Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Burn Care Res ; 29(2): 293-303, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18354285

RESUMO

The objective of this phase 3, multicentered, prospective, randomized, evaluator-blinded, clinical study was to compare skin graft adherence utilizing a fibrin sealant containing 4 IU/ml thrombin (FS 4IU VH S/D [FS 4IU VH S/D will be marketed under the trade name ARTISS upon licensure in the United States]) to graft adherence utilizing staples in burn patients requiring wound excision and skin grafting. FS 4IU VH S/D was compared with staples in 138 patients. Patients had burn wounds measuring < or =40% of total body surface area with two comparable test sites measuring between 1 and 4% total body surface area each. Wound closure at day 28 was assessed using test site planimetry and review of day 28 photographs by three independent blinded evaluators (primary endpoint analysis). Secondary efficacy measures included hematoma/seroma on day 1, engraftment on day 5, and wound closure on day 14. Investigator and patient-reported outcomes were also assessed. The proportion of test sites with complete wound closure at day 28 was 70.3% in FS 4IU VH S/D treated sites and 65.8% in stapled sites, as assessed by planimetry. Blinded review of day 28 photographs confirmed that the rate of complete wound closure was similar between the two treatments, although the overall assessed rates of closure were lower than those determined by planimetry: FS 4IU VH S/D (43.3%) and staples (37.0%). The lower limit of the 97.5% confidence interval of the difference between FS 4IU VH S/D and staples was -0.029, which is above the predefined noninferiority margin of -0.1. Therefore, FS 4IU VH S/D is at least as efficacious as staples at the 97.5% one-sided level for complete wound closure by day 28. Hematoma/seroma on day 1 occurred at significantly (P < .0001) fewer FS 4IU VH S/D-treated sites (29.7% [95% CI 22.2-38.1%]) compared with stapled sites (62.3% [95% CI 53.7-70.4%]). Engraftment on day 5 was deemed to be 100% in 62.3% (95% CI 53.7-70.4%) of the FS 4IU VH S/D-treated sites and 55.1% (95% CI 46.4-63.5%) of the stapled sites (P = .0890). Complete wound closure by day 14 occurred in 48.8% (95% CI 39.9-57.8%) of the FS 4IU VH S/D treated sites and 42.6% (95% CI 34.0-51.6%) of the stapled sites (P = .2299). FS 4IU VH S/D scored significantly better than staples for all investigator-assessed outcomes, namely quality of graft adherence (P < .0001), preference for method of fixation (P < .0001), satisfaction with graft fixation (P < .0001), and overall quality of healing (P < .0001). Likewise, FS 4IU VH S/D scored significantly better than staples for all patient-assessed outcomes, namely anxiety about pain (P < .0001) and treatment preference (P <.0001). The safety profile of FS 4IU VH S/D was excellent as indicated by the lack of any related serious adverse experiences. These findings demonstrate that FS 4IU VH S/D is safe and effective for attachment of skin grafts, with outcomes at least as good as or better than staple fixation.


Assuntos
Queimaduras/cirurgia , Adesivo Tecidual de Fibrina , Fibrina/uso terapêutico , Sobrevivência de Enxerto , Transplante de Pele , Adolescente , Adulto , Idoso , Queimaduras/terapia , Criança , Pré-Escolar , Feminino , Fibrina/administração & dosagem , Fibrina/efeitos adversos , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Cicatrização
2.
J Burn Care Res ; 28(3): 401-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17438504

RESUMO

We undertook a multicenter, randomized, controlled, phase 1/2 clinical study to investigate the safety and efficacy of a fibrin sealant containing 4 IU/ml thrombin (FS 4IU) for the attachment of autologous sheet grafts in patients with deep partial-thickness or full-thickness burn wounds. Fibrin sealant (FS 4IU) was compared with staples for adherence of sheet grafts in 40 patients. Patients had to have burn wounds measuring 40% TBSA or less with two comparable test sites measuring between 1% and 4% TBSA each. Wound beds were prepared before treatment assignment, which was randomized. Percent area of hematoma/seroma at Day 1 (P = .0138) and questionable viability at Day 5 (P = .0182) were significantly less for FS 4IU-treated sites. Median percent area of graft survival on Day 14 was 100% for both treatments (P = .3525). The percentage of completely closed sites generally was greater for FS 4IU-sites on Days 5 to 91; the maximum difference occurred at Day 28 (79.5% vs 59%; P = .0215). The safety profile of FS 4IU was excellent as indicated by the lack of any related serious adverse experiences. These findings indicate that FS 4IU is safe and effective for fixation of skin grafts, with outcomes similar to or better than staple fixation. The data suggest that FS 4IU is a promising candidate for further clinical studies focusing on skin graft adhesion and burn wound healing.


Assuntos
Queimaduras/cirurgia , Adesivo Tecidual de Fibrina/uso terapêutico , Transplante de Pele/métodos , Suturas , Trombina/uso terapêutico , Transplante Autólogo , Resultado do Tratamento , Cicatrização , Adolescente , Adulto , Idoso , Criança , Feminino , Adesivo Tecidual de Fibrina/efeitos adversos , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Trombina/efeitos adversos