2.
Heart Rhythm ; 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38296010

RESUMO

BACKGROUND: Targeting non-pulmonary vein triggers (NPVTs) after pulmonary vein isolation may reduce atrial fibrillation (AF) recurrence. Isoproterenol infusion and cardioversion of spontaneous or induced AF can provoke NPVTs but typically require vasopressor support and increased procedural time. OBJECTIVE: The purpose of this study was to identify risk factors for the presence of NPVTs and create a risk score to identify higher-risk subgroups. METHODS: Using the AF ablation registry at the Hospital of the University of Pennsylvania, we included consecutive patients who underwent AF ablation between January 2021 and December 2022. We excluded patients who did not receive NPVT provocation testing after failing to demonstrate spontaneous NPVTs. NPVTs were defined as non-pulmonary vein ectopic beats triggering AF or focal atrial tachycardia. We used risk factors associated with NPVTs with P <.1 in multivariable logistic regression model to create a risk score in a randomly split derivation set (80%) and tested its predictive accuracy in the validation set (20%). RESULTS: In 1530 AF ablations included, NPVTs were observed in 235 (15.4%). In the derivation set, female sex (odds ratio [OR] 1.40; 95% confidence interval [CI] 0.96-2.03; P = .080), sinus node dysfunction (OR 1.67; 95% CI 0.98-2.87; P = .060), previous AF ablation (OR 2.50; 95% CI 1.70-3.65; P <.001), and left atrial scar (OR 2.90; 95% CI 1.94-4.36; P <.001) were risk factors associated with NPVTs. The risk score created from these risk factors (PRE2SSS2 score; [PRE]vious ablation: 2 points, female [S]ex: 1 point, [S]inus node dysfunction: 1 point, left atrial [S]car: 2 points) had good predictive accuracy in the validation cohort (area under the receiver operating characteristic curve 0.728; 95% CI 0.648-0.807). CONCLUSION: A risk score incorporating predictors for NPVTs may allow provocation of triggers to be performed in patients with greatest expected yield.

3.
J Interv Card Electrophysiol ; 67(3): 617-623, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37700118

RESUMO

BACKGROUND: There is growing interest in the possibility of discontinuing oral anticoagulation following successful catheter ablation of atrial fibrillation (AF). However, it remains unknown whether patients can accurately detect arrhythmia recurrences following ablation. We therefore sought to characterize the accuracy of pulse checking and arrhythmia symptoms for the identification of AF following ablation. METHODS: This prospective cohort study included patients at the Hospital of the University of Pennsylvania with an insertable cardiac monitor (ICM) treated with catheter ablation for AF who recorded the results from minimum twice daily pulse checks and additionally with arrhythmia symptoms into a diary for 2 months following their procedure. Accuracy of this self-assessment protocol was determined by comparison to ICM-detected AF. RESULTS: A total of 55 patients (age 69 ± 8 years, 30 (55%) male, CHA2DS2VASc score 3.2 ± 1. 5) were included. Patients recorded a total of 5911 pulse checks, and there were 280 episodes of ICM-documented AF among 26 patients with an average duration of 2.5 ± 3.3 h. Among 362 episodes of patient-suspected AF, 134 correlated with ICM-identified AF (37% true positive rate). Of the 5549 pulse checks that did not identify AF, 196 correlated with ICM-identified AF (4% false negative rate). Twice daily pulse checking had a sensitivity of 47% and a specificity of 96% for identifying each episode of AF. CONCLUSIONS: Our data indicate that a strategy of pulse checks and symptom assessment is insufficient to identify all episodes of AF in many patients following catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Ablação por Cateter/métodos
4.
J Interv Card Electrophysiol ; 67(3): 559-569, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37592198

RESUMO

BACKGROUND: The use of a multi-electrode Optrell mapping catheter during ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation procedures has not been widely reported. OBJECTIVES: We aim to describe the feasibility and safety of using the Optrell multipolar mapping catheter (MPMC) to guide catheter ablation of VT and PVCs. METHODS: We conducted a single-center, retrospective evaluation of patients who underwent VT or PVC ablation between June and November 2022 utilizing the MPMC. RESULTS: A total of 20 patients met the inclusion criteria (13 VT and 7 PVC ablations, 80% male, 61 ± 15 years). High-density mapping was performed in the VT procedures with median 2753 points [IQR 1471-17,024] collected in the endocardium and 12,830 points [IQR 2319-30,010] in the epicardium. Operators noted challenges in manipulation of the MPMC in trabeculated endocardial regions or near valve apparatus. Late potentials (LPs) were detected in 11 cases, 7 of which had evidence of isochronal crowding demonstrated during late annotation mapping. Two patients who also underwent entrainment mapping had critical circuitry confirmed in regions of isochronal crowding. In the PVC group, high-density voltage and activation mapping was performed with a median 1058 points [IQR 534-3582] collected in the endocardium. CONCLUSIONS: This novel MPMC can be used safely and effectively to create high-density maps in LV endocardium or epicardium. Limitations of the catheter include a longer wait time for matrix formation prior to starting point collection and challenges in manipulation in certain regions.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Masculino , Feminino , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Eletrodos , Catéteres , Ablação por Cateter/métodos
5.
JACC Clin Electrophysiol ; 9(11): 2275-2287, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37737775

RESUMO

BACKGROUND: Targeting nonpulmonary vein triggers (NPVTs) of atrial fibrillation (AF) after pulmonary vein isolation can be challenging. NPVTs are often single ectopic beats with a surface P-wave obscured by a QRS or T-wave. OBJECTIVES: The goal of this study was to construct an algorithm to regionalize the site of origin of NPVTs using only intracardiac bipolar electrograms from 2 linear decapolar catheters positioned in the posterolateral right atrium (along the crista terminalis with the distal bipole pair in the superior vena cava) and in the proximal coronary sinus (CS). METHODS: After pulmonary vein isolation in 42 patients with AF, pacing from 15 typical anatomic NPVT sites was conducted. For each pacing site, the electrogram activation sequence was analyzed from the CS catheter (simultaneous/chevron/inverse chevron/distal-proximal/proximal-distal) and activation time (ie, CSCTAT) between the earliest electrograms from the 2 decapolar catheters was measured referencing the earliest CS electrogram; a negative CSCTAT value indicates the crista terminalis catheter electrogram was earlier, and a positive CSCTAT value indicates the CS catheter electrogram was earlier. A regionalization algorithm with high predictive value was defined and tested in a validation cohort with AF NPVTs localized with electroanatomic mapping. RESULTS: In the study patient cohort (71% male; 43% with persistent AF, 52% with left atrial dilation), the algorithm grouped with high precision (positive predictive value 81%-99%, specificity 94%-100%, and sensitivity 30%-94%) the 15 distinct pacing sites into 9 clinically useful regions. Algorithm testing in a 98 patient validation cohort showed predictive accuracy of 91%. CONCLUSIONS: An algorithm defined by the activation sequence and timing of electrograms from 2 linear multipolar catheters provided accurate regionalization of AF NPVTs to guide focused detailed mapping.


Assuntos
Fibrilação Atrial , Veia Cava Superior , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Catéteres , Algoritmos
6.
JACC Clin Electrophysiol ; 9(12): 2523-2533, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37715743

RESUMO

BACKGROUND: Entrainment and pace mapping are used to identify critical components (CCs) of ventricular tachycardia (VT) circuits. In patients with dense myocardial scarring, VT circuits may elude capture at standard high pacing outputs (up to 10 mA at a 2-millisecond pulse width). OBJECTIVES: The purpose of this study was to assess the utility of very high-output pacing (V-HOP, 50 mA at 2 milliseconds) for identifying CCs of VT circuits after standard high pacing output failed to elicit capture in densely scarred myocardial tissue. METHODS: Our standard VT ablation approach included electroanatomic mapping for substrate characterization and entrainment and/or pace mapping to identify CCs of VT circuits. Patients that required V-HOP to capture sites of interest comprised the study cohort. Ablation endpoints were VT termination and noninducibility. RESULTS: Twenty-five patients (71 ± 10 years of age, all males) undergoing 26 VT ablations met the inclusion criteria. The mean left ventricular ejection fraction was 30% ± 14%, and 85% had ischemic cardiomyopathy. V-HOP was used to successfully entrain VT in 17 patients, yielding central isthmus sites in 10 and entrance/exit sites in 4. VT terminated with radiofrequency ablation at these sites in 15 patients. In 9 patients, V-HOP identified scar locations with a delayed exit. Acute procedural success was achieved in 24 patients without any adverse events. Over a follow-up period of 16 ± 21 months, 2 patients experienced VT recurrence requiring repeat ablation during which the same location was targeted successfully in 1 patient. CONCLUSIONS: In VT patients with a dense scar that is traditionally inexcitable, V-HOP can identify CCs of the re-entrant circuit and guide successful ablation.


Assuntos
Isquemia Miocárdica , Taquicardia Ventricular , Masculino , Humanos , Cicatriz , Volume Sistólico , Função Ventricular Esquerda , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
7.
JACC Clin Electrophysiol ; 9(9): 1903-1913, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37480866

RESUMO

BACKGROUND: Intraprocedural identification of intramural septal substrate for ventricular tachycardia (ISS-VT) in nonischemic cardiomyopathy (NICM) is challenging. Delayed (>40 ms) transmural conduction time (DCT) with right ventricular basal septal pacing has been previously shown to identify ISS-VT. OBJECTIVES: This study sought to determine whether substrate catheter ablation incorporating areas of DCT may improve acute and long-term outcomes. METHODS: We included patients with NICM and ISS-VT referred for catheter ablation between 2016 and 2020. ISS-VT was defined by the following: 1) confluent septal areas of low unipolar voltage (<8.3 mV) in the presence of normal or minimal bipolar abnormalities; and 2) presence of abnormal electrograms in the septum. Substrate ablation was guided by the following: 1) activation and/or entrainment mapping for tolerated VT and pace mapping with ablation of abnormal septal electrograms for unmappable VTs (n = 57, Group 1); and 2) empirically extended to target areas of DCT during right ventricular basal septal pacing regardless of their participation in inducible VT(s) but sparing the conduction system when possible (n = 24, Group 2). RESULTS: There were no significant baseline differences between Groups 1 and 2. Noninducibility of any VT programmed stimulation at the end of ablation was higher in Group 2 compared with Group 1 (80% vs 53%; P = 0.03). At 12-month follow-up, single-procedure VT-free survival was significantly higher (79% vs 46%; P = 0.006) and the time to VT recurrence was longer (mean 10 ± 3 months vs 7 ± 4 months; P = 0.02) in Group 2 compared with Group 1. CONCLUSIONS: In patients with NICM and ISS-VT, a substrate ablation strategy that incorporates areas of DCT appears to improve freedom from recurrent VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Doença do Sistema de Condução Cardíaco , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração
8.
JACC Clin Electrophysiol ; 9(2): 161-169, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36858681

RESUMO

BACKGROUND: Neuromodulation is increasingly recognized as a therapeutic strategy for patients with refractory ventricular arrhythmias (VAs). Percutaneous stellate ganglion blockade (SGB), transcutaneous magnetic stimulation (TcMS), and surgical cardiac sympathetic denervation (CSD) have all been utilized in this setting. OBJECTIVES: This study sought to characterize contemporary use and outcomes of these neuromodulation techniques for patients with refractory VA. METHODS: This retrospective cohort study included all patients at the Hospital of the University of Pennsylvania with antiarrhythmic drug (AAD)-refractory VA from 2019 to 2021 who were treated with SGB, TcMS, or CSD. RESULTS: A total of 34 patients (age 61 ± 14 years, 15 polymorphic VAs [44%], refractory to 1.8 ± 0.8 AADs) met inclusion criteria. SGB was performed on 11 patients (32%), TcMS on 19 (56%), and CSD on 7 (21%). Neuromodulation was associated with a reduction in the number of episodes of sustained VAs from 7 [IQR: 4-12] episodes in the 24 hours before the initial neuromodulation strategy to 0 [IQR: 0-1] episodes in the subsequent 24 hours (P < 0.001). During 1.2 ± 1.1 years of follow-up, 21 (62%) experienced recurrent VAs, and among those patients, the median time to recurrence was 3 [IQR: 1-25] days. Outcomes were similar among patients with monomorphic and polymorphic VAs. Among patients who had an acute myocardial infarction within 30 days before neuromodulation, the burden of VAs decreased from 11 [IQR: 7-12] episodes to 0 episodes in the 24 hours after treatment. CONCLUSIONS: Autonomic neuromodulation with SGB, TcMS, or CSD in patients with AAD-refractory VAs is safe and results in substantial acute reduction of VA although recurrent arrhythmias are common, and not all patients experience a reduction in arrhythmia burden.


Assuntos
Arritmias Cardíacas , Bloqueio Nervoso Autônomo , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Coração , Antiarrítmicos
9.
Heart Rhythm ; 20(6): 844-852, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36958413

RESUMO

BACKGROUND: Ventricular fibrillation (VF) can be initiated by ventricular premature depolarizations (VPDs) in the absence of obvious structural abnormalities. OBJECTIVE: The purpose of this study was to determine the prevalence of 12-lead electrocardiographic (ECG) sinus rhythm reduced QRS amplitude, QRS fractionation (QRSf), and early repolarization (ER) pattern, and the outcome of catheter ablation and VPD anatomic distribution in patients with VPDs initiating VF. METHODS: We compared a cohort with no apparent structural heart disease and VPDs initiating VF (group 1; n = 42) to a reference cohort (group 2; n = 61) of patients with no structural heart disease and symptomatic unifocal VPDs. RESULTS: A reduced QRS amplitude (<0.55 mV) in aVF (59% vs 10%; P <.001), QRSf in ≥2 contiguous leads (50% vs 16%; P <.001), and ER pattern (21.4% vs 1.6%; P = .01) were more common in group 1 than in group 2. At least 1 abnormal ECG finding was present in 34 group 1 patients (81%) vs 17 group 2 patients (28%) (P <.001). VPD origin included right ventricular and left ventricular distal Purkinje system and moderator band/papillary muscles in 83% of group 1 patients vs 18% of group 2 patients (P <.001). VF was eliminated with a single ablation procedure in 77% of group 1 patients with at least 2 years of follow-up. CONCLUSION: A reduced QRS amplitude (<0.55 mV) in aVF, QRSf in ≥2 contiguous leads, and/or an ER pattern are frequently observed in patients with VPDs initiating VF. VPDs initiating VF typically originate from the distal Purkinje system and papillary muscles and can be successfully eliminated with catheter ablation.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Ventricular , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Eletrocardiografia , Ventrículos do Coração , Músculos Papilares
10.
Card Electrophysiol Clin ; 15(1): 39-47, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36774135

RESUMO

Left ventricular outflow tract arrhythmias that fail endocardial mapping and ablation have traditionally been labeled as originating from the epicardial left ventricular summit. Although these sometimes can be targeted from the epicardial surface of the left ventricular ostium, such approach poses significant technical challenges. A significant proportion of such arrhythmias, however, exhibit intramyocardial origin, demonstrated by mapping intraseptal branches of the anterior interventricular vein, and henceforth defined as the basal superior intraseptal space.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Arritmias Cardíacas , Ventrículos do Coração , Endocárdio/cirurgia , Eletrocardiografia , Resultado do Tratamento
11.
JACC Clin Electrophysiol ; 8(12): 1515-1520, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36543501

RESUMO

BACKGROUND: Guidelines recommend that initial trial of a "pill-in-the-pocket" (PIP) Class 1C antiarrhythmic drug (AAD) for cardioversion of atrial fibrillation (AF) be performed in a monitored setting because of the potential for adverse reactions. OBJECTIVES: This study sought to characterize real-world, contemporary use of the PIP approach, including the setting of initiation and incidence of adverse events. METHODS: This retrospective cohort study included all patients at the Hospital of the University of Pennsylvania treated with a PIP approach for AF between 2007 and 2020. RESULTS: A total of 273 patients (age 56 ± 13 years; 182 [67%] male; CHA2DS2VASc score 1.1 ± 1.2) took a first dose of PIP AAD. Flecainide was used in 151 (55%) and propafenone in 122 (45%). The first dose of PIP AAD was taken in a monitored setting in 167 (62%). Significant adverse events occurred in 7 patients (3%), 2 of whom had taken the dose in a monitored setting. Significant adverse events included unexplained syncope (1 of 7), symptomatic bradycardia/hypotension (4 of 7), and 1:1 atrial flutter (2 of 7). All occurred in patients taking 300 mg of flecainide (n = 4) or 600 mg of propafenone (n = 3). Electrical cardioversion was performed in 29 (11%) patients because of failure of the AAD to terminate AF. One patient required intravenous fluids and vasopressors for 2 hours because of persistent hypotension and bradycardia. Two patients required permanent pacemakers for bradycardia. The remaining patients required no intervention. CONCLUSIONS: Our data support the current recommendation to initiate PIP AAD in a monitored setting because of rare significant adverse reactions that can require urgent intervention.


Assuntos
Fibrilação Atrial , Hipotensão , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Antiarrítmicos/efeitos adversos , Propafenona/efeitos adversos , Flecainida/efeitos adversos , Bradicardia , Estudos Retrospectivos
12.
Heart Rhythm ; 19(9): 1475-1483, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35278700

RESUMO

BACKGROUND: The intramyocardial aspect of the left ventricular summit (LVS) can be mapped by advancing a unipolar guidewire into septal perforator branches of the anterior interventricular vein. OBJECTIVE: The purpose of this study was to differentiate between ventricular premature depolarizations (VPDs) with a basal superior intraseptal (SIS) site of origin and those originating from the epicardial LVS using septal intramyocardial mapping. METHODS: A retrospective cohort of patients with suspected LVS VPDs who underwent SIS unipolar mapping were reviewed for their clinical characteristics, mapping findings, and procedural outcomes. RESULTS: SIS mapping was successful in 44 of 47 cases (93.6%). VPD origin was SIS (defined as earliest activation from the intraseptal wire) in 20 patients (45.5%; median 23 ms pre-QRS). Procedure success was similar in patients with (group 1) and without (group 2) SIS origin (84% vs 87.5%, respectively; P = .842). Of the 10 patients in group 1 without presystolic endocardial activation, 5 (11.3% of all 44 cases) were successfully ablated from the left ventricular endocardium by using an anatomical approach targeting the endocardium closest to the earliest intraseptal activation site. CONCLUSION: A significant proportion (45.5%) of VPDs that appear to arise from the left ventricular summit can be demonstrated to have a SIS origin using septal perforator venous mapping. A significant minority (11.3%) of these can be ablated from the endocardium by targeting from an anatomic vantage point closest to the earliest intraseptal activation site. The described strategy may help differentiate true LVS VPDs from those with SIS sites of origin.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Ablação por Cateter/métodos , Eletrocardiografia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
13.
Heart Rhythm ; 19(2): 187-194, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34601127

RESUMO

BACKGROUND: Ventricular tachycardia (VT) substrate in left ventricular (LV) nonischemic cardiomyopathy (NICM) consists of fibrosis with surviving myocardium. OBJECTIVE: The purpose of this study was to determine whether, in patients with LV NICM and sustained VT, reduced QRS amplitude and QRSf during sinus rhythm can identify the presence and location of abnormal septal (S-NICM) and/or free-wall (FW-NICM) VT substrate. METHODS: We compared patients with NICM and VT (group 1) with electroanatomic mapping septal (S-NICM; n = 21) or free-wall (FW-NICM; n = 20) VT substrate to a 38-patient reference cohort (group 2) with cardiac magnetic resonance imaging (cMRI) and NICM but no VT referred for primary prevention implantable cardioverter-defibrillator (26 [68.4%] with late gadolinium enhancement). RESULTS: Group 1 had lower QRS amplitude in leads II (0.60 ± 0.22 vs 0.86 ± 0.35, P <.001), aVR (0.60 ± 0.24 vs 0.75 ± 0.31, P = .002), aVF (0.48 ± 0.20 vs 0.70 ± 0.28, P <.001), and V2 (1.09 ± 0.52 vs 1.38 ± 0.55, P = .001) than group 2. QRS <0.55 mV in lead aVF identified VT and accompanying substrate with sensitivity 70% and specificity 71%. Most group 1 and group 2 patients had 12-lead ECG QRS fractionation (QRSf) in ≥2 contiguous leads (78% vs 63.2%, P = .14). Sensitivity and specificity for ≥2 QRSf leads identifying respective regional electroanatomic or cMRI abnormalities were 76% and 50% for inferior, 44% and 87% for lateral, and 21% and 89% for anterior leads. CONCLUSION: In LV NICM, low frontal plane QRS (<0.55 mV in aVF) is associated with VT substrate. Although multilead QRS fractionation is associated with the presence and location of VT substrate, it is frequently identified in patients without VT with cMRI abnormalities.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Imagem Cinética por Ressonância Magnética , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Meios de Contraste , Eletrocardiografia , Mapeamento Epicárdico , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
14.
Circulation ; 144(20): 1590-1597, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34780252

RESUMO

BACKGROUND: Prescription opioids are a major contributor to the ongoing epidemic of persistent opioid use (POU). The incidence of POU among opioid-naïve patients after cardiac implantable electronic device (CIED) procedures is unknown. METHODS: This retrospective cohort study used data from a national administrative claims database from 2004 to 2018 of patients undergoing CIED procedures. Adult patients were included if they were opioid-naïve during the 180-day period before the procedure and did not undergo another procedure with anesthesia in the next 180 days. POU was defined by filling an additional opioid prescription >30 days after the CIED procedure. RESULTS: Of the 143 400 patients who met the inclusion criteria, 15 316 (11%) filled an opioid prescription within 14 days of surgery. Among these patients, POU occurred in 1901 (12.4%) patients 30 to 180 days after surgery. The likelihood of developing POU was increased for patients who had a history of drug abuse (odds ratio, 1.52; P=0.005), preoperative muscle relaxant (odds ratio, 1.52; P<0.001) or benzodiazepine (odds ratio, 1.23; P=0.001) use, or opioid use in the previous 5 years (OR, 1.76; P<0.0001). POU did not differ after subcutaneous implantable cardioverter defibrillator or other CIED procedures (11.1 versus 12.4%; P=0.5). In a sensitivity analysis excluding high-risk patients who were discharged to a facility or who had a history of drug abuse or previous opioid, benzodiazepine, or muscle relaxant use, 8.9% of the remaining cohort had POU. Patients prescribed >135 mg of oral morphine equivalents had a significantly increased risk of POU. CONCLUSIONS: POU is common after CIED procedures, and 12% of patients continued to use opioids >30 days after surgery. Higher initially prescribed oral morphine equivalent doses were associated with developing POU.


Assuntos
Analgésicos Opioides/uso terapêutico , Desfibriladores Implantáveis , Cuidados Pós-Operatórios , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Tomada de Decisão Clínica , Bases de Dados Factuais , Gerenciamento Clínico , Prescrições de Medicamentos/normas , Prescrições de Medicamentos/estatística & dados numéricos , Duração da Terapia , Pesquisas sobre Atenção à Saúde , Humanos , Vigilância em Saúde Pública
17.
JACC Case Rep ; 3(1): 136-140, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34317487

RESUMO

Transseptal access for atrial fibrillation ablation can be challenging in the presence of iatrogenically modified interatrial septum. We report the first described transseptal left atrial access for atrial fibrillation ablation in the presence of an investigational interatrial shunt device, performed in a patient with heart failure with preserved ejection fraction. (Level of Difficulty: Intermediate.).

20.
J Cardiovasc Electrophysiol ; 31(6): 1379-1384, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32243641

RESUMO

INTRODUCTION: Acute hemopericardium during cardiac electrophysiology (EP) procedures may result in significant blood loss and is the most common cause of procedure-related death. Matched allogeneic blood is often not immediately available. The feasibility and safety of direct autotransfusion in cardiac electrophysiology patients requiring emergency pericardiocentesis is unknown. METHODS: We retrospectively analyzed records of patients undergoing EP procedures at a single, tertiary care medical center who had procedure-related acute hemopericardium requiring emergency pericardiocentesis during a 3-year period. Procedure details, transfusion volumes, and clinical outcomes of patients who received direct autotransfusion of aspirated pericardial blood via a femoral venous sheath were compared to those of patients who did not receive direct autotransfusion. RESULTS: During the study period, 10 patients received direct autotransfusion (group 1) and outcomes were compared with those of 14 control patients who did not receive direct autotransfusion (group 2). The volume of aspirated pericardial blood was similar in groups 1 and 2 (1.6 ± 0.7 L vs 1.3 ± 1.0 L, respectively; P = .52). Amongst patients with aspirated volumes <1 L, group 1 patients (n = 4) were less likely than group 2 patients (n = 8) to require allotransfusion (0% vs 75%, P = .02). Amongst patients with aspirated volume ≥1 L, group 1 patients (n = 6) required fewer units of red cell allotransfusion than group 2 patients (n = 6) (1.5 ± 0.8 units vs 4.3 ± 2.0 units, P = .01). No procedural complications related to direct autotransfusion occurred. CONCLUSIONS: Direct autotransfusion following emergency pericardiocentesis during electrophysiology procedures requiring systemic anticoagulation is feasible and safe. The utilization of direct autotransfusion may eliminate or reduce the need for allotransfusion.


Assuntos
Transfusão de Sangue Autóloga , Tamponamento Cardíaco/terapia , Ablação por Cateter/efeitos adversos , Derrame Pericárdico/terapia , Pericardiocentese , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Transfusão de Sangue Autóloga/efeitos adversos , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Emergências , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/etiologia , Pericardiocentese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS