Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Clin Med ; 13(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38929985

RESUMO

The incidence of hip fractures has continued to increase as life expectancy increases. Hip fracture is one of the leading causes of increased morbidity and mortality in the geriatric population. Early surgical treatment (<48 h) is often recommended to reduce morbidity/mortality. In addition, adequate pain management is crucial to optimize functional recovery and early mobilization. Pain management often consists of multimodal therapy which includes non-opioids, opioids, and regional anesthesia techniques. In this review, we describe the anatomical innervation of the hip joint and summarize the commonly used peripheral nerve blocks to provide pain relief for hip fractures. We also outline literature evidence that shows each block's efficacy in providing adequate pain relief. The recent discovery of a nerve block that may provide adequate sensory blockade of the posterior capsule of the hip is also described. Finally, we report a surgeon's perspective on nerve blocks for hip fractures.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38739294

RESUMO

PURPOSE: Appropriate management of acute postoperative pain is critical for patient care and practice management. The purpose of this study was to determine whether postoperative pain score correlates with injury severity in tibial plateau fractures. METHODS: A retrospective review of prospectively collected data was completed at a single academic level one trauma center. All adult patients treated operatively for tibial plateau fractures who did not have concomitant injuries, previous injury to the ipsilateral tibia or knee joint, compartment syndrome, inadequate follow-up, or perioperative regional anesthesia were included (n = 88). The patients were split into groups based on the AO/OTA fracture classification (B-type vs C-type), energy mechanism, number of surgical approaches, need for temporizing external fixation, and operative time as a proxy for injury severity. The primary outcome measure was the visual analog scale (VAS) pain score (average in the first 24 h, highest in the first 24 h, two- and six-week postoperative appointments). Psychosocial and comorbid factors that may affect pain were studied and controlled for (history of diabetes, neuropathy, anxiety, depression, PTSD, and previous opioid prescription). Additionally, opioid use in the postoperative period was studied and controlled for (morphine milligram equivalents (MME) administered in the first 24 h, discharge MME/day, total discharge MME, and opioid refills). RESULTS: VAS scores were similar between groups at each time point except the two-week postoperative time point. At the two-week postoperative time point, the absolute difference between the groups was 1.3. The groups were significantly different in several injury and surgical variables as expected, but were similar in all demographic, comorbid, and postoperative opioid factors. CONCLUSIONS: There was no clinical difference in postoperative pain between AO/OTA 41B and 41C tibial plateau fractures. This supports the idea of providers uncoupling nociception and pain in postoperative patients. Providers should consider minimizing extended opioid use, even in more severe injuries.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38587621

RESUMO

PURPOSE: This study aims to explore the prevalence of dysphagia, as well as mortality associated with dysphagia in the elderly population receiving surgical treatment for a hip fracture. METHODS: A retrospective cohort study was completed at an academic level 1 tertiary care center. Patients older than or equal to 65 admitted with a hip fracture diagnosis from January 2015 to December 2020 (n = 617) were included. The main outcome was the prevalence of dysphagia and association with mortality. Secondary analysis included timing of dysphagia and contributions to mortality. RESULTS: Fifty-six percent of patients had dysphagia, and the mortality rates were higher in patients with dysphagia (8.9%) versus those without dysphagia (2.6%), chi-square p = 0.001, and odds ratio 3.69 (CI 1.6-8.5). Mortality rates in patients with acute dysphagia were also higher (12.4%) than those with chronic dysphagia (5%) and chi-squared p = 0.02. Mortality rates in patients with a perioperative dysphagic event (13.9%) were higher than those with non-perioperative dysphagia (4%) and chi-squared p = 0.001. Mortality rates in patients who had acute perioperative dysphagia (21.2%) were higher than those with chronic dysphagia that presented perioperatively (6.8%) and chi-squared p = 0.006. CONCLUSIONS: This study demonstrates high rates of dysphagia in the elderly hip fracture population and a significant association between dysphagia and mortality. Timing and chronicity of dysphagia were relevant, as patients with acute perioperative dysphagia had the highest mortality rate. Unlike other identified risk factors, dysphagia may be at least partially modifiable. More research is needed to determine whether formal evaluation and treatment of dysphagia lowers mortality risk.

