Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 13(6): 7784-7791, 2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33533611

RESUMO

Recently, flexible neuromorphic devices have attracted extensive attention for the construction of perception cognitive systems with the ultimate objective to achieve robust computation, efficient learning, and adaptability to evolutionary changes. In particular, the design of flexible neuromorphic devices with data processing and arithmetic capabilities is highly desirable for wearable cognitive platforms. Here, an albumen-based protein-gated flexible indium tin oxide (ITO) ionotronic neuromorphic transistor was proposed. First, the transistor demonstrates excellent mechanical robustness against bending stress. Moreover, spike-duration-dependent synaptic plasticity and spike-amplitude-dependent synaptic plasticity behaviors are not affected by bending stress. With the unique protonic gating behaviors, neurotransmission processes in biological synapses are emulated, exhibiting three characteristics in neurotransmitter release, including quantal release, stochastic release, and excitatory or inhibitory release. In addition, three types of spike-timing-dependent plasticity learning rules are mimicked on the ITO ionotronic neuromorphic transistor. Most interestingly, algebraic arithmetic operations, including addition, subtraction, multiplication, and division, are implemented on the protein gated neuromorphic transistor for the first time. The present work would open a promising biorealistic avenue to the scientific community to control and design wearable "green" cognitive platforms, with potential applications including but not limited to intelligent humanoid robots and replacement neuroprosthetics.


Assuntos
Albuminas/química , Neurotransmissores/química , Óxidos/química , Compostos de Estanho/química , Plasticidade Neuronal , Tamanho da Partícula , Propriedades de Superfície , Transistores Eletrônicos
2.
Int J Nanomedicine ; 15: 3597-3603, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32547016

RESUMO

BACKGROUND: Transparent thin-film transistors (TFTs) have received a great deal of attention for medical sensors, OLED and medical display applications. Moreover, ultrathin nanomaterial layers are favored due to their more compact design architectures. METHODS: Here, transparent TFTs are proposed and were investigated under different stress conditions such as temperature and biases. RESULTS: Key electrical characteristics of the sensors, such as threshold voltage changes, illustrate their linear dependence on temperature with a suitable recovery, suggesting the potential of the devices to serve as medical temperature sensors. The temperature conditions changed in the range of 28°C to 40°C, which is within the standard human temperature testing range. The thickness of the indium-gallium-zinc oxide semiconductor layer was as thin as only 5-6 nm, deposited by mature radio-frequency sputtering which also showed good repeatability. Optimal bending durability caused by mechanical deformation was demonstrated via suitable electrical properties after up to 600 bending cycles, and by testing the flexible device at a different bending radii ranging from 48 mm to 18 mm. CONCLUSION: In summary, this study suggests that the present transparent nano TFTs are promising candidates for medical sensors, OLED and displays which require transparency and stability.


Assuntos
Nanoestruturas/química , Nanotecnologia/métodos , Fenômenos Ópticos , Transistores Eletrônicos , Reprodutibilidade dos Testes , Temperatura
3.
Andrology ; 8(5): 1086-1094, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32087037

RESUMO

OBJECTIVES: The aim of the study was to investigate the ability of the blood lipid parameters to predict the discrimination of arteriogenic erectile dysfunction (ED). MATERIALS AND METHODS: 260 subjects with ED and 60 healthy controls were enrolled. Eight lipid parameters, including total cholesterol (TC), triglycerides (TG), LDL-C, HDL-C, non-HDL-C, TC/HDL ratio, TG/HDL ratio, and LDL/HDL ratio, together with other plasma biomarkers like sex hormones were measured in all participants. Nocturnal penile tumescence (NPT), penile color Doppler ultrasonography (pDUS), and neurophysiological tests were conducted in the ED group. RESULTS: Forty-four ED patients with normal NPT, and 84 with normal vasculature or mixed vascular abnormalities were excluded. The remaining 132 men were classified into two groups, arteriogenic ED (n = 87) and venous leakage (n = 45), by pDUS. TC/HDL, LDL/HDL, and LDL-C were significantly higher (P < .05) and HDL-C was significantly lower (P < .05) in the arteriogenic ED group when compared with the venous and the control groups. Receiver operating characteristic curve analysis identified area under the curve values that were predictive of arteriogenic ED for: TC/HDL and LDL/HDL 0.720 and 0.737, TC/HDL ≥ 3.73 and LDL/HDL ≥ 2.01 (sensitivity: 56.3%; specificity: 83.3% vs sensitivity: 55.2%; specificity: 91.7%), HDL-C (0.791), ≤1.25 mmol/L (sensitivity: 69%; specificity: 81.7%), LDL-C (0.641), ≥2.41 mmol/L (sensitivity: 55.2%; specificity: 76.7%).In the arteriogenic ED group, a significant inverse correlation was detected between TC/HDL, LDL/HDL, LDL-C and 10-minutes peak systolic velocity (PSV) (All P < .01)and a significant positive correlation was recognized between HDL-C and 10-minutes PSV(P < .01). Multivariate step wise linear regression indicated lipid parameters of LDL/HDL and HDL-C were significantly associated with 10-MinPSV (P < .01). CONCLUSION: These findings suggest the LDL/HDL and HDL-C might be a powerful indicator to predict and diagnose arteriogenic ED, and lipid-lowing therapy should be considered for these patients.


Assuntos
Impotência Vasculogênica/sangue , Lipídeos/sangue , Adulto , Biomarcadores/sangue , Humanos , Impotência Vasculogênica/diagnóstico , Impotência Vasculogênica/diagnóstico por imagem , Masculino , Ereção Peniana , Valor Preditivo dos Testes , Estudos Prospectivos , Ultrassonografia Doppler em Cores
4.
Asian J Androl ; 22(5): 507-512, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31898586

RESUMO

This study aimed to describe endoscopic anatomy of the seminal tract and summarize our experience of transutricular seminal vesiculoscopy (TSV) guided by real-time transrectal ultrasonography (TRUS) in managing persistent hematospermia. A total of 281 consecutive patients with persistent hematospermia who underwent TSV with or without real-time TRUS were enrolled in this single-center, prospective, observational study. The median follow-up period was 36.5 (range: 8.0-97.5) months. TSV was successfully performed in 272 (96.8%) patients. The approach of a 4.5/6 F rigid vesiculoscope entering the seminal tract was categorized into four types on the basis of endoscopic presentation of the ejaculatory duct orifice and verumontanum. Seven (2.6%), 74 (27.2%), 64 (23.5%), and 127 (46.7%) patients had Types I (through the ejaculatory duct in the urethra), II (through the ejaculatory duct in the prostatic utricle), III (transutricular fenestration through a thin membrane), and IV (real-time transrectal ultrasound-guided transutricular fenestration) approach, respectively. In patients who successfully underwent surgery, bleeding occurred in the seminal vesicle in 249 (91.5%) patients. Seminal vesiculitis, calculus in the prostatic utricle, calculus in the ejaculatory duct, calculus in the seminal vesicle, prostatic utricle cysts, and seminal vesicle cysts were observed in 213 (78.3%), 96 (35.3%), 22 (8.1%), 81 (29.8%), 25 (9.2%), and 11 (4.0%) patients, respectively. Hematospermia was alleviated or disappeared in 244 (89.7%) patients 12 months after surgery. Fifteen patients had recurrent hematospermia, and the median time to recurrence was 7.5 (range: 2.0-18.5) months. TSV guided by TRUS may contribute to successful postoperative outcomes in managing persistent hematospermia.


Assuntos
Endoscopia/métodos , Hemospermia/cirurgia , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Cálculos/complicações , Cálculos/cirurgia , Doença Crônica , Cistos/complicações , Cistos/cirurgia , Endoscopia/efeitos adversos , Endoscopia/instrumentação , Seguimentos , Hemospermia/diagnóstico por imagem , Hemospermia/etiologia , Humanos , Inflamação/complicações , Inflamação/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Glândulas Seminais/diagnóstico por imagem , Ultrassonografia de Intervenção/efeitos adversos , Adulto Jovem
5.
ACS Appl Mater Interfaces ; 11(31): 28352-28358, 2019 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-31291719

RESUMO

Neuromorphic devices and systems with ultralow power consumption are important in building artificial intelligent systems. Here, indium tin oxide (ITO)-based oxide neuromorphic transistors are fabricated using poly(vinyl alcohol) (PVA)-based proton-conducting electrolytes as gate dielectrics. The electrical performances of the transistors can be modulated with the ITO channel thickness. Fundamental synaptic functions, including excitatory postsynaptic current, paired-pulse facilitation, and multistore memory, are successfully emulated. Most importantly, the PVA-gated neuromorphic devices demonstrate ultralow energy consumption of ∼1.16 fJ with ultrahigh sensitivity of ∼5.4 dB, as is very important for neuromorphic engineering applications. Because of the inherent environmental-friendly characteristics of PVA, the devices possess security biocompatibility. Thus, the proposed PVA-gated oxide neuromorphic transistors may find potential applications in "green" ultrasensitive neuromorphic systems and efficient electronic biological interfaces.

6.
Asian J Androl ; 2018 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-30198496

RESUMO

The aim of our study was to investigate the role of platelet parameters including mean platelet volume (MPV) and platelet count (PC) in the pathogenesis of penile arteriogenic erectile dysfunction (ED) and to evaluate the association between the platelet parameters and arteriogenic ED. There were 244 patients with ED (based on the International Index of Erectile Function [IIEF]-5 ≤21) and 60 healthy controls (IIEF-5 >21) enrolled. All participants were asked to undergo a laboratory examination, and penile vascular function was evaluated using penile color Doppler ultrasonography (pDUS). Among these ED patients, 24 patients with no abnormality on nocturnal penile tumescence (NPT) and 84 with normal vasculature or mixed vascular abnormalities were excluded. The other patients were classified into three groups as follows: control (n = 60), arteriogenic ED (n = 99), and venous leakage (n = 37) groups. MPV and PC were significantly higher in the arteriogenic ED group compared with the venous and control groups (P < 0.05). Receiver operating characteristic curve analysis revealed that the area under the curve for MPV to predict arteriogenic ED was 0.707. MPV ≥9.65 fl was recognized as a cut-off value for potential arteriogenic ED (sensitivity: 47.5%; specificity: 91.7%). A significant inverse correlation was detected between MPV and 10-min peak systolic velocity (PSV) (r = -0.34; P < 0.001) in the arteriogenic ED group. These findings suggest that the MPV might be a powerful indicator to predict and diagnose arteriogenic ED, and MPV may be a marker for ED when using pDUS.

7.
ACS Appl Mater Interfaces ; 9(42): 37064-37069, 2017 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-28975791

RESUMO

Ion coupling has provided an additional method to modulate electric properties for solid-state materials. Here, phosphorosilicate glass (PSG)-based electrolyte gated protonic/electronic coupled indium-tin-oxide electric-double-layer (EDL) transistors are fabricated. The oxide transistor exhibits good electrical performances due to an extremely strong proton gating behavior for the electrolyte. With interfacial electrochemical doping, channel conductances of the oxide EDL transistor can be regulated to different levels, corresponding to different initial synaptic weights. Thus, activity dependent synaptic responses such as excitatory postsynaptic current, paired-pulse facilitation, and high-pass filtering are discussed in detail. The proposed proton conductor gated oxide EDL synaptic transistors with activity dependent synaptic plasticities may act as fundamental building blocks for neuromorphic system applications.

8.
Asian J Androl ; 19(2): 214-218, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27678469

RESUMO

The aim of this study is to evaluate the benefits of laparoscopic Doppler ultrasound (LDU) application during laparoscopic varicocelectomy (LV), and to compare the surgical outcomes and complications between LDU-assisted LV (LDU-LV) and conventional LV for infertile patients with varicoceles; 147 infertile patients were randomly divided into two groups. Operative and postoperative parameters, semen parameters, and the pregnancy rate were compared. There were no differences in baseline demographics. The operative time was significantly longer in LDU-LV group than LV group. The incidence of postoperative hydrocele was 1.4% (1/72) in LDU-LV group versus 10.7% (8/75) in LV group, which showed a significant difference (P < 0.05). However, other surgical outcomes, such as postoperative hospital stay, postoperative recurrence, and testicular atrophy, were similar between the two groups. Sperm concentration and sperm motility were significantly increased in both groups at 3, 6, and 12 months after surgery (P < 0.01), and they were higher in LDU-LV than LV group in 12 months after surgery (34.21 ± 6.36 vs 29.99 ± 6.04 for concentration, P < 0.05; 40.72 ± 8.12 vs 37.31 ± 6.12 for motility, P < 0.05). Sperm morphology was comparable between the two groups. The pregnancy rate showed no significant difference (44.4% of the LDU-LV vs 37.3% of the LV, P > 0.05). In conclusion, compared with LV, LDU-LV could safely and effectively ligate all spermatic veins and preserve spermatic arteries without leading to high varicocele recurrence and postoperative hydrocele. Given the benefits that sperm counts as well as sperm motility favoring LDU-LV, we recommend that LDU should be routinely used as an effective tool to improve outcomes and safety of laparoscopic varicocelectomy.


Assuntos
Infertilidade Masculina/cirurgia , Cordão Espermático/cirurgia , Cirurgia Assistida por Computador/métodos , Ultrassonografia Doppler/métodos , Procedimentos Cirúrgicos Urológicos Masculinos/métodos , Varicocele/cirurgia , Adulto , Feminino , Humanos , Infertilidade Masculina/etiologia , Cuidados Intraoperatórios/métodos , Laparoscopia/métodos , Masculino , Microcirurgia , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Gravidez , Taxa de Gravidez , Análise do Sêmen , Contagem de Espermatozoides , Motilidade dos Espermatozoides , Cordão Espermático/diagnóstico por imagem , Hidrocele Testicular/epidemiologia , Varicocele/complicações , Varicocele/diagnóstico por imagem
9.
Nat Commun ; 5: 3158, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24452193

RESUMO

The basic units in our brain are neurons, and each neuron has more than 1,000 synapse connections. Synapse is the basic structure for information transfer in an ever-changing manner, and short-term plasticity allows synapses to perform critical computational functions in neural circuits. Therefore, the major challenge for the hardware implementation of neuromorphic computation is to develop artificial synapse network. Here in-plane lateral-coupled oxide-based artificial synapse network coupled by proton neurotransmitters are self-assembled on glass substrates at room-temperature. A strong lateral modulation is observed due to the proton-related electrical-double-layer effect. Short-term plasticity behaviours, including paired-pulse facilitation, dynamic filtering and spatiotemporally correlated signal processing are mimicked. Such laterally coupled oxide-based protonic/electronic hybrid artificial synapse network proposed here is interesting for building future neuromorphic systems.


Assuntos
Compostos Inorgânicos/química , Neurotransmissores/química , Prótons , Sinapses/fisiologia , Microscopia Eletrônica de Varredura , Dióxido de Silício/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA