RESUMO

OBJECTIVE: Arteriovenous fistulas created for hemodialysis often fail to become usable and are frequently abandoned. This prospective trial evaluated the efficacy of vonapanitase, a recombinant human elastase, in increasing radiocephalic fistula use for hemodialysis and secondary patency. METHODS: PATENCY-2 was a randomized, double-blind, placebo-controlled trial in patients on or approaching the need for hemodialysis undergoing radiocephalic arteriovenous fistula creation. Of 696 screened, 613 were randomized, and 603 were treated (vonapanitase n = 405, placebo n = 208). The study drug solution was applied topically to the artery and vein for 10 min immediately after fistula creation. The primary endpoints were fistula use for hemodialysis and secondary patency (fistula survival without abandonment). Other efficacy endpoints included unassisted fistula use for hemodialysis, primary unassisted patency, fistula maturation and unassisted maturation by ultrasound criteria, and fistula procedure rates. RESULTS: The proportions of patients with fistula use for hemodialysis was similar between groups, 70% vonapanitase and 65% placebo, (p = 0.33). The Kaplan-Meier estimates of 12-month secondary patency were 78% (95% confidence interval [CI], 73-82) for vonapanitase and 76% (95% CI, 70-82) for placebo (p = 0.93). The proportions with unassisted fistula use for hemodialysis were 46% vonapanitase and 37% placebo (p = 0.054). The Kaplan-Meier estimates of 12-month primary unassisted patency were 50% (95% CI, 44-55) for vonapanitase and 43% (95% CI, 35-50) for placebo (p = 0.18). There were no differences in the proportion of patients with fistula maturation or in fistula procedure rates. Adverse events were similar between groups. Vonapanitase was not immunogenic. CONCLUSIONS: Vonapanitase treatment did not achieve clinical or statistical significance to meaningfully improve radiocephalic fistula surgical outcomes. Outcome in the placebo group were better than in historical controls. Vonapanitase was well-tolerated and safe. TRIAL REGISTRATION: clinicaltrials.gov: NCT02414841 (https://clinicaltrials.gov/ct2/show/NCT02414841).


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Fístula Arteriovenosa/etiologia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Proteínas de Transporte , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Elastase Pancreática/efeitos adversos , Estudos Prospectivos , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
J Vasc Access ; 15(5): 376-84, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24811601

RESUMO

PURPOSE: To explore the safety and efficacy of PRT-201 applied to the outflow vein of a newly created arteriovenous graft (AVG). METHODS: Randomized, double-blind, placebo-controlled, single-dose escalation study of PRT-201 (0.01 to 9 mg) applied to the graft-vein anastomosis and adjacent outflow vein immediately after AVG placement. The primary outcome measure was safety. The efficacy measures were intraoperative increases in outflow vein diameter and blood flow rate, primary unassisted patency, and secondary patency by dose groups (placebo, low, medium, high and All PRT-201). RESULTS: A total of 89 patients were treated (28 placebo and 61 PRT-201). There were no significant differences in the proportion of placebo and PRT-201 patients reporting adverse events. Intraoperative outflow vein diameter increased 5% (p=0.14) in the placebo group compared with 13% (p=0.01), 15% (p=0.07) and 12% (p<0.001), in the low, medium and high groups, respectively. The comparison between the high and placebo groups was marginally statistically significant (p=0.06). The intraoperative blood flow did not change in the placebo group, and increased in the low, medium and high groups by 19% (p=0.34), 36% (p=0.09) and 46% (p=0.02), respectively. The low group had the longest primary unassisted and secondary patency and the fewest procedures to restore or maintain patency; however, the differences between groups were not statistically significant. CONCLUSIONS: PRT-201 was well tolerated and increased AVG intraoperative outflow vein diameter and blood flow. Low dose tended to increase secondary patency and decrease the rate of procedures to restore or maintain patency. Larger studies with these doses will be necessary to confirm these results.


Assuntos
Derivação Arteriovenosa Cirúrgica , Proteínas de Transporte/administração & dosagem , Oclusão de Enxerto Vascular/prevenção & controle , Elastase Pancreática/administração & dosagem , Diálise Renal , Insuficiência Renal Crônica/terapia , Extremidade Superior/irrigação sanguínea , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Proteínas de Transporte/efeitos adversos , Método Duplo-Cego , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Elastase Pancreática/efeitos adversos , Fluxo Sanguíneo Regional , Insuficiência Renal Crônica/diagnóstico , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular , Veias/efeitos dos fármacos , Veias/fisiopatologia , Veias/cirurgia
3.
J Vasc Access ; 14(2): 143-51, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23172172

RESUMO

PURPOSE: To explore the safety and efficacy of PRT-201. METHODS: Randomized, double-blind, placebo-controlled, single-dose escalation study of PRT-201 (0.0033 to 9 mg) applied after arteriovenous fistula (AVF) creation. Participants were followed for one year. The primary outcome measure was safety. Efficacy measures were the proportion with intra-operative increases in AVF outflow vein diameter or blood flow ≥25% (primary), changes in outflow vein diameter and blood flow, AVF maturation and lumen stenosis by ultrasound criteria and AVF patency. RESULTS: The adverse events in the PRT-201 group (n=45) were similar to those in the placebo group (n=21). There were no differences in the proportion with ≥25% increase in vein diameter or blood flow, successful maturation or lumen stenosis. There was no statistically significant difference in primary patency between the dose groups (placebo n=21, Low Dose n=16, Medium Dose n=17 and High Dose n=12). In a subgroup analysis that excluded three participants with early surgical failures, the hazard ratio (HR) for primary patency loss of Low Dose compared with placebo was 0.38 (95% CI 0.10-1.41, P=0.15). In a Cox model, Low Dose (HR 0.27, 95% CI 0.04-0.79, P=0.09), white race (HR 0.17, 95% CI 0.03-0.79, P=0.02), and age <65 years (HR 0.25, CI 0.05-1.15, P=0.08) were associated (P<0.10) with a decreased risk of primary patency loss. CONCLUSIONS: PRT-201 was not different from placebo for safety or efficacy measures. There was a suggestion for improved AVF primary patency with Low Dose PRT-201 that is now being studied in a larger clinical trial.


Assuntos
Derivação Arteriovenosa Cirúrgica , Proteínas de Transporte/administração & dosagem , Oclusão de Enxerto Vascular/prevenção & controle , Diálise Renal , Trombose/prevenção & controle , Extremidade Superior/irrigação sanguínea , Adulto , Idoso , Análise de Variância , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Método Duplo-Cego , Esquema de Medicação , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Elastase Pancreática , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Trombose/etiologia , Trombose/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular/efeitos dos fármacos
4.
Biotechnol Appl Biochem ; 59(1): 22-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22332741

RESUMO

PRT-201 is a recombinant human pancreatic elastase under development as a treatment for blood vessels to promote hemodialysis access patency. Proteases such as elastase are normally inactivated by antiproteases such as alpha 1-antitrypsin. It is unknown if serum from patients with alpha 1-antitrypsin deficiency will inhibit PRT-201 elastase activity. An assay for PRT-201 elastase activity in the presence of serum was developed and validated. PRT-201 elastase activity inhibition curves were developed using serum and also using purified alpha 1-antitrypsin and alpha 2-macroglobulin. Serum from 15 patients with documented alpha 1-antitrypsin deficiency, some of whom were receiving alpha 1-antitrypsin augmentation therapy, and four normal volunteers was analyzed. Serum from normal volunteers and patients with alpha 1-antitrypsin deficiency completely inactivated PRT-201 elastase activity in vitro. In the alpha 1-antitrypsin-deficient patients, the volume of serum necessary to inhibit elastase activity was related to the serum concentration of alpha 1-antitrypsin and augmentation therapy. Purified alpha 1-antitrypsin and alpha 2-macroglobulin were each alone capable of completely inhibiting PRT-201 elastase activity. It is unlikely that the use of PRT-201 will be associated with negative outcomes in patients with alpha 1-antitrypsin deficiency.


Assuntos
Elastase Pancreática/antagonistas & inibidores , Soro , Deficiência de alfa 1-Antitripsina/sangue , Adulto , Idoso , Diabetes Mellitus Tipo 1/enzimologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Elastase Pancreática/metabolismo , Proteínas Recombinantes/antagonistas & inibidores , Proteínas Recombinantes/metabolismo , Deficiência de alfa 1-Antitripsina/metabolismo