4.
Injury ; 55(3): 111325, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38241955

RESUMO

INTRODUCTION: Traumatic brain injuries (TBIs) can be difficult to diagnose and are often marginalized when compared to more obvious physical injuries. Despite this, recognition and early treatment can lead to improved outcomes. Even mild TBIs have the potential to cause significant long-term consequences for patients, which may affect their physical recovery from orthopaedic injuries. The objective of this study was to examine the incidence and treatment of TBI within the orthopaedic trauma population. METHODS: Inclusion criteria were all patients presenting after an acute trauma with an orthopaedic surgery consult over a continuous 3 month timeframe (n = 187). A retrospective review was completed at an academic tertiary referral trauma center. The primary outcome was the rate of TBI. Secondary outcomes included rate of TBI listed as a discharge diagnosis and rate of follow up plan. Several secondary variables were noted and their associations with TBI evaluated. RESULTS: 27 % of the 187 patients had an acute TBI. 61 % of TBI patients had the diagnosis listed in their discharge summary. 6 % had a follow up plan. The positive TBI group was associated with more high energy injuries (p = 0.032), average limbs involved (p = 0.007), upper extremity injury (p < 0.001), bilateral lower extremity injury (p = 0.004), and Injury Severity Score (p < 0.001). 82 % of patients with an acute TBI had an occupational therapy consult and 39 % had a neurosurgery consult. 24 % of patients with a TBI were admitted to the orthopaedic primary service. CONCLUSIONS: Patients presenting after an acute trauma with orthopaedic injuries have high rates of TBI, but low rates of diagnosis and treatment. This lack of diagnosis and treatment can negatively impact recovery from orthopaedic injuries. Orthopaedic providers should be aware of the diagnostic criteria and initial treatment steps for TBI to ensure prompt and effective treatment, which has been shown to improve outcomes.


Assuntos
Concussão Encefálica , Lesões Encefálicas Traumáticas , Ortopedia , Humanos , Lesões Encefálicas Traumáticas/epidemiologia , Lesões Encefálicas Traumáticas/terapia , Lesões Encefálicas Traumáticas/diagnóstico , Resultado do Tratamento , Estudos Retrospectivos
5.
J Orthop Trauma ; 37(11): 553-556, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37348037

RESUMO

OBJECTIVE: To identify reasons for nonmedical delays in femur, pelvis, and acetabular fracture fixation at an institution with a dedicated orthopaedic trauma room (DOTR) and an early appropriate care practice model. DESIGN: Retrospective review of a prospective registry. SETTING: Urban Level 1 trauma center. PATIENTS/PARTICIPANTS: Two hundred ninety-four patients undergoing 313 procedures for 226 femur, 63 pelvis, and 42 acetabular fractures. INTERVENTION: Definitive fixation. MAIN OUTCOME MEASUREMENTS: Reasons for delays in fixation after hospital day 2. RESULTS: Delays occurred in 12.5% of procedures (39/313), with 7.7% (24/313) having medical delays and 4.8% (15/313) having nonmedical delays. Nonmedical delays were most commonly due to the operating room being at-capacity (n = 6) and nonpelvic trauma specialists taking weekend call (n = 5). Procedures with nonmedical delays were associated with younger age (median difference -16.0 years, 95% confidence interval [CI], -28 to -5.0; P = 0.006), high-energy mechanisms (proportional difference [PD] 58.5%, 95% CI, 37.0-69.7; P < 0.0001), Thursday through Saturday hospital admission (PD 30.3%, 95% CI, 5.0-50.0; P < 0.0001), pelvis/acetabular fractures (PD 51.8%, 95% CI, 26.7-71.0%; P < 0.0001), and external fixation (PD 33.0%, 95% CI, 11.8-57.3; P < 0.0001). CONCLUSION: Only 4.8% of procedures experienced nonmedical delays using an early appropriate care model and a DOTR. Nonmedical delays were most commonly due to 2 modifiable factors-the DOTR being at-capacity and nonpelvis trauma specialists taking weekend call. Patients with nonmedical delays were more likely to be younger, with pelvis/acetabular fractures, high-energy mechanisms, external fixation, and to be admitted between Thursday and Saturday. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

6.
J Arthroplasty ; 38(11): 2342-2346.e1, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37271234

RESUMO

BACKGROUND: Hemiparesis increases the risk of femoral neck fracture (FNF) in the elderly, which frequently necessitates hemiarthroplasty. There are limited reports on the outcomes of hemiarthroplasty in patients who have hemiparesis. The purpose of this study was to evaluate hemiparesis as a potential risk factor for medical and surgical complications following hemiarthroplasty. METHODS: Hemiparetic patients who have concomitant FNF and underwent hemiarthroplasty with at least 2 years of follow-up were identified using a national insurance database. A 10:1 matched control cohort of patients who did not have hemiparesis was created for comparison. There were 1,340 patients who have and 12,988 patients who did not have hemiparesis undergoing hemiarthroplasty for FNF. Multivariate logistic regression analyses were used to evaluate rates of medical and surgical complications between the 2 cohorts. RESULTS: Aside from increased rates of medical complications including cerebrovascular accident (P < .001), urinary tract infection (P = .020), sepsis (P = .002), and myocardial infarction (P < .001), patients who have hemiparesis also experienced higher rates of dislocation within 1 and 2 years (Odds Ratio (OR) 1.54, P = .009; OR 1.52, P = .010). Hemiparesis was not associated with higher risk of wound complications, periprosthetic joint infection, aseptic loosening, and periprosthetic fracture, but was associated with higher incidence of 90-day ED-visits (OR 1.16, P = .031) and 90-day readmission (OR 1.32, P < .001). CONCLUSION: While patients who have hemiparesis do not have increased risk of implant-related complications other than dislocation, they are at increased risk of developing medical complications following hemiarthroplasty for FNF.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Hemiartroplastia , Luxações Articulares , Humanos , Idoso , Hemiartroplastia/efeitos adversos , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Fraturas do Colo Femoral/complicações , Fraturas do Colo Femoral/cirurgia , Luxações Articulares/cirurgia , Paresia/etiologia , Paresia/complicações , Artroplastia de Quadril/efeitos adversos
7.
Eur J Orthop Surg Traumatol ; 33(5): 2069-2074, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36197500

RESUMO

PURPOSE: To assess the reliability of a standardized measurement of screw breach on postoperative computed tomography (CT) scans following percutaneous fixation of the posterior pelvic ring. METHODS: Three orthopedic trauma surgeons independently utilized a standardized method of measuring posterior pelvic ring screw breaches on post-operative CT scan images. Breaches were measured as a continuous variable on sagittal images reformatted to be perpendicular to the screw on axial images. The inter-rater and intra-rater reliability of screw breach distance measurements was assessed. RESULTS: Measurements were performed on 42 screws in 20 patients. Screw types included S1-iliosacral (IS) (n = 16), S1-transsacral (TS) (n = 8), S2-IS (n = 2), and S2-TS (n = 16). Patients with varying degrees of screw breaches were chosen to test measurements across breach severities, including 0 mm (n = 10), ≤ 2 mm (n = 12), > 2 to 4 mm (n = 11), and > 4 mm (n = 9). The mean difference and 95% confidence interval (CI) between screw breach measurements between the three surgeons was - 0.13 mm (CI - 0.48 to 0.20), 0.05 mm (CI - 0.6 to 0.7), and 0.18 mm (CI - 0.47 to 0.85), respectively. The inter-rater reliability of the measurements was considered excellent (intraclass correlation coefficient (ICC), 0.93). The mean intra-rater reliability for the observers was considered good (ICC 88.5, CI 82 to 95). CONCLUSIONS: This simple standardized method of measuring screw breaches had excellent inter-rater reliability and would support comparisons of screw breach severity across studies. LEVEL OF EVIDENCE: Level III.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Reprodutibilidade dos Testes , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Parafusos Ósseos/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões
8.
J Clin Orthop Trauma ; 33: 101994, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36061971

RESUMO

Background: Percutaneous screw fixation of the posterior pelvic ring is technically demanding and can result in cortical breach. The purpose of this study was to examine risk factors for screw breach and iatrogenic nerve injury. Methods: A retrospective review at a single level-one trauma center identified 245 patients treated with 249 screws for pelvic ring injuries with postoperative computed tomography (CT) scans. Cortical screw breach, iatrogenic nerve injury, and associated risk factors were evaluated. Results: There were 86 (35%) breached screws. The breach rate was similar between screw types (33% S1-iliosacral (S1-IS), 44% S1-transsacral (S1-TS), 31% S2-IS, and 30% S2-TS) and was not associated with patient characteristics, Tile C injuries, or corridor size or angle. The overall rate of screw revision for screw malpositioning was 1.2% (3/249). Iatrogenic nerve injuries occurred in 8 (3.2%) of the 249 screws. Screws that caused iatrogenic nerve injuries had greater screw breach distances (5.4 vs. 0 mm, MD 5, CI 2.3 to 8.7, p < 0.0001), were more likely to be S1-IS screws (88% vs. 47%, PD 40%, CI 7 to 58%, p = 0.006), more likely to be placed in Tile C injuries (75% vs. 44%, PD 31%, CI -3 to 55%, p = 0.04), and there was a trend for having a screw corridor size <10 mm (75% vs. 47%, PD 28, CI -6 to 52%, p = 0.06). Of the 7 iatrogenic nerve injuries adjacent to screw breaches, two nerve injuries recovered after screw removal, three recovered with screw retention, and two did not recover with screw retention. Conclusion: Screw breaches were common and iatrogenic nerve injuries were more likely with S1-IS screws. Surgeons should maintain a high degree of caution when placing these screws and consider removal of any breached screw associated with nerve injury.

9.
Indian J Orthop ; 56(6): 1018-1022, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35669025

RESUMO

Purpose: To evaluate the value of three-dimensional (3D) computed tomography (CT) scans on the interobserver and intraobserver reliability of AO/Orthopaedic Trauma Association (OTA) and Young and Burgess (YB) classifications for pelvic ring injuries. Methods: Seven reviewers (four fellowship-trained orthopaedic trauma surgeons and three fellows) independently classified 36 pelvic ring injuries using radiographs and axial two-dimensional (2D) CT scan images and then repeated this process 2 months later with the addition of 3D CT images. Interobserver and intraobserver reliability was assessed. Results: The interobserver reliability of the AO/OTA classification using 2D vs. 3D CT scans was considered fair (k 0.23, CI 0.17-0.29) vs. slight (k 0.16, CI 0.09-0.22), with no observed difference [mean difference (MD) - 0.07, CI 0.16-0.01]. The interobserver reliability of the YB classification using 2D vs. 3D CT scans was considered fair for both (k 0.37, CI 0.32-0.42, vs. 0.37, CI 0.30-0.45), with no observed difference (MD - 0.0005, CI - 0.08 to 0.08). The intraobserver reliability of the AO/OTA vs. YB classifications was considered fair (k 0.35, CI 0.26-0.44) vs. moderate (k 0.49, CI 0.40-0.57), with the YB classification having higher kappa value (MD 0.13, CI 0.01-0.26, p = 0.03). Conclusion: The addition of 3D CT scan reconstructions to radiographs and 2D CT did not improve the interobserver reliability of AO/OTA and YB classifications for pelvic ring injuries.

10.
J Orthop Trauma ; 36(10): 489-493, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35575625

RESUMO

OBJECTIVES: To determine whether displacement on lateral stress radiographs (LSRs) in patients with minimally displaced lateral compression type 1 pelvic ring injuries is associated with any demographic and/or injury characteristics. DESIGN: Retrospective comparative cohort. SETTING: Urban level 1 trauma center. PATIENTS/PARTICIPANTS: Ninety-three consecutive patients with minimally displaced lateral compression type 1 injuries. INTERVENTION: Displacement of pelvic ring injury on LSR (≥10 mm vs. <10 mm). MAIN OUTCOME MEASUREMENTS: Demographic and injury characteristics (mechanism of injury, Nakatani rami classification, rami comminution, Denis zone, complete/incomplete sacral fracture, sacral comminution). RESULTS: 65.6% of patients (n = 61) had ≥10 mm of displacement on LSR. On univariate analysis, displacement was associated with increased age [median difference 11: confidence interval (CI), 2-23], female sex [proportional difference (PD): 25.1%, CI, 3.9%-44.4%], Nakatani classification (type I PD: 27.9%, type II PD: -19.5%), and rami comminution (PD: 55.6%, CI, 35.4%-71.3%). On multivariate analysis, displacement was only associated with rami comminution (odds ratio: 16.48, CI, 4.67-58.17). Displacement was not associated with energy of injury mechanism, sacral fracture Denis zone, complete sacral fracture, sacral comminution, or bilateral rami fractures. CONCLUSIONS: Although rami comminution was the only variable found to be independently associated with displacement ≥10 mm on LSR, no single variable perfectly predicted displacement. Future studies are needed to determine whether displacement on stress radiographs should change the management of these injuries. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Ossos Pélvicos , Fraturas da Coluna Vertebral , Feminino , Fraturas Ósseas/complicações , Fraturas Cominutivas/complicações , Humanos , Ossos Pélvicos/lesões , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Sacro/lesões , Fraturas da Coluna Vertebral/complicações
11.
J Orthop Trauma ; 36(10): 498-502, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35452049

RESUMO

OBJECTIVE: To determine what size S1-transsacral (TS) corridor is amenable to TS screw placement, as this is commonly used to identify sacral dysmorphism, and to determine if gender, ethnicity, or screw breach is associated with narrow corridors. DESIGN: Retrospective review. SETTING: Urban level-1 trauma center. PATIENTS: Two hundred ninety patients with pelvic ring injuries and preoperative computed tomography (CT) scans. INTERVENTION: Percutaneous posterior pelvic ring fixation. MAIN OUTCOME MEASUREMENTS: The width of the S1-TS corridor was measured on the axial (inlet) and coronal (outlet) reformatted CT images. Patients with S1-TS screw fixation and postoperative CT scans were identified. Corridor size, gender, ethnicity, and screw breach were documented. RESULTS: S1-TS screws were placed in 55 of the 290 patients. No S1-TS screws were placed in corridors less than 8 mm. Corridors of <8 mm were present in 114 (39%) of the 290 patients and were not associated with gender or ethnicity. S1-TS screws placed in small (<10 mm) versus large (≥10 mm) corridors did not have a detectable difference in screw breaches (5 of 8, 62% versus 19 of 47 40%; difference, 22%, 95% confidence interval -14% to 52%) or median (interquartile range) screw breach distance [3 mm (2.5-4.8) versus 3 mm (1.2-4.8); difference, 0.9 mm; confidence interval -1.6 to 2.2]. CONCLUSION: These data are useful for the standardization of sacral dysmorphism reporting based on corridor size. Screw breaches were common irrespective of TS corridor size, emphasizing the small degree of error allowed by this procedure. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Ossos Pélvicos , Sacro , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Humanos , Ílio/cirurgia , Ossos Pélvicos/lesões , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Tomografia Computadorizada por Raios X
12.
J Orthop Trauma ; 36(10): 494-497, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35412510

RESUMO

OBJECTIVES: To evaluate the interobserver reliability of measured displacement and occult instability of minimally displaced lateral compression type 1 (LC1) fractures on lateral stress radiographs (LSRs) and to compare differences in displacement between LSR with the injured side down (ID) and up (IU). DESIGN: Retrospective review. SETTING: Urban Level 1 trauma center. PATIENTS/PARTICIPANTS: Twenty-three adult patients with minimally displaced (<1 cm) LC1 injuries. INTERVENTION: None. MAIN OUTCOME MEASUREMENTS: Three orthopaedic surgeons measured the distance between the radiographic teardrops on LSR and supine anteroposterior pelvic radiographs to calculate dynamic fracture displacement. The interobserver reliability of the measured displacement, a continuous variable, was assessed by calculating the intraclass correlation coefficient. The interobserver reliability of occult instability (≥10 mm of displacement on LSR), a categorical variable, was assessed by calculating the kappa value. Matched-pairs analysis was performed to calculate the mean difference of measurements between observers and between ID and IU LSR. RESULTS: The interobserver reliability of the measured displacement was excellent (intraclass correlation coefficient 0.93). The mean difference in measurements between observers ranged from -1.8 to 0.96 mm. The mean difference in the measured displacement between ID and IU LSRs for each observer ranged from -0.6 to 0.3 mm. There was 83% (19/23 cases) agreement on the presence of occult instability (≥10 mm of displacement on LSR) on both ID and IU LSRs. The interobserver reliability of occult instability was moderate (kappa 0.76). CONCLUSIONS: Measured fracture displacement and occult instability of minimally displaced LC1 injuries were reliably measured and identified on LSR, regardless of the laterality.


Assuntos
Fraturas por Compressão , Adulto , Fraturas por Compressão/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Centros de Traumatologia
13.
Int Orthop ; 46(5): 1165-1173, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35246719

RESUMO

PURPOSE: To determine the effect of native tibia valga on intramedullary nail (IMN) fixation of tibial shaft fractures. METHODS: Retrospective comparative cohort analysis of 110 consecutive patients with tibial shaft fractures undergoing IMN fixation at an urban level one trauma centre was performed. Medical records and radiographs were reviewed for demographics, tibia centre of rotation of angulation (CORA), nail starting point, incidence of varus malreduction, and nail/canal proportional fit. RESULTS: Tibia valga (CORA of ≥ 3 degrees) was present in 37 (33.6%) patients. The anatomic nail starting point distance (in relation to the lateral tibial spine) was significantly greater in the tibia valga group (12.0 mm vs. 5.0 mm, mean difference: 7.1 mm, 95% CI: 5.8 to 8.3 mm, p < 0.0001). Varus malreduction was more common in the tibia valga group (10.8% vs. 1.4%, proportional difference: 9.4%, 95% CI: - 1.0 to 21.3%, p = 0.04). Varus malreduction in the tibia valga group was associated with a decreased nail width/inner canal width proportion on multivariate analysis (OR = 0.683, 95% CI: 0.468 to 0.995, p = 0.0004). CONCLUSION: Native tibia valga is common, and the use of a standard coronal IMN starting point with poor nail fit can lead to iatrogenic varus malreduction. In patients with tibia valga, maximizing nail fit or utilization of a medial starting point should be considered.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Pinos Ortopédicos/efeitos adversos , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia
14.
J Orthop Trauma ; 36(9): 369-373, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34962236

RESUMO

SUMMARY: The use of antibiotic-impregnated cement as a local antibiotic delivery system is well-established as an adjunctive treatment for chronic osteomyelitis. Because the elution of antibiotics is a surface area phenomenon, the geometry of the cement is an important consideration. The antibiotic cement bead rouleaux technique is a simple and efficient method of bead fabrication that requires only 10 minutes of preparation time and readily available operating room supplies. The discoid structure of the beads provides 3 times the surface-area-to-volume ratio of a spherical bead, which facilitates antibiotic elution. Given the speed and ease of fabrication, along with optimized geometry, the antibiotic cement bead rouleaux is a useful addition to the surgeon's repertoire.


Assuntos
Antibacterianos , Osteomielite , Antibacterianos/uso terapêutico , Cimentos Ósseos , Humanos , Osteomielite/tratamento farmacológico
15.
J Orthop Trauma ; 36(4): e152-e157, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34417765

RESUMO

SUMMARY: Complex traumatic and/or infected wounds and their sequelae are a significant burden for high-volume trauma centers. Local or free flap coverage options are well described; however, they may be high risk in poor hosts with multiple comorbidities and active infections. In addition, flap coverage can result in delays in wound coverage depending on specialist availability. Porcine urinary bladder matrix grafting has been shown to be a simple definitive wound coverage option that can be performed without delay in multiple patient populations for wounds that would otherwise require flap coverage. The purpose of this article was to describe a technique for urinary bladder matrix grafting and report on a series of orthopaedic trauma patients treated with this technique.


Assuntos
Retalhos de Tecido Biológico , Ortopedia , Animais , Humanos , Suínos , Bexiga Urinária/cirurgia
16.
Eur J Orthop Surg Traumatol ; 32(2): 347-351, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33890171

RESUMO

PURPOSE: To evaluate the variability in ankle syndesmotic morphology on contralateral ankle fluoroscopic images and the reductions obtained utilizing these images. METHODS: A retrospective cohort study was performed at a level one trauma center including 46 adult patients undergoing operative fixation of malleolar ankle fractures that also had anteroposterior (AP) and lateral fluoroscopic images of the uninjured contralateral ankle intraoperatively. Contralateral and post-fixation fluoroscopic images were used to measure the tibiofibular clear space (TFCS) as a proportion of the superior clear space (SCS) on mortise images and the posterior tibiofibular distance (PTFD) as a proportion of the lateral superior clear space (LSCS) on lateral images. Differences between contralateral and post-fixation ankle measurements were compared between those patients with syndesmotic injuries and those without (control group). RESULTS: The mean TFCS/SCS and PTFD/LSCS ratios measured on contralateral ankle images were 1.2 (95% confidence interval (CI) 1.1 to 1.3; range 0.7 to 1.8) and 1.8 (95% CI 1.5 to 2; range 0.5 to 3.4). The mean difference between the contralateral and post-fixation TFCS/SCS and PTFD/LSCS in patients with and without syndesmotic fixation was 0.07 vs. 0.13 (F-ratio 0.3, p = 0.5) and -0.2 vs 0.5 (F ratio 5.2, p= 0.02). CONCLUSIONS: Contralateral syndesmotic measurements varied widely and the utilization of these images allowed for syndesmotic reductions with similar measurements. Intraoperative contralateral ankle images should be considered to assess syndesmotic reduction.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Fraturas Ósseas , Adulto , Tornozelo , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Fixação Interna de Fraturas , Humanos , Estudos Retrospectivos , Resultado do Tratamento
17.
J Orthop Trauma ; 36(6): 287-291, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34690326

RESUMO

OBJECTIVES: To determine the association of pelvic fracture displacement on lateral stress radiographs (LSRs) with the hospital course of patients with minimally displaced lateral compression type 1 (LC1) pelvic injuries. DESIGN: Retrospective review. SETTING: Level 1 trauma center. PATIENTS/PARTICIPANTS: Twenty-eight adult patients with minimally displaced (<1 cm) LC1 injuries. INTERVENTION: Nonoperative management. MAIN OUTCOME MEASUREMENTS: Delayed operative fixation, days to clear physical therapy, mobilization, hospital length of stay, and total hospital opioid morphine equivalent dose. RESULTS: LSR displacement was correlated with delayed operative fixation [r = 0.23, 95% confidence interval (CI) 0.05-1.11; P = 0.01], days to clear PT (r = 0.13, CI 0.01-0.28; P = 0.02), length of stay (r = 0.13, CI 0.006-0.26; P = 0.02), and opioid morphine equivalent dose (r = 19.4, CI 1.5-38.1; P = 0.03). A receiver operating characteristic curve for delayed operative fixation over LSR displacement had an area under the curve of 0.87. The LSR displacement threshold that maximized sensitivity and specificity for detecting patients who required delayed fixation was 10 mm (100% sensitivity and 78% specificity). Ten of the 15 patients with ≥10 mm of displacement on LSRs underwent delayed operative fixation for pain with mobilization at a median of 6 days (interquartile range 3.7-7.5). Patients with ≥10 mm of displacement on LSRs took longer to clear PT, took longer to walk 15 feet, had longer hospital stays, and used more opioids. CONCLUSIONS: LC1 fracture displacement on LSRs is associated with delayed operative fixation, difficulty mobilizing secondary to pain, longer hospital stays, and opioid use. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas Ósseas , Fraturas por Compressão , Ossos Pélvicos , Adulto , Analgésicos Opioides/uso terapêutico , Fixação Interna de Fraturas , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/terapia , Fraturas por Compressão/cirurgia , Humanos , Derivados da Morfina , Dor , Ossos Pélvicos/lesões , Estudos Retrospectivos
18.
J Orthop Trauma ; 36(7): 289-293, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34653101

RESUMO

SUMMARY: Small posterior wall rim fractures are typically stable; however, if incarcerated in the joint, they must be removed. It is possible to reduce the morbidity associated with open approaches by addressing these incarcerated fragments in a percutaneous manner. This allows the restoration of joint congruity and removal of the osteochondral fragment from the joint space. The following report details the surgical technique to accomplish this, and the results of a case series of patients who underwent this technique. The advantages include limiting the morbidity of an open approach. However, the surgeon must be prepared to convert to an open approach if percutaneous removal does not accomplish the goals of surgery-a concentric, stable hip joint.


Assuntos
Fraturas Ósseas , Luxação do Quadril , Acetábulo/cirurgia , Seguimentos , Fraturas Ósseas/cirurgia , Luxação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos
19.
J Orthop Trauma ; 36(6): 292-296, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34653102

RESUMO

OBJECTIVE: To evaluate S1 transsacral (TS) corridors on reformatted and nonreformatted computed tomography (CT) images to determine which most reliably identifies narrow corridors. DESIGN: Retrospective cohort. SETTING: Level 1 trauma center. PATIENTS: Two hundred forty-five patients with operative pelvic ring injuries. INTERVENTION: CT scan review. MAIN OUTCOME MEASUREMENTS: Preoperative CT scans were evaluated to determine the width of the S1 TS corridor on standard axial nonreformatted (ANR), axial reformatted (AR), and coronal reformatted images. Sensitivity and specificity of each format to detect a narrow corridor (<10 mm on AR or coronal reformatted) were calculated. Patients with S1 TS screws were evaluated to determine the rate of screw breach with narrow corridors. RESULTS: The axial width of the S1 TS corridor was consistently smaller on ANR versus AR images (mean difference 1.4mm, 95% confidence interval 1.1-1.5). The corridor width on ANR images was on average 86% of the AR measurement. ANR images had the highest sensitivity and specificity (100% and 98%) for detecting S1 TS corridors <10 mm. Fifty-three S1 TS screws were placed in corridors ranging 10-23 mm on AR images and 7-19 mm on ANR images. Four (57%) of the 7 screws placed in corridors less than 10 mm in width on ANR images breached the sacral cortex. CONCLUSION: Using ANR images to measure the S1 TS corridor consistently measured smaller widths than AR images and identified all narrow corridors. A high rate of screw breach was noted with screw placement in narrow corridors. LEVEL OF EVIDENCE: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Parafusos Ósseos , Sacro , Estudos de Coortes , Fixação Interna de Fraturas/métodos , Humanos , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Tomografia Computadorizada por Raios X
20.
Eur J Orthop Surg Traumatol ; 32(6): 1089-1095, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34347186

RESUMO

PURPOSE: To determine the interobserver reliability of syndesmosis assessment using intraoperative ankle mortise fluoroscopic images, with and without contralateral images. METHODS: A survey of 19 operative ankle fracture cases was administered to 17 orthopedic surgeons. Respondents were presented with fluoroscopic mortise and stress images of the ankle after fracture fixation and asked if they would fix the syndesmosis. Final fluoroscopic mortise images were then shown, and respondents were asked to assess the reduction of the syndesmosis. Six weeks later, the survey was administered again with the addition of contralateral fluoroscopic ankle mortise images. Responses were compared to a standard response agreed upon by fellowship-trained orthopedic trauma surgeons. RESULTS: Interobserver reliability for syndesmosis fixation and reduction, with and without contralateral images, was considered weak (kappa 0.48 and 0.43; mean difference 0.05, 95% confidence interval (CI) 0.01 to 0.1) and minimal (kappa 0.25 and 0.22; mean difference 0.02, CI - 0.02 to 0.08). With the addition of contralateral mortise images, the number of surgeons who changed their response for syndesmosis fixation and reduction quality ranged from 0% to 41% and 0% to 88%; with the number of responses matching the standard increasing for both fixation (proportional difference (PD) 7%, CI 1% to 14%) and reduction (PD 14%, CI 7% to 21%); CONCLUSIONS: Interobserver reliability of syndesmosis fixation and reduction remained weak to minimal between surgeons, with and without contralateral images. Future studies are necessary to understand the variability in surgeon responses in order to improve the intraoperative assessment and fixation of syndesmotic injuries.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Tornozelo , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Fixação de Fratura , Fixação Interna de Fraturas/métodos , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA