Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Water Res ; 254: 121374, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38422696

RESUMO

Intense rainfall and snowmelt events may affect the safety of drinking water, as large quantities of fecal material can be discharged from storm or sewage overflows or washed from the catchment into drinking water sources. This study used ß-d-glucuronidase activity (GLUC) with microbial source tracking (MST) markers: human, bovine, porcine mitochondrial DNA markers (mtDNA) and human-associated Bacteroidales HF183 and chemical source tracking (CST) markers including caffeine, carbamazepine, theophylline and acetaminophen, pathogens (Giardia, Cryptosporidium, adenovirus, rotavirus and enterovirus), water quality indicators (Escherichia coli, turbidity) and hydrometeorological data (flowrate, precipitation) to assess the vulnerability of 3 drinking water intakes (DWIs) and identify sources of fecal contamination. Water samples were collected under baseline, snow and rain events conditions in urban and agricultural catchments (Québec, Canada). Dynamics of E. coli, HF183 and WWMPs were similar during contamination events, and concentrations generally varied over 1 order of magnitude during each event. Elevated human-associated marker levels during events demonstrated that urban DWIs were impacted by recent contamination from an upstream municipal water resource recovery facility (WRRF). In the agricultural catchment, mixed fecal pollution was observed with the occurrences and increases of enteric viruses, human bovine and porcine mtDNA during peak contaminating events. Bovine mtDNA qPCR concentrations were indicative of runoff of cattle-derived fecal pollutants to the DWI from diffuse sources following rain events. This study demonstrated that the suitability of a given MST or CST indicator depend on river and catchment characteristics. The sampling strategy using continuous online GLUC activity coupled with MST and CST markers analysis was a more reliable source indicator than turbidity to identify peak events at drinking water intakes.


Assuntos
Criptosporidiose , Cryptosporidium , Água Potável , Enterovirus , Animais , Bovinos , Suínos , Humanos , Escherichia coli , Monitoramento Ambiental , DNA Mitocondrial , Glucuronidase
2.
Sci Total Environ ; 811: 152060, 2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-34861306

RESUMO

In urban areas served by separate sewerage systems, illicit connections to the storm drain system from residences or commercial establishments are frequent whether these misconnections were made accidentally or deliberately. As a result, untreated and contaminated wastewater enters into storm sewers leading to pollution of receiving waters and non-compliance with water quality standards. Typical procedures for detecting illicit connections to the storm sewer system are time consuming and expensive, especially in a highly urbanised area. In this study, we investigated the use of human wastewater micropollutants WWMPs (caffeine, theophylline, and carbamazepine) and advanced DNA molecular markers (human specific Bacteroides HF183 and mitochondrial DNA) as anthropogenic tracers in order to assist identifying potential cross connections. Water samples from storm outfalls and storm sewer pipes in three urban subcatchments were collected in dry weather from 2013 to 2018. All samples contained various concentrations of these markers especially HF183, caffeine and theophylline, suggesting that the storm pipe system studied is widely contaminated by sanitary sewers. None of the traditional indicators or markers tested is sufficient alone to determine the origin of fecal pollution. In a highly urbanised area, the combination of at least three specific human markers was needed in order to locate the residential section with likely misconnections. The human specific Bacteroides HF183, and theophylline appeared to be the most effective markers (along with E. coli) of crossconnections, whereas carbamazepine can provide an indication of contamination through sanitary sewer exfiltration. A composite sewer cross-connection index was developed, and eight misconnected houses were identified and corrected. The index approach enables the reduction of false positives that could lead to expensive interventions to identify cross-connected households. The results show the multiparameter source tracking toolbox as an effective method to identify sewer cross connections for sustainable storm water management.


Assuntos
Monitoramento Ambiental , Escherichia coli , Fezes/química , Humanos , Esgotos/análise , Águas Residuárias/análise , Qualidade da Água
3.
Water Res ; 200: 117296, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-34098267

RESUMO

A monitoring strategy was implemented at two drinking water treatment plants in Quebec, Canada, to evaluate microbial reduction performances of full-scale treatment processes under different source water conditions. ß-D-glucuronidase activity in source water was automatically monitored in near-real-time to establish baseline and event conditions at each location. High-volume water samples (50-1,500 L) were collected at the inflow and the outflow of coagulation/flocculation, filtration, and UV disinfection processes and were analysed for two naturally occurring surrogate organisms: Escherichia coli and Clostridium perfringens. Source water Cryptosporidium data and full-scale C. perfringens reduction data were entered into a quantitative microbial risk assessment (QMRA) model to estimate daily infection risks associated with exposures to Cryptosporidium via consumption of treated drinking water. Daily mean E. coli and Cryptosporidium concentrations in source water under event conditions were in the top 5% (agricultural site) or in the top 15% (urban site) of what occurs through the year at these drinking water treatment plants. Reduction performances of up to 6.0-log for E. coli and 5.6-log for C. perfringens were measured by concentrating high-volume water samples throughout the treatment train. For both drinking water treatment plants, removal performances by coagulation/flocculation/sedimentation processes were at the high end of the range of those reported in the literature for bacteria and bacterial spores. Reductions of E. coli and C. perfringens by floc blanket clarification, ballasted clarification and rapid sand filtration did not deteriorate during two snowmelt/rainfall events. QMRA results suggested that daily infection risks were similar during two rainfall/snowmelt events than during baseline conditions. Additional studies investigating full-scale reductions would be desirable to improve the evaluation of differences in treatment performances under various source water conditions.


Assuntos
Criptosporidiose , Cryptosporidium , Água Potável , Purificação da Água , Canadá , Escherichia coli , Humanos , Quebeque , Microbiologia da Água
4.
Water Res X ; 11: 100091, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33598650

RESUMO

This study investigates short-term fluctuations in virus concentrations in source water and their removal by full-scale drinking water treatment processes under different source water conditions. Transient peaks in raw water faecal contamination were identified using in situ online ß-d-glucuronidase activity monitoring at two urban drinking water treatment plants. During these peaks, sequential grab samples were collected at the source and throughout the treatment train to evaluate concentrations of rotavirus, adenovirus, norovirus, enterovirus, JC virus, reovirus, astrovirus and sapovirus by reverse transcription and real-time quantitative PCR. Virus infectivity was assessed through viral culture by measurement of cytopathic effect and integrated cell culture qPCR. Virus concentrations increased by approximately 0.5-log during two snowmelt/rainfall episodes and approximately 1.0-log following a planned wastewater discharge upstream of the drinking water intake and during a ß-d-glucuronidase activity peak in dry weather conditions. Increases in the removal of adenovirus and rotavirus by coagulation/flocculation processes were observed during peak virus concentrations in source water, suggesting that these processes do not operate under steady-state conditions but dynamic conditions in response to source water conditions. Rotavirus and enterovirus detected in raw and treated water samples were predominantly negative in viral culture. At one site, infectious adenoviruses were detected in raw water and water treated by a combination of ballasted clarification, ozonation, GAC filtration, and UV disinfection operated at a dose of 40 mJ cm-2. The proposed sampling strategy can inform the understanding of the dynamics associated with virus concentrations at drinking water treatment plants susceptible to de facto wastewater reuse.

5.
Risk Anal ; 41(8): 1413-1426, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33103797

RESUMO

Temporal variations in concentrations of pathogenic microorganisms in surface waters are well known to be influenced by hydrometeorological events. Reasonable methods for accounting for microbial peaks in the quantification of drinking water treatment requirements need to be addressed. Here, we applied a novel method for data collection and model validation to explicitly account for weather events (rainfall, snowmelt) when concentrations of pathogens are estimated in source water. Online in situ ß-d-glucuronidase activity measurements were used to trigger sequential grab sampling of source water to quantify Cryptosporidium and Giardia concentrations during rainfall and snowmelt events at an urban and an agricultural drinking water treatment plant in Quebec, Canada. We then evaluate if mixed Poisson distributions fitted to monthly sampling data ( n = 30 samples) could accurately predict daily mean concentrations during these events. We found that using the gamma distribution underestimated high Cryptosporidium and Giardia concentrations measured with routine or event-based monitoring. However, the log-normal distribution accurately predicted these high concentrations. The selection of a log-normal distribution in preference to a gamma distribution increased the annual mean concentration by less than 0.1-log but increased the upper bound of the 95% credibility interval on the annual mean by about 0.5-log. Therefore, considering parametric uncertainty in an exposure assessment is essential to account for microbial peaks in risk assessment.


Assuntos
Criptosporidiose/parasitologia , Água Potável/parasitologia , Giardia , Giardíase/parasitologia , Chuva , Medição de Risco/métodos , Neve , Cidades , Criptosporidiose/prevenção & controle , Cryptosporidium , Monitoramento Ambiental , Giardíase/prevenção & controle , Humanos , Quebeque , Rios , Microbiologia da Água , Purificação da Água
6.
Sci Total Environ ; 659: 548-560, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31096384

RESUMO

A set of fecal indicator bacteria and alternative markers were tested for their use to identify priority sectors of two urban watersheds in the Greater Montreal region with unintended household sewage connections to storm drainage systems. Analyses were performed for thermotolerant (fecal) coliforms (FC), Escherichia coli, human-specific Bacteroidales (HF183) and mitochondrial DNA (Hmt) markers, carbamazepine (CBZ), caffeine (CAF), theophylline (THEO) and acetaminophen (ACE). A high incidence of human fecal contamination was observed, illustrating the need for a method to appropriately prioritize sectors for the rehabilitation of sewer cross-connections. Concentrations of alternative markers were not significantly different between the residential and industrial/commercial/institutional (ICI) sectors. However, median E. coli concentrations were higher in the residential as compared to ICI sectors (p < 0.05). Hmt marker, CAF, and THEO were well correlated to E. coli in the ICI sector (r > 0.61, p < 0.05). Considering all sites, only CAF and THEO were correlated to E. coli (r > 0.59, p < 0.05), possibly as a result of higher E. coli inputs from other sources such as domestic animals or fauna in the residential sector. Thresholds were determined to relate alternative markers to E. coli for use in an index for prioritizing sectors with sewer cross-connections. HF183, Hmt, CAF, THEO, and ACE were identified as suitable markers for identifying sewer cross-connections and are more reliable than E. coli alone, most importantly in residential sectors.


Assuntos
Monitoramento Ambiental , Fezes/química , Fezes/microbiologia , Águas Residuárias/análise , Águas Residuárias/microbiologia , Microbiologia da Água , Poluentes Químicos da Água/análise , Marcadores Genéticos , Quebeque
7.
Sci Total Environ ; 635: 144-155, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29660718

RESUMO

Extensive environmental monitoring was conducted in an urban river impacted by multiple combined sewer overflows (CSOs) and wastewater treatment plant (WWTP) discharge points. Temporal and spatial distributions of dissolved and particulate steroids (progesterone (Prog), testosterone (Testo), medroxyprogesterone (MDRXY-Prog), levonorgestrel (Levo), norethindrone (Nore), estrone (E1), estradiol (E2), estriol (E3), and 17α-ethinylestradiol (EE2)) were investigated in sewage, WWTP effluents, receiving river water and sediments, and in drinking water plant (DWP) intakes. Steroids were detected in both dissolved and particulate phases with mean concentrations from 21ngL-1 to 389ngL-1 in raw sewage and from 10ngL-1 to 296ngL-1 in treated wastewater. The particle-associated steroids represented 0-82% of their total concentration as some steroids like E1 and E3 were detected only in the dissolved phase while MDRXY-Prog (81%), Nore (71%), and EE2 (>75%) were primarily detected in the particulate phase. Particle-associated steroids were detected in spring samples from river water with mean concentrations ranging from 5.4ngL-1 to 35.7ngL-1 compare to 3ngL-1 to 6.8ngL-1 in summer samples. Levels of particle-associated Testo, Nore, E2 and Levo in DWP intakes (406.2-13,149.1ngg-1) were similar to those found in raw sewage (336.6-7628.8ngg-1), indicating their persistence in the suspended phase from discharge points. Total steroids measured in sediments were in the range of 7-1213ngg-1, 5-25ngg-1, and 22-226ngg-1 in autumn, spring, and summer, respectively. Our findings confirm the presence and seasonal variation of a mixture of particle-associated steroids in drinking water sources. The presence of high concentrations of a mixture of particle-associated steroids in DWP intakes highlight the need for highly effective particle-removal processes to eliminate these recalcitrant compounds during drinking water production. Finally, the detected concentrations raise concerns about their potential environmental effects.


Assuntos
Sedimentos Geológicos/análise , Hormônios Esteroides Gonadais/análise , Rios/química , Esgotos/análise , Esteroides/análise , Poluentes Químicos da Água/análise , Água Potável/análise , Monitoramento Ambiental , Humanos , Quebeque , Estações do Ano , Eliminação de Resíduos Líquidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA