Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38426911

RESUMO

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estimulação Cardíaca Artificial/efeitos adversos
2.
J Electrocardiol ; 81: 214-217, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37832325

RESUMO

We present the case of a 42 year old patient with a history of childhood lymphoma treated with chemotherapy and radiation who underwent combined aortic and mitral valve replacements and who postoperatively developed an interesting ECG which showed complete heart block and an alternating left bundle branch and narrow complex QRS pattern at a heart rate of 69 beats per minute (bpm). We discuss potential mechanisms for this interesting pattern.


Assuntos
Bloqueio Atrioventricular , Bloqueio de Ramo , Humanos , Adulto , Eletrocardiografia , Sistema de Condução Cardíaco , Frequência Cardíaca
4.
Heart Rhythm ; 20(4): 537-544, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36442824

RESUMO

BACKGROUND: Patients with ischemic cardiomyopathy, non-left bundle branch block, or QRS duration <150 ms have a lower response rate to cardiac resynchronization therapy (CRT) than did other indicated patients. The ECG Belt system (EBS) is a novel surface mapping system designed to measure electrical dyssynchrony via the standard deviation of the activation times of the left ventricle. OBJECTIVES: The objectives of this study were to evaluate the efficacy of the EBS in patients less likely to respond to CRT and to determine whether EBS use in lead placement guidance and device programming was superior to standard CRT care. METHODS: This was a prospective randomized trial of patients with heart failure and EBS-guided CRT implantation and programming vs standard CRT care. The primary end point was relative change in left ventricular end-systolic volume from baseline to 6 months postimplantation. RESULTS: A total of 408 patients from centers in Europe and North America were randomized. Although both patients with EBS and control patients had a mean improvement in left ventricular end-systolic volume, there was no significant difference in relative change from baseline (P = .26). While patients with a higher baseline standard deviation of the activation times derived greater left ventricular reverse remodeling, improvement in electrical dyssynchrony did not correlate with the extent of reverse remodeling. CONCLUSION: The findings of the present study do not support EBS-guided therapy for CRT management of heart failure with reduced ejection fraction.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Prospectivos , Ventrículos do Coração , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Remodelação Ventricular , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
5.
Heart Rhythm ; 19(2): 228-234, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34757189

RESUMO

BACKGROUND: Early results from the Micra investigational trial and Micra Post-Approval Registry (PAR) demonstrated excellent safety and device performance; however, outcomes based on anticoagulation (AC) status at implant have not been evaluated. OBJECTIVE: The purpose of this study was to report implant characteristics, perforation rate, and vascular-related events based on perioperative oral AC strategy in patients undergoing Micra implant. METHODS: We compared procedure characteristics, major complications, and vascular events, including pericardial effusion, stratified by any adverse event (including major complications, minor complications, and observations) or major complication only according to AC status in the Micra PAR. RESULTS: Among 1795 patients with AC status available, 585 were not on AC, 795 had AC interrupted, and 415 had AC continued during Micra implant. Non-AC patients tended to be younger, with less history of atrial fibrillation and chronic obstructive pulmonary disease, and more history of dialysis than interrupted and continued patients. The implant success rate was similar for all groups (99.1%-99.8%). Through 30 days postimplant, the overall major complication rate was 3.1% for the non-AC group, 2.6% for the interrupted group, and 1.5% for the continued group. The combined rate for any vascular or pericardial effusion adverse event did not differ significantly among AC strategies (6.5%, 4.8%, and 3.6%, respectively). CONCLUSION: Implant of Micra seems to be safe and feasible regardless of an interrupted or continued periprocedural oral AC strategy, with no increased risk of perforation or vascular complications.


Assuntos
Anticoagulantes/administração & dosagem , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Desenho de Prótese , Sistema de Registros
6.
Am J Cardiol ; 131: 122-124, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32718546

RESUMO

There have been no recent descriptions of the spontaneous conversion of long-standing atrial fibrillation (AF) or flutter (AFl) to sinus rhythm which, in the past, has been associated with rheumatic mitral valve disease and treatment with digoxin. We present 3 contemporary cases, all of whom progressed from AF to slow AFl and then spontaneously converted to slow sinus or junctional rhythm. None of these patients had rheumatic heart disease or were treated with digoxin. In conclusion, we believe that they provide support for the broader view that this uncommon phenomenon is associated with a severe atrial myopathy due to scar and inflammation.


Assuntos
Fibrilação Atrial/fisiopatologia , Flutter Atrial/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Eletrocardiografia , Mapeamento Epicárdico , Humanos , Masculino , Remissão Espontânea
8.
Heart Rhythm ; 15(6): 841-846, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29427820

RESUMO

BACKGROUND: Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval. OBJECTIVE: The purpose of this study was to report the worldwide experience with successful retrieval of the Micra TPS. METHODS: A list of all successful retrievals of the currently available leadless pacemakers (LPs) was obtained from the manufacturer of Micra TPS. Pertinent details of retrieval, such as indication, days postimplantation, equipment used, complications, and postretrieval management, were obtained from the database collected by the manufacturer. Other procedural details were obtained directly from the operators at each participating site. RESULTS: Data from the manufacturer consisted of 40 successful retrievals of the Micra TPS. Operators for 29 retrievals (73%) provided the consent and procedural details. Of the 29 retrievals, 11 patients underwent retrieval during the initial procedure (immediate retrieval); the other 18 patients underwent retrieval during a separate procedure (delayed retrieval). Median duration before delayed retrieval was 46 days (range 1-95 days). The most common reason for immediate retrieval was elevated pacing threshold after tether removal. The most common reasons for delayed retrieval included elevated pacing threshold at follow-up, endovascular infection, and need for transvenous device. Mean procedure duration was 63.11 ± 56 minutes. All retrievals involved snaring via a Micra TPS delivery catheter or steerable sheath. No serious complications occurred during the reported retrievals. CONCLUSION: Early retrieval of the Micra TPS is feasible and safe.


Assuntos
Arritmias Cardíacas/terapia , Cateteres Cardíacos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Cirurgia Assistida por Computador/métodos , Desenho de Equipamento , Fluoroscopia , Seguimentos , Humanos , Estudos Retrospectivos , Fatores de Tempo
9.
Heart Rhythm ; 14(12): 1801-1806, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28713024

RESUMO

BACKGROUND: Early experience with leadless pacemakers has shown a low rate of complications. However, little is known about system revision in patients with these devices. OBJECTIVE: The purpose of this study was to describe the system revision experience with the Micra Transcatheter Pacing System (TPS). METHODS: Patients with implants from the Pre-market Micra Transcatheter Pacing Study and the Micra Transcatheter Pacing System Continued Access Study (N = 989) were analyzed and compared with 2667 patients with transvenous pacemakers (TVPs). Revisions included TPS retrieval/explant, repositioning, replacement, or electrical deactivation (with or without prior attempt at retrieval, generally followed by TVP implant) for any reason. Kaplan-Meier revision rates were calculated to account for varying follow-up duration and were compared using a Fine-Gray competing risk model. RESULTS: The actuarial rate for revision at 24 months postimplant was 1.4% for the TPS group (11 revisions in 10 patients), 75% (95% confidence interval 53%-87%; P < .001) lower than the 5.3% for the TVP group (123 revisions in 117 patients). TPS revisions occurred 5-430 days postimplant for elevated pacing thresholds, need for alternate therapy, pacemaker syndrome, and prosthetic valve endocarditis; none were due to device dislodgment or device-related infection. TPS was disabled and left in situ in 7 cases, 3 were retrieved percutaneously (range 9-406 days postimplant), and 1 was surgically removed during aortic valve surgery. CONCLUSION: The overall system revision rate for patients with TPS at 24 months was 1.4%, 75% lower than that for patients with TVPs. TPS was disabled and left in situ in 64% of revisions, and percutaneous retrieval was successful as late as 14 months postimplant.


Assuntos
Arritmias Cardíacas/terapia , Cateteres Cardíacos , Tomada de Decisões , Remoção de Dispositivo/instrumentação , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/mortalidade , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA