Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
1.
EMBO J ; 43(12): 2397-2423, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38760575

RESUMO

The nucleoside analogue decitabine (or 5-aza-dC) is used to treat several haematological cancers. Upon its triphosphorylation and incorporation into DNA, 5-aza-dC induces covalent DNA methyltransferase 1 DNA-protein crosslinks (DNMT1-DPCs), leading to DNA hypomethylation. However, 5-aza-dC's clinical outcomes vary, and relapse is common. Using genome-scale CRISPR/Cas9 screens, we map factors determining 5-aza-dC sensitivity. Unexpectedly, we find that loss of the dCMP deaminase DCTD causes 5-aza-dC resistance, suggesting that 5-aza-dUMP generation is cytotoxic. Combining results from a subsequent genetic screen in DCTD-deficient cells with the identification of the DNMT1-DPC-proximal proteome, we uncover the ubiquitin and SUMO1 E3 ligase, TOPORS, as a new DPC repair factor. TOPORS is recruited to SUMOylated DNMT1-DPCs and promotes their degradation. Our study suggests that 5-aza-dC-induced DPCs cause cytotoxicity when DPC repair is compromised, while cytotoxicity in wild-type cells arises from perturbed nucleotide metabolism, potentially laying the foundations for future identification of predictive biomarkers for decitabine treatment.


Assuntos
DNA (Citosina-5-)-Metiltransferase 1 , Decitabina , Ubiquitina-Proteína Ligases , Decitabina/farmacologia , Humanos , DNA (Citosina-5-)-Metiltransferase 1/metabolismo , DNA (Citosina-5-)-Metiltransferase 1/genética , Ubiquitina-Proteína Ligases/metabolismo , Ubiquitina-Proteína Ligases/genética , Metilação de DNA/efeitos dos fármacos , Antimetabólitos Antineoplásicos/farmacologia , Animais , Sumoilação/efeitos dos fármacos
2.
Nat Cell Biol ; 26(5): 797-810, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38600235

RESUMO

Covalent DNA-protein cross-links (DPCs) are toxic DNA lesions that block replication and require repair by multiple pathways. Whether transcription blockage contributes to the toxicity of DPCs and how cells respond when RNA polymerases stall at DPCs is unknown. Here we find that DPC formation arrests transcription and induces ubiquitylation and degradation of RNA polymerase II. Using genetic screens and a method for the genome-wide mapping of DNA-protein adducts, DPC sequencing, we discover that Cockayne syndrome (CS) proteins CSB and CSA provide resistance to DPC-inducing agents by promoting DPC repair in actively transcribed genes. Consequently, CSB- or CSA-deficient cells fail to efficiently restart transcription after induction of DPCs. In contrast, nucleotide excision repair factors that act downstream of CSB and CSA at ultraviolet light-induced DNA lesions are dispensable. Our study describes a transcription-coupled DPC repair pathway and suggests that defects in this pathway may contribute to the unique neurological features of CS.


Assuntos
Síndrome de Cockayne , DNA Helicases , Enzimas Reparadoras do DNA , Reparo do DNA , Proteínas de Ligação a Poli-ADP-Ribose , RNA Polimerase II , Humanos , Síndrome de Cockayne/genética , Síndrome de Cockayne/metabolismo , Síndrome de Cockayne/patologia , Adutos de DNA/metabolismo , Adutos de DNA/genética , Dano ao DNA , DNA Helicases/metabolismo , DNA Helicases/genética , Enzimas Reparadoras do DNA/metabolismo , Enzimas Reparadoras do DNA/genética , Reparo por Excisão , Proteínas de Ligação a Poli-ADP-Ribose/metabolismo , Proteínas de Ligação a Poli-ADP-Ribose/genética , Receptores de Interleucina-17 , RNA Polimerase II/metabolismo , RNA Polimerase II/genética , Fatores de Transcrição , Transcrição Gênica , Ubiquitinação , Raios Ultravioleta
3.
Talanta ; 274: 126031, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574536

RESUMO

Real-time monitoring of nitrite and nitrate is crucial for maintaining soil health and promoting plant growth. In this study, a portable ion-chromatograph (IC, Aquamonitrix) analyser, coupled with a field-applicable ultrasonic-assisted extraction method, was utilised for in-field determination of nitrate and nitrite in soils. This is the first application of this type of analyser to soil nutrients. On-site analysis of soil from a local sports field showed 94.8 ± 4.3 µg g-1 nitrate, with LODs of 32.0 µg g-1 for nitrate and 5.4 µg g-1 for nitrite. The results were in close agreement with those obtained using a conventional lab-based IC. Relative standard deviations (%RSDs) for soil analysis using Aquamonitrix were consistently below 10%. The obtained average recoveries of samples spiked with nitrite were 100% and 104% for the portable IC and conventional IC, respectively. Furthermore, to assess the suitability of portable IC for samples with high organic matter content, various natural organic fertilisers were extracted and analysed. The results showed 16.2 ± 0.7 µg g-1 nitrite and 28.5 ± 5.6 µg g-1 nitrate in sheep manure samples with LODs of 2.0 µg g-1 for nitrite and 12.0 µg g-1 for nitrate. The portable IC system was further demonstrated via real-time on-site analysis of soil pore-water acquired using a portable battery-based ceramic pore-water sampler. A continuous increase in nitrate concentration over time was observed (from 80 to 148 µg mL-1) in the soil pore-water in a vegetable garden four days after heavy rain. Unlike conventionally sampled natural waters, 7-day storage of the studied pore water samples revealed no changes in nitrate concentrations. An average of 558 ± 51 µg mL-1 nitrate was detected in the soil pore-water samples analysed on a spinach farm, immediately after irrigation.

4.
Anal Chim Acta ; 1304: 342556, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38637040

RESUMO

BACKGROUND: The on-site and simultaneous determination of anionic nitrite (NO2-) and nitrate (NO3-), and cationic ammonium (NH4+), in industrial and natural waters, presents a significant analytical challenge. Toward this end, herein a 3D-printed micro-reactor with an integrated heater chip was designed and optimised for the post-column colorimetric detection of NH4+ using a modified Berthelot reaction. The system was integrated within a portable and field deployable ion chromatograph (Aquamonitrix) designed to separate and detect NO2- and NO3-, but here enabled with dual LED-based absorbance detectors, with the aim to provide the first system capable of simultaneous determination of both anions and NH4+ in industrial and natural waters. RESULTS: Incorporating a 0.750 mm I.D. 3D-printed serpentine-based microchannel for sample-reagent mixing and heating, the resultant micro-reactor had a total reactor channel length of 1.26 m, which provided for a reaction time of 1.42 min based upon a total flow rate of 0.27 mL min-1, within a 40 mm2 printed area. The colorimetric reaction was performed within the micro-reactor, which was then coupled to a dedicated 660 nm LED-based absorbance detector. By rapidly delivering a reactor temperature of 70 °C in just 40 s, the optimal conditions to improve reaction kinetics were achieved to provide for limits of detection of 0.1 mg L-1 for NH4+, based upon an injection volume of just 10 µL. Linearity for NH4+ was observed over the range 0-50 mg L-1, n = 3, R2 = 0.9987. The reactor was found to deliver excellent reproducibility when included as a post-column reactor within the Aquamonitrix analyser, with an overall relative standard deviation below 1.2 % for peak height and 0.3 % for peak residence time, based upon 6 repeat injections. SIGNIFICANCE: The printed post-column reactor assembly was integrated into a commercial portable ion chromatograph developed for the separation and detection of NO2- and NO3-, thus providing a fully automated system for the remote and simultaneous analysis of NO2-, NO3-, and NH4+ in natural and industrial waters. The fully automated system was deployed externally within a greenhouse facility to demonstrate this capability.

5.
J Gastrointest Cancer ; 55(2): 572-583, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38324136

RESUMO

PURPOSE: GISTs arising from organs outside GI tract are defined as extragastrointestinal GISTs (EGIST). The majority of EGISTs arise from small intestinal mesentry, mesocolon, omentum, retroperitoneum, abdominal wall, liver and pancreas with pancreas comprising less than 5% of it. Due to limited data, it is unknown if the results of GIST can be generalised for EGISTs. We thereby present the largest single-centre case series of primary pancreatic GIST so far with review of existing literature. METHODS: A total of 9 patients of primary pancreatic GIST were treated at our institute from September 2016 to February 2023. After literature search for all studies published before February 2023, 51 articles including 57 patients were identified. Their clinicopathological data and survival analysis were assessed. RESULTS: The median age of patients treated at our centre was 53 years with a female predominance. The most common epicentre was pancreatic head with abdominal pain as the most common presenting symptom. All 57 patients documented in literature belonged to a similar age group with similar gender predilection. The factors impacting DFS were histologic type, mitotic index, NIH risk category and adjuvant therapy. The median DFS was 74 months with a 5-year DFS being 71.9%, while the 5-year OS was 90.4%. CONCLUSION: Pancreatic GIST is a rare entity. Due to limited evidence and evolving literature, results cannot be generalised to a larger population. Larger case series with longer follow-up data are required to further understand the disease biology and long-term outcomes of pancreatic GIST.


Assuntos
Tumores do Estroma Gastrointestinal , Neoplasias Pancreáticas , Humanos , Tumores do Estroma Gastrointestinal/patologia , Tumores do Estroma Gastrointestinal/mortalidade , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/terapia , Feminino , Masculino , Idoso , Adulto
6.
Sci Adv ; 9(49): eadl2108, 2023 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-38055822

RESUMO

The catalytic cycle of topoisomerase 2 (TOP2) enzymes proceeds via a transient DNA double-strand break (DSB) intermediate termed the TOP2 cleavage complex (TOP2cc), in which the TOP2 protein is covalently bound to DNA. Anticancer agents such as etoposide operate by stabilizing TOP2ccs, ultimately generating genotoxic TOP2-DNA protein cross-links that require processing and repair. Here, we identify RAD54 like 2 (RAD54L2) as a factor promoting TOP2cc resolution. We demonstrate that RAD54L2 acts through a novel mechanism together with zinc finger protein associated with tyrosyl-DNA phosphodiesterase 2 (TDP2) and TOP2 (ZATT/ZNF451) and independent of TDP2. Our work suggests a model wherein RAD54L2 recognizes sumoylated TOP2 and, using its ATPase activity, promotes TOP2cc resolution and prevents DSB exposure. These findings suggest RAD54L2-mediated TOP2cc resolution as a potential mechanism for cancer therapy resistance and highlight RAD54L2 as an attractive candidate for drug discovery.


Assuntos
Adutos de DNA , Proteínas de Ligação a DNA , Humanos , Adutos de DNA/genética , Proteínas de Ligação a DNA/genética , Proteínas de Ligação a DNA/metabolismo , Diester Fosfórico Hidrolases/genética , DNA Topoisomerases Tipo II/genética , DNA/genética , Instabilidade Genômica , DNA Helicases/genética
7.
Anal Chim Acta ; 1280: 341847, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37858546

RESUMO

BACKGROUND: In capillary electrophoresis (CE), the inner surface of fused-silica capillaries is commonly covalently modified with liquid silanes to control electroosmotic flow (EOF). This liquid phase deposition (LPD) approach is challenging for long and narrow-diameter capillaries (≥1 m, ≤25 µm ID) inhibiting commercial production. Here, we use chemical vapour deposition (CVD) to covalently modify capillaries with different silanes. Using a home-built CVD device, capillaries were modified with neutral (3-glycidyloxypropyl) trimethoxysilane (GPTMS), the weak base (3-aminopropyl) trimethoxysilane (APTMS), the weak acid 3-mercaptopropyltrimethoxysilane (MPTMS) and the neutral hydrophobic trichloro(1H,1H,2H,2H-perfluorooctyl) silane (PFOCTS). Gas-phase modification of GPTMS with acid and ammonia allowed further modification of the surface prior to molecular layer deposition (MLD) of poly(p-phenylene terephthalamide) (PPTA) using the self-limiting sequential reaction between terephthalaldehyde (TA) and p-phenylenediamine (PD) vapours. RESULTS: Capillaries coated with GPTMS by CVD showed a greater reduction in EOF at all pH values than the conventional LPD. APTMS showed a reduction of the EOF at pH 9, with EOF reversal observed below pH 6. MPTMS provided a slightly lower EOF than an unmodified capillary at high pH, and a slightly higher EOF at lower pH. PFOCTS provided the most consistent EOF as a function of pH. The deposition of successive layers of PPTA resulted in increased surface coverage of the polymer and a greater reduction in EOF at pH higher than 5. The stability of a 10 µm ID GPTMS coated capillary was tested at pH 8.8 in a 200 mM CHES/Tris BGE for the separation of inorganic anions. Over 1.5 months of continuous operation (≈4130 runs), the reproducibility of the apparent mobilities for chloride, nitrite, nitrate and sulfate were 2.43%, 2.56%, 2.63% and 3.05%, respectively. The intra-day and inter-day column-to-column reproducibility and batch-to-batch reproducibility for all the coated capillaries ranged between 0.34% and 3.95%. SIGNIFICANCE: The study demonstrates the superior performance of CVD coating for suppressing the EOF compared to LPD allowing the easy modification of long lengths of narrow capillary. The variation in silane, and the ability of MLD to modify and control the surface chemistry, provides a simple and facile method for surface modification. The stability of these coatings will allow long-term capillary electrophoresis monitoring of water chemistry, such as for monitoring fertiliser run-off in natural waters.

8.
J Chromatogr A ; 1709: 464382, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37722175

RESUMO

A novel approach for multi-wavelength ultraviolet (UV) absorbance detection has been introduced employing a single board computer (SBC) with a field programmable gate array (FPGA), Red Pitaya SBC, to generate separated micro pulses for three deep-ultraviolet light-emitting diodes (DUV-LEDs), λmax = 235, 250, and 280 nm, along with data acquisition and processing via a custom-made program. The pulse set generation and data acquisition were synchronized using the SBC. The outputs of the three pulsing DUV-LEDs were combined and transmitted to the flow cell via a solarisation resistant trifurcated optical fiber (OF). An ultra-fast responding photodiode was connected to the optical-fiber-compatible flow cell to record the intensity of the DUV pulses. Upper limit of detector linearity (A95 %) was found to be 1917 mAU, 2189 mAU, and 1768 mAU at 235 nm, 250 nm, and 280 nm, respectively, with stray light ≤0.9 %. In addition, the effective path length (Leff) was estimated to be ≥98.0 % of the length of the used flow cell (50 mm). The new pulsed multi-LEDs absorbance detector (PMLAD) has been successfully coupled with a standard liquid chromatograph and utilized for the analysis of pharmaceuticals. Paracetamol, caffeine, and aspirin were simultaneously determined at 250, 280, and 235 nm, respectively, using the PMLAD. The absorbance ratios between the different wavelengths were applied to further confirm the identity of the studied compounds. Excellent linearity was achieved over a range of 0.1-3.2 µg/mL for paracetamol, 0.4-6.4 µg/mL for caffeine, and 0.8-12.8 µg/mL for aspirin with a regression correlation coefficient (r2) ≥ 0.99996. The quantitation limits (LOQs) were 0.10 µg/mL, 0.38 µg/mL, and 0.66 µg/mL for paracetamol, caffeine, and aspirin, respectively.


Assuntos
Cafeína , Raios Ultravioleta , Acetaminofen , Cromatografia Líquida , Aspirina
9.
Antimicrob Agents Chemother ; 67(10): e0053523, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37768311

RESUMO

The clinical relevance of bacteriuria following antibiotic treatment of complicated urinary tract infections in clinical trials remains controversial. We evaluated the impact of urine pharmacokinetics on the timing of recurrent bacteriuria in a recently completed trial that compared oral tebipenem pivoxil hydrobromide to intravenous ertapenem. The urinary clearance and urine dwell time of ertapenem were prolonged relative to tebipenem and were associated with a temporal difference in the repopulation of bladder urine with bacteria following treatment, potentially confounding the assessment of efficacy.


Assuntos
Bacteriúria , Infecções Urinárias , Humanos , Bacteriúria/tratamento farmacológico , Bacteriúria/complicações , Antibacterianos/uso terapêutico , Antibacterianos/farmacocinética , Ertapenem/uso terapêutico , Infecções Urinárias/microbiologia
10.
J Sep Sci ; 46(15): e2300283, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37401843

RESUMO

Liquid chromatography is a prominent analytical technique in separation science and chemical analysis, applied across numerous fields of research and within industrial applications. Over the past few decades, there has been a growing interest in the miniaturization of this technique, which has been particularly enabled through new miniature and portable detection technologies for in-field, at-site, and point-of-need (collectively 'out-of-lab') analyses. Accordingly, significant advances have been made in recent years in the development of miniaturized liquid chromatography with photometric, electrochemical, and mass spectrometric detection, enabling the development of field-deployable and portable instruments for various applications. Herein, recent developments in the miniaturization of detection systems for inclusion within, and/or coupling with, portable liquid chromatographic systems, are reviewed in detail together with critical comments and expected future trends in this area.

11.
Clin Neurol Neurosurg ; 231: 107792, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37307711

RESUMO

The SAMMPRIS Trial concluded that medical treatment of intracranial stenosis was safer than intracranial stenting. The key reasons for a poor outcome with stenting were significantly more perioperative ischemic strokes and higher rates of intracerebral hemorrhages. To the contrary, WEAVE trial showed significantly lower morbidity and mortality when stenting was performed one week following the ictus. We describe the technical approach for safe basilar artery stenting through radial approach. A middle aged male presented with recurrent posterior circulation symptoms despite being on dual antiplatelet therapy. A right radial approach was undertaken. A 5f radial sheath was exchanged for an AXS infinity LS (Stryker Neurovascular, Ireland) 6 f sheath after priming the radial artery. Using a quadri-axial approach, 0.014' Traxcess microwire (Microvention Inc, Tustin, USA), 0.017' Echelon microcatheter (Microtherapeutics.inc. Ev3 Neurovascular, USA), 0.038 DAC (Stryker Neurovascular USA) & 5F Navien (Microtherapeutics.inc. Ev3 USA), the Infinity sheath was taken into the V2 segment of the right vertebral artery. The 5F Navien (tri-axial approach) was taken upto the distal V4 segment of the vertebral artery. The 3d rotational angiography directed runs revealed > 95 % stenosis of mid basilar segment. No significant ostial stenosis of side branch was noted and in view of long segment plaque angioplasty followed by deployment of self-expanding stent was planned. The microcatheter (0.017') and microwire (Traxcess 0.014') was navigated across the stenosis. Thereafter, an exchange maneuver was performed to allow for sequential slow balloon angioplasty with 1.5 mm × 15 (Maverick, Boston Scientific) and 2.5 mm× 15 (Trek, Abbott costa rica) coronary balloon. Following that a CREDO 4 × 20 mm stent (Acandis GmbH., Pforzheim Germany) was deployed across the stenosis. All exchange maneuvers were performed under biplane fluoroscopy and microwire was kept under watch. The patient was on aspirin and clopidogrel and activated clotting time was maintained around 250 s throughout the procedure. A closure device was applied post procedure. Blood pressure was monitored in neurointensive care unit and patient was discharged on the third day following procedure. Right radial approach, distal position of the sheath, distal position of the guiding catheter, careful analysis of the 3d rotational angiography for risk of side branch occlusion, biplane fluoroscopy during exchanges and slow angioplasty were the key safety checks during procedure.


Assuntos
Acidente Vascular Cerebral , Insuficiência Vertebrobasilar , Pessoa de Meia-Idade , Humanos , Masculino , Constrição Patológica , Acidente Vascular Cerebral/cirurgia , Angioplastia , Insuficiência Vertebrobasilar/diagnóstico por imagem , Insuficiência Vertebrobasilar/cirurgia , Hemorragia Cerebral , Stents , Artéria Basilar , Resultado do Tratamento
13.
Clin Neurol Neurosurg ; 231: 107795, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37352678

RESUMO

Transvenous onyx (Microtherapeutics, Irvine, CA, USA) embolization with sinus reconstruction using a venous balloon is a novel technique to embolise dural arterial venous fistula while preserving the sinus. We elucidate the technical tips and tricks that were employed to treat this torcular dural AVF in an elderly male with visual disturbances secondary to papilledema. Right external carotid artery injection revealed a type 2c fistula along the torcula with feeders from the right parietal & petrosal branches of the middle meningeal artery and dural branches of the posterior auricular and the occipital artery. The right distal transverse and the sigmoid were occluded with retrograde flow into the superior sagittal sinus and the cortical veins. XPER CTA analysis revealed the fistula point to be along the wall of the torcula. Through right femoral artery access, a neuron max (Penumbra inc.USA) was placed in the right common carotid artery. An eclipse (Balt Extrusion, France) 6 × 12 mm single lumen balloon was placed in the proximal ECA to achieve flow reduction. Thereafter, through bilateral femoral venous approach, two neuron max 8 F (Penumbra inc.USA) were placed into the left jugular vein. A Copernic RC balloon 10×80 mm (Balt Extrusion, France) was placed from the left to the right transverse sinus. Further, two microcatheters, 1.5 F Marathon (Medtronic, Minneapolis, MI, USA) were navigated into the feeding arteries from the venous end. Microcatheter injections were taken with inflation of the venous balloon to determine the point at which sinus and cortical vein reflux is absent. Following that onyx 18 was injected under biplane fluoroscopy with an adequately inflated arterial and venous balloon. We could achieve retrograde permeation of the onyx into the fistula and the arterial feeders resulting in complete occlusion while preserving the sinus. Careful analysis of the angioarchitecture of the fistula and evaluating for delayed cerebral venous drainage is the key to determining the right strategy to achieve complete occlusion of the fistula.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Veias Cerebrais , Embolização Terapêutica , Seios Transversos , Humanos , Masculino , Idoso , Malformações Vasculares do Sistema Nervoso Central/terapia , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Embolização Terapêutica/métodos , Seios Transversos/diagnóstico por imagem , Seios Transversos/cirurgia , Artérias
14.
ACS Omega ; 8(15): 13569-13577, 2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37091394

RESUMO

A novel, low-cost, and disposable thread-based electrofluidic analytical method employing isotachophoresis (ITP) was developed for demonstrating surface DNA hybridization. This approach was based on graphene oxide (GO) surface-functionalized zones on nylon threads as a binding platform to trap a fluorescently labeled isotachophoretically focused single-stranded DNA (ssDNA) band, resulting in quenching of the fluorescence, which signaled quantitative trapping. In the event of an isotachophoretically focused complementary DNA (cDNA) band passing over the GO-trapped ssDNA zone, surface hybridization of the ssDNA and cDNA to form double-stranded DNA (dsDNA) band occurred, which is released from the GO-coated zones, resulting in restoration of the fluorescent signal as it exits the GO band and migrates further along the thread. This controllable process demonstrates the potential of the GO-functionalized thread-based microfluidic analytical approach for DNA hybridization and its visualization, which could be adapted into point-of-care (POC) diagnostic devices for real-world applications.

15.
Analyst ; 148(7): 1543-1551, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-36880438

RESUMO

A new method and platform has been developed for direct transfer, electrophoretic separation, and pre-concentration of swabbed samples using the principles of thread-based electrofluidics. A direct electrokinetic injection has been observed for a variety of analytes ranging from small molecules to proteins. The effect of physicochemical interactions of the analyte with the swab and the thread on the transfer efficiency has been studied by exploring different swab and thread combinations. For fluorescein, using a polyurethane swab, 98% and 94% transfer efficiencies were observed on mercerised cotton and nylon thread, while only 80% transfer efficiency was observed on polyester thread, respectively. A 97% transfer of fluorescein was observed on the nylon thread when a flocked nylon swab was used, while only 47% transfer was observed when a cotton swab was used. A successful transfer has been observed for both liquid and dry samples from either pre-wetted or dry swabs in both the presence and absence of any surrounding electrolytes. The platform has been further adapted for multiplexed analysis, where a sample from a single swab was transferred onto two parallel thread systems with ca. 50% distribution between them. The method has been validated for transfer, separation, and pre-concentration of DNA from blood. It has also been successfully used to directly analyse dried blood samples using a commercial sampling device, Neoteryx Mitra.


Assuntos
Nylons , Manejo de Espécimes , Manejo de Espécimes/métodos , DNA , Fluoresceínas
16.
Antimicrob Agents Chemother ; 67(4): e0149522, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-36943038

RESUMO

Tebipenem pivoxil hydrobromide (TBP-PI-HBr) is a novel oral carbapenem prodrug being developed for the treatment of serious bacterial infections. This open-label, 3-period, fixed sequence study evaluated the effect of gastric acid-reducing agents, aluminum hydroxide/magnesium hydroxide/simethicone, and omeprazole on the pharmacokinetics (PK) of tebipenem (TBP), the active moiety, following coadministration with immediate release TBP-PI-HBr during fasting. In Period 1, subjects received a single oral dose of TBP-PI-HBr 600 mg (2 × 300 mg tablets). In Period 2, subjects received a single oral dose of aluminum hydroxide 800 mg/magnesium hydroxide 800 mg/simethicone 80 mg suspension co-administered with a single dose of TBP-PI-HBr 600 mg. In Period 3, subjects received a single oral dose of omeprazole 40 mg once daily over 5 days, followed by single dose administration of TBP-PI-HBr 600 mg on day 5. In each period, whole blood samples were obtained prior to, and up to 24 h, following TBP-PI-HBr dose administration in order to characterize TBP PK. A 7-day washout was required between periods. Twenty subjects were enrolled and completed the study. Following co-administration of TBP-PI-HBr with either aluminum hydroxide/magnesium hydroxide/simethicone or omeprazole, total TBP exposure (area under the curve [AUC]) was approximately 11% (geometric mean ratio 89.2, 90% confidence interval: 83,2, 95.7) lower, and Cmax was 22% (geometric mean ratio 78.4, 90% confidence interval: 67.9, 90.6) and 43% (geometric mean ratio 56.9, 90% confidence interval: 49.2, 65.8) lower, respectively, compared to administration of TBP-PI-HBr alone. Mean TBP elimination half-life (t1/2) was generally comparable across treatments (range: 1.0 to 1.5 h). Concomitant administration of TBP-PI-HBr with omeprazole or aluminum hydroxide/magnesium hydroxide/simethicone is not expected to impact the efficacy of TBP-PI-HBr, as there is minimal impact on TBP plasma AUC, which is the pharmacodynamic driver of efficacy. Co-administration was generally safe and well tolerated.


Assuntos
Antiácidos , Antiulcerosos , Adulto , Humanos , Administração Oral , Hidróxido de Alumínio/farmacologia , Antiácidos/farmacologia , Estudos Cross-Over , Interações Medicamentosas , Hidróxido de Magnésio/farmacologia , Omeprazol/farmacologia , Inibidores da Bomba de Prótons/farmacologia , Simeticone
17.
Antimicrob Agents Chemother ; 67(4): e0150922, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-36995239

RESUMO

Tebipenem pivoxil hydrobromide (TBP-PI-HBr) is an oral prodrug of pharmacologically active moiety tebipenem (TBP), which is a carbapenem with activity against multidrug-resistant Gram-negative pathogens. Conversion from the prodrug to the active moiety, namely, TBP, occurs in the enterocytes of the gastrointestinal tract via intestinal esterases. The absorption, metabolism, and excretion in humans were evaluated, following the administration of a single oral dose of [14C]-TBP-PI-HBr. Healthy male subjects (n = 8) received a single 600 mg oral dose of TBP-PI-HBr containing approximately 150 µCi of [14C]-TBP-PI-HBr. Blood, urine, and fecal samples were collected to determine the total radioactivity, concentrations of TBP (plasma only), and metabolite profiling and identification. The overall mean recovery of the total radioactivity in urine (38.7%) and feces (44.6%) combined was approximately 83.3% of the administered dose, with individual recoveries ranging from 80.1% to 85.0%. Plasma TBP LC-MS/MS and metabolite profiling data suggest that TBP was the main circulating component in plasma and that it accounts for approximately 54% of the total plasma radioactivity, based on the plasma AUC ratio of TBP/total radioactivity. The ring-open metabolite LJC 11562 was another major component in plasma (>10%). TBP (M12), LJC 11562, and four trace to minor metabolites were identified/characterized in the urine. TBP-PI, TBP (M12), and 11 trace to minor metabolites were identified/characterized in the feces. The renal and fecal routes are major clearance pathways in the elimination of [14C]-TBP-PI-HBr, with a mean combined recovery of 83.3%. TBP and its inactive ring-open metabolite LJC 11562 were the major circulating metabolites in the plasma.


Assuntos
Pró-Fármacos , Humanos , Masculino , Cromatografia Líquida , Espectrometria de Massas em Tandem , Fezes , Administração Oral , Radioisótopos de Carbono
18.
Indian J Ophthalmol ; 71(2): 436-443, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36727336

RESUMO

Purpose: To evaluate the efficacy of secondary and salvage intra-arterial chemotherapy (IAC) as a globe salvage treatment modality in advanced and refractory intraocular retinoblastoma. Methods: A retrospective chart review of advanced intraocular retinoblastoma (groups D and E International Classification of Retinoblastoma [ICRB] classification) patients refractory to intravenous chemotherapy (IVC) and undergoing IAC as the secondary and salvage treatment modality between December 2018 and June 2021 was carried out. All patients underwent the IAC procedure by super-selective ophthalmic artery catheterization and with triple-drug chemotherapeutic agents of melphalan, topotecan, and carboplatin. Data were collected about tumor regression, eye salvage, metastasis, and survival outcome at follow-up. Results: Out of 13 patients, 12 patients received secondary IAC after being primarily treated with IVC and focal therapies and one patient received rescue IAC after recurrence following primary IAC. Mean number of IAC cycles administered was 2. Overall, globe salvage rate was 53.84%, with a mean follow-up of 17.53 months (range 6-37 months), three patients had enucleation for residual tumor or tumor recurrence. One patient developed metastasis post enucleation and two patients who were lost to follow-up after enucleation advice for residual tumor developed orbital tumor extension and eventually died of metastasis. Conclusion: Secondary triple-drug IAC following failure of IVC, along with other adjunct treatment modalities might a be a cost-effective option for eye salvage in advanced intraocular retinoblastoma patients who refuse enucleation, with a globe salvage rate of 53.84%. It can also be an effective approach to improve treatment compliance and can help in addressing the barrier of treatment refusal when enucleation is advised.


Assuntos
Neoplasias da Retina , Retinoblastoma , Humanos , Lactente , Retinoblastoma/diagnóstico , Retinoblastoma/tratamento farmacológico , Neoplasias da Retina/diagnóstico , Neoplasias da Retina/tratamento farmacológico , Estudos Retrospectivos , Neoplasia Residual/tratamento farmacológico , Neoplasia Residual/etiologia , Resultado do Tratamento , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Infusões Intra-Arteriais , Recidiva Local de Neoplasia , Melfalan/uso terapêutico
19.
Nat Rev Mol Cell Biol ; 24(7): 477-494, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36781955

RESUMO

All organisms possess molecular mechanisms that govern DNA repair and associated DNA damage response (DDR) processes. Owing to their relevance to human disease, most notably cancer, these mechanisms have been studied extensively, yet new DNA repair and/or DDR factors and functional interactions between them are still being uncovered. The emergence of CRISPR technologies and CRISPR-based genetic screens has enabled genome-scale analyses of gene-gene and gene-drug interactions, thereby providing new insights into cellular processes in distinct DDR-deficiency genetic backgrounds and conditions. In this Review, we discuss the mechanistic basis of CRISPR-Cas genetic screening approaches and describe how they have contributed to our understanding of DNA repair and DDR pathways. We discuss how DNA repair pathways are regulated, and identify and characterize crosstalk between them. We also highlight the impacts of CRISPR-based studies in identifying novel strategies for cancer therapy, and in understanding, overcoming and even exploiting cancer-drug resistance, for example in the contexts of PARP inhibition, homologous recombination deficiencies and/or replication stress. Lastly, we present the DDR CRISPR screen (DDRcs) portal , in which we have collected and reanalysed data from CRISPR screen studies and provide a tool for systematically exploring them.


Assuntos
Sistemas CRISPR-Cas , Neoplasias , Humanos , Sistemas CRISPR-Cas/genética , Reparo do DNA/genética , Neoplasias/terapia , Neoplasias/tratamento farmacológico , Genoma , Dano ao DNA/genética
20.
J Gastrointest Cancer ; 54(2): 682-686, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35666356

RESUMO

INTRODUCTION: Oxaliplatin-based chemotherapy is commonly used in adjuvant treatment of colon cancer as well as in neoadjuvant setting in patients with liver metastases. However oxaliplatin can cause damage to non-tumor bearing liver which presents as sinusoidal obstructive syndrome (SOS). These changes are difficult to differentiate from metastasis clinic-radiologically and manifests as sinusoidal dilatation, peliosis and nodular regenerative hyperplasia. CASE: The present study reports the case of a patient with oxaliplatin-induced SOS which mimicked colo-rectal liver metastasis on follow up imaging studies after receiving neoadjuvant oxaliplatin based chemotherapy. After multidisciplinary discussion, patient was planned for simultaneous resection of rectal primary and right hepatectomy for metastasis. Final histopathology revealed no tumour in liver but the liver lesions seen radiologically were actually changes of oxaliplatin induced focal SOS and mimicked metastatic nodules. CONCLUSION: In patients with colo-rectal cancer having received oxaliplatin-based chemotherapy, SOS may be considered as one of the causes of newly developed liver lesions, and should be subjected to additional radio-pathologic evaluation to prevent overtreatment and avoiding potentially morbid surgeries.


Assuntos
Antineoplásicos , Neoplasias Colorretais , Hepatopatia Veno-Oclusiva , Neoplasias Hepáticas , Humanos , Oxaliplatina/efeitos adversos , Hepatopatia Veno-Oclusiva/induzido quimicamente , Hepatopatia Veno-Oclusiva/diagnóstico , Hepatopatia Veno-Oclusiva/tratamento farmacológico , Neoplasias Hepáticas/cirurgia , Neoplasias Colorretais/patologia , Hepatectomia , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Antineoplásicos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA