1.
J Appl Crystallogr ; 56(Pt 3): 776-786, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37284267

RESUMO

Two wafers of one 4H-silicon carbide (4H-SiC) bulk crystal, one cut from a longitudinal position close to the crystal's seed and the other close to the cap, were characterized with synchrotron white-beam X-ray topography (SWXRT) in back-reflection and transmission geometry to investigate the dislocation formation and propagation during growth. For the first time, full wafer mappings were recorded in 00012 back-reflection geometry with a CCD camera system, providing an overview of the dislocation arrangement in terms of dislocation type, density and homogeneous distribution. Furthermore, by having similar resolution to conventional SWXRT photographic film, the method enables identification of individual dislocations, even single threading screw dislocations, which appear as white spots with a diameter in the range of 10 to 30 µm. Both investigated wafers showed a similar dislocation arrangement, suggesting a constant propagation of dislocations during crystal growth. A systematic investigation of crystal lattice strain and tilt at selected wafer areas with different dislocation arrangements was achieved with high-resolution X-ray diffractometry reciprocal-space map (RSM) measurements in the symmetric 0004 reflection. It was shown that the diffracted intensity distribution of the RSM for different dislocation arrangements depends on the locally predominant dislocation type and density. Moreover, the orientation of specific dislocation types along the RSM scanning direction has a strong influence on the local crystal lattice properties.

2.
Sci Rep ; 13(1): 1055, 2023 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-36658141

RESUMO

Hierarchical guidance is developed for three-dimensional (3D) nanoscale X-ray imaging, enabling identification, refinement, and tracking of regions of interest (ROIs) within specimens considerably exceeding the field of view. This opens up new possibilities for in situ investigations. Experimentally, the approach takes advantage of rapid multiscale measurements based on magnified projection microscopy featuring continuous zoom capabilities. Immediate and continuous feedback on the subsequent experimental progress is enabled by suitable on-the-fly data processing. For this, by theoretical justification and experimental validation, so-called quasi-particle phase-retrieval is generalised to conical-beam conditions, being key for sufficiently fast computation without significant loss of imaging quality and resolution compared to common approaches for holographic microscopy. Exploiting 3D laminography, particularly suited for imaging of ROIs in laterally extended plate-like samples, the potential of hierarchical guidance is demonstrated by the in situ investigation of damage nucleation inside alloy sheets under engineering-relevant boundary conditions, providing novel insight into the nanoscale morphological development of void and particle clusters under mechanical load. Combined with digital volume correlation, we study deformation kinematics with unprecedented spatial resolution. Correlation of mesoscale (i.e. strain fields) and nanoscale (i.e. particle cracking) evolution opens new routes for the understanding of damage nucleation within sheet materials with application-relevant dimensions.

3.
J Synchrotron Radiat ; 24(Pt 6): 1283-1295, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091072

RESUMO

An open-source framework for conducting a broad range of virtual X-ray imaging experiments, syris, is presented. The simulated wavefield created by a source propagates through an arbitrary number of objects until it reaches a detector. The objects in the light path and the source are time-dependent, which enables simulations of dynamic experiments, e.g. four-dimensional time-resolved tomography and laminography. The high-level interface of syris is written in Python and its modularity makes the framework very flexible. The computationally demanding parts behind this interface are implemented in OpenCL, which enables fast calculations on modern graphics processing units. The combination of flexibility and speed opens new possibilities for studying novel imaging methods and systematic search of optimal combinations of measurement conditions and data processing parameters. This can help to increase the success rates and efficiency of valuable synchrotron beam time. To demonstrate the capabilities of the framework, various experiments have been simulated and compared with real data. To show the use case of measurement and data processing parameter optimization based on simulation, a virtual counterpart of a high-speed radiography experiment was created and the simulated data were used to select a suitable motion estimation algorithm; one of its parameters was optimized in order to achieve the best motion estimation accuracy when applied on the real data. syris was also used to simulate tomographic data sets under various imaging conditions which impact the tomographic reconstruction accuracy, and it is shown how the accuracy may guide the selection of imaging conditions for particular use cases.

4.
Opt Express ; 24(4): 4331-48, 2016 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-26907079

RESUMO

The interactions of a beam of hard and spatio-temporally coherent X-rays with a soft-matter sample primarily induce a transverse distribution of exit phase variations δϕ (retardations or advancements in pieces of the wave front exiting the object compared to the incoming wave front) whose free-space propagation over a distance z gives rise to intensity contrast gz. For single-distance image detection and |δϕ| ≪ 1 all-order-in-z phase-intensity contrast transfer is linear in δϕ. Here we show that ideal coherence implies a decay of the (shot-)noise-to-signal ratio in gz and of the associated phase noise as z(-1/2) and z(-1), respectively. Limits on X-ray dose thus favor large values of z. We discuss how a phase-scaling symmetry, exact in the limit δϕ → 0 and dynamically unbroken up to |δϕ| ∼ 1, suggests a filtering of gz in Fourier space, preserving non-iterative quasi-linear phase retrieval for phase variations up to order unity if induced by multi-scale objects inducing phase variations δϕ of a broad spatial frequency spectrum. Such an approach continues to be applicable under an assumed phase-attenuation duality. Using synchrotron radiation, ex and in vivo microtomography on frog embryos exemplifies improved resolution compared to a conventional single-distance phase-retrieval algorithm.

5.
IEEE Trans Image Process ; 22(12): 5348-61, 2013 12.
Artigo em Inglês | MEDLINE | ID: mdl-24228274

RESUMO

Computed laminography (CL) was developed to use X-rays from synchrotron sources for high-resolution imaging of the internal structure of a flat specimen from a series of 2-D projection images. The projections are acquired by irradiation of the sample under different rotation angles where the object rotation axis is inclined with respect to the beam direction. This yields for laterally extended objects a more uniform average transmitted intensity during sample rotation compared with computed tomography (CT). The reconstruction problem of CL cannot be reduced to a data-efficient 2-D case (as for parallel-beam CT) since each single slice perpendicular to the rotation axis requires a 2-D region on the detector as input data for all projection directions. This paper describes a computationally efficient reconstruction procedure based on filtered backprojection (FBP) adapted to the CL acquisition geometry. From the Fourier slice theorem, we derive a framework for analytic image reconstruction and outline implementation details of the generic FBP algorithm. Different approaches reducing the reconstruction time by means of parallel and distributed computations are considered and evaluated.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Raios X/métodos , Imagens de Fantasmas
6.
Opt Express ; 20(6): 6496-508, 2012 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-22418532

RESUMO

Synchrotron laminography is combined with Talbot grating interferometry to address weakly absorbing specimens. Integrating both methods into one set-up provides a powerful x-ray diagnostical technique for multiple contrast screening of macroscopically large flat specimen and a subsequent non-destructive three-dimensional (3-D) inspection of regions of interest. The technique simultaneously yields the reconstruction of the 3-D absorption, phase, and the so-called dark-field contrast maps. We report on the theoretical and instrumental implementation of of this novel technique. Its broad application potential is exemplarily demonstrated for the field of cultural heritage, namely study of the historical Dead Sea parchment.


Assuntos
Interferometria/instrumentação , Modelos Teóricos , Refratometria/instrumentação , Síncrotrons/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
7.
J Synchrotron Radiat ; 18(Pt 5): 753-60, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21862856

RESUMO

In this work an X-ray imaging system based on a recently developed in-line two-dimensional Bragg magnifier composed of two monolithic V-shaped crystals made of dislocation-free germanium is presented. The channel-cut crystals were used in one-dimensional and in two-dimensional (crossed) configurations in imaging applications and allowed measurement of phase-contrast radiograms both in the edge-enhanced and in the holographic regimes. The measurement of the phase gradient in two orthogonal directions is demonstrated. The effective pixel size attained was 0.17 µm in the one-dimensional configuration and 0.5 µm in the two-dimensional setting, offering a twofold improvement in spatial resolution over devices based on silicon. These results show the potential for applying Bragg magnifiers to imaging soft matter at high resolution with reduced dose owing to the higher efficiency of Ge compared with Si.