5): 430-435, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35894671

RESUMO

PURPOSE OF REVIEW: Colorectal cancer continues to be one of the most common causes of cancer-related death. Widespread dissemination of screening colonoscopy in the United States has led to a significant reduction in the incidence and mortality. Here we review current literature with an aim to highlight recent improvements in the safety, efficiency, and effectiveness of screening colonoscopy. RECENT FINDINGS: Colon capsule endoscopy is an emerging noninvasive method to capture images of colonic mucosa for select patients with appreciable sensitivity for polyp detection. Recent literature supports the use of the novel oral anticoagulant apixaban over other anticoagulants to reduce the risk of gastrointestinal bleeding related to colonoscopy. Cold snare polypectomy for smaller lesions and prophylactic clipping following resection of large polyps in the proximal colon may reduce the rate of delayed bleeding. Novel methods and devices for improving bowel preparation continue to emerge. Mechanical attachment devices and artificial intelligence represent recent innovations to improve polyp detection. SUMMARY: Clinicians should be aware of relevant data and literature that continue to improve the quality and safety of screening colonoscopy and incorporate these findings into their clinical practice.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Inteligência Artificial , Colo/patologia , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Neoplasias Colorretais/prevenção & controle , Humanos , Programas de Rastreamento
12.
Gastrointest Endosc ; 96(3): 402-410, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35667390

RESUMO

Since its inception, endoscopy has evolved from a solely diagnostic procedure to an expanding therapeutic field within gastroenterology. The incorporation of robotics in gastroenterology initially addressed shortcomings of flexible endoscopes in natural orifice transluminal endoscopy. Developing therapeutic endoscopic robotic platforms now offer operators improved ergonomics, visualization, dexterity, precision, and control and the possibility of increasing proficiency and standardization of complex endoscopic procedures including endoscopic submucosal dissection, endoscopic full-thickness resection, and endoscopic suturing. The following review discusses the history, potential applications, and tools currently available and in development for robotics in therapeutic endoscopy.


Assuntos
Ressecção Endoscópica de Mucosa , Cirurgia Endoscópica por Orifício Natural , Robótica , Endoscópios , Endoscopia/métodos , Endoscopia Gastrointestinal , Humanos , Cirurgia Endoscópica por Orifício Natural/métodos , Robótica/métodos
14.
BMC Gastroenterol ; 22(1): 236, 2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35550029

RESUMO

BACKGROUND: Capsule endoscopy (CE) provides a novel approach to evaluate obscure gastrointestinal bleeding. Yet CE is not routinely utilized in the inpatient setting for a variety of reasons. We sought to identify factors that predict complete CE and diagnostically meaningful CE, as well as assess the impact of inpatient CE on further hospital management.1 na d2 METHODS: We conducted a retrospective review of patients undergoing inpatient CE at a tertiary referral, academic center over a 3 year period. We analyzed data on patient demographics, medical history, endoscopic procedures, hospital course, and results of CE. The primary outcome was complete CE and the secondary outcome was positive findings of pathology on CE. RESULTS: 131 patients were included (56.5% were men 43.5% women, median age of 71.0 years). Overall, CE was complete in 77.1% of patients. Complete CE was not related to motility risk factors, gender, or administration modality. Patients with incomplete CE tended to be older, have lower BMI, and Caucasian, however results did not reach statistical significance (p = 0.06; p = 0.06; p = 0.08 respectively). Positive CE was noted in 73.3% of patients, with 35.1% of all patients having active bleeding. Positive CE was not associated with AVM risk factors or medication use. 28.0% of patients underwent subsequent hospital procedures, among which 67.6% identified the same pathology seen on CE. CONCLUSIONS: Contrary to previous studies, we found the majority of inpatient CEs were complete and positive for pathology. We found high rates of correlation between CE and subsequent procedures. The use of CE in the inpatient setting helps to guide the diagnosis and treatment of hospitalized patients with obscure gastrointestinal bleeding.


Assuntos
Endoscopia por Cápsula , Idoso , Endoscopia por Cápsula/efeitos adversos , Endoscopia Gastrointestinal/métodos , Feminino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/patologia , Humanos , Pacientes Internados , Masculino , Encaminhamento e Consulta , Estudos Retrospectivos
16.
Clin Gastroenterol Hepatol ; 20(7): 1499-1507.e4, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34530161

RESUMO

BACKGROUND & AIMS: Artificial intelligence-based computer-aided polyp detection (CADe) systems are intended to address the issue of missed polyps during colonoscopy. The effect of CADe during screening and surveillance colonoscopy has not previously been studied in a United States (U.S.) population. METHODS: We conducted a prospective, multi-center, single-blind randomized tandem colonoscopy study to evaluate a deep-learning based CADe system (EndoScreener, Shanghai Wision AI, China). Patients were enrolled across 4 U.S. academic medical centers from 2019 through 2020. Patients presenting for colorectal cancer screening or surveillance were randomized to CADe colonoscopy first or high-definition white light (HDWL) colonoscopy first, followed immediately by the other procedure in tandem fashion by the same endoscopist. The primary outcome was adenoma miss rate (AMR), and secondary outcomes included sessile serrated lesion (SSL) miss rate and adenomas per colonoscopy (APC). RESULTS: A total of 232 patients entered the study, with 116 patients randomized to undergo CADe colonoscopy first and 116 patients randomized to undergo HDWL colonoscopy first. After the exclusion of 9 patients, the study cohort included 223 patients. AMR was lower in the CADe-first group compared with the HDWL-first group (20.12% [34/169] vs 31.25% [45/144]; odds ratio [OR], 1.8048; 95% confidence interval [CI], 1.0780-3.0217; P = .0247). SSL miss rate was lower in the CADe-first group (7.14% [1/14]) vs the HDWL-first group (42.11% [8/19]; P = .0482). First-pass APC was higher in the CADe-first group (1.19 [standard deviation (SD), 2.03] vs 0.90 [SD, 1.55]; P = .0323). First-pass ADR was 50.44% in the CADe-first group and 43.64 % in the HDWL-first group (P = .3091). CONCLUSION: In this U.S. multicenter tandem colonoscopy randomized controlled trial, we demonstrate a decrease in AMR and SSL miss rate and an increase in first-pass APC with the use of a CADe-system when compared with HDWL colonoscopy alone.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Aprendizado Profundo , Diagnóstico por Computador , Adenoma/diagnóstico , Adenoma/patologia , Inteligência Artificial , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Humanos , Diagnóstico Ausente , Estudos Prospectivos , Método Simples-Cego , Estados Unidos
17.
Am J Gastroenterol ; 117(1): 57-69, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34962727

RESUMO

This document is a focused update to the 2017 colorectal cancer (CRC) screening recommendations from the U.S. Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology, the American Gastroenterological Association, and the American Society for Gastrointestinal Endoscopy. This update is restricted to addressing the age to start and stop CRC screening in average-risk individuals and the recommended screening modalities. Although there is no literature demonstrating that CRC screening in individuals under age 50 improves health outcomes such as CRC incidence or CRC-related mortality, sufficient data support the U.S. Multi-Society Task Force to suggest average-risk CRC screening begin at age 45. This recommendation is based on the increasing disease burden among individuals under age 50, emerging data that the prevalence of advanced colorectal neoplasia in individuals ages 45 to 49 approaches rates in individuals 50 to 59, and modeling studies that demonstrate the benefits of screening outweigh the potential harms and costs. For individuals ages 76 to 85, the decision to start or continue screening should be individualized and based on prior screening history, life expectancy, CRC risk, and personal preference. Screening is not recommended after age 85.


Assuntos
Colonoscopia/normas , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/normas , Gastroenterologia , Guias de Prática Clínica como Assunto , Medição de Risco/métodos , Sociedades Médicas , Fatores Etários , Neoplasias Colorretais/epidemiologia , Humanos , Incidência , Fatores de Risco , Estados Unidos
18.
Gastrointest Endosc ; 95(1): 1-15, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34794803

RESUMO

This document is a focused update to the 2017 colorectal cancer (CRC) screening recommendations from the U.S. Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology, the American Gastroenterological Association, and the American Society for Gastrointestinal Endoscopy. This update is restricted to addressing the age to start and stop CRC screening in average-risk individuals and the recommended screening modalities. Although there is no literature demonstrating that CRC screening in individuals under age 50 improves health outcomes such as CRC incidence or CRC-related mortality, sufficient data support the U.S. Multi-Society Task Force to suggest average-risk CRC screening begin at age 45. This recommendation is based on the increasing disease burden among individuals under age 50, emerging data that the prevalence of advanced colorectal neoplasia in individuals ages 45 to 49 approaches rates in individuals 50 to 59, and modeling studies that demonstrate the benefits of screening outweigh the potential harms and costs. For individuals ages 76 to 85, the decision to start or continue screening should be individualized and based on prior screening history, life expectancy, CRC risk, and personal preference. Screening is not recommended after age 85.


Assuntos
Neoplasias Colorretais , Gastroenterologia , Idoso , Idoso de 80 Anos ou mais , Colonoscopia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Detecção Precoce de Câncer , Humanos , Incidência , Programas de Rastreamento , Pessoa de Meia-Idade , Estados Unidos/epidemiologia
19.
Gastroenterology ; 162(1): 285-299, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34794816

RESUMO

This document is a focused update to the 2017 colorectal cancer (CRC) screening recommendations from the U.S. Multi-Society Task Force on Colorectal Cancer, which represents the American College of Gastroenterology, the American Gastroenterological Association, and the American Society for Gastrointestinal Endoscopy. This update is restricted to addressing the age to start and stop CRC screening in average-risk individuals and the recommended screening modalities. Although there is no literature demonstrating that CRC screening in individuals under age 50 improves health outcomes such as CRC incidence or CRC-related mortality, sufficient data support the U.S. Multi-Society Task Force to suggest average-risk CRC screening begin at age 45. This recommendation is based on the increasing disease burden among individuals under age 50, emerging data that the prevalence of advanced colorectal neoplasia in individuals ages 45 to 49 approaches rates in individuals 50 to 59, and modeling studies that demonstrate the benefits of screening outweigh the potential harms and costs. For individuals ages 76 to 85, the decision to start or continue screening should be individualized and based on prior screening history, life expectancy, CRC risk, and personal preference. Screening is not recommended after age 85.


Assuntos
Colonoscopia/normas , Neoplasias Colorretais/patologia , Detecção Precoce de Câncer/normas , Lesões Pré-Cancerosas/patologia , Adenocarcinoma/epidemiologia , Adenocarcinoma/patologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Tomada de Decisão Clínica , Colonoscopia/efeitos adversos , Neoplasias Colorretais/epidemiologia , Consenso , Detecção Precoce de Câncer/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Lesões Pré-Cancerosas/epidemiologia , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Estados Unidos/epidemiologia
20.
Dig Dis Sci ; 67(8): 4070-4077, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34708286

RESUMO

BACKGROUND: Current strategies to prevent colorectal cancer (CRC) vary considerably regarding safety, invasiveness, and patient satisfaction. A known deterrent for patients is the required bowel cleansing for colonoscopy. A new colon-scan capsule system is a unique preparation-free approach that provides structural information on colonic mucosa intended for detection of colorectal polyps and masses. AIMS: The aim of this study was to determine safety and patient satisfaction with the colon-scan capsule. METHODS: Prospective single-arm pilot study conducted at two tertiary care centers. Patients with a pre-scheduled colonoscopy for CRC screening or surveillance were included. Patients participating in this study underwent the colon-scan capsule and colonoscopy. Safety was defined by the occurrence of procedure or device-related adverse events. Satisfaction was based on survey questionnaires using a scoring system 1 (strongly disagree) to 5 (strongly agree). Patient satisfaction with the colon-scan capsule was compared to colonoscopy. RESULTS: Forty patients were included (52.9 [5.7] years; 64.1% females). There were no serious adverse events and no occurrences of capsule retention. The most common (12.5%) complaint was self-limiting abdominal cramping. Satisfaction questionnaires were completed by more than 87% of patients, with patients likely to recommend the capsule (score 4.1 [1.03]) compared to colonoscopy (score 2.8 [1.2]), p = 0.001. CONCLUSIONS: The new prepless colon-scan capsule system is an innovative, minimally invasive technology with demonstrated safety and high patient satisfaction. A multicenter pivotal study is planned to validate the performance, safety, and accuracy of polyp detection using the capsule system in comparison with colonoscopy.


Assuntos
Endoscopia por Cápsula , Pólipos do Colo , Neoplasias Colorretais , Endoscopia por Cápsula/efeitos adversos , Endoscopia por Cápsula/métodos , Catárticos , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/epidemiologia , Feminino , Humanos , Masculino , Satisfação do Paciente , Projetos Piloto , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA